• Title/Summary/Keyword: 측정물체

Search Result 720, Processing Time 0.027 seconds

A Study on the Measurement of Tissue Blood Flow by the Self-Mixing Effect of Laser Diode (레이저 다이오드의 자기혼합 효과를 이용한 조직혈류 측정에 관한 연구)

  • Ko, Ran-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 1994
  • This paper describes the measurement of tissue blood flow by the the self-mixing effect of laser diode. A Laser doppler signals due to the moving object and the tissue blood flow were detected by the self-mixing effect of laser diode. The Doppler shifted frequency was changed linearly with the driving frequency of moving object and was increase after the exercise. The results of in-vivo experiment were consistent with the result of exercise physiology.

  • PDF

Design of auto voice warning system using bluetooth and ultrasonic sensor (블루투스와 초음파 센서를 이용한 자동음성 경보 시스템 설계)

  • Park, Joon-Hoon;Kim, Jin-Min;Park, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.377-378
    • /
    • 2008
  • 본 논문은 시각 장애인들의 보행 시 앞을 볼 수 없는 점을 바탕으로 시각을 음성으로 대체하여 장애 물체가 발생하였을 경우 안전을 위하여 위험 요소를 사전에 경보하여 알려주도록 구현하였다. 시각 장애인들이 보행 시 장애 물체가 나타났을 경우 이를 입체 변위 센서인 초음파 센서로 장애물의 위치를 측정하고 측정된 거리 데이터를 근거리 무선통신인 블루투스를 동하여 송 수신하여 사용자인 시각 장애인에게 소형 스피커를 통하여 음성으로 알려주고 경고함으로써 위험 요소를 사전에 대처할 수 있도록 설계를 하였다. 초음파 입체 변위 센서를 이용하여 측정된 거리를 실시간 자동 거리 측정이 가능하도록 시스템을 구현하고 이 데이터를 근거리 무선 통신으로 송 수신하며 수신 모듈이 데이터를 음성으로 전환하여 실시간 자동 경보 시스템을 구축함으로써 보행 장애 위험물 감지가 보다 효율적으로 이루어지고 디지털화되게 시스템을 개선하였다.

  • PDF

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF

Design and implementation of a X-band Doppler radar sensor using the homodyne detection (호모다인 검파방식을 이용한 X-밴드 도플러 레이더 센서의 설계 및 제작)

  • 장남영;최평석;은재정
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.75-82
    • /
    • 2001
  • In this paper, a transmitter and a receiver using a Gunn diode and SBD was designed and fabricated in X-band. This system detects Doppler shift signal reflected by moving target through the homodyne detection, which is Doppler radar sensor for the measurement of the velocity of moving target. By the experimental results, the oscillating condition of the transmitter was satisfied at about the half wavelength between the supporting post of the Gunn diode in the waveguide and the waveguide short. And using the fabricated Doppler radar sensor, the velocity measurement deviation of moving target was 1.24%.

  • PDF

Quantitative Interpretation of Holographic Fringe by Using Phase Shifting Method and Digital Image Processing (위상변이법과 디지탈 영상처리를 이용한 홀로그래피 간섭무늬의 정량적 해석)

  • 고영욱;권영하;강대임;박승옥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1728-1735
    • /
    • 1992
  • Holographic interferometry technique has been used for the measurement of whole-field deformation with high sensitivity. However there are some difficulties in quantitatively analyzing the holographic fringes. Recently, quantitative and automatic fringe analysis by using phase shifting method in interferometry has been studied in many fields. In this paper, a real time holographic interferometry system and a phase shifting method combined with digital image processing technique are employed to record and quantitatively analyze holographic fringe patterns. To evaluate our system and analyze errors, comparison of measured deformation with theoretical deformation of cantilever beam was carried out. The accuracy of 4.5% in our system was verified We have tried to apply this method to quantitatively measure the deformation of turbine blade under the bending force.

Measurements of the Trajectories of Moving Objects with Video System and Image Matching (비디오 시스템과 영상매칭에 의한 운동물체의 거동측정)

  • 이창경;조우석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.3
    • /
    • pp.331-341
    • /
    • 2002
  • In order to extract 3-dimensional information from 2-D image, stereo images are prerequisite. Moreover, for the measurement of moving objects, the synchronized sequential stereo images have to be captured and image matching should be implemented for determining the location of moving objects. In this research, a simple method computing 3-dimensional coordinates from sequential images of moving objects was implemented. The sequential stereo images were captured by a video camera with a beam splitter. Once video images were digitalized by frame grabber, the interest points were extracted and matched in each stereo image, and the coordinates of center of them are calculated using weighted average method. Then, 3-dimensional coordinates of moving objects were computed by DLT algorithms.

