• Title/Summary/Keyword: 충전 불균형도

Search Result 54, Processing Time 0.024 seconds

Filling imbalance of elastomer TPVs in injection mold with unary branch type runner system (편측 분기형 러너시스템을 가진 사출금형에서 엘라스토머 TPV의 충전 불균형)

  • Han, Yeop-Dong;Park, Tae-Won;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.5-10
    • /
    • 2008
  • Recently, the study for filling imbalance in thermoplastic polymer has gradually been increased. However, it is hard to find the researches for filling imbalance of thermoplastic elastomer(TPE). The experiment of filling imbalance was conducted for the three kinds of thermoplastic vulcanizes(TPVs) and PP polymer in the mold with geometrically balanced runner system(Unary Branch Type Runner System). In this experiment, the effects of the melt temperature, injection pressure and injection speed on the filling imbalance were investigated. There was also the imbalance in TPV injection molding process as well as in conventional injection molding with plastics. The tendency of filling imbalance in TPV injection molding specially decreased by taking place the hesitation of TPV melt.

  • PDF

A study on the filling imbalances in hot-runner mold for internal gear based on injection molding (내측 기어 성형용 핫러너 금형에서의 충전불균형에 관한 연구)

  • No, Byung-Soo;Jea, Duck-Gun;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.1-5
    • /
    • 2008
  • Plastic parts are molded for the purpose of mass production in injection molding. Therefore designer is usually designing molds that has geometrically balanced hot runner lay-out for filling balance at cavities. Although, mold is manufactured with geometrically balanced runner lay-out, there are actually filling imbalances in cavities. These filling imbalances phenomenon are caused by complicated interaction between melt and mold. In this paper, filling imbalances for internal gear based on injection molding in hot-runner mold were investigated by CAE and injection molding experiences.

  • PDF

Using the Multi-Excitation method, the high voltage SMPS design (다중 여자 방식의 고압 SMPS 설계)

  • Sin, Min-Jeong;Kim, Chun-Sung;Hwang, Jung-Goo;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.528-529
    • /
    • 2015
  • 본 논문은 DC-DC 플라이백 컨버터 회로를 바탕으로, 고전압 입력으로부터 다채널의 절연된 저전압을 출력하는 고압 SMPS에 관한 것이다. 제안된 토폴로지는 고전압을 분배하는 커패시터와 MCU 전용의 커패시터를 직렬로 구성하고, 각 커패시터에 분배된 전압을 입력으로 다중여자 방식의 플라이백 컨버터 구조로 되어있다. 직렬 커패시터 구조는 고압환경에서의 소자들의 절연 및 전압스트레스를 저감할 수 있으며, MCU 전용의 커패시터는 시스템의 초기구동을 위한 자가충전(Self-Power) 및 Black-Start의 시스템 안정화 구조이다. 또한 다중여자방식은 변압기의 단일 코어를 사용하여 스위칭 전류를 흘려줌으로서 커패시터의 전압불균형을 막을 수 있는 장점을 가지고 있다. 제안된 토폴로지는 시뮬레이션을 통하여 타당성을 검증하였다.

  • PDF

The Effects of Runner Core Pin on the Filling Imbalance Occurred in Multi Cavity Injection Mold (다수 캐비티 사출금형에서 러너 코어핀이 충전불균형에 미치는 영향)

  • Kang C. M.;Jeong Y. D.;Han K. T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.39-42
    • /
    • 2005
  • For mass production, usually injection mold has multi-cavity which is filled through geometrical balanced runner system. Despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed. These filling imbalances are one of the most significant factors to affect quality of plastic parts when molding plastic parts in multi-cavity injection mold. Filling imbalances are results from non-symmetrical shear rate distribution within melt as it flows through the runner system. It has been possible to decrease filling imbalance by optimizing processing conditions, but it has not completely eliminated this phenomenon during injection molding processing. This paper presents a solution of these filling imbalances through using 'runner core pin'. The runner core pin which is developed in this study creates a symmetrical shear distribution within runner. As a result of using runner core pin, a remarkable improvement in reducing filling imbalance was confirmed.

  • PDF

Flow Analysis of Filling Imbalance according to Runner Shapes in Injection Mold (사출금형의 러너시스템 형상에 따른 충전불균형 유동해석 모델)

  • Jang, Min-Kyu;Go, Seung-Woo;Kim, Yeong-Min;Noh, Byeong-Su;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.5
    • /
    • pp.16-20
    • /
    • 2008
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing; However, even though geometrically balanced runner is used, filling imbalances have been observed. In these day, the CAE has been used widely in injection molding. However, CAE with fusion mesh can't indicate such as jetting, flow mark and filling imbalance in multi cavity mold. In this study, we investigated the filling imbalance according to runner shapes by CAE analysis. As a result in CAE, in case of binary branch runner system, filling imbalance was indicated between cavity to cavity, but the flow pattern of each cavity uniformed in unary branch runner system.

