• Title/Summary/Keyword: 충적대수층

Search Result 91, Processing Time 0.028 seconds

Preliminary Study on Arsenic Speciation Changes Induced by Biodegradation of Organic Pollutants in the Soil Contaminated with Mixed Wastes (유기물분해에 따른 유류${\cdot}$중금속 복합오염토양내 비소화학종 변화의 기초연구)

  • 이상훈;천찬란;심지애
    • Economic and Environmental Geology
    • /
    • v.36 no.5
    • /
    • pp.349-356
    • /
    • 2003
  • As industrial activities are growing, pollutants found in the contaminated land are getting diverse. Some contaminated areas are subject to mixed wastes containing both organic and inorganic wastes such as hydrocarbon and heavy metals. This study concerns with the influence of the degradation of organic pollutants on the coexisting heavy metals, expecially for As. As mainly exists as two different oxidation state; As(III) and As(V) and the conversion between the two chemical forms may be induced by organic degradation in the soil contaminated by mixed wastes. We operated microcosm in an anaerobic chamber for 60 days, using sandy loam. The soils in the microcosm are artificially contaminated both by tetradecane and As, with different combination of As(III) and As(V); As(III):As(V) 1:1, As(III) only and As(V) only. Although not systematic, ratio of As(III)/As(Total) increase slightly at the later stage of experiment. Considering complicated geochemical reactions involving oxidation/reduction of organic materials, Mn/Fe oxides and As, the findings in the study seem to indicate the degradation of the organics is connected with the As speciation. That is to say, the As(V) can be reduced to As(III) either by direct or indirect influence induced by the organic degradation. Although Fe and Mn are good oxidising agent for the oxidation of As(III) to As(V), organic degradation may have suppressed reductive dissolution of the Fe and Mn oxides, causing the organic pollutants to retard the oxidation of As(III) to As(V) until the organic degradation ceases. The possible influence of organic degradation on the As speciation implies that the As in mixed wastes may be have elevated toxicity and mobility by partial conversion from As(V) to As(III).

Environmental Isotope-Aided Studies on River Water and Ground Water Interaction in the Region of Seoul Part I: Isotope Hydrology of the Shallow Alluvial Aquifer Han R. Valley (동위원소를 이용한 서울 지역의 강수와 지하수와의 상호연관성에 관한 연구 제 1 보 : 동위원소를 이용한 한강류역 충적대수층 지하수의 수문학적 연구)

  • Jong Sung Ahn;Jae Sung Kim;You Sun Kim;Peter Airey;Bryan Payne
    • Nuclear Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-96
    • /
    • 1981
  • A preliminary study of the isotope hydrology of the Han River Valley is presented. This investigation is part of a project whose overall aim is to relate the levels of heavy metal ions to the dynamics of the groundwater movement in order to establish (i) whether there is any evidence for the deterioration in groundwater quality associated with the release of industrial effluents and (ii) if so, to determine the migration path-ways. Evidence is adduced that the recharge mechanism is principally determined by the degree of urbanisation. In the metropolitan area of Seoul, river recharge dominates probably due to the combined effects of reduced infiltration and increased pumpage. In the inter-urban region, the major source of recharge is local precipitation. During the spring sampling period when the river levels were low. evidence was obtained for appreciable groundwater infiltration in the vicinity of the upstream transect. No significant correlations were observed between the levels of heavy metals in the groundwater, and the recharge mechanism, the distance from the river or the electrical conductivity of the samples.

  • PDF

Effects of the Cooling and Heating System with Seasonal Thermal Storage in Alluvial Aquifer on Greenhouse Heating (충적대수층 계간축열 냉난방 시스템의 온실 난방 효과)

  • Moon, Jong Pil;Kang, Geum Choon;Kim, Hyung Gweon;Lee, Tae Seok;Oh, Sung Sik;Jin, Byung Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.127-135
    • /
    • 2017
  • In this study, a cold well and a warm one with the distance of 100 m were installed in the alluvial aquifer. Groundwater used as the heat and the cold source of heat pump was designed to flow into the warm and the cold well with a diameter of 200 mm. In order to increase the heat and cold storage in aquifer, six auxiliary wells with the diameter of 50 mm and the depth of 30 m were installed at an interval of 5 m from the main well. Also, heat pump 50 RT, the thermal tank $40m^3$, and a remote control and monitoring system were installed in three single-span greenhouses ($2,100m^2$) for growing tomato in Buyeo, Chungcheongnam-do. According to the aquifer heat storage test which had been conducted from Aug. 31 to Sep. 22, 2016, warm water of $850m^3$ was found to flow into warm well. The temperature of the injected water was $30^{\circ}C$ (intake temperature : $15^{\circ}C$), and the heat of 12.8 Gcal was stored. The greenhouse heating test in winter had been conducted from Nov. 21, 2016 to Apr. 30, 2017. On Nov. 21, 2016 when heating greenhouse started, the aquifer temperature of the warm well was $18.5^{\circ}C$. The COP for heating with water source at $18.5^{\circ}C$ was 3.8. The intake water temperature of warm well was gradually lowered to the temperature of $15^{\circ}C$ on Jan. 2, 2017 and the heat pump COP was measured to be 3.2 at that time. As a result, the heat pump COP was improved by 18 %. and retrieval heat was 8 Gcal, the retrieval rate of heat stored in aquifer was estimated at 63 %.

Radon Concentration in Groundwater of Korea (전국 규모로 본 국내 지하수의 라돈 함량)

  • Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.661-672
    • /
    • 2018
  • Radon concentration was measured in a total of 5,453 groundwater samples from wells across Korea. The radon concentrations showed the values ranging from 0.1 Bq/L to 7,218.7 Bq/L, with a median of 48.8 Bq/L which is lower than those of other countries having similar geological conditions. The distribution of radon concentrations was lognormal. The median value is high in the granite areas (63.5-105.1 Bq/L) while it is low in the sedimentary rocks and Cheju volcanic area (16.0-20.3 Bq/L). When grouping the groundwater with well depth, the median radon value is high in weathering and/or upper bedrock zone (61.4 Bq/L) while it is low in alluvium and/or weathering zone (28.5 Bq/L). About 17.7% of the total samples exceeded 148 Bq/L of USEPA guideline value. The exceeding radon ratio more than 148 Bq/L in groundwater is highest in Jurassic granite area, however, the exceeding radon rates more than 300 Bq/L and 500 Bq/L are highest in CGRA area.

The Study of Water Availability Increments by Estuary Lake in YoungSan River (영산강하구둑에 의한 수리권 가용수량 증가에 관한 고찰 고찰)

  • Park, Hee-Seong;Choi, Hyun-Gun;Kim, Chang-Shik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2079-2083
    • /
    • 2007
  • 하구둑은 해수의 역류에 의한 염수침입을 방지하고 유역에 필요한 담수를 확보하기위하여 건설되며, 하구둑에 의하여 하천의 하구에 담수호가 생성된다. 하구담수호에 의해 기존에 염해로 취수할 수 없었던 하천구간에서의 취수가 가능하게 되며, 하구담수호를 일정한 수위로 관리함으로써 상당량의 농업용수를 확보할 수 있다. 이와 관련하여 하구담수호에 의하여 확보되는 수자원량에 대해 설계 당시의 분석 자료들이 있기는 하지만, 대부분 연 총량의 형태로 나타나 있으며, 수리권과 관련하여 하구둑에 의하여 추가적으로 확보되는 수리권 가용수량이 얼마인지에 대한 분석은 거의 없다. 그것은 하구둑의 방류량이 댐의 방류량과는 달라서 조석의 영향을 매우 크게 받기 때문에 단순한 물수지 분석으로 이를 모의하기 힘들기 때문이다. 게다가 1일 2회의 조석이 발생하므로 1일단위의 물수지 분석은 어려운 현실이다. 그럼에도 불구하고 하구둑에서 많은 양의 농업용수 취수가 이루어지고 있다. 과연 얼마정도의 양이 수리권으로서의 역할을 할 수 있는지 모르고 임의적인 허가가 계속 부여될 경우, 갈수 시 용수공급의 안정성을 확보할 수 없게 될 것이다. 따라서 안정적인 용수의 공급을 위한 적절한 수리권 가용수량에 대한 추정 필요하다. 이에 본 연구에서는 영산강하구둑의 실시간 운영을 위하여 고 등(2004)이 개발한 "영산강하구 둑 물관리 프로그램"의 기본적인 조위의 예측과 배수갑문의 방류량 산정기법 등과 수자원장기종 합계획(2006) 수립 시에 사용된 장기간의 일자연유량을 이용하여 하구둑의 수리권 가용수량 추정 모형을 개발하고, 이를 영산강 하구둑에 의해 생성된 영산호에 적용함으로써 영산호에 의해 증가되는 수리권 가용수량에 대해 고찰하여 보았다., 그리고 T-P $77.7{\sim}96.6%$(평균 94.3%)로 산정되었다. 이러한 결과는 대청호로 유입하는 유기물과 영양염류 연간 부하량의 80% 이상이 강우-유출과 함께 유입하는 것을 의미하며, 저수지 수질관리를 위해서는 유역차원의 비점오염원 관리가 시급함을 시사한다.하기 위해, 수렴흐름 추적자시험에 의한 종분산지수와 시험대수층의 평균선형유속을 이용하여 종분산계수를 구하였다. 현장에서 수행된 양수시험에 의한 평균선형유속 22.44 m/day와 평균 종분산지수 0.4155 m를 적용하여 산정된 종분산계수는 $9.32\;m^2/day$이었다. 따라서, 시험부지 내 충적층에서 일정한 양수율$(2,500\;m^3/day)$로 지하수를 개발할 시에 양수정 주변지역으로 유입되는 염소이온의 확산면적은 1일 $9.32\;m^2$ 정도일 것으로 나타났다.적인 $OH{\cdot}$ 의 생성은 ascorbate가 조직손상에 관여할 가능성을 시사하였다.었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며, 이는 한의학(韓醫學) 방제(方劑) 원리(原理)인 군신좌사(君臣佐使) 이론(理論)에서 군약(君藥)이 주증(主症)에 주(

  • PDF

A Study on Optical Design Factors by Artificial Recharge Performance (인공함양 주입성능평가에 의한 설계요소 산정 연구)

  • Won, Kyoung-Sik;Lee, Yeoung-Dong;Shin, Dong-Min;Kim, Byeong-Jun;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.603-615
    • /
    • 2020
  • The design factors of artificial recharge are determined by considering the hydrogeological characteristics of the aquifer. The optimal design factors for artificial recharge were derived after performing the injection tests step by step for each injection type (vertical well, ditch and mixed type), which were built in the test site of the study area. It was analyzed that the difference in the injection effect according to the diameter of the injection well was not large, and the 100 mm well was evaluated as appropriate in consideration of the availability and economy of land use. Since the injection effect was well maintained even in the upper rock, the depth of the injection well was proposed for the alluvial layer and the upper rock layer. On the other hand, in four cases of filter media in the ditch, it was analyzed that the penetration efficiency and the hydraulic interference effect indicated excellent injection performance when a filter medium of 10 to 30 mm diameter was filled in the ditch. In addition, the proper spacing of the injection wells was analyzed as 9~12 m considering the interference efficiency. The interference efficiency attenuation coefficient per 1 m of hole spacing was calculated to be 1.75% in this area. In the future study, the artificial recharge design factors obtained in this stage are applied and verified on site construction and operation. Also it is expected to contribute to securing water in areas where there is always a lack of water.

An Analysis of Seawater Effect on Groundwater Quality, in the Region of Sinan-gun area, Jeonam, Korea (전남 신안군 지역의 지하수 수질에 대한 해수의 영향 분석)

  • Shin, Kyungsun;Koh, Dong-Chan;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.570-580
    • /
    • 2017
  • The purpose of the study was to evaluate the groundwater quality of Sinan-gun, Jeollanam-do, an island located in the southern part of the Korean peninsula where the effect of seawater on the groundwater quality had not been investigated in the past. In order to evaluate its effect, the hydrogeological parameters including groundwater quality and major dissolved components were investigated. The water quality was measured four times in the field, and 74 of 163 samples that showed the high conductivity value of more than $500{\mu}S/cm$ and the influence of seawater on the groundwater were analyzed by $Cl^-/HCO_3{^-}$ molar ratio. The results showed that, 40 samples out of 74 were found to have a value of 2.8 or more, indicating severe and very severe effects. According to the type of groundwater quality, the ratio of samples belonging to Na-Cl type, which is considered to be influenced by the direct seawater, is 35.3% for bedrock groundwater and 52.5% for weathered zone and alluvial groundwater. In the evolution stage of groundwater due to seawater infiltration, the type of Ca-Cl prior to the Na-Cl type is 44.1% in bedrock groundwater and 45% in weathered zone and alluvial groundwater. The effect of sea water on the aquifer is likely to be influenced by distance from the shore, pumped water, and tide.

Characteristics of Waterlevel Fluctuation in Riverside Alluvium of Daesan-myeon, Changwon City (창원시 대산면 강변충적층의 지하수위 변동 특성)

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Kim, Hyoun-Su;Son, Keon-Tae;Cha, Yong-Hoon;Jang, Seong;Baek, Keon-Ha
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.457-474
    • /
    • 2003
  • This study aims to elucidate characteristics of groundwater level fluctuation at riverbank filtration sites in Daesan-myeon, Changwon City. Groundwater level fluctuation, river water level change and stream-aquifer interaction are very important to estimate optimal discharge rate of the pumping well. Water level contours from February 2003 to October 2003 show normal decreasing trend toward the Nakdong river with the hydraulic gradient of 0.008. However, flow reversion occurs when groundwater is discharged at the pumping wells or rise of the Nakdong river by rainfall. The fluctuation of the Nakdong river ranges 0 - 10 m msl. Autocorrelation analysis was conducted to the groundwater levels measured on the six monitoring wells (DS1, DS2, DS3, DS4, DS6 and DS7). The analyzed waterlevel data can be grouped into three: group 1 (DS1 and DS3) represents strong linearity and long memory effect, group 2 (DS1 and DS6) intermediate linearity and memory, and group 3 (DS4 and DS7) weak linearity and memory. Waterlevels of group 1 wells are relatively closely related to the change of river-water level. Those of group 2 wells are largely affected by the pumping and the river-water level, and those of group 3 wells are strongly linked to pumping.

Seasonal Variation of Cr(VI)-contaminated Groundwater Quality and the Potential for Natural Attenuation (6가 크롬 오염 지하수 수질의 계절변화와 자연저감 가능성)

  • Chon, Chul-Min;Ahn, Joo-Sung;Roh, Yul;Rhee, Sung-Keun;Seo, Hyun-Hee;Kim, Gue-Young;Koh, Dong-Chan;Son, Young-Chul;Kim, Ji-Wook
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.645-655
    • /
    • 2008
  • The Cr(VI) concentrations at the shallow aquifer well (MPH-0-1) of the Moonpyung groundwater monitoring station were in the range of 0.5 to 3.1 mg/L exceeding 10 to 62 times the guideline for drinking-water quality, indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other subsidiary monitoring wells except for MPH-1 and 6. Cross-correlation analyses were conducted for rainfall and groundwater level time series, resulting in the mean time of recharge after precipitation events to be 5.6 days. For rainy season, the water level was raised and the Cr(VI) concentration was several times lower than that during dry season at well MPH-0-1 well. Correlation of the Cr(VI) concentration with the groundwater-level showed that the Cr(VI) reduction was closely related with the groundwater-level rise in the well. However, the groundwater level rise during high water season induced the lateral migration of the Cr(VI)-contaminated groundwater at well MPH-4. We enriched and isolated a chromium reducing bacteria, Enterobacter aerogenes, from the Cr(VI)-contaminated groundwater in the wells MPH-0-1 and MPH-1. The bacteria may play an important role for immobilizing Cr(VI) in the Cr(VI)-contaminated groundwater. Therefore, the migration of the contaminant (Cr(VI) must has been restricted because of the natural attenuation by microbial reduction of Cr(VI) in the groundwater. This research suggests that the bioremediation of the Cr(VI)-contaminated groundwater by the indigenous bacteria may be feasible in the Cr(VI) contaminated groundwater.

A Study of Improvement for the Prediction of Groundwater Pollution in Rural Area: Application in Keumsan, Korea (농촌지역 지하수의 오염 예측 방법 개선방안 연구: 충남 금산 지역에의 적용)

  • Cheong, Beom-Keun;Chae, Gi-Tak;Koh, Dong-Chan;Ko, Kyung-Seok;Koo, Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.40-53
    • /
    • 2008
  • Groundwater pollution prediction methods have been developed to plan the sustainable groundwater usage and protection from potential pollution in many countries. DRASTIC established by US EPA is the most widely used groundwater vulnerability mapping method. However, the DRASTIC showed limitation in predicting the groundwater contamination because the DRASTIC method is designed to embrace only hydrogeologic factors. Therefore, in this study, three different methods were applied to improve a groundwater pollution prediction method: US EPA DRASTIC, Modified-DRASTIC suggested by Panagopoulos et al. (2006), and LSDG (Land use, Soil drainage, Depth to water, Geology) proposed by Rupert (1999). The Modified-DRASTIC is the modified version of the DRASTIC in terms of the rating scales and the weighting coefficients. The rating scales of each factor were calculated by the statistical comparison of nitrate concentrations in each class using the Wilcoxon rank-sum test; while the weighting coefficients were modified by the statistical correlation of each parameter to nitrate concentrations using the Spearman's rho test. The LSDG is a simple rating method using four factors such as Land use, Soil drainage, Depth to water, and Geology. Classes in each factor are compared by the Wilcoxon rank-sum test which gives a different rating to each class if the nitrate concentration in the class is significantly different. A database of nitrate concentrations in groundwaters from 149 wells was built in Keumsan area. Application of three different methods for assessing the groundwater pollution potential resulted that the prediction which was represented by a correlation (r) between each index and nitrate was improved from the EPA DRASTIC (r = 0.058) to the modified rating (r = 0.245), to the modified rating and weights (r = 0.400), and to the LSDG (r = 0.415), respectively. The LSDG seemed appropriate to predict the groundwater pollution in that it contained land use as a factor of the groundwater pollution sources and the rating of each class was defined by a real pollution nitrate concentration.