• Title/Summary/Keyword: 축압축 실험

Search Result 193, Processing Time 0.022 seconds

Confinement Effect by Plate Type Lateral Reinforcement and Investigation of the Possibility for Use of High Strength Steel Bars in Reinforced Concrete Columns (횡방향 판재에 의한 횡구속 효과 및 철근콘크리트 기둥에서 고강도 철근의 사용성 검토)

  • Cho, Young-Jae;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.643-650
    • /
    • 2012
  • The limitation of the yield strength in reinforced concrete columns is given for the effective use of high-strength steel bar, because very high-strength steel bar does not yield while concrete fails in compression. In order to overcome this limitation, it is required to increase peak strain of the concrete. The objective of this study is to examine the confinement effect of plate type lateral reinforcement in reinforced concrete columns. From this experimental study, the reinforced concrete columns confined by plate type carbon fiber sheets showed higher compressive strength and peak concrete strain comparing to the unconfined columns. The confinement effect is higher when cross-sectional type is a circular one than a square one. Moreover, the confinement effect was also higher for circular type confinement. Based on this study, high-strength steel bars with strength exceeding 800 MPa can be effectively used for reinforced concrete columns confined by plate type lateral reinforcements.

A Study on Properties of Mechanical Behaviors of Concrete Confined by Circular Steel Tube (원형강관으로 구속된 콘크리트의 역학적 거동 특성에 관한 연구)

  • 박정민;김화중
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.199-210
    • /
    • 1995
  • We could say that the concrete filled steel tube structure is superior in the vlew of various structure properties as to promote improvement of structural capacity to dtmonstrate heterogeneous material properties interdependently. The compressive strength is increased by putting to tri axial stress because lateral expansion of concrete 1s confined by the steel tube, when concrete conflned by steel tube fall under centric axial load. Also, it have an advantage that decreasr of load carrying capacity 1s small, not occuring section deficiency due to protect falling piienornonon by co~nprrssion fallurc of concrete. So this study investigated for structural behaviors yroprrtiex of concwir. confined by steel tube throughout a series of experlmerit with kcy parxncter, such as diameter-to-thickness(D / t) ratio, strength of concrete as a study on properties of structural behaviors of confined concrete confined by circular steel tube( tri axial stress). Frorn the expcrment results, the obtained results, are surnrnarised as foliow. (1) The restraint effect of concrete by steel tube was presented significantly as the D /t ratio of steel tube and the strength of filled concrete decrease, and the confined concrete by circular steel tube was increased respectively twice as much as 4-7 in deformation capacity at the ultimate strength ,compared with those of non-confined concrete, so expected to increase flexible effect of concrete. (2) The emprical formula to predict the ultimate capacity of confined concrete by steel tube and concrete filled steel tube column using restraint coefficient of concrete were proposed.

Structural Performance of High-Strength Concrete-Filled Steel Tube Steel Columns using Different Strength Steels (이종강종을 사용한 고강도 CFT 합성부재의 구조성능)

  • Choi, In Rak;Chung, Kyung Soo;Kim, Jin Ho;Hong, Geon Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.711-723
    • /
    • 2012
  • Structural tests were performed to investigate the structural performance of concrete-filled steel tube column using different strength steels in their flange and web with high-strength steel HSA800 and mild steel SM490, respectively. The test parameters included the strength of column flange and infill concrete, and effect of concrete infill. Connection between different grade steels were welded using the electrode appropriate for mild steel and verified its performance. To evaluate the behavior of test specimens, eccentric loading tests were performed and the results were compared with the prediction by current design codes. Axial load and moment carrying capacity of test specimens increased with the yield strength of compression flange and weld fracture occurred after the specimen shows full strength. The prediction result for axial load-bending moment relationship and effective flexural stiffness gave good agreement with the test result.

