Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Deposition of Polycyclic Aromatic Hydrocarbons on Tree Leaves (다환방향족 탄화수소의 나뭇잎 침착)

  • Yoo, Shi-Gyun;Kim, Tae-Wook;Chun, Man-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.116-121
    • /
    • 1999
  • Tree leaves have been used as the passive sampler to measure lipophilic PAHs in the atmosphere. This is a convenient and economical method in case of sampling at many regions including the remote places that are not supplied with electric power. But poor results can be obtained if samples are collected carelessly or PAHs concentrations are calculated on the basis of wrong natures of tree leaves. This study was performed to avoid the errors of interpretation that can be induced by these problems when tree leaves are used as a passive sampler of PAHs. Conclusions have been reached as follows: 1) The correlativity was low among the water content, the lipid content, the dry weight and the area of four kinds of tree leaves. According to this, PAHs concentrations calculated per wet weight, dry weight, lipid content and area of tree leaves differed. Therefore, same unit shoud be used to describe concentrations of the pollutants when PAHs concentrations deposited on leaves from atmosphere in the different regions are compared. It is better to decribe the unit as PAHs concentrations per dry weight of leaves for comparison with other data because almost researcher make use of this unit, and the range of fluctuation of the dry weights in several natures of tree leaves was relatively little during growing seasons. 2) Although four kinds of trees(Pinus Koraiensis, Ginkgo biloba, Evodia daniellii, Kalopanax pictus) had been grown at the same place, PAHs concentrtions deposited on leaves differed respectively. Therefore PAHs concentrations deposited on different kinds of tree leaves should not be compared. It is better to make use of pine needles as the sample because pine trees grow almost over the world, and it is able to collect their samples in winter.

  • PDF

신선농산물 생산에서의 농약오염과 농약폭로-흡수 -일본을 중심으로-

  • 최진옥
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2000.04a
    • /
    • pp.14-15
    • /
    • 2000
  • 현재의 농업에서 농약의 사용은 불가결한 것이다. DDT의 등장으로 농약만능시대의 막이 열린 이래 세계에서 10만종 이사의 농약이 탄생했다. 현재 전세계의 생산량은 매년 1천만 톤을 넘어섰고 일본의 경우 등록되어 있는 농약수는 원체(화합물종류)로서 367종, 상품명으로서는 약 5800 종류가 판매되고 있다. 년간 일본의 농약생산량은 약 60만 톤으로 농약의 수출량과 수입량이 거의 같기 때문에 생산량이 사용량에 상당하는 것으로 본다. 농약의 식품오염의 측면에서 보면, 단위 면적당 세계 제 1위의 농약 사용국인 일본은 시장에 유통되고 있는 농작물에도 상당한 양의 농약이 잔류하는 것으로 본다. 물론 식품위생법에 26종의 농약에 대해 53작물을 대상으로 하는 잔류농약기준이 있지만, 농약성분이 400종 이상이며 산포 대상이 되는 작물은 53작물보다 훨씬 많다. 또한 한 두 종류의 작물밖에 대상이 되지 않는 농약도 많아서 잔류농약기준은 식품의 안전성 확보면에서는 부족한 것이 많아. 따라서 농산물 생산자 스스로가 농약사용기준을 정확하게 지켜주기를 바랄 뿐이다. 한편으로는, 이러한 현실에 비추어서 농약사용이 일상화된 농업자에게 있어 농약으로 인한 건강상의 문제 또한 적지 않다. 농업자의 건강관리 대책의 일환으로 실시하는 건강진단 및 조사에 따르면, 만성적인 질환뿐만 아니라 농약산포작업후에 나타나는 증세(기침, 피부이상, 불쾌감, 두통, 인후염, 구토)를 경험한 작업자는 예방의학적인 견지에서 농업자의 농약폭로실태파악 및 교육을 해오고 있으나 그다지 설득력을 얻지 못하여 보다 확실한 인체내 흡수량을 측정하는 방법을 생각하게 되었다. 즉 뇨중 농약 대사물을 폭로지표로 하는 생물학적 모니터링(biological monitoring)을 시도, 농업현장에 있어서의 그 실증과 유용성에 대한 검토를 하고자 하였다. 농작업 가운데서 가장 위험하다고 보는 농약산포작업 (수동식 분무기를 이용한 하우스작물 및 동력분무기를 사용한 노지작물)을 대상으로 생물학적모니터링을 실시한 결과 업자의 뇨로부터 농약의 체내흡수를 반영하는 농략의 뇨 분비성 대사물을 측정할 수 있었다. 즉 뇨나 혈액등의 생체시료를 이용한 생물학적모니터링의 농약에의 응용은 서구와는 달리 대부분이 규제가 없는 소규모 자가영농으로 정해진 농약사용지침보다 많은 농약을 사용한다거나, 또는 개인의 습관이나 작업환경에 따라 폭로조건이 달라서 실질적인 폭로-흡수의 정도가 불분명한 경우등에도 충분히 대응할 수 있어 농약사용자 개개인의 농약 폭로-흡수의 정도를 분명하게 밝힐 수 있다. 게다가 평가의 결과를 농약사용의 일선에 있는 농업자에게 피드백 하여 주므로서 농약에 대한 인식을 새롭게 하고 농약취급시의 건강장해예방행동을 촉구하는 등의 효과도 높은 것으로 예방의학적인 유용성이 크다고 볼 수 있다.

  • PDF

Measurement of Spatial Scattered Dose Distribution According to Presence or Absence of Radiation Shielding in the Operating Room (수술실에서 방사선 차폐기 사용 유무에 따른 공간산란선량분포의 측정)

  • Do, Sang-Lock;Cho, Pyong-Kon;Kim, Seong-Jin;Jung, Dong Kyung
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.549-556
    • /
    • 2017
  • This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by $30^{\circ}$ in the interval of the radius 50 cm on the height of 95 cm based on the head of the patient, and it was measured by increasing $30^{\circ}$ with the interval of 50 cm in the vertical side of each horizontal side. In the same method, the radiation shielding was installed and measured. The result of measurement shows that the horizontal side of 50 cm distance was $0^{\circ}$, $90^{\circ}$ and $180^{\circ}$, was $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, and $2.69{\pm}0.15mSv/h$ in the $270^{\circ}$ direction, and was $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, and $1.37{\pm}0.11mSv/h$ after the use of the radiation shielding. In addition, the vertical distribution in horizontal direction $90^{\circ}$ with 50 cm distance was $30^{\circ}$, $60^{\circ}$, $120^{\circ}$, was $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, and $5.40{\pm}0.22mSv/h$ in $150^{\circ}$, and was $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, and $1.92{\pm}0.13mSv/h\;mR/h$ after the use of the radiation shielding. Both direction showed decrease according to the use of the radiation shielding. Therefore, radiation related workers who work in operating rooms should recognize the spatial scattered dose distribution exactly and need to try to prevent the risk of radiation exposure with proper protective measures.

A Novel in Vitro Method for the Metabolism Studies of Radiotracers Using Mouse Liver S9 Fraction (생쥐 간 S9 분획을 이용한 방사성추적자 대사물질의 새로운 체외 측정방법)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Dong-Hyun;Lee, Sang-Yoon;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.325-329
    • /
    • 2004
  • Purpose: Usefulness of mouse liver S9 fraction was evaluated for the measurement of the metabolites in the in vitro metabolism study of $^{18}F$-labeled radiotracers. Materials and Methods: Mouse liver S9 fraction was isolated at au early step in the course of microsome preparation. The in vitro metabolism studies were tarried out by incubating a mixture containing the radiotracer, S9 fraction and NADPH at $37^{\ciirc}C$, and an aliquot of the mixture was analyzed at the indicated time points by radio-TLC. Metabolic defluorination was further confirmed by the incubation with calcium phosphate, a bone mimic. Results: The radiotracer $[^{18}F]1$ underwent metabolic defluorination within 15 min, which was consistent with the results of the in vivo method and the in vitro method using microsome. Radiotracer $[^{18}F]2$ was metabolized to three metabolites including $4-[^{18}F]fluorobenzoic$ acid within 60 min. It is likely that the one of these metabolites at the origin of radio-TLC was identical with the one that obtained from the in vivo and in vitro (microsome) method. Compared with the in vitro method using microsome, the method using S9 fraction gave a similar pattern of the metabolites but with a different ratio, which can be explained by the presence of cytosol in the S9 fraction. Conclusion: These results suggest that the findings of the in vitro metabolism studies using S9 fraction can reflect the in vivo metabolism of novel radiotracers in the liver. Moreover, this method can be used as a tool to determine metabolic defluorination along with calcium phosphate absorption method.

Risk Factors in Stability after Immobilization of the Distal Radius in Unstable Fractures in Children (소아 요골 원위부 불안정 골절의 캐스트 후 안정성에 영향을 미치는 요소)

