• Title/Summary/Keyword: 치료공간

Search Result 538, Processing Time 0.024 seconds

Fine Structural Changes of the Renal Corpuscle of the Mice following the Administration of 5-Fluorouracil or Mitomycin C (5-Fluorouracil 및 Mitomycin C 투여후 생쥐 콩팥소체의 미세구조 변화)

  • Ko, Jeong-Sik;Oh, Won-Young;Kim, Jin-Gook;Park, Kyung-Ho;Ahn, E-Tay
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.25-41
    • /
    • 1999
  • The experiment was performed to study the morphological responses of the renal glomeruli of the mice after administration of 5-fluorouracil or mitomycin C. 5-fluorouracil (60 mg/kg) or mitomycin-C $(400{\mu}g/kg)$ were injected subcutaneously to the animals every other day, and animals were sacrificed at 4 days or 7 days following the first injections. Pieces of tissues were observed with a JEM 100CX-II electron microscope. The observed results were as follows: 1. In the fourth day following the first injection of 5-fluorouracil or mitomycin C, components of the renal glomeruli of the mice are looked compact since they were filled with the widened the mesangium, and showed narrowing lumen of glomerular capillaries and of urinary spaces. The changes were more significant in the mitomycin C treated mice. 2. In the 5-fluorouracil treated mice, morphological changes of glomeruli were generally recovered in the seventh day, whereas the glomeruli of the mitomycin C treated mice have not shown general recovery. 3. In the fourth and seventh days following the first injection of mitomycin C, in the renal glomeruli of the mice, swollen endothelial cells, and protruded mesangeal cells into the capillary lumen are frequently observed. 4. In the fourth day following the first injection of mitomycin C, in the glomerular basal lamina of the mice, the electron densities of the lamina rara interna and the lamina rara externa were similar to the density of the lamina densa and the expanded lamina rara interna were often seen. From the above results, it is suggested that the cytotoxic effects of the mitomycin C on renal glomeruli are more severe as compared with those of 5-fluorouracil.

  • PDF

Comparison of Rice Growth under Subtropical and Temperate Environments (아열대와 온대 기후 하에서 벼 생육 비교)

  • Park H.K.;Xu Migging;Lee K.B.;Choil W.Y.;Choil M.G.;Kim S.S.;Kim C.K.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.2
    • /
    • pp.45-53
    • /
    • 2006
  • The objectives of this study are to determine the primary yield components responsible for yield differences in a subtropical environment of the Hunan province China and in a temperature environment of Honam province Korea. Field experiments were conducted in a subtropical environment in Hunan province China during 2002 and in a temperate environment in Honam province Korea during 2003. Seven rice cultivars were grown under optimum crop management in each experiment field. Yield, yield components and plant dry matter were determined at maturation. The highest yield (567 kg/10a) was produced at Honam province by Jinyou 207, a Chinese cultivar, The maximum yield at Hunan province was 453 kg/10a by Sanyou 63. On the average across cultivars, Honam produced 23% greater yields than Hunan. Sink size (spikelets per $m^2$) was responsible far these yield differences. Panicle number per $m^2$ was much greater at Honam.

4D Printing Materials for Soft Robots (소프트 로봇용 4D 프린팅 소재)

  • Sunhee Lee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.6
    • /
    • pp.667-685
    • /
    • 2022
  • This paper aims to investigate 4D printing materials for soft robots. 4D printing is a targeted evolution of the 3D printed structure in shape, property, and functionality. It is capable of self-assembly, multi-functionality, and self-repair. In addition, it is time-dependent, printer-independent, and predictable. The shape-shifting behaviors considered in 4D printing include folding, bending, twisting, linear or nonlinear expansion/contraction, surface curling, and generating surface topographical features. The shapes can shift from 1D to 1D, 1D to 2D, 2D to 2D, 1D to 3D, 2D to 3D, and 3D to 3D. In the 4D printing auxetic structure, the kinetiX is a cellular-based material design composed of rigid plates and elastic hinges. In pneumatic auxetics based on the kirigami structure, an inverse optimization method for designing and fabricating morphs three-dimensional shapes out of patterns laid out flat. When 4D printing material is molded into a deformable 3D structure, it can be applied to the exoskeleton material of soft robots such as upper and lower limbs, fingers, hands, toes, and feet. Research on 4D printing materials for soft robots is essential in developing smart clothing for healthcare in the textile and fashion industry.

