• Title/Summary/Keyword: 측정학

Search Result 18,925, Processing Time 0.043 seconds

Planar-type Sensor for Measuring the Time-varying Electric Fields (시변전장 측정용 평판형 센서)

  • Lee, Bok-Hee;Kil, Gyung-Suk
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.15-20
    • /
    • 1995
  • This paper deals with the planar-type sensor which can measure the time-varying electric fields. To make an electric field measurement system having a wide bandwidth, a planar-type sensor is proposed. The theoretical principle and design rule of the measuring device are introduced, and also the calibration and application investigations are carried out. From the calibration experiments, the frequency bandwidth of the electric field measurement device ranges from 160 [Hz] to 25 [MHz] and the sensitivity of the sensor is 1.2 [mV/V/m]. As the application experiments, the electric fields caused by the impulse and oscillating transient voltage in high voltage laboratory are measured by the proposed device, and the results are excellent.

  • PDF

A Study on the Method of Equilibrium-Pressure Prediction from Transient Data (과도상태의 압력데이터로부터 평형상태 압력 예측방법 연구)

  • Lee, Jong-Kook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.19-28
    • /
    • 2004
  • This study is concerned with the method of equilibrium-pressure prediction from transient data. Pressure measurement system consisted of pressure sensor and pressure tube. The surface orifice where pressure is measured is connected to a pressure sensor by a tube. In case of high orifice pressure, the pressure sensor responds rapidly to the orifice pressure. But when the orifice pressure is low the pressure sensor does not respond rapidly to the orifice pressure and time lag occurs seriously. Various test conditions are applied to investigate the time lag and to assess the methods of equilibrium-pressure prediction. The test time of the low-pressure measurement can be reduced by the method of equilibrium-pressure prediction of the present study.

Measurements and Statistical Modeling of Electromagnetic Noise from Electric Train (도시전철에서 발생한 전자파잡음의 측정 및 통계적 모형)

  • 심환우;윤현보;백락준;우종우
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.7
    • /
    • pp.37-47
    • /
    • 1995
  • In this paper, we have measured eletromagnetic noises from eletcric trains and the measurment data are treated statisticlly for monig. In order to measure the noise of electric tran, we set up an automatic measuring system andd measured the magnetic field over 9 kHz ~ 30 MHz range and electric field over 30 MHz - 1, 000 MHz range. The computer controlled measurint system yields efficiently experimental APD (Amplitude Probability distribution) data each of national rail road and subway train. The measured APD curves are analysed in terms of sensitivity study of Middleton's model through 6-parameter variation. Optimal parameters are obtained from measured data using Composite Approximation Algorithm.

  • PDF

Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers (접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향)

  • Choi, Ik-Hwang;Lee, Jae-Ik;Kwon, Goo-Do;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.358-363
    • /
    • 2008
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.

A Review of Self-Monitoring of Blood Pressure for Self-Management of Hypertension (고혈압 환자의 혈압자가측정에 관한 문헌고찰)

  • Park, Young-Lm;L.Cunningham, Susanna
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.13 no.1
    • /
    • pp.95-104
    • /
    • 2007
  • 연구목적: 고혈압환자의 효과적인 자가관리 간호중재를 개발하는데 필요한 기초자료로 혈압자가측정(self-monitoring of blood pressure)에 대한 특성, 장점, 범위 및 제한점을 파악한다. 연구방법: 1996년부터 2005년까지 PubMed에 수록된 고혈압환자의 자가관리 방법중 혈압자가측정방법이 포함된 외국의 연구를 중심으로 체계적인 고찰을 실시하였다. 전체 69개 자가관리방법을 적용한 논문 중에서 혈압자가측정이나 가정에서의 혈압측정(home monitoring)에 대한 45개 논문을 선정하여 분석하였다. 연구결과 전반적으로 혈압자가측정 방법은 고혈압환자의 혈압조절을 향상시키는 효과가 유의한 것으로 나타났다. 환자가 혈압을 자가측정한 방법에서 평균 혈압, 수축기 혈압, 맥압이 유의하게 감소한 것으로 보고되었다. 장기적 프로그램에서 혈압조절율이 향상되거나, 이완기혈압의 감소효과도 보고되었다. 혈압자가측정의 기준치는 연구마다 일치하지는 않았지만 135/85mmHg 수준이 정상혈압의 상한수준으로 제시되었다. 일부 연구에서는 가정 내 혈압측정이 24시간혈압측정을 대체하는 방법으로 추천되었다. 보다 정확한 혈압자가측정을 위해서 신뢰성 있는 혈압측정기구의 사용과 정확한 측정방법이 환자들에게 교육될 필요가 있다. 결론: 혈압자가측정은 고혈압환자의 혈압조절에 유용한 방법으로 고찰되었다. 또한 고혈압의 진단, 혈압치료와 고혈압 약물복용 행위를 향상시키는 교육적 효과도 긍정적으로 나타났다. 따라서 고혈압환자를 위한 효과적인 자기조절프로그램에 혈압자가측정법을 포함하는 것이 추천되며, 추후 한국에서 시도된 관련 연구에 관한 문헌고찰의 비교연구가 필요하다.

