• Title/Summary/Keyword: 치경부 폭경

Search Result 5, Processing Time 0.024 seconds

A Morphometric Study of the Stainless Steel Permanent Molar Crown with Three-Dimensional Scanner (3차원 스캐너를 이용한 대구치용 기성금속관의 형태에 관한 계측학적 연구)

  • Shin, Jonghyun;Lee, Hyeongjik;Jeong, Taesung;Kim, Shin;Kim, Jiyeon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.287-300
    • /
    • 2018
  • The aim of this study was to compare the morphological characteristics of two types of stainless steel permanent molar crowns using three-dimensional scanners and the morphological changes of these crowns after crimping. Two types of stainless steel permanent molar crowns, PO-96 and PERMACROWN were scanned using three-dimensional scanner. Crown size, crown index (ratio of buccolingual diameter to mesiodistal diameter at height of contour), cervical convergency of crown were measured. Stainless steel crowns were crimped and re-scanned with three-dimensional scanner. Morphological changes of stainless steel permanent molar crowns were analyzed. As for the crown index, maxillary PERMACROWN was larger buccolingually and smaller mesiodistally than maxillary PO-96 and mandibular PERMACROWN was smaller buccolingually and larger mesiodistally than mandibular PO-96. Maxillary PO-96 was more convergent to cervical mesiodistally than maxillary PERMACROWN and mandibular PO-96 was more convergent to the cervical mesiodistally, buccolingually than mandibular PERMACROWN. Both types of stainless steel permanent molar crowns showed reduction of cervical circumference after crimping. Two products were morphologically different in crown size, shape and cervical convergence. Although both types of stainless steel permanent molar crowns are pre-contoured type, additional crimping is needed to achieve better marginal adaptation.

STUDY ON ADAPTABILITY OF RUBBER DAM CLAMPS ON PRIMARY SECOND MOLARS IN KOREAN CHILDREN (한국인 소아에서 제2유구치에 대한 러버댐 클램프의 적합도에 관한 연구)

  • Park, Mirae;Mah, Yon-Joo;Ahn, Byung Duk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.2
    • /
    • pp.98-105
    • /
    • 2013
  • The purpose of this study was to investigate the mesiodistal widths at the cervical level of primary second molars in Korean children, and to compare them with commercial rubber dam clamps commonly used in pediatric dentistry. Dental casts of 115 primary and mixed dentition children were studied. Cervical mesiodistal width (C-MD) was measured at the clinical cervical level of each primary second molar from buccal and lingual sides using a digital caliper (Absolute, Mitutoyo, Kawasaki, Japan). The data were compared with mesiodistal widths of rubber dam clamps #203/204, #10/11, and #205 (Dentech, Japan). C-MDs of primary mandibular second molars were larger than those of primary maxillary second molars, and C-MDs at buccal sides were larger than those of lingual sides. All C-MDs showed statistically significant discrepancies to corresponding widths on clamps (p < 0.05). However the amount of discrepancy was mild in maxillary teeth, while up to 1 mm of discrepancy was shown in mandibular teeth. In conclusion, C-MDs measured in this study imply a relatively fair fit of #10/#11 or #203/#204 clamps on primary maxillary second molars, while suggesting our need for a better clamp with proper size for primary mandibular second molars.

Relationship between mesiodistal width and enamel thickness in mandibular incisors (하악 절치 근원심폭경과 법랑질 두께의 관계)

  • Han, Uk;Gang, Sung-Nam;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.41 no.3
    • /
    • pp.184-190
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the relationship between the enamel thickness of proximal surfaces and the morphologic features of mandibular incisors. Methods: Mesiodistal/faciolingual (MD/FL) index, MD width, and height of contour width/cervical width ratio were measured in 40 incisors extracted from Koreans. For determining the height of contour width/cervical width ratio, the cervical width was measured as the distance between proximal cementoenamel junctions. Then, the labial surface was ground to the height of the contour level to measure enamel thickness. Pearson correlation analysis was used to investigate the correlation between enamel thickness and morphologic features. Results: Enamel thickness was $0.75{\pm}0.07mm$ per side, and MD width was $5.56{\pm}0.40mm$. Enamel thickness and MD width were significantly correlated. However, a significant relationship was not observed between enamel thickness and MD/FL index or the height of contour width/cervical width ratio. Conclusions: The results suggest that enamel thickness is affected only by MD width. Therefore, if the MD width is the same for mandibular incisors with a large MD/FL index or triangular shape and mandibular incisors with normal shape, then the limit of enamel reduction for reproximation will be the same.