Characteristics of User's Behavior across Generations for space planing in General Hospital (종합병원 환경계획을 위한 세대별 종합병원 이용행태 특성분석)

  • Park, Hey Kyung;Oh, Ji Young
    • Korea Science and Art Forum
    • /
    • v.28
    • /
    • pp.105-116
    • /
    • 2017
  • This study is a basic research to suggest user-centered general hospital environmental design guidelines, which aims to analyze user's behavior characteristics across generation in general hospital. For this purpose, this study constructed an analysis tool through the literature review with regard to generation and behavior characteristics in general hospital. Besides, an online survey regarding user's behavior in general hospital was conducted targeting from 20s to 60s, 300 persons for each group, total 1,500 persons for about 3 weeks since September 1, 2016. The results of this study are as follows: (1) Based on the generation, there were significant differences in relevant categories of their visiting frequency, visiting purpose, visiting hour, transportation, companion, behavior during the wait and selection of a general hospital. (2) In all generation, they responded that they have visited once or twice per year. People in 20s and 30s responded that their visit for the hospital is to receive specific treatment, while other people in 40s, 50s and 60s visit the hospital majorly for routine check-ups. Therefore, it is imperative for a health check-up center to design an environmental plan that reflects the characteristics of elders in 40s, 50s and 60s. (3) People in 40s, 50s and 60s usually visit a general hospital in the mornings of weekdays, while generations in 20s and 30s responded that they mostly visit the hospital in the mornings of weekend. (4) When they visit a general hospital, people in their 20s are usually using public transportations, while people in their 30s to 60s are using their own vehicle. (5) People in their 20s majorly visited 'lobby'. In older generations, they tend to visit 'outpatient clinic'. Therefore, it is necessary to build an outpatient clinic environment that considers the elderly. (6) Patients majorly responded that they are using their cell phone, while waiting for their clinic call. In elder generations, they responded that they are more likely watching TVs, reading books/magazines or doing nothing. Therefore, it is essential to provide cell-phone related services and environmental supports. Visually attractive media can be utilized for this purpose.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

Incidence of Hypertension in a Cohort of an Adult Population (성인코호트에서 고혈압 발생률)

  • Kam, Sin;Oh, Hee-Sook;Lee, Sang-Won;Woo, Kook-Hyeun;Ahn, Moon-Young;Chun, Byung-Yeol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.2
    • /
    • pp.141-146
    • /
    • 2002
  • Objectives : This study was peformed in order to assess the incidence of hypertension based on two-years follow-up of a rural hypertension-free cohort in Korea. Methods : The study cohen comprised 2,580 subjects aged above 20 (1,107 men and 1,473 women) of Chung-Song County in Kyungpook Province judged to be hypertensive-free at the baseline examination in 1996. For each of two examinations in the two-year follow-up, those subjects free of hypertension were followed for the development of hypertension to the next examination one year (1997) and two years later (1998). The drop-out rate was 24.7% in men and 19.6% in women. Hypertension was defined as follows 1) above mild hypertension as a SBP above 140 mmHg or a DBP above 90 mmMg,2) above moderate hypertension as a SBP above 160 mmHg or a DBP above 100 mmHg or when the participant reported having used antihypertensive medication after beginning this survey. Results : The age-standardized incidence of above mild hypertension was 6 per 100 person years (PYS) in men and that of above moderate hypertension was 1.2. In women, the age-standardized rate for above mild hypertension was 5.7 and 1.5 for above mild and moderate hypertension, respectively. However, the rates of incidence as calculated by the risk method were 4.8% and 1.0% in men and 4.6%, 1.2% in women, respectively. In both genders, incidence was significantly associated with advancing age(p<0.01), In men, the incidences of above moderate hypertension by age group were 0.5 per 100 PYS aged 20-39, 0.7 aged 40-49, 1.7 aged 50-59, 3.6 aged 60-69, and 5.8 aged above 70(p<0.01). In women, those the incidence measured 0.6 per 100 PYS aged 20-39, 1.8 aged 40-49, 1.3 aged 50-59, 3.3 aged 60-69, and 5.6 aged above 70(p<0.01). After age 60, the incidence of hypertension increased rapidly. Conclusions : The incidence data of hypertension reported in this study may serve as a reference data for evaluating the impact of future public efforts in the primary prevention of hypertension in Korea.