• Title/Summary/Keyword: 축소모델 실험

Search Result 351, Processing Time 0.023 seconds

Experimental Study on the Similitude of Small-Scale Models in Cyclic Lateral Behaviors of RC Shear Wall Subassemblages (RC벽식 부분구조의 반복 횡하중 거동에서의 축소모델 상사성 실험연구)

  • Lee, Han-Seon;Cho, Chang-Seok;Lee, Sang-Ho;Oh, Sang-Hoon;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.805-816
    • /
    • 2010
  • For earthquake simulation test it is essential to make sure the similitude in behaviors between the full scale prototype and the reduced scale model. This paper presents the test results obtained through the cyclic lateral-force test, on two-story RC wall subassemblages. A lower 2-story portion of the prototype structure was selected as subassemblages. The global behavior such as the strength and ductility, and the local behavior such as flexural, shear and uplift deformation were measured. The test results of the 3 : 5 scale specimens representing the prototype were compared with those of 1 : 7 scale models. Two types of subassemblages were used: One with lintel beams and one without lintel beams. The comparison shows that 1 : 7 scale model simulated in general successfully the global and local behaviors of the prototype.

A Study on the Similitude of member Behavior for Small-Scale Modeling of Reinforced Concrete Structure (철근콘크리트 축소모델의 부재거동 상사성에 관한 연구)

  • 이한선;장진혁
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.3
    • /
    • pp.177-185
    • /
    • 1996
  • Four types of experiments were performed to check the similitude of member behavior between prototype and 1 /10 scale models : (1) Test of slender columns with P-$\Delta$ effect, (2) Test of short columns with and without confinement steel, (3) Test of simple beams without stirrups, and (4) 'T-beam test. Based on the results of experiments, the conclusions were made as follows : (1) The P-$\Delta$ effect of slender columns can be almost exactly represented by 1/10 scale model. (2) The effect of confinement on short columns by the hoop steel can be also roughly simulated by 1/10 scale model. (3) The failure modes of simple beams without stirrups are brittle shear failures in prototype whereas those of 1/10 scale models are the ductile yielding of tension steel followed by large diagonal tension cracking and compressive concrete failure. (4) The behaviors of prototype and 1/10 scale model in T-beams appear very similar.

Small-scaled Experiment of Ship Power System with Real-time Simulator (실시간 시뮬레이터를 이용한 선박 전력 시스템의 축소 모델 실험)

  • Ko, Sanggi;Kim, So-Yeon;Choe, Sehwa;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.204-205
    • /
    • 2013
  • 선박 전력 시스템 설계에 관한 연구의 경우 실제 선박에서의 실험의 어려움 때문에 디지털 시뮬레이션에 의존해 연구를 진행해 왔다. 본 논문에서는 선박 전력 시스템의 보다 정밀한 실험 및 제어 알고리즘 검증을 위해 축소 모델과 실시간 시뮬레이터를 동시에 이용하는 새로운 실험 방법을 제안하였다. 실제 크기의 선박 전력 시스템은 직접 제작하기 어렵기 때문에 축소 모델을 이용하였고 복잡한 선박 전력 시스템의 일부를 실시간 시뮬레이터로 모의함으로써 실제 실험 세트의 구성을 간소화 할 수 있었다. 축소 모델 실험을 통해 선박 전력 시스템의 과도 상태 및 정상 상태 해석을 수행하였으며 이러한 시스템에서 얻은 결과는 추후 실선 제작을 위한 설계 자료로 활용될 수 있다.

  • PDF

A Study on Manufacturing and Experimental Techniques for the 1/5th Scale Model of Precast Concrete Large Panel Structure (프리캐스트 콘크리트 대형판 구조물의 1/5축소모델 제작 및 실험기법 연구)

  • 이한선;김상규
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.2
    • /
    • pp.139-150
    • /
    • 1996
  • The objective of this study is to provide the information on the manufacturing and exper- , ructures. imental techniques of small scale modeling of precast concrete(P.C.) large panel :-t The ad~~pted scale was one-fifth. 4 types of experiments were performed : nlaterial tests for model concrete and model reinforcement, compressive test of horizontal joint, shear test of vertical joint and cyclic static test of 2-story subassemblage structure. Based on the experimental results, the following conclusions are drawn : i 1) Model concrete had in general larger compressive strength than expected. (2) Model reinforcement showed less ductility if the annealing processes were performed without using vaccuum tube. 131 Failure niotles of horizontal and vertical joints were almost same for both prototype and model. But the strength of model appears to be higher than required by similitude law. (41 Hysteretic behavior of 1 /T, scale subassemblage model can be made quite similar to that of prototype if the ductility of model reinforcement and compressive strength of model concrete could be representative of those of prototype.

Reversed Cyclic Latcral Load Test of A 2-Bay 2-Story Reinforced Concrete Frame With Seismic Detail (내진상세를 가진 2경간 2층 철근콘크리트 골조의 반복횡하중 실험)

  • Lee, Han-Seon;Woo, Sung-Woo
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.183-193
    • /
    • 1996
  • The objective of this study is to investigate the characteristics of elastic and inelastic bekavior of ductile momenting-resisting reinforced concrete frame subjected to reversed lateral loading such as earthquake excitations. For this purpose, a 2-bay 2-story reinforced concrete plane frame with seismic detail was designed and one 1/2.5-scale subassemblage was manufactured according to the required similitude law. Then, the reversed load test under the displacement control was performed statically to this subassemblage. Finally, the results of this test were analysed regarding to (1) the design load vs actual strength, (2) degradation in stiffness and strength. (3) failure mode or energy dissipation. (4) local deformations.