EARLY HISTO(PATHO)LOGIC CHANGES AND RECOVERY OF TOOTH AND PERIODONTAL TISSUE IN INTRUSION OF PREMOLAR ON YOUNG ADULT DOGS (유성견의 소구치 압하시 초기 치아 및 치주 조직의 조직학적 변화와 재생에 관한 연구)

  • Ahn, Byeong-Kyo;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.297-310
    • /
    • 1998
  • The purpose of this study was to investigate the initial tissue change, to repair on the teeth & surrounding tissue under the intrusive orthodontic forces by use of elastic chain, through the microscopic findings. For this study, three young adult mongrel dogs were used, and were divied into three group : the control group was deliveried only casting crown and the experimental group 1 was equipped with energy chain during 1 week and experimental 2 group was deliveried using energy chain during 1 week and 3 weeks observation. All experimental groups and control groups were sacrificed to make the samples for microscopic findings on premolar teeth. All samples were examed and compared the histologic changes through the microscopic with H-E stain. The obtained results were as follows. 1. In hematoxylin-eosin stain of the control group, the periodontal ligament was constant width from apical third to cervical third of the root, and the periodontal fiber arrangement was horizontal or oblique in cervical third, oblique in middle and apical third of the root. 2. In Masson Trichrome stain of the control group, osteoblast and osteoclast appeared in cervical third of root, and bone resorption and new bone formation was observed in middle and apical third of the root. 3. In experimental 1, osteoclasts were increased highly, and hyperemia of blood vessels and new bone formation and bone resorption by reversal line in apical third of the root were seen. PDL width was increased apprarently from crest to apex of the root and more in apical third. 4. In experimental 2, osteoclasts and hyperemia of blood vessels were more increased than control material in apical third of the root. PDL width was increased more than control group in root apex, and was seen less than experimental 1. PDL arrangement was similar to experimental 1 and was mixed only in root apex. Therefore, in premolar intrusion of the young adult dog, there were increased osteoclast, hyperemia and dilation of blood vessel, resorption of alveolar bone and cementum and different arrangement of PDL in initial tissue change. There was not observed complete repair after remove intrusive force.

  • PDF

Marginal fit of In-Ceram crown according to shoulder width (In-Ceram 전부도재관의 shoulder 폭경에 따른 변연적합도)

  • Chun, Seung-Geun;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.105-112
    • /
    • 2000
  • In-Ceram system is one of contemporary esthetic all ceramic restorations and has relatively high flexural strength. The purpose of this study was to evaluate the marginal fit of In-Ceram crown according to shoulder width and measuring position. In this study, twenty seven In-Ceram crowns devided into three groups, each prepared with shoulder width of 0.6mm, 0.9mm and 1.2mm. All specimens were cemented with glass ionomer cement. After cementation, specimens were measured marginal gap between the margin of the In-Ceram crown and the finishing line of resin master die by using a refrective microscope. Marginal gaps were recorded at the labial, lingual, mesial and distal measuring points on the resin master die. The results of this study were as follows: 1. Mean marginal fits of each group were $81.28{\mu}m$ in 0.6mm shoulder width, $70.78{\mu}m$ in 0.9mm shoulder width and $67.75{\mu}m$ in 1.2mm shoulder width. 2. There was significant difference between group 0.6mm and 0.9mm, 1.2mm.(p<0.05). 3. In comparison of marginal fit according to the measuring points, there was no significant difference.

  • PDF