  • Shin, Yong-Woon;Sohn, Jong Min;Park, Sang-Yoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.215-223
    • /
    • 2021
  • Purpose: Distal radius fractures in youth are treated conservatively in most cases, but there are some cases of redisplacement in the follow-up period after cast immobilization, even after complete reduction. This study examined the risk factors of redisplacement in reduced unstable distal radius fractures. Materials and Methods: From February 2011 to June 2018, 44 unstable distal radius fractures were managed with a closed reduction and cast immobilization. The patients were aged between 6 and 14 years. The cases of redisplacement were analyzed with the fracture characteristics (fracture obliquity, fracture level ratio, ulnar fracture combined), cast qualities (gap index, cast index, 3 point index, and radius-2nd metacarpal angle) and host factors (age, sex). Results: The mean angulation in the union was 9.2° (0°-32.8°). In the categorical grouping 29 cases were within 10° angulation, and 15 cases were more than 10°. No significant differences in the factors of the cast indices or host factors were noted. The meaningful factor was the fracture level calculated by the relative width of the fracture site divided by the sum of width of diaphysis and epiphysis (p=0.001) and combined ulnar fracture (p=0.019). Conclusion: Unstable distal radius fractures should be treated with more stubborn guidelines lest the fracture loses its anatomical alignment. In particular, in patients with less remodeling power, operative treatment would secure a better result if the fracture occurs in a more proximal location.

A Design of a Planar UWB Antenna with Notched WLAN band by Using Slot and Slit (슬롯과 슬릿을 사용하여 무선랜 대역이 제거된 평면형 UWB안테나 설계)

  • Lee, Chang-Joo;Kim, Su-Hoon;Park, Young-Bon;Lee, Mun-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.6
    • /
    • pp.105-110
    • /
    • 2012
  • In this paper, A planar UWB antenna with notched WLAN band, 802.11a band (5.15 ~ 5.825GHz), by using slot and slit is designed by using CST Microwave Studio. The notched bandwidth can be controlled by the length and width of the slot and slit in the patch and ground plane and it's radiation characteristics are examined through the experiments. The bandwidth based on the -10dB return loss level can be covered the full UWB band (3.1 ~ 10.6GHz) with a notched WLAN band (5.147 ~ 5.83GHz). Also, the experimental radiation pattern is almost omnidirectional in the H-plane.

The Evaluation Method of Software Usability based on UI (UI 중심의 소프트웨어 사용성 평가 방법)

  • Lee, Ha-Young;Yang, Hae-Sool
    • Journal of Digital Convergence
    • /
    • v.11 no.5
    • /
    • pp.105-117
    • /
    • 2013
  • Viewpoint about the quality of software is various. But, from the end-user point of view, user interface of software may be all to express the quality of software. But the detailed evaluation criteria were not established about usability evaluation method based on user interface so far, though user interface of software is the main object of usability quality characteristics. In this paper, we established a system about the method extracting and evaluating some quality characteristics elements measurable form user interface of software by analyzing the relationship between the elements constructing quality characteristics and user interface related to quality evaluation of software. We expect that this result of study will be a fundamental study adapting and evaluating to various types of user interface.

Daylight color temperature to match 60W LED lighting system development for the interior general Lighting (주광의 색온도와 일치하는 실내 전반 조명용 60W LED 조명제품 개발)

  • Kim, Jin-Hong;Lim, Su-Keun;Park, Joung-Wook;Kim, Gi-Hoon;Song, Sang-Bin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.197-200
    • /
    • 2009
  • 주광의 색온도와 일치하는 실내 전반 조명용 60W급 LED 조명제품 개발하기 위하여 실내 주광에 적합한 LED를 선정하고, 색온도, 광색제어를 위한 구동회로 및 제어회로를 설계 제작 하였다. 그리고 1W급 Cool White, Warm White Package LED 총 168 EA를 적용하여 주광의 색온도와 일치하는 실내전반 조명용 LED 조명 System 을 개발하였다. 주광의 색온도와 일치하는 실내 전반용 LED 조명제품은 60W급 LED SMPS 구동회로 및 광색/색온도 제어회로 설계, 면발광을 위한 방열 설계 및 기구 구조 설계를 통하여 개발되었으며, 직접 시제품을 제작하고 그 성능을 측정하였다. 그 결과 회로 효율은 85% 이상, 색온도는 $3,000{\sim}7,000K$에서 실시간으로 제어 가능 하고, 원하는 색온도을 구현 할 수 있도록 하였으며, 발산각 또한 최대 광도의 1/2 기준으로 $100^{\circ}$ 이상을 만족시켰다.

  • PDF

Calculation of Geoidal Height refered to Bessel Ellipsoid From EGM96 Model (EGM96 모델을 이용한 Bessel 지오이드고의 계산)

  • 최경재;최윤수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • In order to calculate geoidal height refered to Bessel ellipsoid, methods to translate geoidal heights from a certain coordinate system to an arbitrary system with the corresponding ellipsoid are studied. and geoidal heights refered to Bessel ellipsoid were computed from EGM96 Model refered to GRS80 using iteration method pro-posed in this paper. Transformation parameters between WGS84 and Bessel were calculated using geoidal heights computed from iteration method. The result of coordinate transformation(standard deviation) were 0.009 second in latitude and 0.006 in longitude and 0.393m in orthometric height.

  • PDF