• Title/Summary/Keyword: 측면선량

Search Result 172, Processing Time 0.028 seconds

400 MeV/nucleon 12C Ions Shielding Benchmark Calculations using MCNPX with Different Nuclear Data Libraries (400 MeV/nucleon 12C 이온의 MCNPX 와 핵자료를 이용한 차폐 벤치마킹 계산)

  • Shin, Yun Sung;Kim, yong min;Kim, dong hyun;Jung, nam suk;Lee, hee seock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.295-300
    • /
    • 2015
  • There are various type of particle accelerators such as Kyoungju 100-MeV proton beam accelerator in Korea. And Korea plans to build large particle accelerator such as heavy ion accelerator and 4th generation light source facility. The accelerated high energy particles of these facility produce 2nd neutron after nuclear reaction with target materials. And then these 2nd neutron activate structural materials and surrounding environment. Accordingly, it is important to consider the activation and shielding calculation on design of facility for safety operation. In this study, we tried to calculate and compare the neutron flux from the interaction $^{la}150$ beam with target material(Cu) according to thickness of iron and concrete shielding material by MCNPX 2.7 with nuclear library JENDL/HE 07and la150. To verify the properties of nuclear library, we compared computational results with experimental value. These results can be used for dose evaluation technology in planning of the shielding of large particle accelerator.

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

A Methodology for Determining the Optimal Durations of the Use of Contaminated Crops As Feedstuffs of Cattle Following a Nuclear Accident (원자력 사고후 가축 사료로서 오염 농작물 이용에 대한 최적기간 결정 방법론)

  • Hwang, Won-Tae;Han, Moon-Hee;Choi, Yong-Ho;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.65-72
    • /
    • 1999
  • A methodology for determining the optimal durations of the use of contaminated crops as feedstuffs of cattle was designed based on the cost-benefit analysis method. The results of application for pigs, an omnivorous cattle, were discussed for the hypothetical deposition of radionuclides on August 15 when a number of crops are fully developed in Korean agricultural conditions. For investigating the relative cost-effectiveness of the use of contaminated crops as feedstuffs, the net benefit was compared with the case of the direct disposal of contaminated crops. The time-dependent radionuclide concentration in crops after the deposition was predicted using a dynamic food chain model DYNACON. The net benefit from the actions was quantitatively evaluated in terms of cost equivalent of doses and monetary costs of implementing the action. It depended on a number of factors such as radionuclides, variety of crops supplied as feedstuffs and duration of the actions. The use of contaminated crops as feedstuffs was more cost effective for $^{90}Sr\;or\;^{131}I$ deposition than for $^{137}Cs$ deposition.

  • PDF

Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images (Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구)

  • Park, Justin C.;Park, Sung-Ho;Kim, Jin-Sung;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Shin, Jung-Suk;Park, Hee-Chul;Ahn, Yong-Chan;Song, Willian Y.
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2010
  • To generate on-board digital tomosynthesis (DTS) for three-dimensionalimage-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT), two clinical cases (liver and bladder) were selected to illustrate the capabilities of on-board DTS for IGRT. DTS images were generated from subsets of CBCT projection data (45, 162 projections) using half-fan mode scanning with a Feldkamp-type reconstruction algorithm. Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information. Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Digital tomosynthesis might allow targeting of the treatment volume on the basis of daily localization.

Radiation Safety Management Guidelines for PET-CT: Focus on Behavior and Environment (PET-CT의 방사선안전관리 가이드라인 개발: 행위와 환경을 중심으로)

  • Jung, Jin-Wook;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • Our purpose is to specify behavior and environmental factors aimed at reducing the exposed dosage caused by PET-CT and to develop radiation safety management guidelines adequate for domestic circumstances. We have used a multistep-multimethod as the methodological approach to design and to carry out the research both in quality and quantity, including an analysis on previous studies, professional consultations and a survey. The survey includes responses from 139 practitioners in charged of 109 PET-CTs installed throughout Korea(reported by the Korean Society of Nuclear Medicine, 2010). The research use 156 questions using Cronbach's ${\alpha}$ (alpha) coefficients which were: 0.818 for "the necessity of setting and installing the radiation protective environment"; 0.916 for "the necessity of radiation protection", "setting and installing the radiation protective environment"; and 0.885 for "radiation protection". The check list, derived from the radiation safety management guidelines focused on behavior and environment, was composed of 20 items for the radiation protective environment: including 5 items for the patient; 4 items for the guardian; 3 items for the radiologist; and 8 items applied to everyone involved; for a total of 26 items for the radiation protective behavior including: 12 items for the patient; 1 item for the guardian, 7 items for the radiologist; and 6 items applied to everyone involved. The specific check list is shown in(Table 5-6). Since our country has no safety management guidelines of its own to reduce the exposed dosage caused by PET-CTs, we believe the guidelines developed through this study means great deal to the field as it is not only appropriate for domestic circumstances, but also contains specific check lists for each target who may be exposed to radiation in regards to behavior and environment.

A Study on the Permeability Reduction Methods of the Riverbed Ground during Urban Railway Tunnel construction (도시철도터널공사 시 하저통과구간의 지반투수저하 공법에 대한 연구)

  • Kim, Joon-Jeong;Cho, Kook-Hwan;Lee, Jun-Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.551-557
    • /
    • 2007
  • This paper describes a study on the permeability reduction of the riverbed ground during urban railway tunnel construction. The research is mainly concentrated on the study of the grouting or injection methods among permeability reduction methods which can be adapted in the riverbed ground. Firstly, the various grouting methods are theoretically reviewed and compared based on the previous research papers and case study results. It is also evaluated the grouting methods in view of a safe construction of the river crossing railway tunnel. Baced on the literature review and previous construction data, the design technology of grouting methods considering the long term hydro-geological behaviour in the riverbed, is suggested. Two injection methods namely, Natural Durable Stabilizer(N.D.S) and Space-Multi Injaction Grouting(S.M.I) methods, are introduced as new approach methods which can be adopted to modify the riverbed ground. In order to evaluate the ground that grouted and modified by the N.D.S and S.M.I method, the pilot test programmes including the field and laboratory permeability tests, are carried out in the river crossing tunnel construction sites. The results obtained from pilot test programme, are also reviewed. In conclusion, the grouting efficiency of the S.M.I method using the non-alcalimeter silica sol is better than that of NDS method using cement. In addition, it hopes that the research results are contributed to develop the grouting design technology.

