• Title/Summary/Keyword: 출구 온도

Search Result 322, Processing Time 0.026 seconds

액체로켓용 터빈시스템 설계

  • Choi, Chang-Ho;Kim, Jin-Han;Yang, Soo-Seok;Lee, Dae-Sung
    • Aerospace Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.163-172
    • /
    • 2002
  • The turbine system composed of a nozzle and a rotor is used to drive turbopumps while gas passes through the nozzle, potential energy is converted to kinematic energy, which forces the rotor blades to spin. In this study, an aerodynamic design of a turbine system is investigated using compressible fluid dynamic theories with some pre-determined design requirements (i.e.,pressure ratio, rotational speed, required power etc.) obtained from a liquid rocket engine (L.R.E.) system design. For simplicity of a turbine system, impulse-type rotor blades for open type L.R.E. have been chosen. Usually, the open-type turbine system requires low mass flow rate compared to the close-type system. In this study, a partial admission nozzle is adopted to maximize the efficiency of the close-type turbine system. A design methodology of the a turbine system has been introduced. Especially, a partial admission nozzle has been designed by means of simple empirical correlations between efficiency and configuration of the nozzle. Finally, a turbine system design for a 10 ton thrust level of L.R.E is presented.

  • PDF

Numerical Analysis and Demonstration Test on the Performance of a Static Mixer for mixing Biogas and Town Gas for the 5MW Biogas Turbine (5MW 바이오가스 터빈의 바이오가스와 도시가스 혼합용 정적 혼합기의 성능에 관한 수치해석 및 실증 연구)

  • Cha, Hyoseok;Song, Soonho;Park, Jong Yeon;Kim, Young Il;Mun, Sung Young
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2015
  • The purpose of this study is to verify the performance of a static mixer for mixing of biogas and town gas by numerical analysis and demonstration test. The reason for designing a static mixer is that there is a need to mix town gas with biogas when there is less production of biogas in biogas sites. Non-uniformity in the outlet section was calculated for investigating the performance of a static mixer. Non-uniformity was based on the mole fraction of methane in a mixture of biogas and town gas. Low non-uniformity means that biogas and town gas are mixed well through this static mixer. Also, pressure drop at the outlet section of a static mixer was calculated. The pressure drop is less than 0.2% in this static mixer. This static mixer is suitable for applying to a 5MW bio-gas turbine through the demonstration test in the field.

Comparison of the Thermal-Hydraulic Characteristics of Optimised Fuel Assembly with That of Standard Fuel Assembly (최적 핵연료집합체와 표준 핵연료집합체의 열수력학적 특성비교)

  • Paik, Hyun-Jong;Rim, Chang-Saeng;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.66-74
    • /
    • 1990
  • The thermal-hydraulic characteristics of the 17$\times$17 OFA (Optimized Fuel Assembly) used in the KNU 7&8 are analyzed and compared with that of the 17$\times$17 SFA (Standard Fuel Assembly) loaded in the KNU 5&6. The thermal-hydraulic characteristics analyzed are minimum DNBR, fuel centerline temperature and exit void fraction at normal operation and design over power transient. Additionally, local linear rod power, which will cause fuel centerline melting, is calculated. The DNBR sensitivity calculations are performed with respect to the reactor operating parameters. COBRA-IV-I code is used for these calculations. The modified W-3 correltion and the drift-flux model are applied for the critical heat flux calculation and the void fraction calculation, respectively. From the calculated results, it has been found that the possibility of DNB occurrence is higher in the OFA than in the SFA. The other hand, the local linear power resulting in fuel centerline moiling of the OFA is nearly equal to that of the SFA.

  • PDF

The Thickness of Recrystallization Layer and Mechanical Properties According to Extrusion Exit Temperature (압출 출구 온도에 따른 Al 6061 합금의 표면 재결정층 두께 변화 및 기계적 특성 변화)

  • Kim, S.B.;Park, T.H.;Kim, H.G.;Lee, S.M.;Kim, H.K.
    • Transactions of Materials Processing
    • /
    • v.30 no.5
    • /
    • pp.219-225
    • /
    • 2021
  • When extruding Al6061 alloys, deformation energy is deposited inside the extruded alloy depending on the deformation and the temperature of extrusion. This creates a Peripheral Coarse Grain (PCG) on the surface, where relatively more deformation energy. of the extruded alloy has been accumulated. Furthermore, since the deformation of materials continues while the materials recrystallize, it is important to examine the effect of deformation energy on dynamic recrystallization in the process of extruding Al alloys along with their microstructure. Prior studies explain the theory behind PCG growth though quantitative analysis on PCG growth of Al alloys during extrusion processes has not yet been addressed. This study aims to measure the generated PCG thickness which determines the correlation between extrusion outlet temperature and its effect on mechanical properties. Surface structure observations were performed using Optical Microscope (OM) and mechanical properties were evaluated through tensile strength and hardness measurement. Throughout this study, we endevoured to find the optimum condition of extrusion exit temperature of Al6061 and confirmed improved d reliability. This study describes the effect of the complex process variables such as exit temperature on the thickness of PCG layer for the Al6061 alloy using the 200 tons extrusion press. We therefore, discovered that the PCG layer thickness was 117 ㎛ at temperatures between 460 ℃ to 520 ℃.

