• Title/Summary/Keyword: 측정헤드

Search Result 365, Processing Time 0.023 seconds

The Implementation of Real-time Performance Monitor for Multi-thread Application (멀티스레드 어플리케이션을 위한 실시간 성능모니터의 구현)

  • Kim, Jin-Hyuk;Shin, Kwang-Sik;Yoon, Wan-Oh;Lee, Chang-Ho;Choi, Sang-Bang
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.3
    • /
    • pp.82-90
    • /
    • 2011
  • Multi-core system is becoming more general with development of microprocessors. Due to this change in performance improvement paradigm, switching conventional single thread applications with multi thread applications. Performance monitoring tools are used to optimize application performance because of complexity in development of multi thread applications. Conventional performance monitoring tools are focused on performance itself rather than user friendliness or real-time support. Real-time performance monitor identify the problem while multi-threaded applications should be performed as well as check real-time operating status of the application. So it can be used as an effective tool compared to non-real-time performance monitor that only with simple performance indicators to find the cause of the problem. In this paper, we propose RMPM(Real-time Multi-core Performance Monitor) which is real-time performance monitoring tool for multi-core system. Observation period is optimized by comparing relation between overhead due to performance evaluation period and accuracy. Our performance monitor shows not only amount of CPU usage of whole system, memory usage, network usage but also aspect of overhead distribution per thread of an application.

Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation (Geant4 Simulation에서 Linac 광자선을 이용한 폐 선량평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.443-450
    • /
    • 2018
  • The Geant 4 simulated the linear accelerator (VARIAN CLINAC) based on the previously implemented BEAMnrC data, using the head structure of the linear accelerator. In the 10 MV photon flux, Geant4 was compared with the measured value of the percentage of the deep dose and the lateral dose of the water phantom. In order to apply the dose calculation to the body part, the actual patient's lung area was scanned at 5 mm intervals. Geant4 dose distributions were obtained by irradiating 10 MV photons at the irradiation field ($5{\times}5cm^2$) and SAD 100 cm of the water phantom. This result is difficult to measure the dose absorbed in the actual lung of the patient so the doses by the treatment planning system were compared. The deep dose curve measured by water phantom and the deep dose curve calculated by Geant4 were well within ${\pm}3%$ of most depths except the build-up area. However, at the 5 cm and 20 cm sites, 2.95% and 2.87% were somewhat higher in the calculation of the dose using Geant4. These two points were confirmed by the geometry file of Genat4, and it was found that the dose was increased because thoracic spine and sternum were located. In cone beam CT, the dose distribution error of the lungs was similar within 3%. Therefore, if the contour map of the dose can be directly expressed in the DICOM file when calculating the dose using Geant4, the clinical application of Geant4 will be used variously.

Accuracy Improvement of Laser Navigation System using FIS and Reliability (FIS와 신뢰도를 이용한 레이저 내비게이션의 정밀도 향상)

  • Jung, Eun-Kook;Kim, Jung-Min;Jung, Kyung-Hoon;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.3
    • /
    • pp.383-388
    • /
    • 2011
  • This paper presents to study the accuracy improvement of the laser navigation using FIS(fuzzy inference system) and the reliability. As wireless guidance system, the top-mounted laser with the laser navigation can rotate $360^{\circ}$ with phototransistor or other optical sensors that read the return signal from reflectors mounted at the perimeter of the workspace. The type of major existing guidance systems is a wire guidance system. Because they have high accuracy and fast response time, they are used to most industries. However, their installation cost is very expensive and maintenance is very difficult because their sensors are placed approximately 1 inch below the ground or embedded in the floor. To solve those problems, the laser navigation was developed as a wire guidance system. It does not need to reconstruct a floor or ground. And it can reduce costs of installation and maintenance because changing the layout is easy. However, it is difficult to apply to an industrial field because it is easily affected by disturbances which cause loss and damage of data, and has slow respond time. Therefore, we study the accuracy improvement of the laser navigation. The proposed method is a correction method using reliability of the laser navigation. here, reliability is calculated by FIS which is designed with the analyzed characteristics of the laser navigation. For performance comparison, we use original position data form the laser navigation and position data corrected by original reliability from the laser navigation. In experimental result, we verified that the performance of the proposed method compared the others is improved by about 50% or more.

Correlation Analysis of Cutter Acting Force and Temperature During the Linear Cutting Test Accompanied by Infrared Thermography (선형절삭시험과 적외선 열화상 측정을 통한 픽커터 작용력과 발생 온도의 상관관계 분석)

  • Soo-Ho Chang;Tae-Ho Kang;Chulho Lee;Hoyoung Jeong;Soon-Wook Choi
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.519-533
    • /
    • 2023
  • In this study, the linear cutting tests of pick cutters were carried out on a granitic rock with the average compressive strength over 100 MPa. From the tests, the correlation between the cutter acting force and the temperature measured by infrared thermal imaging camera during rock cutting was analyzed. In every experimental condition, the maximum temperature was measured at the rock surface where the chipping occurred, and the temperature generated in the rock was closely correlated with the cutter acting force. On the other hand, the temperature of a pick cutter increased up to only 36℃ above the ambient temperature, and the correlation with the cutter force was not obvious. This can be attributed to the short cutting distance under laboratory conditions and the high thermal conductivity of the tungsten carbide inserts. However, the relatively high temperature of the tungsten carbide inserts was found to be maintained. Therefore, it is recommended that a reinforcement between the insert and the head of a pick cutter or the quality improvement of silvering brazing in the production of a cutter is necessary to maintain the high cutting performance of a pick cutter.

