• Title/Summary/Keyword: 측정기준면

Search Result 484, Processing Time 0.031 seconds

Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs) (광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정)

  • Im, In-Chul;Yu, Yun-Sik;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • This study used the optically stimulated luminescence dosimeters (OSLDs), recently, received the revaluation of usefulness in vivo dosimetry, and the diode detecters to measure the skin dose of patient with the rectal cancer. The measurements of dose delivered were compared with the planned dose from the treatment planning system (TPS). We evaluated the clinical application of OSDs in radiotherapy. We measured the calibration factor of OSLDs and used the percent depth dose to verified, also, we created the three point of surface by ten patients of rectal cancer to measured. The calibration factors of OSLD was 1.17 for 6 MV X-ray and 1.28 for 10 MV X-ray, demonstrating the energy dependency of X-ray beams. Comparison of surface dose measurement using the OSLDs and diode detectors with the planned dose from the TPS, The skin dose of patient was increased 1.16 ~ 2.83% for diode detectors, 1.36 ~ 2.17% for OSLDs. Especially, the difference between planned dose and the delivery dose was increased in the perineum, a skin of intense flexure region, and the OSLDs as a result of close spacing of measuring a variate showed a steady dose verification than the diode detecters. Therefore, on behalf of the ionization chamber and diode detecters, OSLDs could be applied clinically in the verification of radiation dose error and in vivo dosimety. The research on the dose verification of the rectal cancer in the around perineal, a surface of intense flexure region, suggest continue to be.

The comparison between measurement and prediction values for the vertical illuminances by relux program in the survey region (상용 조명해석 프로그램(Relux)을 이용한 가로등 주택침입광 예측값과 실측값 비교)

  • Jung, Dae-Kwan;Park, Hyung-Kyu;Jung, Joon-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.98-104
    • /
    • 2018
  • The assessment of the light trespass in terms of light pollution is difficult due to the complexity of light environments. As a result, the light pollution research has examined the influences of light pollution using simulation program such as RELUX. However, there still exists a differences between the real measurement value and the simulation value for the light trespass. In this paper, we analyzed the light trespass using the RELUX simulation program, and compared results with real measurement values. In this study, the regions (Seoul, Incheon, etc.) were investigated regarding the light trespass for outdoor lighting. The survey of vertical illuminance was analyzed measuring point (more than 2 point) out the window that was expected to light trespass for the higher anticipated to illumination. The illuminational predicted values for the RELUX program were compared with maximum one. As a result of this study, the illuminational errors between the measurement values and predicted values for the simulation were examined from -0.97 lx to 0.65 lx except 2.08 lx and -7.70 lx. The light trespass was analyzed the higher by how much the located close to the height, length, width of the outdoor lighting for the window. For measuring predicted values using RELUX, it was not sufficiently considered in the simulation conditions because of environmental factors and investigator error etc. Limitations of this study include the limited number of measurements, and greater field data is required in future studies.

A MORPHOMETRIC STUDY ON THE PRIMARY MOLARS AND PREFORMED STAINLESS STEEL CROWN (유구치 치관 및 기성금속관의 크기에 관한 계측학적 연구)

  • Choi, Ji-Eun;Cheong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.355-362
    • /
    • 2001
  • Data derived from odontometric studies are useful in many areas. Especially crown diameter of primary teeth is important in not only anthropology but also clinical dentistry. The purposes of this study were to compare diameters of primary molars of Korean children with those of preformed stainless steel crown, and examine racial characteristics of primary molars of Korean children. The mesiodistal and buccolingual diameters of primary molars were measured on dental casts taken from 235 children(male 105, female 131), with digital calipers. And the data were compared with those of preformed stainless steel crowns. The results were as follows; 1. No significant difference was observed between the right and left members of antimeric teeth and all primary molars of male were larger than those of female. 2. The diameters of primary molars of Korean are smaller than those of Austrailian aborigines and there was significant difference between diameters of primary molars of Korean and those of other populations. 3. There were size differences between diameters of maxillary, mandibular first molar and preformed stainless steel crown than other primary molars, relatively.

  • PDF

Effect of Anorthite Glass Frit on the Electrical and Adhesion Properties of Photosensitive Silver Paste (Anorthite 글라스 프릿이 첨가된 감광성 은 페이스트의 전기적 특성 및 부착력 특성 평가)

  • Lee, Eun-Heay;Kim, Hyo-Tae;Lim, Jong-Woo;Yoon, Young-Joon;Kim, Jong-Hee;Park, Eun-Tae;Lee, Jong-Myun;Paik, Un-Gyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.21-21
    • /
    • 2009
  • 후막 광식각 기술을 이용하여 형성된 Ag 전극과 LTCC 기판 사이의 접착력을 향상시키기 위하여 무기 바인더로서 anorthite, diopside 및 MLS-62 glass frit을 첨가하여 감광성 Ag paste를 제조하였다. 소성 후의 glass pool effect를 감소시키기 위해 attrition mill을 통하여 미세 glass 분말을 준비하였다. Glass frit은 Ag powder의 5vol%~25vol%의 함량으로 첨가하여 감광성 Ag paste를 제조하였고 패턴 형성 후 $850^{\circ}C$에서 1시간 소결하였다. 전극과 기판 사이의 접착력은 micro-ball shear test 법으로 측정하였으며, Ag 전극 부착력은 glass frit의 함량 증가에 따라 증가하다가 감소하는 경향을 보이는데, 이는 과량의 glass frit 첨가로 인한 전극 내부에 액상 풀의 형성에 기인한 것으로 보여진다. Ag 전극의 면저항은 glass frit의 함량이 증가함에 따라 $0.13m{\Omega}{/\square}$에서 $2.06m{\Omega}{/\square}$까지 증가하는 경향을 나타내었다. 소성 전후의 전극 패턴의-수축율은 $100{\mu}m$의 선폭을 기준으로 glass frit의 첨가랑이 증가할수록 43.3%에서 35.0%로 감소하였으며, 그 결과 최소 선폭 $25{\mu}m$의 미세 전극 패턴의 형성이 가능하였다.

  • PDF

The Ultraviolet Generation Characteristics of porcelain and Polymer Insulators by Corona Discharge (코로나 방전에 의한 자기 및 폴리머 애자의 자외선 발생특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.147-152
    • /
    • 2008
  • This paper describes the breakdown poperties of porcelain and polymer insulators using the UV camera. The experiment was carried out using condition of voltage at the KS C IEC 60060-1(2006). As these results, corona discharge in porcelain insulator was generated the weakness point of insulator union. And the corona discharge of polymer insulator happened in union of power source. Also, we could confirm easily weakness part of these insulators by ultraviolet image through the corona discharge. Besides, in the comparison with the exciting technique of ultrasonic detection, it confirmed that deterioration steps are corrected. These steps are possible to judge the deterioration of power facilities through reliable date. Hereafter, this study as the diagnostic technology suitable for the sites is used.

Design and Manufacture of Modified Circular Ring antenna for WLAN/WiMAX Applications (WLAN/WiMAX 시스템에 적용 가능한 변형된 원형 링 안테나 설계와 제작)

  • Lim, Dae-Soo;Yoon, Joong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.268-275
    • /
    • 2014
  • In this paper, a dual-band circular ring monopole antenna with stub and ground slot for WLAN(Wireless Local Area Networks)/WiMAX(World interoperability for Microwave Access) applications. The proposed antenna is based on a planar monopole design, and composed of one circular ring of radiating patch, cross strip in circular ring, modified feed line, and two rectangular slot in the ground plane for triple-band operation. To obtain the optimized parameters, we used the simulator, Ansoft's High Frequency Structure Simulator(HFSS) and found the parameters that greatly effect antenna characteristics. Using the obtained parameters, the antenna is fabricated. The numerical and experiment results demonstrated that the proposed antenna satisfied the -10 dB impedance bandwidth requirement while simultaneously covering the WLAN and WiMAX bands. And characteristics of gain and radiation patterns are determined for WLAN/WiMAX application.

Numerical Discussion on Natural Convection in Soils (지반내 자연대류에 대한 수치해석적 논의)

  • Shin, Hosung
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.2
    • /
    • pp.35-47
    • /
    • 2017
  • Thermal behavior of soils is mainly focused on thermal conduction, and the study of natural convection is very limited. Increase of soil temperature causes natural convection due to buoyancy from density change of pore water. The limitations of the analysis using fluid dynamics for natural convection in the porous media is discussed and a new numerical analysis is presented for natural convection in porous media using THM governing equations fully coupled in the macroscopic view. Numerical experiments for thermal probe show increase in the uncertainty of thermal conductivity estimated without considering natural convection, and suggest appropriate experimental procedures to minimize errors between analytical model and numerical results. Burial of submarine power cable should not exceed the temperature changes of $2^{\circ}C$ at the depth of 0.2 m under the seabed, but numerical analysis for high permeable ground exceeds this criterion. Temperature and THM properties of the seafloor are important design factors for the burial of power cable, and in this case effects of natural convection should be considered. Especially, in the presence of heat sources in soils with high permeability, natural convection due to the variation of density of pore water should be considered as an important heat transfer mechanism.