  • PDF

A Study on Case for Localization of Korean Enterprise in Indonesia (인도네시아 진출 한국기업의 현지화에 관한 사례 연구)

  • Swo, Min-Kyo;Kim, Hee-Jun
    • International Commerce and Information Review
    • /
    • v.15 no.4
    • /
    • pp.481-508
    • /
    • 2013
  • The purpose of this study is to research the specific ways of successful localization by analyzing the success and failures case for localization through the theoretical background and the strategic models of localization. The strategic models of localization are divided by management aspects such as the localization of production and sourcing, the localization of human resources, the localization of marketing, the localization of R&D, harmonious relationship with the local community and authority transfer between headquarters and local subsidiaries. And the specific measures of the successful localization are proposed within the framework of the strategic models by comparing and analyzing the success and failures case for localization of individual companies operating in Indonesia. The results indicate that there are successful companies which develop a suitable products for the local climate and failed automobile company which is weak for assembly of complete vehicle in terms of localization of production and sourcing. In case of localization of human resources, most companies recognize the importance of this part and endeavor to secure superior human resource through a related education. It is found that most of the companies perform R & D in their native country. In part of a harmonious relationship with the local community, Korean companies should contribute to the community and be friendly with local residents and make a good image of the company focusing on the cultural environment. In aspect of authority transfer between headquarters and local subsidiaries, there is a tendency to be determined by the head office rather than the joint participation. In the future, in order for Korean enterprise to be successful one in Indonesia market, a highly interdependent and complex forms between headquarters and local subsidiaries shall be performed and an active exchange of information and the selection of best talent regardless of nationality shall be promoted.

  • PDF

Study on the Breast Tissue Uptake according to Body Temperature on Molecular Breast Imaging (Molecular Breast Imaging 검사 시 체온 변화에 따른 유방 섭취율에 관한 고찰)

  • Kim, Ji Hyun;Baek, Song Ee;Oh, Shin Hyun;Ham, Jun Cheol;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.20-24
    • /
    • 2019
  • Purpose Molecular Breast Imaging (MBI) scan is used in nuclear medicine, for which $^{99m}Tc-sestaMIBI$ is administered by intravenous injection. However, the breast uptake rate of $^{99m}Tc-sestaMIBI$ is less than 1% of the total dose administered, relying on blood flow conditions of organs. The purpose of this study is to evaluate the impact of changes to body temperature on the uptake of $^{99m}Tc-sestaMIBI$ in breast tissue. Materials and Methods We investigated 30 breast cancer patients who performed more than one follow-up MBI scan. All scans were acquired by Discovery 750B (Genral Electric Healthcare, USA). $^{99m}Tc-sestaMIBI$ injected with 740 MBq (20 mCi), after 60 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. The follow-up examination was then classified into 15 body temperature control group and 15 body temperature non-control group, and gained breast image in the same way as before. The breast uptake rate was analyzed in the MLO View of the opposite side of the lesion, and blind images were evaluated. Results The breast uptake rate increased by 30.31% in the body temperature control group and it was statistically significant(P<0.05), and 0.96% in the body temperature non-control group, and it was not statistically significant(P=0.955). There was a significant difference in the uptake rate between the body temperature control and the non-control group of P value of 0.01. Evaluation of blind images showed significant results in terms of the quality of the images. Conclusion Increased breast tissue uptake was observed when the subject was kept warm. When the body temperature was raised after injection, dilation of the peripheral blood vessels can be achieved. As a result, the blood flow became smooth and the breast uptake rate increased. In addition, an increase in breast tissue uptake will improve the quality of images.

A Study on Music Summarization (음악요약 생성에 관한 연구)

  • Kim Sung-Tak;Kim Sang-Ho;Kim Hoi-Rin;Choi Ji-Hoon;Lee Han-Kyu;Hong Jin-Woo
    • Journal of Broadcast Engineering
    • /
    • v.11 no.1 s.30
    • /
    • pp.3-14
    • /
    • 2006
  • Music summarization means a technique which automatically generates the most importantand representative a part or parts ill music content. The techniques of music summarization have been studied with two categories according to summary characteristics. The first one is that the repeated part is provided as music summary and the second provides the combined segments which consist of segments with different characteristics as music summary in music content In this paper, we propose and evaluate two kinds of music summarization techniques. The algorithm using multi-level vector quantization which provides a repeated part as music summary gives fixed-length music summary is evaluated by overlapping ration between hand-made repeated parts and automatically generated summary. As results, the overlapping ratios of conventional methods are 42.2% and 47.4%, but that of proposed method with fixed-length summary is 67.1%. Optimal length music summary is evaluated by the portion of overlapping between summary and repeated part which is different length according to music content and the result shows that automatically-generated summary expresses more effective part than fixed-length summary with optimal length. The cluster-based algorithm using 2-D similarity matrix and k-means algorithm provides the combined segments as music summary. In order to evaluate this algorithm, we use MOS test consisting of two questions(How many similar segments are in summarized music? How many segments are included in same structure?) and the results show good performance.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF