• Title/Summary/Keyword: 치료계획검증

Search Result 146, Processing Time 0.022 seconds

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

A Study on the Conditions of Dental Caries on the First Molar in the Elementary School Students in H City (H시 초등학교 학동의 제 1대구치 치아우식 실태조사 연구)

  • Kim, Eung-Gwon;Im, Sun-Hwan
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.89-94
    • /
    • 2002
  • The present study attempts to find the ways to efficiently manage dental caries, one of the major causes of tooth loss, and to cope with oral diseases that deteriorate oral health. For this purpose, this study seeks to obtain fundamental data needed in planning the oral health projects. The study was conducted to the first-grade elementary school students in Hwa-Seong city, Gyeonggi-do, from April 1 - 30, 2002. The result was as follows: 1) Among a total of 2,710 subjects, 598 (274 boys and 324 girls) have more than 1 permanent tooth with a caries legion whether it was treated or not. 2) The number of permanent teeth examined is 6,029, in which girls' teeth are more (3,165) than boys' (2,864). 3) Out of a total of 6,029 teeth examined, 1,106 permanent teeth (508 boys' and 598 girls') have caries legions. 4) Out of 1,106 permanent teeth with caries legions, 170 (15.4%) were treated - 67 teeth for boys (13.2%) and 103 teeth for girls (17.2%). 5) 22.1% of the children have experienced dental caries in their permanent teeth. Among them, 20.1% are boys and 24.1% are girls. 6) The rate of the permanent teeth that once had, or now have caries legions are 21.2%, among which the rate for boy's teeth is 20.1% and that for girl's teeth is 22.1%. 7) The number of the permanent teeth that had caries legions is 0.5 for all the subjects. A boy has 0.4 and a girl has 0.5 teeth with caries legions regardless of whether it was treated or not. 8) The rate of the permanent teeth with caries legions is 86.7% for overall subjects - 88.3% for boys and 85.3% for girls. 9) The rate of treated permanent teeth is 13.3% for all the subjects - 11.7% for boys and 14.7% for girls. Based on the above result, the study draws a conclusion that in order to prevent dental caries in young students and to perform an early treatment for the dental caries that already occurred an oral health office should be installed at all the elementary schools so that elementary school students don't experience a loss of time and effort for learning and suffer nutritional imbalance or disorder. Besides, the oral health education concerning the importance of dental care should be conducted to the citizens, especially to the young people, in the community as an essential project of oral health centers in the community health offices, the public medical institutions.

  • PDF

A Comparison of Peripheral Doses Scattered from a Physical Wedge and an Enhanced Dynamic Wedge (금속쐐기와 기능강화동적쐐기의 조사야 주변부 선량 비교)

  • Park, Jong-Min;Kim, Hee-Jung;Min, Je-Soon;Lee, Je-Hee;Park, Charn-Il;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.107-117
    • /
    • 2007
  • In order to evaluate the radio-protective advantage of an enhanced dynamic wedge (EDW) over a physical wedge (PW), we measured peripheral doses scattered from both types of wedges using a 2D array of ion-chambers. A 2D array of ion-chambers was used for this purpose. In order to confirm the accuracy of the device we first compared measured profiles of open fields with the profiles calculated by our commissioned treatment planning system. Then, we measured peripheral doses for the wedge angles of $15^{\circ},\;30^{\circ},\;45^{\circ},\;and\;60^{\circ}$ at source to surface distances (SSD) of 80 cm and 90 cm. The measured points were located at 0.5 cm depth from 1 cm to 5 cm outside of the field edge. In addition, the measurements were repeated by using thermoluminescence dosimeters (TLD). The peripheral doses of EDW were (1.4% to 11.9%) lower than those of PW (2.5% to 12.4%). At 15 MV energy, the average peripheral doses of both wedges were 2.9% higher than those at 6MV energy. At a small SSD (80 cm vs. 90 cm), peripheral dose differences were more recognizable. The average peripheral doses to the heel direction were 0.9% lower than those to the toe direction. The results from the TLD measurements confirmed these findings with similar tendency. Dynamic wedges can reduce unnecessary scattered doses to normal tissues outside of the field edge in many clinical situations. Such an advantage is more profound in the treatment of steeper wedge angles, and shorter SSD.

  • PDF

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

A Study of Psychometric Function Curve for Korean Standard Monosyllabic Word Lists for Preschoolers (KS-MWL-P) (한국표준 학령전기용 단음절어표 (Korean Standard Monosyllabic Word Lists for Preschoolers, KS-MWL-P)의 심리음향기능곡선 연구)

  • Shin, Hyun-Wook;Kim, Jin-Sook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.534-541
    • /
    • 2009
  • Word recognition test (WRT) for the children can be useful for diagnosing the degree of communication disability, prescribing hearing instruments, planning aural rehabilitation and speech therapy, and determination of site of lesions. The Korean standard monosyllabic word lists for preschoolers (KS-MWL-P) were developed considering the criteria given by the literatures. However, the authors of KS-MWL-P suggested more children should be included to verify homogeneity of the lists using psychometric function curve since only 8 children participated in the developing process. The purpose of this study was to explore the homogeneity of KS-MWL-P for supplementing the limitations of the lists employing psychometric analysis. To 23 preschoolers who have normal-hearing, 100 monosyllabic KS-MWL-P words were examined with the pictures. Psychometric function curve with linear slopes of 20% and 80%'s correct rates through accounting recognition scores of each monosyllabic word at variable intensities from -10 to 40 dBHL was obtained and analyzed. As a result, s-shaped psychometric function curve was presented with increasing correct rate depending on intensity and showed no statistical significant differences among each word and list. The congruous graph shapes among lists also indicated good homogeneity and the list 1,2,3,4's average slopes were 4.48, 3.86, 4.65, 4.50. It was verified that the homogeneity was suitable because the analysis of variance showed no statistical significance among lists (p>0.05). However, KS-MWL-P's order of slope according to the order of the number of items, $1{\sim}10$, $1{\sim}20$, $1{\sim}25$ showed no difference with the p-value of 0.93, 0.59, 0.91, 0.70 for the lists 1,2,3, and 4, respectively. Although KS-MWL-P was assumed that the lower-numbered items were easy for testing younger ages, this study's results could not agree with the author's conclusion. Considering this matter, rearranging of the number of items should be performed according to the analysis of slope suggested by this study for testing younger children with easier items. Other than this, in conclusion, KS-MWL-P was proved to be useful for clinical and rehabilitative evaluating and training tools for preschoolers.