A Study on the Performance Assessment of BARCOM Model (BARCOM 모델의 성능평가에 관한 연구)

  • Lee, Hong-Pyo;Jang, Jung-Bum;Hwang, Kyeong-Min;Song, Young-Chul
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.388-391
    • /
    • 2011
  • 이 논문에서는 인도의 BARC에서 가압중수형 격납건물의 선형탄성 거동 및 균열의 발생형상과 극한내압 평가를 위해서 건설한 1/4 축소모델 격납건물에 대하여 실험한 결과와 유한요소 해석에 의한 결과를 비교 분석하였다. 유한요소 해석은 상용프로그램인 ABAQUS를 이용하였고 각각의 구조재료에 대한 수치 해석모델을 작성하여 내압해석을 수행하였다.

  • PDF

Stability Analysis of the Inclined Pillars by Scaled Model Test (축소모형실험을 통한 편간 불일치 필라의 안정성 연구)

  • Kim, Jong-Gwan;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.26 no.6
    • /
    • pp.508-515
    • /
    • 2016
  • In this study, we compared the stability of the pillars by using room and pillar mining method with the four models with different stiffness and pillar overlap ratio. The experimental models consist of two plaster models (overlap ratio 0%, 100%) and two cement models(overlap ratio 0%, 100%). The soft and hard rocks are modeled by plaster and cement models respectively. In these experiments, the model materials with strength values reflecting the calculated scaled factors not been used, so it is not a true scaled model test that reproduces in situ state in the laboratory. Experimental results show that the different overlap ratio pillars are one of the factors that can affect the stability of the mine.

Shaking Table Tests of a 1/4-Scaled Steel Frame with Base Isolators (1/4축소 철골구조물을 이용한 건물 기초분리장치의 진동대실험)

  • 송영훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.39-48
    • /
    • 1997
  • New form of base isolators made of steel spring coated with both natural and artficial rubber were manufactured and tested for material properties. Shaking table experiments were performed using a model structure attached with the bearings. The model structure used in the test is a 1/4 scaled steel structure, and earthquake records were used to check the lateral and vertical stability and effectiveness of the isolators. According to the results all three types of isolators turned out to be effective in reducing the acceleration induced by the earthquake vibration.

  • PDF

Aerodynamic Performance Test and Evaluation by Using the Subscale HAWT Blade Model (축소모델 공력실험에 의한 수평축 풍력발전 시스템용 블레이드의 공력성능 평가에 관한 연구)

  • 공창덕;방조혁;김하봉;김종식
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.39-39
    • /
    • 1998
  • 본 연구는 500KW급 수평축 풍력발전기용으로 개발된 회전날개의 시제품 제작에 앞서 축소모델에 대한, 이론적으로 예측된 공력성능과 신축에 의한 공력성능을 비교 검토함으로서, 설계결과를 검증하고, 필요한 경우 설계를 보완하여 개발위험도를 최소화하기 위해 수행되었다. 시험모델의 크기는 실제의 5%로서 직경이 2.1m이며 날개의 시위길이는 0.2r/R에서 0.101m, 날개끝에서 0.043m 이고, 날개단면형 상온 FX-S-03-182이다. 블레이드의 재질은 Glass/Epoxy 복합재료로 제작되었으며, 실제 풍황을 모사하기 위해 자연풍 상태에서 실험하였다. 실험장치의 구성은 15m 높이의 타워에 회전날개와 전자브레이크 및 각종 센서를 장착하였고, 날개가 회전하기 시작하면 제동장치에 의해 부하를 주면서 토크, 회전수, 풍속 등을 각각의 센서로부터 자료획득장치를 통해 자료처리를 할 수 있도록 하였다. 실험하는 동안 풍속은 4m/s-13m/s 정도로서 시동 풍속인 4m/s와 정격풍속인 12m/s를 포함하여 회전날개의 전체적인 특성을 파악하기 용이하였고, 이론적인 예측성능과 측정된 성능을 비교 검토한 결과 비슷한 결과를 얻어 공력설계 및 해석 방법을 검증하였다.

  • PDF

An Experimental Study on Smoke Spread Using a Reduced-scale Subway Building Model (지하역사 축소모델을 이용한 연기확산에 대한 실험적 연구)

  • Kim, Myung-Bae;Choi, Byung-Il
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.49-56
    • /
    • 2008
  • Smoke propagation for the Daegu Metro fire is reproduced by a reduced-scale model experiment. The three-story station building was modeled with 1/20-scale, and the tunnel connected to the platform was not completely modeled because of its length. To include the flow resistance the tunnel provides the mesh screens were used in the model. The fire scenario was selected based on the fire growth rate of the metro car seat where the fire initiated. The time when smoke arrived at each compartment in the station building was measured by thermocouples and visualization. Regarding fire ventilation, the air supply that has been accepted as conventional design in a subway metro building intensifies smoke spread. The results show that the whole building was filled with smoke in about 10 minutes in case of no ventilation.