On Prediction of Ground Heave and the Performance of the Isolation-tube Shafts (지반 괭창량 예측과 분리형 현장 타설 말뚝의 거동)

  • 김명학
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.111-128
    • /
    • 1998
  • An experimental study, which included four 305mm-diameter test shafts, one reference shaft with standard design and three test shafts with isolation tubes, is described. The soil was also soil heave and shrinkage that occur during suction changes at the field site. The test shafts were monitored for a period of about 18 months. Maximum ground movements exceeding 35mm were observed. Movements of only 1 to 2mm were observed in the test shafts with isolation tubes, while movements of 4 to 5mm were observed in the reference shaft. A simple computing model was developed to predict, based on suction changes, the maximum amount of ground heave. Relationship among suction. total stress, and volumetric strain was abtained in the laborstory. This relationship, used as inputs to the predictive model, enabled the computation of the maximum ground heave.

  • PDF

Numerical Study of High-strength Steel CHS X-joints Including Effects of Chord Stresses (주관응력효과를 고려한 고강도강 X형 원형강관접합부의 수치해석 연구)

  • Kim, Seon Hu;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.2
    • /
    • pp.115-126
    • /
    • 2018
  • Internationally representative steel design standards have forbidden or limited the application of high-strength steels to tubular joints, partly because of concerns about their unique material characteristics such as high yield ratio. Most of design standards stipulate that for steels whose yield strengths exceed 355 or 360 MPa, the strength equations cannot be utilized or strength reduction factor below 1.0 should be multiplied. However, the mechanical background behind these limitations is not clear. Experimental testing of high-strength steel CHS (circular hollow section) X-joints recently conducted by the authors also clearly indicated that the current limitations might be unduly conservative. As a continuing work, extensive, test-validated numerical analyses were made to investigate the behavior of high-strength steel CHS X-joint under axial compression. Three steel grades covering ordinary to very high strength steels were considered in the analysis. Again it was found that the high strength penalty to the joint strength in current standards is too severe and needs to be relaxed. The high-strength steel joints under the effects of chord stress generally showed higher strength than the ordinary steel joints and their strengths were conservatively predicted by current standards. It is also emphasized that current format of the CHS X-joint strength equation does not reflect observed behavior and needs to be recast.

Evaluation for Mechanical Properties of High Strength Concrete at High Temperature by Stressed Test and Unstressed Test (설계하중 사전재하 및 비재하방식에 의한 고강도콘크리트의 고온특성 평가)

  • Kim, Gyu-Yong;Kim, Young-Sun;Lee, Tae-Gyu;Park, Chan-Kyu;Lee, Seung-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.583-592
    • /
    • 2008
  • Recently, the effects of high temperature on compressive strength, elastic modulus and strain at peak stress of high strength concrete were experimentally investigated. The present study is aimed to study the effect of elevated temperatures ranging from 20 to 700 on the material mechanical properties of high strength concrete of 40, 60, 80 MPa grade. In this study, the types of test were the stressed test and stressed residual test that the specimens are subjected to a 25% of ultimate compressive strength at room temperature and sustained during heating and when target temperature is reached, the specimens are loaded to failure. And another specimens are loaded to failure after 24 hour cooling time. Tests were conducted at various temperatures ($20{\sim}700^{\circ}C$) for concretes made with W/B ratios 46%, 32% and 25%. Test results showed that the relative values of compressive strength and elastic modulus decreased with increasing compressive strength grade of specimen and the axial strain at peak stress were influenced by the load before heating. Thermal strain of concrete at high temperature was affected by the preload level as well as the compressive strength. Finally, model equation for compressive strength and elastic modulus of heated high strength concrete proposed by result of this study.

Radionuclide Diffusion in Compacted Domestic Bentonite (압축 국산 벤토나이트 내에서 방사성 핵종의 확산이동)

