• Title/Summary/Keyword: 측정조건

Search Result 9,339, Processing Time 0.037 seconds

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Evaluating the Accuracy of an OpenCV-Based Length Measurement Algorithm: The Impact of Checkerboard Type and Capturing Conditions (체커보드 종류 및 촬영조건에 따른 OpenCV 기반 길이측정 알고리즘 정확도 분석)

  • Kim, Hyeonmin;Kwon, Woobin;Kim, Harim;Kim, Hyungjun;Song, Seung Ho;Cho, Hunhee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.133-144
    • /
    • 2024
  • The OpenCV-based length measurement algorithm is anticipated to be effective for length measurement inspection tasks, providing objective inspection outcomes. Nonetheless, there is a notable gap in research regarding the influence of various checkerboard types and capturing conditions on the algorithm's accuracy in real-world construction settings. Consequently, this study proposes a methodology employing an OpenCV-based length measurement algorithm and checkerboard for digital construction inspection tasks. The findings suggest that using a checkerboard with square sizes of A4 or larger, and 50mm or larger, is optimal for capturing distances and angles within 4m and 90°, respectively, when deploying the algorithm. These insights are anticipated to provide practical guidelines for professionals conducting digital-based length measurement inspections.

Roughness Measurement of Hole Processing Surface for Mold Steel Using White Light Interferometer (백색광간섭계를 이용한 금형용 강재 구멍가공면의 조도 측정)

  • Lee, Seung-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • In this study, NIMAX material has been processed using the three-dimensional measuring instrument and white light interferometer. they were tested to roundness and surface roughness and results are as follows: As for a cutting characteristic, it indicated that F4 showed a lower result than 2F showed due to the high hardness of the material and showed a good result when spindle rotation speed and tool feed were low. As for the measurement of roundness through 3-Dimensional measuring machine, it indicated that 4F showed a good result like the condition of cutting component and that roundness showed a good result when spindle rotation speed of 1,700 rpm and tool feed speed of 85 mm/min were applied. As for the surface roughness of processing surface, Surface roughness showed better 4F than 2F and conditions of spindle rotation speed 1,700 rpm, tool feed rate 55 mm/min showed good results in the Ra $0.4025{\mu}m$.

A Study on the Appropriate exposure time for Flood discharge measurement of Surface velocity radar (전자파표면유속계의 홍수량 측정을 위한 적정 노출시간 검토)

  • Tae Hee Lee;Jong Wan Kang;Jae Hoon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.298-298
    • /
    • 2023
  • 전자파표면유속계는 홍수량 측정을 위해 사용되는 비접촉식 유속계로, 전자파를 발사한 후 수표면에 반사되는 전자파의 도플러 효과를 이용하여 표면유속을 측정하는 기기이다. 국제적으로 1980년대부터 홍수량 측정의 어려움을 극복하기 위해 하천 유량측정 업무에 활용하였다. 전자파표면유속계를 이용하여 정확한 표면유속을 측정하기 위해서는 측정 위치, 방향, 노출시간, 환경 등을 고려해야 한다. 여기서 노출시간은 표면유속 측정을 위해 전자파를 흐름 상태의 수표면에 노출시키는 시간을 의미한다. 특히, 노출시간은 유속에 따라 결정되며, 빠른 유속일수록 측정에 필요한 노출시간이 짧아진다. 그러나 노출시간이 너무 짧으면 측정 유속값이 부정확하거나 불안정해질 수 있으며, 반대로 너무 길면 수위 등 측정조건이 변화하여 측정값이 부정확해질 수 있다. 따라서 홍수량 측정을 위해 전자파표면유속계의 표면유속 측정의 적정한 노출시간을 설정해야 한다. 본 연구에서는 전자파표면유속계의 적정한 노출시간 검토를 위해 안동하천실험센터에서, 표면유속 최대 4.92 m/s에서 최소 0.457 m/s 범위의 19개 유속 조건에서 노출시간을 10초에서 40초까지 5초 간격으로 변화시키며 표면유속을 측정하였다. 현재 국내외 가이드라인에서 권고하고 있는 노출시간 30초에서 측정된 표면유속과 각 노출시간에서 측정된 표면유속의 정확도 검증을 통해 유사한 값을 가지는 표면유속을 검토하여, 수위변화에 대응하여 홍수량 측정을 위한 최소 노출시간을 검토하였다.

