• Title/Summary/Keyword: 치과 보철물 디자인

Search Result 45, Processing Time 0.023 seconds

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.

Fixed implant rehabilitation of maxillary edentulous patient using intraoral scanning digital workflow: a case report (상악 완전 무치악 환자에서 구강 스캐닝 디지털 워크플로우를 활용한 완전 고정성 임플란트 수복 증례)

  • Seung Min Park;YoungBum Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.38-46
    • /
    • 2024
  • In order to treat edentulous patients with fixed implant prosthesis, the final prosthesis form should be predetermined based on the anatomic structures of the arch, the opposing dentition, and the occlusal plane. The design and occlusion of the interim prosthesis can provide useful information when fabricating the definitive prosthesis. In this case report, scan data of the edentulous region and the interim prosthesis were superimposed through an intraoral scanning digital workflow. In this way, the interim prosthesis information was incorporated into the design of the final prosthesis. Furthermore, the interim prosthesis data acquired through intraoral scanning was utilized to plan the positions and angles of the implants based on the final prosthesis design. Surgical guides were used to accurately place the implants in the planned three-dimensional positions. In this case report, satisfactory esthetic and functional clinical outcomes were achieved through application of digital techniques.

Using 3-dimensional digital smile design in esthetic restoration of anterior teeth: A case report (3차원 Digital Smile Design을 활용한 전치부 심미수복 증례)

  • Hong, Sungman;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.451-458
    • /
    • 2021
  • Currently, digital technology is being used in various fields of dental treatment. In particular, in the case of anterior esthetic restoration, the traditional restoration method cannot contain facial information and it is difficult for the patient to predict the treatment result. However, in the case of esthetic restoration through digital design, the visualization of the prosthesis design and the ease of reflecting patient feedback, and expecting the treatment result is available. In this case, the patient confirmed the results of restoration treatment using a digital method before treatment and obtained consent for treatment in an anterior tooth trauma patient. In addition, since the conventional digital smile design method uses only the patient's facial and smile information, the design was made on a two-dimensional plane, and its application was somewhat limited. However, in this case, a three-dimensional virtual patient was created and thus the designed restoration was viewed from various angles. Through this case, it was possible to obtain a high degree of satisfaction with the ease of communication with the patient and the technician during the esthetic restoration using the digital method, the simplicity of the procedure, and the treatment result.

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

Properties of translucent zirconia and lithium disilicate glass-ceramics: a literature review (반투명 지르코니아와 리튬디실리케이트 결정화유리의 물성에 관한 문헌고찰)

  • Cha, Min-Sang;Kim, Ye-Jin;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.71-80
    • /
    • 2022
  • Although low translucency 3 mol% yttria stabilized tetragonal zirconia polycrystal has excellent mechanical properties, it has limited application as a monolithic prosthesis. To improve these optical limitations, translucent zirconia has improved esthetics due to an increase in the cubic phase; however, it is accompanied by a decrease in mechanical properties simultaneously. Lithium disilicate has improved its mechanical properties through crystal size reduction and various heat treatment methods; therefore, its clinical application range is continuously increasing. Translucent zirconia shows a wide distribution of physical properties depending on the yttria content and lithium disilicate according to the size and density of crystal grains. As a result, the indications for translucent zirconia and lithium disilicate are increasing. Therefore, in this literature review, we intend to examine the rationale behind the material selection criteria in clinical situations and considerations for designing fixed dental prostheses including pontic, in particular, by summarizing recent studies.

Full mouth rehabilitation of a worn dentition using digital guided tooth preparation: a case report (과도한 구치부 마모를 보이는 환자에서 digital guided tooth preparation을 이용한 완전 구강 회복 증례)

  • Kim, Yong-Kyu;Yeo, In-Sung Luke;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.80-90
    • /
    • 2022
  • With the development of digital dentistry, it is being applied in various ways of dental treatment. This case report presents the definitive prosthesis designed in advance with a re-established vertical dimension and the digital technology, which determined the amount of tooth preparation, in order to preserve as much tooth structure as possible in a patient with pathological wear of the posterior teeth and loss of vertical dimension. For accurate tooth preparation, the guides of the occlusal and axial surfaces were digitally and additively manufactured. Then, aesthetics and anterior guidance were established at the provisional stage. The information of the provisional restoration was delivered to the definitive stage by double scanning. The digital technology, including the virtual planning and the guided tooth removal, produced the definitive restorations satisfactory to both the patient and clinician.

Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis (나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가)

  • Chung, Chae-Heon;Son, Mee-Kyoung;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the clinical performance of screw- and cement-retained implant prosthesis (SCP) design in terms of retained preload of abutment screws and cement washout. Materials and methods: Patients with the partial posterior edentulous areas comprised the study group. Implants were placed, and SCPs were delivered after 3 to 6 months healing. Follow-up examinations were performed. The implant survival rate and the prosthetic success rate were evaluated. The retained preload ratio of abutment screws and the prosthetic decementation ratio were measured. Results: Twenty one SCPs (forty three implants)in twenty patients were followed up to 64 months. All of the implants survived during the follow-up period (mean follow-up: 34 months). The prosthetic success rate was 100 % considering no abutment, screw, porcelain or metal frame fractures, as well as no screw loosening. The retained preload ratio of SCPs at the end of follow-up period was 97.61% (${\pm}16.29$) and the decementation ratio was 9.5 %. Conclusion: Within the limitations of this clinical study, SCP design showed favorable short-term clinical performances in respect of screw loosening and cement washout.

Margin Design

  • O, Nam-Sik
    • The Journal of the Korean dental association
    • /
    • v.41 no.8 s.411
    • /
    • pp.552-557
    • /
    • 2003
  • 치아 삭제의 원리 중 변연과 관련된 조건들과 다양한 보철물 마무리에 따른 특성을 살펴보고 완전 도재관의 변연 각도에 따른 적합도와 응력분포에 대한 실험 결과를 참고해 적절한 변연 디자인 선택시에 도움이 되고자 한다. 성공적인 보철물 변연은 마무리선에 정확히 맞아야하는 fitness(cement의 노출 최소), 환자와 술자의 입장에서 청결 가능한 부위에 위치되어야 하는 location, 그리고 교합력에 충분히 저항할 수 있는 stress를 만족할 수 있어야 할 것이다.

  • PDF

Full-mouth rehabilitation of a patient with severe wear using digital facebow transfer and virtual articulator (디지털 안궁이전과 가상교합기를 이용한 광범위한 치아 마모 환자의 완전구강회복 증례)

  • Jinmook Chung;Younghoo Lee;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Hyeong-Seob Kim;Kung-Rock Kwon;Ahran Pae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.275-283
    • /
    • 2023
  • The progressive wear of teeth is a physiologic process of aging, but excessive wear can lead to occlusal disharmony, tooth sensitivity and pulp exposure, decreased masticatory efficiency, and aesthetic problems. It should be treated by evaluating the cause of tooth wear and establishing a stable centric relation with appropriate vertical dimension of occlusion and occlusal plane. The present case report successfully rehabilitated a full-mouth case of a severely worn dentition with the use of digital facebow transfer and virtual articulator.

Single-unit fixed restoration using the automated crown shaping artificial intelligence program (자동 치관 형성 인공지능 프로그램을 이용한 단일 고정성 보철물 수복 증례)

  • Eun-Bi Park;Young-Eun Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.169-178
    • /
    • 2024
  • Recently, several attempts have been made to integrate AI into the field of dentistry. To overcome the limitations of traditional fixed prosthetic fabrication methods such as CAD-CAM (computer-aided design-computer-aided manufacturing), AI programs are being developed for automated crown fabrication, and various studies are underway to applicate in clinical situation. In these case studies, single-unit fixed prostheses were fabricated using an AI program (Dentbird Crown, Imagoworks Inc, Seoul, Korea) in both the anterior and posterior regions and the fabrication time and accuracy were compared with previously used CAD-CAM method. The first case is a 44-year-old woman who presented for re-fabrication of a zirconia prosthesis due to a prosthesis fracture on the lingual side of the upper right lateral incisor. The second case is a 53-year-old male patient who presented for a crown restoration on an upper left first molar following root canal treatment, where he received a final zirconia restoration. In both cases, the first prosthesis was designed manually using a CAD program, the second prosthesis was designed using AI alone, and the third prosthesis was designed using AI and then modified by CAD program, and the three designs were superimposed to compare suitability. When evaluated after temporary placement, the final prosthesis demonstrates adequate stability, retention and support, resulting in functional and esthetic satisfaction.