• Title/Summary/Keyword: 측정학

Search Result 18,925, Processing Time 0.039 seconds

Uncertainty of Measurements in the Analysis of Vehicle Accidents (차량 사고 분석에서 측정의 불확실성)

  • Han, In-Hwan;Park, Seung-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.119-130
    • /
    • 2010
  • Reconstruction analysis of traffic accident is done by analyzing diverse data such as the road, accident traces and damage on the automobile. Most data can be a variable in the process of analysis, and measurement error of the data occurs from the investigator, tool and the given environment. Therefore, accident analysis always has some risks of measurement uncertainty. This research quantify the uncertainty in traffic accident analysis by conducting repetitive measurement experiments for variables with high probability of uncertainly such as length (i.e. geometric structure of the road, tire marks) and coefficient of friction. This paper also suggests an analysis result for the uncertainly of photographic observation of automobile crush measurement. These statistical distributions can help determine appropriate ranges for the input data in order to estimate the accident reconstruction uncertainty.

Transverse Profile Measurement of Proton Beam using the Beam Induced Fluorescence Monitor in KIRAMS-13 Cyclotron (Beam Induced Fluorescence 모니터를 이용한 KIRAMS-13 싸이클로트론의 양성자빔 횡단면 측정)

  • Nam, S.K.;Kim, K.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.418-425
    • /
    • 2009
  • To get the stable and optimized proton beam in the KIRAMS-13 cyclotron which installed in the regional cyclotron center, it is necessary to measure the transverse profile of proton beam. Beam Induced Fluorescence monitor is one of the non-destructive methods to measure the beam profiles, and it has many advantages such as a simple structure, real-time measurement, and minimum energy loss. The objective of this research is the design and development of Beam Induced Fluorescence monitor to measure the proton beam profiles in the KIRAMS-13 cyclotron.

A Study on Mean Flow Velocity Measurement by Cross Correlation of Ultrasonic Waves (초음파 상호상관 기법을 이용한 유체의 평균유속 측정 연구)

  • Kim, Chang-Ho;Lee, Dug-Ki;Paik, Jong-Seung;Jho, Moon-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.5-15
    • /
    • 1995
  • An application of the cross correlation technique by adopting ultrasonic waves for water pipe flow measuring purpose is studied. It is a non-intrusive flow metering method by determining the time of the flight of the flow turbulent noise and its non-obstructing mechanism enables to reduce process energy loss due to the flowmeter obstruction. A digital signal processor for the purpose of the real time Fourier transform was employed for the fast time calculation of the flow velocity. The overall accuracy was found as about $1\%$ for flow velocities from 0.25 m/s up to 16 m/s and for the pipe inside diameters from 50mm to 248mm. The cross correlation technique can be used for the tap water utility including most common liquid flows.

  • PDF

Self Compensating Flux-gate Magnetometer Using Microcomputer (마이크로컴퓨터를 이용한 자체 보상형 flux-gate 마그네토미터제작)

  • Ga, E.M.;Son, D.;Son, D.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.149-153
    • /
    • 2002
  • Flux-gate magnetometer has been still used for low field magnetic field measurement with portability, low power consumption, and high reliability. In many applications, flux-gate magnetometer measures not absolute values but changes of the earth magnetic field. For the eia magnetic field change measurements, we have constructed a high sensitive 3-axis flux-gate magnetometer of which measuring ranges is ${\pm}$1000 nT and noise level is 5pT/√㎐ at 1 ㎐. Using this magnetometer, we can compensate the earth magnetic field of ${\pm}$50,000 nT with successive approximation methods using microcomputer. After earth magnetic field compensation, we could measure earth magnetic field changes with ${\pm}$100 nT measuring ranges.

Cold Sensations by Examining Distribution of Cold spots on the Human Skin (체표각부위의 냉점분포 밀도 및 냉감각에 관한 연구)

  • Lee Young-Suk
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.2 s.27
    • /
    • pp.189-199
    • /
    • 1988
  • 착의행동을 일으키는 전단계의 감각으로서 국소의 냉감각과 체표 각 부위에 있어서의 냉점분포에 대하여 측정을 하였다. 피험자는, 냉점분포 측정에 한국인 여자 대학생 30명, 냉감각측정에는 한국인과 일본인 여자 대학생 8명을 대상으로 하였으며, 환경조건은 실온 $29^{\circ}C{\pm}1^{\circ}C$, 상대습도 $55{\pm}5\%$의 인공기후실로 하였다. 냉자격으로서는 $0^{\circ}C$의 냉각이 사용되었으며, 측정부위는 냉점분포 측정의 경우 체표 20부위, 냉감각 측정의 경우 체표 13부위로 하였고 측정결과는 다음과 같다. (1) 체표면의 냉점분포 밀도는 부위에 따라서 다르며, 체간부와 두부는 냉점분포 밀도가 높고 말단부에 갈수록 그 분포가 낮아졌다. 특히 가장 민감한 부위는 복부였다. 즉 체간부와 두부는 중핵온을 일정하게 보지하므로서 중핵부 체내온의 변화를 방어하기 위한 온도 수용 부위로서의 역할을 하고 있으며, 말초부는 냉점분포가 낮아서 기온에 따라 체표온(외각온)을 광범위하게 변화시키는 사지부의 온도정보입력의 역할을 담당하고 있다고 하겠다. (2) 각 부위에 있어서의 냉감각 순위는 일본인과 한국인 피험자간에 고도의 상관(r=0.93)이 보여져, 양 피험자군간에 차이는 볼 수 없었다. 3) 냉점분포 밀도가 높은 부위인 복부는 냉감각도 가장 민감하였으며, 냉점분포 밀도가 낮은 하퇴부는 냉감각 감수성도 낮게 나타났다. (4) 발바닥과 손바닥은 냉감각을 민감하게 느끼는 부위임에도 불구하고 냉점분포 밀도가 낮게 나타났으며, 이는 특수성이 있는 부위로서 주목되어지는 결과라고 하겠다.

