DOI QR코드

DOI QR Code

A Morphometric Study of the Stainless Steel Permanent Molar Crown with Three-Dimensional Scanner

3차원 스캐너를 이용한 대구치용 기성금속관의 형태에 관한 계측학적 연구

  • Shin, Jonghyun (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Lee, Hyeongjik (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Jeong, Taesung (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Kim, Shin (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Kim, Jiyeon (Department of Pediatric Dentistry, College of Dentistry, Pusan National University)
  • 신종현 (부산대학교 치과대학 소아치과학교실) ;
  • 이형직 (부산대학교 치과대학 소아치과학교실) ;
  • 정태성 (부산대학교 치과대학 소아치과학교실) ;
  • 김신 (부산대학교 치과대학 소아치과학교실) ;
  • 김지연 (부산대학교 치과대학 소아치과학교실)
  • Received : 2018.11.08
  • Accepted : 2018.11.15
  • Published : 2018.12.30

Abstract

The aim of this study was to compare the morphological characteristics of two types of stainless steel permanent molar crowns using three-dimensional scanners and the morphological changes of these crowns after crimping. Two types of stainless steel permanent molar crowns, PO-96 and PERMACROWN were scanned using three-dimensional scanner. Crown size, crown index (ratio of buccolingual diameter to mesiodistal diameter at height of contour), cervical convergency of crown were measured. Stainless steel crowns were crimped and re-scanned with three-dimensional scanner. Morphological changes of stainless steel permanent molar crowns were analyzed. As for the crown index, maxillary PERMACROWN was larger buccolingually and smaller mesiodistally than maxillary PO-96 and mandibular PERMACROWN was smaller buccolingually and larger mesiodistally than mandibular PO-96. Maxillary PO-96 was more convergent to cervical mesiodistally than maxillary PERMACROWN and mandibular PO-96 was more convergent to the cervical mesiodistally, buccolingually than mandibular PERMACROWN. Both types of stainless steel permanent molar crowns showed reduction of cervical circumference after crimping. Two products were morphologically different in crown size, shape and cervical convergence. Although both types of stainless steel permanent molar crowns are pre-contoured type, additional crimping is needed to achieve better marginal adaptation.

본 연구의 목적은 3차원 스캐너를 이용하여 현재 시판중인 두 종류의 대구치용 기성금속관의 형태적 특성을 비교하는 것이며, 또한 crimping 후의 치경부측 형태 변화를 분석 후 비교하는 것이다. 3차원 스캐너를 이용하여 상, 하악 대구치용 기성금속관인 PO-96과 PERMACROWN의 크기, crown index, 치경부 수렴도를 계측하였다. 이후 기성금속관들은 crimping을 통하여 치경부 형태를 조정하였고 3차원 스캐너를 통해 다시 스캔을 시행한 후 형태적 변화를 분석하였다. 상악 기성금속관의 폭경은 PERMACROWN이 PO-96에 비해 협설로 더 컸고 근원심으로는 더 작았으며, 치경부의 근원심 형태는 더 볼록하였다. 하악에서는 PERMACROWN이 PO-96에 비해 폭경은 협설로 작고 근원심으로 컸으며, 치경부의 근원심, 협설측 모두 더 볼록한 형태를 보였다. 그리고 두 기성금속관 모두 crimping 이후 치경부 변연 둘레는 감소하였다. 두 기성금속관은 크기, 형태, 치경부 수렴도에서 형태학적 차이를 보였다. 두 대구치용 기성금속관 모두 치경부 형태가 부여되어있지만 더 나은 변연적합을 위해서는 추가적인 crimping이 필요하다.