Study on Sediments' Release for Water Characteristics in Agricultural Reservoirs (농업용저수지의 수질 특성에 따른 퇴적물의 용출 영향 연구)

  • Lee, Jin Kyung;Choi, Sun Hwa;Lee, Seung Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.499-499
    • /
    • 2016
  • 본 연구는 오염된 농업용 저수지에 대하여 수층에 따른 수질 변화 특성을 조사하고, 저수지 저부의 퇴적물에 대한 용출 실험을 통해 수층별 수질 특성이 퇴적물의 용출에 미치는 영향을 분석하고자 수행되었다. 연구 대상 저수지의 선정은 설치년도 1960년대를 기준으로 이전과 이후로 분류하였으며, 주요 오염원을 축산계와 생활계 오염원으로 분류하여 각 다른 특성을 가진 저수지를 선정하여 조사하였다. 내부 오염 부하량이 수체에 미치는 영향을 평가하기 위해 실시한 용출량 실험 결과, 호기 조건에서 축산계오염원 저수지의 T-P가 미미하게 용출이 일어난 것을 제외하고는 생활계, 축산계오염원 저수지에서 용출이 일어나지 않았다. 반면에 혐기 조건의 경우에는 생활계오염원 보다는 축산계오염원 저수지에서, 1960년대 이후 설치된 저수지에서 보다는 1960년대 이전에 설치된 저수지에서 용출이 크게 일어나는 것으로 조사 되었다. 혐기 조건에서 T-N의 경우 생활계오염원과 1960년대 이후 설치된 저수지에서는 용출이 일어나지 않았으나, 그 외의 항목에서는 모두 용출이 일어나는 것으로 분석되었다. 특히 혐기조건에서는 모든 연구대상 저수지에서 T-P의 용출이 크게 일어나는 것으로 조사되었는데, 이는 부영양화의 주요 영향인자로 작용할 수 있으므로 저수지 저부의 혐기조건이 형성되는 것을 제어?관리해야 할 필요성이 있다고 하겠다. 연구 저수지에 대한 현장 조사 결과, 가뭄의 영향으로 수위가 평년에 비해 상당히 낮았으며, 저수량의 부족으로 저수지 주변의 바닥이 드러나거나 유출이 없는 등의 특징을 보였다. 수심이 낮은 5~7월의 조사 시기에는 표층의 DO 농도가 높음에도 저층부의 DO 농도는 1.2~2.2 mg/L를 나타내 약혐기조건이 형성됨을 확인하였다. 또한 현장측정기(HYDROLAB_Quanta)를 이용한 DO측정시, 저층부 퇴적물의 재부유를 막기 위해 저층경계면에서 30~50cm 윗부분을 측정했다는 점에서 저층부 바닥면의 DO 농도가 더 낮을 수 있다고 추정할 수 있다. 이는 이 시기에 퇴적층에 존재하는 오염물질의 용출이 충분히 일어날 수 있으며, 이후 8~11월에 수계 내 환란 및 순환에 의해 오염물질이 수중으로 이동하게 되고, 수질을 악화시키는 원인으로 작용할 수 있음을 추론할 수 있다. 이와 같이 퇴적되어 있던 오염물질이 계속적으로 용출 및 순환을 해마다 반복한다면 해당 저수지는 장기간 수질 오염 저수지가 될 수밖에 없을 것이다. 따라서 이러한 내부오염부하가 크다고 판단되는 저수지에 대하여 오염퇴적물의 관리가 필요하다고 하겠다.

  • PDF

An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab (터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구)

  • Woo Jin Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.262-269
    • /
    • 2023
  • Purpose: In this study,fire-resistance test were executed to evaluate the effectiveness of the fireproof panel attached to the PSC slab in tunnel. Method: For the fire resistance test, the RWS curve was applied and the furnace of the KICT was used. Result: As a result of the experiment, the maximum temperature measured on the concrete surface of the PSC slab with the fireproof panel was 321.8℃, which was lower than the damage limit temperature of 380℃ for concrete. Also, at the t=25mm, the maximum temperature was 35.2℃, which was lower than the damage temperature of steel, 250℃. The use of precast fire resistance panel(t=30mm) improves fire resistance of PSC structures. Conclusion: As a result of the test, a reinforcement method for attached a fireproof panel in case of fire in a tunnel or an underground roadway is provided to protect a structure from fire. In the future, it is necessary to perform the static performance test of the slab to which the fireproof panel is attached, and to confirm the adhesion performance of the fireproof panel by performing the pull-off test and the fatigue test.

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.