  • PDF

Temperature and Pressure Measurement on the Flame Deflector during KSLV-I Flight Tests (나로호 비행시험을 통한 화염유도로의 온도 및 압력 측정)

  • Jung, Il-Hyung;Moon, Kyung-Rok;Kang, Sun-Il;An, Jae-Chel;Ra, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.4
    • /
    • pp.378-384
    • /
    • 2011
  • During the flight test of KSLV-I, various sensors are installed in the launch pad and the flame deflector to measure the flame characteristics and their influences on the launch complex when a launch vehicle lifts off. Parameter Measurement System is responsible for acquiring the above flight test data. The measurement methodology such as the configuration of measurement system, sensor locations and data acquisition procedures are presented. And this paper compares and explains the characteristics of data sets measured during two flight tests.

Practical Datasets for Similarity Measures and Their Threshold Values (유사도 측정 데이터 셋과 쓰레숄드)

  • Yang, Byoungju;Shim, Junho
    • The Journal of Society for e-Business Studies
    • /
    • v.18 no.1
    • /
    • pp.97-105
    • /
    • 2013
  • In the e-business domain where data objects are quantitatively large, measuring similarity to find the same or similar objects is important. It basically requires comparing and computing the features of objects in pairs, and therefore takes longer time as the amount of data becomes bigger. Recent studies have shown various algorithms to efficiently perform it. Most of them show their performance superiority by empirical tests over some sets of data. In this paper, we introduce those data sets, present their characteristics and the meaningful threshold values that each of data sets contain in nature. The analysis on practical data sets with respect to their threshold values may serve as a referential baseline to the future experiments of newly developed algorithms.

Compensation of Systematic Error of Various Schemes for Measuring Pumping Speed (진공펌프 배기속도 측정방식에 따른 구조적 오차 및 보정)

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.387-394
    • /
    • 2011
  • Standard devices and procedures for measuring the pumping speed, one of the most important parameters indicating the operation performance of the vacuum pump, have been developed and widely utilized. Though the standard system has a firm theoretical basis, it is, sometimes, inevitable to alter something in the system for a practical purpose compared with ideal conditions, which may lead to a large measurement error. In this paper, characteristics and systematic errors of various ideal or practical schemes for measuring the pumping speed are analyzed, and compensation terms are proposed.

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Development of instrument for measuring Home Economics-Pedagogical Content Knowledge(H-PCK) (가정교과교육학 지식(H-PCK)의 측정도구 개발)

  • Lee, Seung Jin;Yu, Nan Sook
    • Journal of Korean Home Economics Education Association
    • /
    • v.29 no.1
    • /
    • pp.35-56
    • /
    • 2017
  • The purposes of this study were to develop an instrument to examine the latent domains to measure H-PCK and verify the reliability and validity of the instrument. To accomplish these purposes, instrument item development, content validity, pilot study, and main study were conducted. The results were as follows. First, based on a review of extant literature, 29 items for H-PCK were developed. Seven items were deleted from the original instrument after determining content validity by 10 in-service Home Economics teachers, which resulted in the 22 items of 3 domains(Knowledge of perspective on Home Economics Education(KP), Knowledge of Home Economics curriculum(KC), Knowledge of Home Economics instructional strategies(KI)). Second, data were collected from 137 Home Economics teachers via mail survey for pilot study to establish reliabilities for each individual domain and across the domains based on Cronbach's ${\alpha}$ and item-total correlation. The result showed good reliabilities in the cut-off value of .7 and .5 for Cronbach's ${\alpha}$ and for item-total correlation respectively. Third, the main study was performed with 220 Home Economics teachers via e-mail survey and the reliability and validity tests were conducted. The reliability test results showed good reliabilities. The model for confirmatory factor analysis(CFA) provided a good fit to the data (e.g., CFI=.92, RMSEA=.06, SRMR=.05) to evaluate construct validity. The three domains of KP, KC, and KI demonstrated the acceptable convergent and discriminant validities in each individual domain and over domains. Thus, the instrument in this study may be utilized to measure H-PCK. Finally, criterion-related validity was performed to examine the extent to which the three domains are related to teacher efficacy with Pearson correlation (${\rho}$). It was relatively highly correlated at ${\rho}=.7$. In addition, the higher H-PCK the Home Economics teachers had, the higher teacher efficacy they had. The final instrument consisting of 22 items from 3 domains were determined through the entire procedure.