  • PDF

Comparison of Rock Young's Moduli Determined from Various Measurement Methods (다양한 시험법으로 규명된 암반 탄성계수 비교)

  • Ryu Kuen-Hwan;Chang Chan-Dong
    • The Journal of Engineering Geology
    • /
    • v.16 no.1 s.47
    • /
    • pp.1-14
    • /
    • 2006
  • Various measurements were carried out to estimate the modulus of deformation in two dominant rock types in Korea: granite and gneiss. Four most commonly used methods were utilized: Goodman jack tests, PS well logging, laboratory ultrasonic tests and laboratory uniaxial loading tests. Laboratory static and dynamic Young's moduli depend on the magnitude of the applied axial stress, range of Sequency used for measurement and the loading/unloading condition. As the laboratory measurement condition approaches to that in situ, the resultant moduli also appear to be comparable to that in situ. This suggests that the simulation of in situ stress condition is important when the modulus of rock is determined in the laboratory Dynamic Young's modulus is generally higher than static Young's modulus because of (micro)crack behavior in response to the stress, different range of frequency used for measurements, and the effect of the amplitude of deformation. Understanding of the relations in moduli from different measurement methods will help estimate appropriate in situ values.

증착 조건에 따른 OLED의 캐패시턴스 변화 연구

  • Na, In-Yeop;Kim, Gyu-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.155.2-155.2
    • /
    • 2015
  • OLED 소자 제작 과정에서는 증착 과정이 필요하다. 따라서 증착 과정에서의 변화도가 소자의 성능 및 수명에 큰 영향을 미친다. 이와 관련하여 소자 증착시 조건을 다르게 하여 OLED의 특성이 변함을 관찰하였다. OLED는 전자수송층, 정공수송층, 발광층과 이들을 중심으로 이들의 역할을 도와주는 보조층들로 이루어져 있다. 각각의 유기층들이 증착조건의 변화에 따라 어떤 변화가 있는지 캐패시턴스 측정을 통해 분석해 보았다. OLED에 전압을 걸고 측정한 캐피시턴스에 따라 구동 전압, 해당 전압에서의 변화 등을 분석하였다.

  • PDF

Indoor Comfort Conditions In A Habitat For Humanity House In Central Texas (미국의 중심부인 텍사스주에 위치하는 Habitat For Humanity House(평화주택)의 실내쾌적조건에 관한 연구)

  • Kim, Bong-Ae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.229-236
    • /
    • 2001
  • 이 논문은 미국의 중심부인 텍사스주에 위치하는 평화 주택의 실내외 환경을 측정하여 쾌적한 조건을 분석한 기초자료이다. 이 사례연구는 주택의 실내외온도, 습도, 그리고 이산화탄소농도를 측정하여 쾌적한 조건을 만드는 범위에 대하여 검토하였다. 이 논문은 또한 부가적인 비용의 증가 없이 평화 주택이 보다 쾌적한 실내환경을 계획할 때 이용할 수 있는 자료로 활용하는데 연구의 목적이 있다.

  • PDF

Representation of spatial variation and particle mean size for suspended sediment using acoustic backscatter in controlled channel experiments (수리실험을 통한 통제된 유사 조건에서의 횡방향 초음파도플러유속계 초음파산란도 활용 부유사농도 분포 및 평균 입경 분석)

  • Son, Geunsoo;Kim, Jongmin;Kang, Woochul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.252-252
    • /
    • 2022
  • 최근 기존의 전통적인 부유사채집기를 활용한 유사량 측정방법의 대안으로 지속적인 유량측정을 목적으로 활용되고 있는 횡방향 초음파도플러유속계의 초음파산란도를 활용하여 부유사농도를 측정에 대한 연구가 수행되고 있다. 하지만, 하천에서 횡방향 초음파도플러유속계를 활용한 유사량 측정 연구는 현장에서 측정된 자료를 기반으로 분석이 수행되기 때문에 통제된 유사 조건에서의 유사의 농도 및 입도분포에 대한 사전 정보를 바탕으로 정밀한 분석의 어려움이 있다. 이에 본 연구에서는 안동하천실험센터 순환수로에서 균일한 입도를 가지고 있는 황토를 활용하여 주입량에 따른 초음파산란도의 변화와 동시에 측정된 LISST(laser in-situ scattering and transmissometry)의 부유사 농도와 입도 자료를 활용하여 유사공급에 따른 3Mhz의 단일 주파수를 사용하는 횡방향 초음파도플러유속계의 초음파산란도를 활용한 부유사농도 및 평균입경의 측정에 대한 연구를 수행하였다. 측정결과, 유사공급에 따라서 초음파산란도를 활용하여 부유사농도가 증가하는 경향을 나타내고 있었으며, 횡방향 초음파도플러유속계로부터 측정된 셀별 초음파산란도를 활용하여 부유사농도의 공간적인 분포의 분석이 가능함을 확인할 수 있었다. 그리고 유사감쇄계수를 활용하여 LISST로부터 측정된 평균입경과의 관계식을 개발하여 유사공급에 따른 평균입경의 변화를 측정할 수 있을 것으로 나타났다. 추후, 통제된 조건에서의 다양한 입도분포에 따른 실험을 통해 횡방향 초음파도플러유속계의 초음파산란도를 활용한 부유사농도 측정 정확도를 개선과 유사감쇄계수를 통해 평균입경을 측정하는데 활용이 될 것으로 판단된다.

