• Title/Summary/Keyword: 축교정

Search Result 98, Processing Time 0.031 seconds

A Study on the Detection of Axis-Rotation in Contact Lenses (콘택트렌즈 회전량 검출에 대한 연구)

  • Lee, Dong-Hee;Kim, Jung-Hee;Cha, Jung-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.255-259
    • /
    • 2005
  • When we wear contact lenses for correcting astigmatism, we often experience the axis-rotation of contact lenses that is happened in case we could not fit the axis of lens exactly or by the eyelid used to blink. In this case, because the exact correcting state becomes in the wrongly correcting state, the asthenopia is led, and the decline of eyesight can be led. For this reason, we need to know axis-rotating degrees of contact lenses. If a contact lens rotated, a residual astigmatism may be detected in the refraction examination after wearing. Using this, we developed a program that calculates the axis-rotating amount of contact lenses.

  • PDF

A Radiological Study on the Morphology of Labial Alveolar Bone in the Mandibular Incisor Area of Mandibular Prognathism Patients (하악전돌증 환자의 하악전치부 순측 치조골 형태에 관한 방사선학적 연구)

  • Kim, Jeom-Sook;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.209-217
    • /
    • 1999
  • This study was concerned with comparing the measured values of labial alveolar bone through the lateral cephalometric radiography and mandibular incisor cross-sectional tomogram between two groups, one group of mandibular prognathism patients who needed an orthognathic surgery as an experimental group and the other group who had normal molar relationships as a control group. The purpose of the study was to find out the predisposing factor of bone resorption and gingival recession before orthodontic treatment. The results were as follows: 1. The cross-sectional area of labial alveolar bony plate in mandibular prognathism was significantly smaller than that of control group. 2. In mandibular prognathism, the distance between cementoenamel junction and alveolar crest was significantly greater than control group. 3. There were negative correlations between area of labial alveolar bony plate and distance from cementoenamel junction to alveolar crest, and positive correlations between area of labial alveolar bony plate and distance from alveolar crest to root apex. 4. In mandibular prognathism, there were positive correlations between IMPA and thickness of symphysis, and negative correlations between IMPA and the alveolar bony height. The results of the present study suggest the mandibular prognathism patients are prone to the gingival recession due to the small amount of labial alveolar bone around lower incisors.

  • PDF

Adaptive Three-Point Bending Controller Through Real-Time Springback Estimation for Beams (실시간 스프링백 예측을 통한 보의 3점굽힘 적응제어기 설계)

  • 정성종
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.62-68
    • /
    • 2000
  • In order to automate straightening process of deflected beams an adaptive three-point bending controller is studies which estimates and controls springback of beams under three-point bending. An analytical load-deflection model for three-point bending of beams with circular cross sections is derived nondimensionally. In spite of variation of material and process parameters this model can be applied to springback estimation by measuring real-time values of reactive load and deflection of the beam. A hydraulic punch stroke controller is designed to take real-time controls of the permanent deflection of the beam. The validity of the proposed system is verified through experiments.

  • PDF

Development of Shaft Straightening Machine with Springback Observer (스프링백 관측기를 이용한 축교정기 개발)

  • 안중용
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.3
    • /
    • pp.22-30
    • /
    • 1996
  • In order to compensate for out-of-straightness of shafts, an automatic straightening process composed of an automatic measuring module, an automatic control unit and operating softwares was developed with a hydraulic press. The out-of-sraightness of each shaft was measured automatically in the measuring stage. An optimal pressure point was determined to minimize TIR value of the shaft according to press count of 3-points bending process. In the geometric adaptive control procedure, punch stroke and springback of the shaft were predicted by an observer using on-line measured values of press force and deflection amount I each press count. An automatic straightening machine was realized with the measuring module, the GAC module, PLD, IBM-PC and the operating software on the hydraulic press. the validity of the proposed straightening process was confirmed through a series of experiments with cam shafts.

  • PDF

Mathematical Expression of the Toric Cornea using Corneal Topography Measurements (각막지형도(topography) 각막곡률로부터 토릭 각막형상의 수식화)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • Purpose: To represent the shape of toric corea in the elliptical function for the determination of curvature distribution and lacrimal thickness between cornea and contact lens when the lens is fitted. Methods: Topography measurements of corneal curvature and curvature equation derived from the assumed elliptical function were evaluated using the Excel program which included the necessary equation derived. Results: Mathematical expressions for the cornea whose ribbon shaped-topography image, in which the center does not coincide with the corneal apex, can be determined. Conclusions: For the application where the higher accuracy on the cornea is not required, such as higher order aberration, the cornea cal be expressed in the simple elliptical function.