  • PDF

Injection Molding 3D CAE Applications for Estimating Filling Imbalance Using a New Runner system meshing (새로운 3D 멧싱 기법으로 충전 불균형을 예측할 수 있는 사출성형 CAE 활용)

  • Go, Seung-Woo;Jung, Su-Jung;Seo, Sang-hun;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.31-36
    • /
    • 2012
  • Now days CAE has been used for almost all injection molding designs in order to find the best injection conditions. Almost all CAE use 2-D mesh, but the CAE with 2-D mesh can't indicate such as jetting, flow-mark and filling imbalance in multi cavity mold. In this study, we suggested a new 3D meshing. the method which can indicate the filling imbalance in geometrically balanced runner system with Mold Flow MPI 6.1 and we found out that the calculation times are saved. As a feasibility study, we verified that Melt Flipper, RC Pin etc appeared the balanced filling behaviors. of geometrically balanced runner system and Melt Flipper, filling imbalance was indicated more accurately.

  • PDF

The Effects of the GAIM Process Variables on the Penetration-Length Variations in a Unary Branch Type Runner Mold (편측분기형 러너 금형에서 가스사출 성형변수가 성형품의 중공부 길이 변화에 미치는 영향)

  • Han Seong Ryul;Park Tae Won;Jeong Yeong Deug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.137-142
    • /
    • 2005
  • Gas-Assisted Injection Molding(GAIM) is an innovative technology for producing plastic parts and has been received extensive attention in the plastic manufacturing industries. But, due to gas-polymer interacting during the gas injection phase, the process has significantly different characteristics from conventional injection molding and, therefore, the control of the process requires much technical knowledge in processing and materials. The experiment was performed about variations of gas-penetration length that is affected by filling imbalance resulting from the structure of runner. The Taguchi method was used for the design of experiment. The most effective factors for the gas-penetration length were the shot size and mold temperature. The most effective factors for the difference of the gas-penetration length were the melt temperature and shot size. This study also discussed the filling imbalance phenomenon in a unary branch runner type mold that has geometrically balanced runner.

Injection Molding 3D CAE Applications for Estimating Filling Imbalance Using a New Runner system meshing (새로운 3D 멧싱 기법으로 충전 불균형을 예측할수 있는 사출성형 CAE 활용)

  • Go, Seung-Woo;Jung, Su-Jung;Seo, Sang-Hun;Jeong, Yeong-Deug
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.121-127
    • /
    • 2008
  • Nowdays CAE has been used for almost all injection molding designs in order to find the best injection conditions. Almost all CAE use 2-D mesh, but the CAE with 2-D mesh can't indicate such as jetting, flow-mark and filling imbalance in multi cavity mold. In this study, we suggested a new 3D meshing. the method which can indicate the filling imbalance in geometrically balanced runner system with Mold Flow MPI 6.1 and we found out that the calculation times are saved. As a feasibility study, we verified that Melt Flipper, RC Pin etc appeared the balanced filling behaviors. of geometrically balanced runner system and Melt Flipper, filling imbalance was indicated more accurately.

  • PDF

Investigation the tilling imbalance and dimensional variations of multi-cavity injection molded parts (다수 캐비티의 사출성형품에서 충전의 불균형과 치수편차의 고찰)

  • Kang, M.A.;Kim, Y.K.;Kim, J.M.;Lyu, M.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.266-270
    • /
    • 2007
  • Small injection molded articles such as lens and mobile product's parts are usually molded in multi-cavity mold. The problems occurred in multi-cavity molding are flow imbalance among the cavities. The flow imbalance affects on the dimensions and physical properties of molded articles. First of all, the origin of flow imbalance is geometrical imbalance of delivery system. However, even the geometry of delivery system is balanced well the cavity imbalance is being developed. This comes from the unsuitable operational conditions of injection molding. Among the operational conditions, injection speed is the most significant process variable affecting the filling imbalances in multi-cavity injection molding. In this study, experimental study of flow imbalance has been conducted for various injection speeds and materials. Also, the filling Imbalances were compared with CAE results. The dimensions and physical state of multi-cavity molded parts were examined. The results showed that the filling imbalances vary according to the injection speed and flow property of resins. Subsequently, the imbalanced filling and pressure distribution in the multi-cavity affect on the dimensions and physical states of molded parts.

  • PDF

A Study on the Oral Health of 12-year Old Schoolchildren in Sung-Nam City (성남시 12세 아동의 구강건강실태에 관한 조사연구)

  • Kim, Ki-Eun;Shin, Myung-Mi;Huh, Sung-Yun
    • Journal of dental hygiene science
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • This research was conducted in order to collect and arrange an oral health information needed the school oral hygiene as a part of a long term local community oral hygiene development to promote the oral health of the residents in Sung-Nam. After gathering the information of oral hygiene of 12-year old schoolchildren in Sung-Nam, these conclusions are reached: (1) The experience of dental caries in permanent teeth of 12-year old schoolchildren in Sung-Nam was revealed 74.7%, proportion of children with one or more caries in permanent teeth was 36.2%, and DMFT index was 2.75. (2) DT rate was 28.4% in total and regional difference has been revealed. In Sujung-Gu, DT rate was 36,8% and this was nearly as twice as 19.8% in Bundang-Gu. (3) For permanent teeth, fillings requirements for one surface were 26.6%, more that two surfaces were 13.3%. In addition, artificial crown treatment requirements were 1.8%, dental pulp treatment was 5.3%, and extraction requirement was 2.2%. In contrast, holders of pit and fissure sealant were only 27.1%. (4) In Sung-Nam, oral hygiene education campaign for 12-year old schoolchildren needs to be continued. Simultaneously, early stage examination and preventive approaches for decayed teeth such as pit and fissure sealant need to be considered for schoolchildren who have high tendency of dental caries and who are in areas which show high percentage of dental caries occurrence.

  • PDF