  • PDF

Analyses of the Basic Inquiry Process in Korean 3-10 Grade Science Textbooks: Focused on Observation and Measurement (우리나라 3-10학년 과학 교과서에 나타난 기초탐구과정 분석: 관찰 및 측정 탐구요소를 중심으로)

  • Park, Bo-Hwa;Kim, Hee-Kyong;Lee, Bong-Woo
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.5
    • /
    • pp.421-431
    • /
    • 2007
  • The purpose of this study was to examine the characteristics of observation and measurement inquiry process in the Korean science textbooks. For the inquiry process of observation, the higher grade textbooks contained more 'comparative observation' rather than 'simple observation'. Students should express their observation results in written words rather than verbal descriptions in the higher grade. For the inquiry process of measurement, the temperature measurement was the most frequent measurement activity. 'Measurement design' was found more frequently in the lower grade textbooks. The uses of measurement tools were not presented systematically and were presented restrictively when the relevant experiment wanted to use these tools. The higher grade textbooks include 'quantitative measurements' rather than 'qualitative measurements' and 'operation measurement' rather than 'simple measurement'. In the application of measurement results, we had difficulty in finding the activities related with the usage of unit, unit conversion, significant figure, error and uncertainty.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Variations in the Cusps of Mandibular Molars in Koreans (한국인 아래턱큰어금니 교두 변이에 관한 연구)

  • Yoo, Hong-Il;Kim, Ji-Hye;Kim, Sun-Hun
    • Anatomy & Biological Anthropology
    • /
    • v.27 no.3
    • /
    • pp.155-163
    • /
    • 2014
  • This study aimed to investigate the cusp size and morphological characteristics of permanent mandibular molars in Koreans with reference to the hypoconulid, and to analyze the differences and correlations between both sexes as well as between first and second mandibular molars. We obtained data from dental casts of 110 adults (78 males and 32 females). Mesiodistal and buccolingual diameters of first and second mandibular molars, the area of five cusps (protoconid, metaconid, hypoconid, entoconid, and hypoconulid), as well as the total cusp area and occlusal table area were measured. Paired t-test was performed to analyze the morphological differences between first and second mandibular molars and the sex differences between both sexes using SPSS program. Crown diameters and cusp areas of mandibular first molars were larger than those of mandibular second molars in both sexes. The hypoconulid was the most variable in size and morphological pattern among the five cusps, and the first molars showed a higher incidence of hypoconulid than the second molars. Except for the entoconid area of the first molar (p=0.06) and the hypoconulid area of the second molar (p=0.24), all other mean values were larger in males than in females, demonstrating a significant sexual dimorphism. These data suggest that the teeth which develop late in ontogeny tend to be smaller in size and more variable in morphological characteristics.

The measurements of thermophysical properties of ceramics by single rectangular pulse heating method in transient heat source (방형파펄즈가열법에 의한 세라믹스의 열물성 측정에 관한 연구)

  • Cha, K.O.;Lee, K.H.;Yim, Going
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.6
    • /
    • pp.612-620
    • /
    • 1999
  • Thermophysical properties of the high-dielectric ceramics were measured by a single rectangular pulse heating method. The values of thermal diffusivities, specific heats, and thermal conductivities were measured as a function of temperature ranging from room temperature to 1300 K.

  • PDF

패스워드 강도 측정 방법 연구 동향

  • Kim, KyoungHoon;Kim, Seung-Yeon;Kwon, Taekyoung
    • Review of KIISC
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2017
  • 오랜 기간 널리 사용되어온 패스워드 인증 기법은 여전히 대표적인 사용자 인증 수단이지만 그 사용성과 안전성 측면에서 여러모로 부정적인 부분이 많다. 일반적으로 사용자는 기억하기 쉽도록 간단한 패스워드를 선택하는 반면 서버는 추측공격에 대해 비교적 안전하도록 복잡한 패스워드의 사용을 권장한다. 취약한 패스워드의 사용은 전체 시스템의 안전에 큰 영향을 미치게 되므로 사용자가 패스워드를 선택하는 시점에 미리 패스워드의 강도 즉 안전성을 측정하여 피드백하기 워한 기법에 관한 연구가 다각적으로 이루어져 왔다. 또한 그 일부를 다양한 방법으로 시각화하여 이미 상용시스템에 적용하고 있다. 하지만 여전히 정확한 강도 측정과 안전한 패스워드의 사용성 제고를 위한 해결이 필요하며 따라서 이와 같은 패스워드 강도 측정 방법의 일반화를 위한 연구가 꾸준히 진행되고 있다. 본 논문에서는 텍스트 기반의 패스워드 강도 측정에 관한 연구동향을 살펴보고 분석한다.