Characteristics of Flow Field and IR of Double Serpentine Nozzle Plume for Varying Cross Sectional Areas and Flight Conditions in UCAV (Double Serpentine 노즐의 단면적과 비행조건 변화에 따른 UCAV의 플룸 유동장 및 IR 특성 연구)

  • Lee, Yu-Ryeol;Lee, Ji-Won;Shin, Chang-Min;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.8
    • /
    • pp.689-698
    • /
    • 2021
  • The development of modern warfare detection technology is increasingly threatening the survivability of aircraft. Among them, IR-seeking missiles greatly affect the survivability of aircraft and are a main factor that reduces the success rate of aircraft missions. In order to increase aircraft survivability, studies on shape-modifying nozzles with added curvature are being actively conducted. In this study, we selected a double serpentine nozzle among shape-modifying nozzles to increase aircraft survivability. We then investigated the effects of the location of the maximum area change rate of the nozzle. It was confirmed that the location of the change rate of area affects the thrust and exit temperature of the nozzle. In addition, it was shown that the thrust penalty was reduced as the position of the change rate of the maximum area was located at the rear of the nozzle.

Off-design Performance Analysis based on Experimental Data of a Micro Gas Turbine Engine (실험데이터 기반 마이크로 가스터빈엔진 탈 설계점 성능해석)

  • Kim, Seungjae;Choi, Seongman;Rhee, Dongho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.64-71
    • /
    • 2018
  • It is essential to understand the characteristics of gas turbine components in order to carry out an off-design analysis of a gas turbine engine. In this study, a micro gas turbine engine test system was constructed to understand the performance characteristics of gas turbines. The temperature and pressure in the flow path of the micro gas turbine was collected by measuring the engine spool speed, and a compressor map was constructed by using the experimental data. The exhaust gas was collected at the turbine outlet and the combustion efficiency was calculated. An off-design performance analysis at ground static was performed using GasTurb software by applying the compressor map and combustion efficiency obtained from the experimental data. Futhermore, we compared and evaluated the analysis results with engine operating data.

Design of the Condenser and Automation of a Solar Powered Water Pump (태양열 물펌프의 운전 자동화 설계)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;Lee Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.141-154
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which the electrical power is not available. The average so]ar radiation energy is 3.488 kWh/($m^2{\cdot}day$) in Korea. In this study, the automatic control logic and system of the water pump driven by the radiation energy were studied, designed, assembled, tested and analyzed for realizing the solar powered water pump. The experimental system was operated automatically and the cycle was continued. The average quantity of the water pumped per cycle was about 5,320 cc. The cycle time was about 4.9 minutes. The thermal efficiency of the system was about $0.030\%$. The pressure level of the n-pentane vapour in flash tank was 150$\%$450 hPa(gauge) which was set by the computer program for the control of the vapour supply. The pressure in the condenser and air tank during cycles was maintained as about 600 hPa and 1,200 hPa respectively. The water could be pumped by the amount of 128kg/($m^2{\cdot}day$) with the efficiency of $0.1\%$ and the pumping head of 10 m for the average solar energy in Korea.

  • PDF

Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture (시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kang, Geum-Chun;Kim, Young-Joong;Paek, Yee
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • It has become a big matter of concerns that the skill and measures against reduction of energy and cost for heating a protected horticultural greenhouse were prepared. But in these days necessity of cooling a protected horticultural greenhouse is on the rise from partial high value added farm products. In this study, therefore, a horizontal type geothermal heat pump system with 10 RT scale to heat and cool a protected horticultural greenhouse and be considered to be cheaper than a vertical type geothermal heat pump system was installed in greenhouse with area of $240\;m^2$. And cooling performances of this system were analysed. As condenser outlet temperature of heat transfer medium fluid rose from $40^{\circ}C$ to $58^{\circ}C$, power consumption of the heat pump was an upturn from 11.5 kW to 15 kW and high pressure rose from 1,617 kPa to 2,450 kPa. Cooling COP had the trend that the higher the ground temperature at 1.75 m went, the lower the COP went. The COP was 2.7 at ground temperature at 1.75 m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$ and the heat extraction rate from the greenhouse were 28.8 kW, 26.5 kW respectively at the same ground temperature range. 8 hours after the heat pump was operated, the temperature of ground at 60 cm and 150 cm depth buried a geothermal heat exchanger rose $14.3^{\circ}C$, $15.3^{\circ}C$ respectively, but the temperature of ground at the same depth not buried rose $2.4^{\circ}C$, $4.3^{\circ}C$ respectively. The temperature of heat transfer medium fluid fell $7.5^{\circ}C$ after the fluid passed through geothermal heat exchanger and the fluid rejected average 46 kW to the 1.5 m depth ground. It analyzed the geothermal heat exchanger rejected average 36.8 W/m of the geothermal heat exchanger. Fan coil units in the greenhouse extracted average 28.2 kW from the greenhouse air and the temperature of heat transfer medium fluid rose $4.2^{\circ}C$after the fluid passing through fan coil units. It was analyzed the accumulation energy of thermal storage thank was 321 MJ in 3 hours and the rejection energy of the tank was 313 MJ in 4 hours.

Improvement of Energy Efficiency of Plants Factory by Arranging Air Circulation Fan and Air Flow Control Based on CFD (CFD 기반의 순환 팬 배치 및 유속조절에 의한 식물공장의 에너지 효율 향상)

  • Moon, Seung-Mi;Kwon, Sook-Youn;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2015
  • As information technology fusion is accelerated, the researches to improve the quality and productivity of crops inside a plant factory actively progress. Advanced growth environment management technology that can provide thermal environment and air flow suited to the growth of crops and considering the characteristics inside a facility is necessary to maximize productivity inside a plant factory. Currently running plant factories are designed to rely on experience or personal judgment; hence, design and operation technology specific to plant factories are not established, inherently producing problems such as uneven crop production due to the deviation of temperature and air flow and additional increases in energy consumption after prolonged cultivation. The optimization process has to be set up in advance for the arrangement of air flow devices and operation technology using computational fluid dynamics (CFD) during the design stage of a facility for plant factories to resolve the problems. In this study, the optimum arrangement and air flow of air circulation fans were investigated to save energy while minimizing temperature deviation at each point inside a plant factory using CFD. The condition for simulation was categorized into a total of 12 types according to installation location, quantity, and air flow changes in air circulation fans. Also, the variables of boundary conditions for simulation were set in the same level. The analysis results for each case showed that an average temperature of 296.33K matching with a set temperature and average air flow velocity of 0.51m/s suiting plant growth were well-maintained under Case 4 condition wherein two sets of air circulation fans were installed at the upper part of plant cultivation beds. Further, control of air circulation fan set under Case D yielded the most excellent results from Case D-3 conditions wherein air velocity at the outlet was adjusted to 2.9m/s.

램제트 엔진에서의 화염 전파와 비정상 연소 현상에 관한 수치해석

  • ;Vigor Yang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.10-10
    • /
    • 2000
  • 램제트 엔진은 비추력이 높고 추력 레벨은 낮으므로, 2단 추진기관에 적합한 추진 시스템이다. 1단-추진기관의 작동이 끝나고, 2단 램제트 엔진이 점화 후 안정된 연소에 도달되기까지 비행체의 속도는 항력에 의하여, 초당 약 마하수 0.1 정도씩 감소된다. 1단 연소 후 2단 램제트로 전환되는 지연시간이 길수록 1단에서 요구되는 종말 가속도는 증가되므로, 1단이 차지하게되는 부피는 증가되고 비행체의 크기 또한 늘어나게 된다. 따라서 1단에서 2단 램제트로 천이되는데 소요되는 시간을 가능한 짧게 하는 것이 효과적이다. 그러나 램제트 엔진의 특성상 선결되어야할 다음과 같은 여러 문제들이 있다. 첫째, 1단 작동 시 공기 흡입구와 연소실은 차단벽으로 분리되어 있다가, 1단 연소후 차단막이 제거되어 외부공기가 램제트 연소실로 흡입된다. 흡입되는 공기는 흡입구의 형상에 의하여 램 압축되지만 초음속으로 연소실을 통과하게된다. 연료 주입 구에서 공급되는 연료는 연소실에서 유동의 흐름방향(streamline)에 따라서 연소실로 확산되는데, 연소되기 전에는 유속이 빠르게 노즐로 빠져 나가므로 램제트 연료가 재순환 구역(recirculation zone)으로 침투하는데 쉽지가 않다. 둘째, 연소실 입구에서 발생되는 와류 (ring vortex)는 1단 연료의 고온 연소 가스를 연소실로 확산시키는데, 비 균일한 온도 분포를 유발하여 램제트 연료의 점화에너지가 공급되는 시간이 적당하지 않을 경우 균일한 화염 전파에 악영향을 준다. 셋째, 연소실에서의 빠른 유동 조건은 연료가 연소실에 머무를 수 있는 시간을 감소시키며, 연소실 입구에서 강한 전단 응력이 발생되어 화염이 안정화되는데 악 영향을 미치게된다. 본 논문은 공기 흡입구, 연소실 및 노즐을 통합하여 수치해석을 하였으며 열유동/점화/연소등의 미케니즘을 이해하고, 주요 인자들 중 와류의 영향에 초점을 맞추었다.다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14) 식도경 시행회수는 1회가 17례(54.8%), 2회가 9례(29.0%), 3회 이상이 5례(16.1%)였다.EX>$IC_{50}$/ 값이 210 $\mu\textrm{g}$/$m\ell$로서 효과적

  • PDF