• Title/Summary/Keyword: 측정(measurement)

Search Result 20,161, Processing Time 0.043 seconds

A Study on the Image-Based Luminance Measurement System Using the Measuring Position (측정 위치를 고려한 영상기반 휘도측정시스템에 관한 연구)

  • Sun, Eun-Hey;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.4
    • /
    • pp.424-429
    • /
    • 2014
  • In this paper, an image-based luminance measurement system(LMS) is proposed to measure the luminance of outdoor signboards. We design the LMS that can improve disadvantages of efficiency of the point-luminance meter and portability of face-luminance meter using the image of DSLR camera and print out the luminance value by using the proposed luminance analysis algorithm in real time. Outdoor signboards have various size and shape, and are also installed on the various place. Luminance of the signboard is influenced by measurement location, angle, color, etc. Therefore, we measure the change of luminance value in accordance with measurement location for accurate luminance measurement and then consider the luminance value according to the measurement distance. We obtain a numerical relation between luminance value and measurement location. The proposed LMS is verified through comparative experiment with point-luminance meter.

Study on Measurement Program in each Maturity Level of CMMI (CMMI 성숙도 레벨 별 측정 프로그램에 관한 연구)

  • Yu Young-Moo;Han Hyuk-Soo
    • The KIPS Transactions:PartD
    • /
    • v.12D no.1 s.97
    • /
    • pp.91-102
    • /
    • 2005
  • In the past it was generally felt that software quality was the same as product quality. But as the software industry is getting bigger and more complex, it has become hard to develop quality software that meets customers' needs just depending on product quality. Therefore, lately many domestic and foreign companies are making efforts to upgrade product quality by implementing Process Improvement. Measurement in Process Improvement activities enhances the effect of Process Improvement, and also identifies and helps the activities. In support of this paper, research on the measurement program was conducted based on the CMMI adopted by many domestic and foreign companies for their process improvement model. MA process area that deals with measurement process setup is one of the CMMI process areas and was the basis of the structure of the measurement program. This study presents differences of the measurement program for each level of CMMI and how to apply it. The results of this study can help a business to apply CMMI-based Process Improvement by backing up the structure of the measurement program. Furthermore, it can offer a roadmap for progress of the measurement program for each level.

A Study on A Spacecraft Alignment Measurement System (위성체 얼라인먼트 측정 시스템에 관한 연구)

  • Park, Hong-Chul;Son, Young-Seon;Choi, Jong-Yeon;Yoon, Yong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.98-104
    • /
    • 2004
  • A spacecraft alignment measurement requires highly precise measurement accuracy which is less than ${\pm}0.5^{\circ}$. In general, such an alignment measurement has been performed by using three or more theodolites. However, it contains the latent accuracy error because of a position stability of spacecraft, etc. The new alignment measurement system which consists of a theodoilte, a rotating table and a digital inclinometer has been developed to possibly to possibly reduce the error. This paper describes the concept and methodology of methodology of measurement system. It was found that new measurement system can provide more accurate results than the conventional system.

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

Optimal Design of Flow Measurement System Using Turbine Flowmeter (터빈유량계를 이용한 유량 측정 시스템의 최적 설계)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The turbine flowmeter is selected for high precision and reproducibility at the time of flow rate measurement but causes various uncertainty factors of measurement in the difference between the standard environmental condition at calibration and the environmental condition at the site. Also, a reliable interpolation method is required for use in sections other than calibrated measurement values. Therefore, in this paper, in order to improve the reliability of the flow rate measurement, we designed and manufactured a device that accurately measures the output signal of the turbine flowmeter, interpolates the value of the calibrated result value, and corrects the temperature change in real time We confirmed the reliability of the measurement at the site to carry out the performance verification.

The study for the applications of the measurement system assessment in statistical process control (통계적 공정관리 추진시 측정시스템 평가의 실시방법에 관한 연구)

  • 민철희;백재욱
    • The Korean Journal of Applied Statistics
    • /
    • v.11 no.1
    • /
    • pp.13-28
    • /
    • 1998
  • Corrent measurement system assessment is crucial in helping improve process or quality. In this article, we would like to apply several methods of measurement system assessment in statistical process control. Specifically, focus is on accuracy, precision (both repeatability and reproducibility included), and stability of the measurement process.

  • PDF

A New Available Bandwidth Measurement Technique with Accurate Capacity Estimation (정확한 고정대역폭 추정을 통한 새로운 가용대역폭 측정 기법)

  • Cho Seongho;Choe Han;Kim Chong-kwon
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.4
    • /
    • pp.495-507
    • /
    • 2005
  • Measuring the end-to-end available bandwidth in the Internet is a useful tool for distributedapplication services or QoS (Quality-of-Service) guarantee. To measure the end-to-end available bandwidth, Single-hop Gap model-based packet train measurement techniques are well-known. However, the error of packet train output gap can happen by network topologies. This error of the output gap causes the inaccuracy of the available bandwidth measurement. In this paper, we propose a new end-to-end available bandwidth measurement technique with accurate capacity measurement and fast convergence methods. To solve the erroneous capacity measurement problem of the back-to-back packet train transmission, we propose a new available bandwidth measurement method by decoupling the capacity measurement with the initial gap of the packet train. Also, we propose a new technique to predict the proper initial gap of the packet train for faster convergence. We evaluate our proposed method by the simulation in various topologies comparing with previous methods.

The effect of noise and doppler for range measurement of low orbit satellite using tone method (톤 방식을 사용한 저궤도 위성 거리 측정에서의 잡음과 도플러 영향 분석)

  • 김영완;박동철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.641-650
    • /
    • 2000
  • The effects of noise and doppler for low orbit satellite range measurement using tone method are represented in this paper. Also the optimal noise bandwidth of range signal detection circuit which is used for range measurement system of KOMPSAT is proposed. Based on the effects of satellite orbit parameters via the deduction of dynamic motion characteristics of low orbit satellite and signal to noise spectral density of range measurement signal, the effects of noise and doppler for range measurement system are analyzed. The effect of satellite link noise is decreased, but the effect for doppler is increased as the PLL noise bandwidth of range signal detection circuit is increased. The validation of analyzed effect is verified via comparison of measurement results of KOMPSAT's range measurement system and simulation results in environments of low orbit satellite.

  • PDF

A Study on Measurement Accuracy of A Theodolite System(V) - A Measurement System Accuracy depending on the distance from theodolite system to target Bars (데오드라이트 시스템의 측정 정확도에 대한 연구(V) - 타켓 바의 거리에 따른 측정 정확도)

  • Yoon Yong-Sik;Lee Dong-Ju
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.13-21
    • /
    • 2005
  • The affected factors for an accuracy of theodolite system are not only the measurement environment of temperature, illumination, etc. but also the measurement processes of the distance between two theodolites, the distance from theodolite system to scale bar and the distance from theodolite system to targets. We have known that the best collimation distance between two theodolites and the best distance from theodolite system to scale bar is $3{\sim}4m$. This study was performed for searching the best distance from theodolite system to targets on above measurement configuration. And, we could know that the best distance from theodolite system to targets is $2{\sim}6m$ and the system accuracy could be within ${\pm}0.025mm$.