• Title/Summary/Keyword: 측정(measurement)

Search Result 20,197, Processing Time 0.039 seconds

Transmit-Beam Pattern Measurement of the Active Phased-Array Antenna Using Near-Field Measurement Facility (근접 전계 시험 시설을 이용한 능동 위상 배열 안테나 송신 빔 패턴 측정)

  • Chae, Hee-Duck;Kim, Han-Saeng;Lee, Dong-Kook;Jeong, Myung-Deuk;Park, Jong-Kuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1155-1164
    • /
    • 2011
  • In this paper, we proposed the transmit beam measurement method of active phased array antenna, which is installed in Korea's first developed naval medium range radar, using near-field measurement facility. The pulse-mode high power characteristics of active phased array antenna's trasmit-beam make it difficult to measure with general near-field measurement facilities where low power continuous RF signals are used. Thus, in this paper, the measurement method of active phased array antenna's transmit beam in conjunction with the near-field measurement facility, which is suitable for the high-power transmit beam measurement, and PNA-X network analyzer(Agilent Technologies), which can support pulse-mode measurement, was proposed and measured by near-field measurement techniques. And the EIRP(Effective Isotropic Radiated Power), the transmit characteristic of active phased array antenna, was measured by the near field measurement techniques and compared to numerical estimation which was nearly equal with small difference of 0.1 dB.

Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography (컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구)

  • Lee, Seung-Young;Hong, Joo-Wan;Kang, Su-Mi;Kim, Su-Bin;Joon, Sang-Hoon;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.713-720
    • /
    • 2019
  • The purpose of this study was to propose a new measurement method for accurate measurement of vessel diameter in computed tomography angiography(CTA). CTA test was performed after non-ionic iodine contrast agent was flowed at a constant rate to self-maded perfusion phantom. After obtaining raw data, images were reconstructed with multi-planar reconstruction(MPR) and maximal intensity projection(MIP). Diameters of vascular models were measured for each technique. Relative and conventional measurements were then compared. The mean diameter of the vascular model was closer to the actual measurement when relative measurement was used compared to that when conventional measurement was used both in MPR and MIP. Relative measurements of MPR and MIP were closer to actual measurement than those of conventional measurement (34% VS, 24%, p<0.05). The relative measurement method proposed in this study was closer to the actual measurement than the conventional measurement method. However, both test methods were still larger than actual results. Therefore, further study of relative measurement method is needed using this study as basic data.

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Method for Measuring Dielectric Constant of Planar Dielectric Substrate (판형 유전체의 유전율 측정 방법)

  • Lee, Chang-Hyun;Kwon, Taek-Sun;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.799-804
    • /
    • 2018
  • In this paper, a method for measuring the dielectric constant of a planar dielectric substrate using the free space material constant measurement method in a general measurement environment is proposed. Two horn antennas and a network analyzer were used for S-parameter measurement and the transmission and reflection coefficients of a planar dielectric substrate were calculated from the measurement results. To obtain a reliable dielectric constant in a low-precision-measurement environment, only the magnitude of the transmission coefficient, which has a small error due to the measurement environment, is used for dielectric constant estimation. Finally, the dielectric constant is determined by comparing the measured results at different frequencies.

A Study on Ship Motion Measurement System Using ADIS16480 Inertial Measurement Unit (ADIS16480 관성측정장치를 이용한 선체 운동 측정 시스템에 관한 연구)

  • Kim, Daejeong;Yim, Jeong-Bin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.270-270
    • /
    • 2019
  • Although the Inertial Measurement Unit is applied to a variety of applications such as ships, submarines, and aircrafts, it is mainly used in the attitude measurement area. But since such equipment is expensive, it has been used only in special fields. In this study, the ship's seaworthiness is verified by measuring the speed, direction, gravity, and acceleration of the ship in real time using a low-cost Inertial Measurement Unit. A research method for estimating fIuid force coefficients was devised. Therefore, this study measured ship motion factors at sea, processed and analyzed the measured data, and evaluated the overall safety of the ship and estimated the resistance and steering performance of the ship.

  • PDF

Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients (재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발)

  • Kang, Min-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.

Children's Strategies for Measurement Estimation of Rectangular Covering Tasks (직사각형 덮기 과제를 해결하면서 나타난 초등학생의 어림 측정 전략)

  • Lee, Jong-Euk
    • The Mathematical Education
    • /
    • v.49 no.3
    • /
    • pp.375-387
    • /
    • 2010
  • The focus of this article is the strategies young children use to solve rectangular covering tasks before they have been taught area measurement. seventy nine children from Grade 1 to 4 were observed while they solved various array-based tasks, and their drawing and explanation were collected and analyzed. Children's solution strategies were classified into incomplete covering, inadequate array, array constructed from moveable unit, measurement of one dimension, measurement of two dimension, and calculation. Implications for the learning of area measurement are addressed.

Analysis of Patent Trends for Body Size Measurement Technology (신체 치수 측정기술 특허 동향 분석)

  • Jeon, Young-Ju;So, Ji-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.209-213
    • /
    • 2021
  • For the human body shape information, body measurement techniques using a tape measure or image analysis are used. However, there is a demand for a method with high measurement accuracy and reproducibility while being simple. In this paper, domestic and foreign patent research related to body size measurement technology was conducted to identify the development trend of the related technology. WISDOMAIN DB was used to search for patents published in Korea, the United States, Japan, and Europe, and valid patents were derived by defining the technical scope of major and medium classifications and sub-categories. For the derived patents, patent trends by year, major applicants by country, and the status of technological fields were analyzed. In the field of body size measurement technology, the proportion of patent applications filed in Korea is high, indicating that Korea is leading the patent application in this field. Although the number of patent applications in the field of sensor-type measurement technology was not large, it has an advantage in measurement simplicity, so the development of related technology is expected to contribute to the improvement of measurement accuracy related to body composition analysis.

Accelerometer-based Drag Measurement in a Shock Tunnel (충격파 터널에서의 가속도계 기반 항력 측정)

  • Jang, Byungkook;Kim, Keunyeong;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.489-495
    • /
    • 2020
  • An accelerometer-based system was designed and constructed for drag measurement in a shock tunnel. Drag coefficient of a conical model was measured under a Mach 6 flow condition. A simple and intuitive calibration method was presented to compensate for the friction force of the drag measurement system, and the results of the measurement were compared with computational fluid dynamics in which the simple conical model was analyzed. The influence of drag measurement interference by supports of various shapes was identified and the design was presented to minimize. The drag coefficient measurement using the modified support showed that the error of the drag coefficient by the support was decreased.

A Review of Temperature Measurement of Fire Driven Flow Using Thermocouple - Measurement Bias (열전대에 의한 화재유동의 온도측정에 관한 검토 - 측정오차)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.98-103
    • /
    • 2010
  • A series of fire experiments have been performed to examine the measurement bias of the bare bead thermocouple widely used in fire testing and analyze the measurement bias of bare bead thermocouple comparing with the measured temperature using the aspirated thermocouple. The measured temperature of the bare bead thermocouple was lower than that of the aspirated thermocouple in the hot upper layer while it showed opposite trends in the upper layer. Also, the bare bead thermocouple showed higher measurement bias in the lower layer rather than upper layer in the compartment fire. The maximum relative percentage error of the bare bead thermocouple against the aspirated thermocouple reached 250% in the present study. The present study points out the need of correction process of the measured temperature by bare bead thermocouple for improving the reliability of the fire tests.