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Efficient Message Scheduling Protocol for Variable-sized Messages in a WDM-based Local Network with Nonzero Tuning Time (WDM 기반의 근거리 망에서 변조시간을 고려한 효율적인 가변 길이 메시지 예약 프로토콜)

    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.8A
    • /
    • pp.1238-1246
    • /
    • 2000
  • In a multi-channel network based on wavelength division multiplexing (WDM), an efficient protocol is needed for transmitter and receiver to be tuned to same wavelength during message transmission time. This paper proposes a message scheduling protocol that can efficiently support variable-sized messages, where tunable transceiver has nonzero tuning time. In this protocol, once a node reserves one data channel, it can persistently use the reserved channel till message transmission is finished. Therefore, overhead due to tuning time of the tunable transceiver can be reduced. Moreover, the protocol does not require any global information. Therefore, it can operate independently of the change of the number of nodes, and any new node can join the network at anytime without requiring network initialization. With this protocol, one can avoid data channel and destination conflicts. The protocol is analyzed with a finite population model and the throughput-delay characteristics are investigated as performance measures.

  • PDF

A Study on The IPTV Quality Using FR or The NR Measurement (FR, NR 측정 방식을 이용한 IPTV 품질에 관한 연구)

  • Lee, Jae-Jeong;Nam, Ki-Dong;Kim, Chang-Bong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.8
    • /
    • pp.59-66
    • /
    • 2009
  • Recently, as the expectation about the IPTV (Internet Protocol TV) service quality is rapidly increased by the development of the national high-speed internet and TPS (the Triple Play Service : data + image + audio) service Therefore, the enactment of the national quality standards about the IPTV service quality guaranteeing the real time video quality of a subscriber and the international standards are hastily needed. This paper built a test bed with the network domain and the subscriber set-top box domain including the headend area and commercial network characteristic in order to test in the environment which is similar to the characteristic of the service business network. And by using the constructed environment, the characteristics required for SLA(service Level Agreement) of the IPTV service are presented as the quality test according to the service environment change.

Analysis of Job Scheduling and the Efficiency for Multi-core Mobile GPU (멀티코어형 모바일 GPU의 작업 분배 및 효율성 분석)

  • Lim, Hyojeong;Han, Donggeon;Kim, Hyungshin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4545-4553
    • /
    • 2014
  • Mobile GPU has led to the rapid development of smart phone graphic technology. Most recent smart phones are equipped with high-performance multi-core GPU. How a multi-core mobile GPU can be utilized efficiently will be a critical issue for improving the smart phone performance. On the other hand, most current research has focused on a single-core mobile GPU; studies of multi-core mobile GPU are rare. In this paper, the job scheduling patterns and the efficiency of multi-core mobile GPU are analyzed. In the profiling result, despite the higher number of GPU cores, the total processing time required for certain graphics applications were increased. In addition, when GPU is processing for 3D games, a substantial amount of overhead is caused by communication between not only the CPU and GPU, but also within the GPUs. These results confirmed that more active research for multi-core mobile GPU should be performed to optimize the present mobile GPUs.

Characteristic Analysis and Fabrication of Bioceramic Scaffold using Mixing Ratios of TCP/HA by Fused Deposition Modeling (압출 적층 조형 기술을 이용한 TCP/HA 의 혼합비율에 따른 바이오 세라믹 인공지지체의 제작 및 특성 연구)

  • Sa, Min-Woo;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1273-1281
    • /
    • 2014
  • Tissue engineering is an emerging research field that has the potential to restore, regenerate and repair damaged bone tissue and organs. Tricalcium phosphate and hydroxyapatite biomaterials-based calcium phosphate are excellent materials that have both osteoconduction and biocompatibility for bone tissue regeneration. In this study, solution structures were successfully fabricated using a fused deposition modeling system based on deposition and heating devices. The morphology characteristics of the bioceramic scaffolds sintered at a temperature of $1,300^{\circ}C$ were analyzed by scanning electron microscopy. The effects of various blended TCP/HA ratio on the microstructure and shrinkage were studied. The mechanical properties of the scaffolds were measured using a compression testing machine from stress-strain curves on the crosshead velocity of 1 mm/min. The fabricated scaffolds were evaluated by cell proliferation tests of MG-63 cells. The results of this study suggest that the blended TCP(75 wt%)/HA(25 wt%) scaffold is an appropriate scaffold for bone tissue regeneration.

Development of the testing method for vinyl chloride monomer (VCM) in polyvinyl chloride(PVC) samples (PVC 제품에서의 염화비닐 단량체 정량분석 방법에 관한 연구)

  • Kweon, Deok-Jun;Choi, Ki-In;Eom, Hui-Jeong;Lee, Jae-In;Choi, Zel-Ho
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.395-401
    • /
    • 2012
  • This study presents a method for the quantitative analysis of residual vinyl chloride monomer (VCM) in PVC products. In elution solvent, the extraction efficiency was similar by ethanol, THF, and acetone, but using n-hexane, it indicated relatively low extraction efficiency. Measuring VCM in the pulverized PVC samples, it showed reasonable results in both the direct injection method and headspace method with GC/MS. Regarding analysis of VCM in the intermediate sponge samples, five laboratories showed good results, and from the results, it was considered that VCM quantitative method in this study was reliable.