  • Choi, Jong-Won;Lee, Byung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.27-39
    • /
    • 1991
  • The diffusion of Sr-85, Cs-137, Co-60 and Am-241 in compacted domestic bentonite was studied, using a diffusion cell unit in which diffusion took place axially from the center of cylindrical bentonite sample body. The effects of compaction density and heat-treated bentonite on diffusion were analysed. And the diffusion mechanism of radionuclide was also analysed by evaluating the measured diffusivity of anion Cl-36. The apparent diffusivities obtained for Sr-85, Cs-137, Co-60 and Am-241 were $l.07{\times}10^{-11},\;6.705{\times}10^{-13},\;l.226{\times}10^{-13}\;and\; l.310{\times}10^{-14}m^2/sec$, respectively. When the as-pressed density of bentonite increased from $1.8\;to\;2.0g/cm^3$, the apparent diffusivity of Cs-137 decreased by quarter. In the case of bentonite heat-treated to $150^{\circ}C$, no significant change in diffusivity was observed, which showed the possibility that the domestic bentonite could be used as a chemical barrier to retard the radionuclide migration at below $150^{\circ}C$. From the calculated pore and surface diffusivity, the surface diffusion due to the concentration gradient of radionuclide sorbed on the solid phase was found to dominate greatly in total transport process.

  • PDF

Experimental Evaluation of Fire Behavior of High-Strength CFT Column with Constant Axial Load (일정축력하에 고온을 받는 고강도 콘크리트 충전강관 기둥의 구조적 거동에 관한 연구)

  • Chung, Kyung Soo;Choi, In Rak;Kim, Do Hwan;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.71-80
    • /
    • 2013
  • Fire-resistant (FR) test data for a square concrete-filled steel tube (CFT) columns consisting of high-strength steel (fy>650MPa) and high strength concrete (fck>100MPa) under axial loads are insufficient. The FR behavior of square high-strength CFT members was investigated experimentally for two specimens having ${\Box}-400{\times}400{\times}15{\times}3,000mm$ with two axial load cases (5,000kN and 2,500kN). The results show that the FR performance of the high-strength CFT was rapidly decreased at earlier time (much earlier at high axial load) than expected due to high strength concrete spalling and cracks. In addition, a fiber element analysis (FEA) model was proposed and used to simulate the fiber behaviour of the columns. For steel and concrete, the mechanical and thermal properties recommended in EN 1994-1-2 are adopted. Test results were compared to those of numerical analyses considering a combination of temperature and axial compression. The numerical model can reasonably predict the time-axial deformation relationship.

A Study on the Structural Behavior of Eccentrically Loaded Steel Column Base Plates (편심 축하중을 받는 강구조 주각부의 거동에 관한 연구)

  • Lee, Seung Joon;Song, Hyun Seok
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.323-332
    • /
    • 2008
  • The behavior of eccentrically loaded steel column base plates is investigated experimentally and analytically. A total of 8 test specimens are fabricated and tested. The effects of eccentricity and thickness of baseplate on the behavior of base plates are investigated. Analytical study is performed using the Finite Element Analysis Program ANSYS 8.1 to investigate distribution of bearing pressure. The results from to the distribution of bending strain of the base plate. However, the distribution of the bearing pressure obtained from the analysis is different from that assumed in the current design method. The results from the analysis show that the bearing pressures of the baseplate are concentrated under the compressively stressed column flange, as the eccentricity is increased. Also the results from the analysis are different from the results of design using the existing design method and the design method according to the AISC-Steel Design Guide.

Strength of Reinforced Concrete Beam-Column Assembles Subjected to Seismic Loading (지진하중을 받는 철근콘크리트 접합부의 강도)

  • Lee, Jung-Yoon;Chai, Hyee-Dai
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.25-33
    • /
    • 2006
  • This paper provides a method to predict the ductile capacity of reinforced concrete beam-column joints that fail in shear after the plastic hinges occur at both ends of the adjacent beams. After the plastic hinges occur at both ends of the beams, the longitudinal axial strain at the center of the beam section in the plastic hinge region abruptly increases because the neutral axis continues to move upward toward the extreme compressive fiber and the residual strain of the longitudinal bars continues to increase with each cycle of inelastic loading. An increase in the axial strain of the beam section after flexural yielding widens the cracks in the beam-column joints, thus leading to an decrease of the shear strength of the beam-column joints. The proposed method takes into account shear strength deterioration in the beam-column joints. In order to verify the shear strength and the corresponding ductility of the proposed method, test results of 52 RC beam-column assembles were compared. Comparisons between the observed and calculated shear strengths and their corresponding ductilities of the tested assembles, showed reasonable agreement.