  • PDF

Evaluation of image Quality for Radiographic positioning using IEC Radiation Quality & Clinical condition (IEC 선질과 임상조건을 이용한 방사선영상의 품질평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.177-178
    • /
    • 2015
  • 디지털방사선영상시스템의 영상 품질을 비교하기 위해 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 잡음력 스펙트럼(NPS)을 이용하여 영상 품질평가를 하였다. IEC61267 선질을 사용하여 IEC62220-1에서 제시하는 기하학적인 조건과 실제 임상에서 사용되어지는 기하학적인 조건을 사용하여 그리드 및 부가필터, 임상선량을 이용하여 edge 팬텀을 사용하여 MTF, NPS값을 측정하였다. 그리드사용 유 무, 부가필터사용 유 무, kV, 임상선량(mAs), 영상검출기까지의 거리에 따른 MTF 결과는 임상조건 100cm, 180cm과 IEC62220-1 기하학적인 조건 150cm에서 MTF 공간주파수 측정값은 비슷하게 나타났으며, 오히려 임상조건 100cm에서 공간주파수가 높게 나타나는 경우도 있었다. NPS 결과는 선량(mAs)이 증가함에 따라 감소함을 나타내었다. IEC61267 선질을 이용한 영상품질평가에서는 IEC62220-1기하학적인 조건을 이용한 품질평가보다 임상조건 기하학적인 조건을 사용한 영상의 품질이 좋았다. 본 논문의 영상특성 평가 연구 결과들을 바탕으로 향후 IEC 표준의 영상평가에서 제시하는 평가방법보다는 임상 조건을 적용한 영상특성 평가방법을 적용한다면 실제 임상의 디지털방사선영상시스템의 영상품질을 적절하게 유지할 수 있을 것으로 사료된다.

  • PDF

Proposal of the Measurement Conditions for Hanji-Determination Folding Endurance (한지 내절 강도 시험의 측정조건 제안)

  • Kim, Myoung Nam;Kim, Ji Won;Son, Ha Nuel;Jeong, Sun Wha
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.689-700
    • /
    • 2021
  • This study aims to optimize the measurement conditions of handmade Hanji paper to reduce the time required for measurement while meeting folding endurance standards, for various basis weights. Thirteen types were selected, including 12 types of Hanji with grammages of 17 g/m2, 30 g/m2, and 45 g/m2, and one type of 75 g/m2 copy paper, and 24 sheets were prepared in the laid and chain directions. Subsequently, folding endurance experiments at different load (14.72 N, 9.81 N, 4.91 N) and specimen width conditions (15 mm, 10 mm, 5 mm) were performed, using a 4-MIT folding endurance tester. The results showed that, for specimen widths of 15 mm and 10 mm under a load of 4.91 N, the folding endurance falls within the reference range (10~10000 times). In particular, reduced folding endurance range and measurement time were observed at a width of 10 mm under a load of 4.91 N. Moreover, the endurance trend lines based on the average values of load and specimen width ranges enabled the prediction of the folding endurance within those ranges, according to the decreasing slope. Furthermore, for a specimen width of 15 mm under a load of 4.91 N, the folding endurance in the comparison group (35 to 17723 times) significantly exceeds the upper limit of the reference range (10~10000 times). Therefore, the measurement conditions of 4.91 N with a specimen width of 10 mm are proposed.