Noncontact optical system for measurement of displacement and vibration (미소 변위 진동측정을 위한 광학 시스템 설계 및 제작)

  • Hwang, Woong;Kwon, Jin-Hyuk
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.260-265
    • /
    • 2003
  • A noncontact optical system that can measure displacement or vibration of an object is designed by employing the oblique ray method. By using a single convex lens which serves as both the input and output lenses, we made the optical system very compact and reliable. In addition, the bandwidth of the vibration measurement is more than 100 KHz by using the position-sensitive detector as the beam position sensor. The resolution and capture range of the system are $\pm$1 ${\mu}{\textrm}{m}$ and 1100 ${\mu}{\textrm}{m}$, respectively. As a sample test, the vibrations of a speaker and a rotating compact disc surface were measured.

Acceleration of Phase Measuring Profilometry using GPU (GPU를 이용한 위상 측정법의 가속화)

  • Kim, Ho-Joong;Cho, Tai-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2285-2290
    • /
    • 2017
  • Automation systems are evolving in many areas of industry in recent years. At the same time, the necessity of the height inspection of the object by the 3D measurement is gradually increasing. Among the various 3D measurement methods, this paper discusses phase measuring profilometry(PMP). The PMP is a method of obtaining the height of an object using the phase value of the fringe pattern. Since the PMP is an algorithm requiring a large amount of computation, a method for efficiently solving the problem is needed. In this paper, we propose to use CUDA from NVIDIA to solve this problem. We also propose using pinned memory and streams provided by CUDA. This can greatly improve the measurement speed while maintaining accuracy. Finally, we demonstrate the performance of the proposed method through experiments.

3-D Object Representation Using Part-based Superquadric Model from Range Image (부품 기반의 superquadric 모델을 이용한 거리 영상으로부터 3차원 물체 표현)

  • Lee, Seon-Ho;Kim, Tae-Eun;Choe, Jong-Su
    • The KIPS Transactions:PartB
    • /
    • v.8B no.2
    • /
    • pp.201-207
    • /
    • 2001
  • 3차원 물체표현은 컴퓨터 비젼 분야에서 중요한 역할을 차지하고 있다. 본 논문에서는 체적 표현법의 일종인 부품기반의 superquadric 모델을 통하여 3차원 기계 부품 물체를 표현하는 기법을 제안하였다. 이러한 부품기반의 superquadric 모델은 크기, 이동, 회전, 그리고 변형 등의 유한개의 계수들만을 가지고 다양한 3차원 체적소의 형상 표현이 가능하다는 장점이 있다. 따라서, superquadric 형상복구 과정을 통해서 이들 superquadric 계수들을 추출함으로써 3차원 단일 체적소 표현이 가능하다. 이때, 형상복구 과정의 입력은 3차원 거리 데이터로, 형상복구 과정은 3차원 nfcp를 이루는 각 체적소에 속하는 거리 데이터들을 입력으로하는 적합도 측정함수의 최소 자승법(LSM)에 의해 이루어진다. 이후에 3차원 물체 각 체적소에 해당하는 superquadric 계수들을 얻는다. 결과적으로 3차원 전체 물체에 해당하는 superquadric 모델은 이들 각 체적소에 해당하는 계수들의 집합으로 표현된다. 컴퓨터에서 합성한 합성영상과 실제 거리영상에 대한 실험을 통해 제안한 방법의 유용성을 입증하였다.

  • PDF

The Change of the Accommodative Amplitude in Accordance with the Color of the Spectacle Lens or Object (안경 렌즈 및 물체의 색상에 따른 최대 조절력 변화)

  • Oh, Byung Ha;Lee, Jae Ho;Jung, Sea Hun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.119-124
    • /
    • 2008
  • Purpose: To determine whether the accommodation of amplitude (AA) was changed by the color of the spectacle lens or object. Methods: AA was measured in forty subjects in their 20s when they viewed different targeton-background color combination with achromatic, gray, brown or green lens. Minus-lens procedures were used for the estimation of AA. Results: When subjects viewed the black-on-white, red-on-white and green-on-white targets, AA under tinted lens tended to be increased compared with AA under achromatic lens. Especially, the green lens significantly increased AA whatever the color of target was. Furthermore, as subjects viewed the green target, AA was the highest irrespective of the color of lens. AA was also changed depending on the color of background, so AA on the red background was lower than on the white background. On the contrary, AA on the green background was higher than on the red or white backgrounds. Of tinted lens, the gray lens increased AA the lowest, but the green lens did the highest. The number of subjects, whose AA were measured more than 9 D, reached to 12.5% with the gray lens, 21.3% with the brown lens, 22.5% with the green lens on the green background, but 5%, 6.5% and 6.5% on the red background, respectively. Conclusions: This results showed that AA varied depending on the color of spectacle lens, objects or background, and the eye fatigue could be decreased with proper color of spectacle lens accordingly.

  • PDF