Keywords

Acknowledgement

Supported by : Pusan National University

References

  1. Humphrey WP. Uses of chrome steel in children's dentistry. Dent Surv. 1950;26(945):9.
  2. Randall RC, VRIJHOEF MM, WILSON NH. Efficacy of preformed metal crowns vs. amalgam restorations: in primary molars: a systematic review. J Am Dent Assoc. 2000;131(3):337-43. https://doi.org/10.14219/jada.archive.2000.0177
  3. Margetts B, Brown T. Crown diameters of the deciduous teeth in Australian Aboriginals. Am J Phys Anthropol. 1978;48(4):493-502. https://doi.org/10.1002/ajpa.1330480408
  4. Moss J, Ismail S, Hennessy R. Three-dimensional assessment of treatment outcomes on the face. Orthod Craniofac Res. 2003;6(s1):126-31. https://doi.org/10.1034/j.1600-0544.2003.245.x
  5. Moon J. Kim J, Bae J, Oh S. Three-dimensional assessment of treatment outcomes on the face. Korean J Dent Mater. 2017;44(1):53-60. https://doi.org/10.14815/kjdm.2017.44.1.053
  6. Seale NS. The use of stainless steel crowns. Pediatr Dent. 2002;24(5):501-5.
  7. Memarpour M, Mesbahi M, Rezvani G, Rahimi M. Microleakage of adhesive and nonadhesive luting cements for stainless steel crowns. Pediatr Dent. 2011;33(7):501-4.
  8. Myers DR. A clinical study of the response of the gingival tissue surrounding stainless steel crowns. ASDC J Dent Child. 1975;42(4):281-4.
  9. Shiflett K, White SN. Microleakage of cements for stainless steel crowns. Pediatr Dent. 1997;19:262-6.
  10. Yilmaz Y, Belduz Kara N, Yilmaz A, Sahin H. Wear and repair of stainless steel crowns. Eur J Paediatr Dent. 2011;12(1):25.
  11. Dietrich G, Sperling S, Hetzer G. Molar incisor hypomineralisation in a group of children and adolescents living in Dresden (Germany). Eur J Paediatr Dent. 2003;4:133-7.
  12. Crombie F, Manton D, Weerheijm K, Kilpatrick N. Molar incisor hypomineralization: a survey of members of the Australian and New Zealand Society of Paediatric Dentistry. Aust Dent J. 2008;53(2):160-6. https://doi.org/10.1111/j.1834-7819.2008.00026.x
  13. Mathu-Muju K, Wright JT. Diagnosis and treatment of molar incisor hypomineralization. Compend Contin Educ Dent. 2006;27(11):604-10; quiz 11.
  14. Piwowarczyk A, Lauer H-C, Sorensen JA. Microleakage of various cementing agents for full cast crowns. Dent Mater. 2005;21(5):445-53. https://doi.org/10.1016/j.dental.2004.07.009
  15. Jung B, Shin J, Jeong T, Kim J, Kim S. Micro-CT Evaluation of Stainless Steel Crowns on Extracted Primary Molars. J Korean Acad Pediatr Dent. 2015;42(1):53-61.
  16. Rector J, Mitchell RJ, Spedding RH. The influence of tooth preparation and crown manipulation on the mechanical retention of stainless steel crowns. ASDC J Dent Child. 1985;52(6):422-7.
  17. Spedding RH. Two principles for improving the adaptation of stainless steel crowns to primary molars. Dent Clin North Am. 1984;28(1):157-75.
  18. Savide N, Caputo A, Luke L. The effect of tooth preparation on the retention of stainless steel crowns. ASDC J Dent Child. 1979;46(5):385-9.
  19. Moorrees CF, Thomsen SO, Jensen E, Yen PK-J. Mesiodistal crown diameters of the deciduous and permanent teeth in individuals. J Dent Res. 1957;36(1):39-47. https://doi.org/10.1177/00220345570360011501
  20. Choi J, Choi B, Kim S. Marginal fit of the prosthesis fabricated by dental oral scanner and model scanner. Korean J Dent Mater. 2017;44(1):79. https://doi.org/10.14815/kjdm.2017.44.1.079
  21. Sousa MVS, Vasconcelos EC, Janson G, Garib D, Pinzan A. Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofacial Orthop. 2012;142(2):269-73. https://doi.org/10.1016/j.ajodo.2011.12.028
  22. Jeon T, Kang M, Um I, Ryu J, Jun SH. Volumetric assessment of alveolar bone ridge after socket preservation using 3-dimensional surface model analysis. Korean J Dent Mater. 2017;44(4):377-86. https://doi.org/10.14815/kjdm.2017.44.4.377
  23. Baik B, Park J, Kim J, Lee D. A study on the size of the permanent teeth. J Korean Acad Pediatr Dent. 2003;30(3):502-9.