Implementation of 3D Motion Display Viewer Based on Kalman Filter Using the 9-Axis Sensor (9축-센서를 활용한 칼만필터 기반 3차원 모션 디스플레이 뷰어 구현)

  • Moon, Seongjoo;So, Kyoungyoung;Ko, Kwangman
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.12
    • /
    • pp.585-588
    • /
    • 2015
  • The technical challenge of 3D image display using the wireless sensor were applied to variable areas and scopes. This techniques need to very accurate location and speed informations and recognitions to moving objects. The tracking challenges of the moving objects location that combined 3D location and speed sensor were applied to sports and healthcare areas. This areas seek to the accuracy and collections and tightly related to image display and analysis techniques. In this paper, We developed the 3D motion display that can be monitor moving objects on the 3D virtual space. For this works, we constructed the database that collected informations through 9-axis sensor and demonstrated the result of 3D motion display on the Window based environments.

Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis (미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구)

  • Lee, Nam-Ki;Choi, Dong-Soon;Jang, In-San;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.304-313
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the stress distribution in bone and displacement distribution of the miniscrew according to the length and number of the miniscrews used for the fixation of miniplate, and the direction of orthodontic force. Methods: Four types of finite element models were designed to show various lengths (6 mm, 4 mm) and number (3, 2) of 2 mm diameter miniscrew used for the fixation of six holes for a curvilinear miniplate. A traction force of 4 N was applied at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$ to an imaginary axis connecting the two most distal unfixed holes of the miniplate. Results: The smaller the number of the miniscrew and the shorter the length of the miniscrew, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. Most von Mises stress in the bone was absorbed in the cortical portion rather than in the cancellous portion. The more the angle of the applied force to the imaginary axis increased, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. The maximum von Mises stress in the bone and maximum displacement of the miniscrew were measured around the most distal screw-fixed area. Condusions: The results suggest that the miniplate system should be positioned in the rigid cortical bone with 3 miniscrews of 2 mm diameter and 6 mm length, and its imaginary axis placed as parallel as possible to the direction of orthodontic force to obtain good primary stability.

Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays (Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율)

  • Kim, Wuon-Shik;Hah, Suck-Ho;Hwang, Sun-Tae;Oh, Jang-Jin;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1987
  • Central axis percentage depth-doses, P(%), were measured at the points from the 2.5cm depth of reference point to 20 cm depth with 2.5 cm interval. Distance from the X-ray target to the water phantom($30{\times}30{\times}30cm^3$) surface was 1 m, and at this point three different beam sizes of $5cm{\phi},\;10cm{\phi},\;and\;15cm{\phi}$ were used. While the X-ray tube voltage varied from 150 to 250 kV, the tube current remained constant at 5 mA. Absorbed dose rate in water, $\dot{D}_w$, was determined using the air kerma calibration factor, $N_k$, which was derived from the exposure calibration factor, $N_x$, of the NE 2571 ion chamber. The reference exposure rate, $\dot{X}_c$, was measured using the Exradin A-2 ion chamber calibrated at ETL, Japan. The half value layers of the X-rays determined to meet ETL calibration qualities. The absorbed dose rates determined at the calibration point were compared to the values obtained from Burlin's general cavity theory, and the percentage depth-dose values determined from $N_k$ showed a good agreement with the values of the published depth dose data(BJR Suppl. 17).

  • PDF

Relationship of Refractive and Anatomical Changes on Eyes after Alcohol Ingestion (알코올 섭취에 의한 눈의 굴절변화와 해부학적 변화와의 관계)

  • Kim, Jung-Ouk;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • Purpose: This study was to investigate the relevance between refractive and anatomical changes temporarily on the eyes after alcohol ingestion. Methods: Eight subjects (16 eyes) which were $24.5{\pm}1.5$ aged males drunk the alcohol of 0.42 g per kg of body weight within 30 minutes. Refractive errors, the radius of corneal curvature, corneal thickness, pupillary size, intraocular pressure, and the length of the ocular axis at 1 h, 4 h, and 24 h after alcohol ingestion were compared with them of non-alcoholic state. Results: At 1 h after alcohol ingestion, breath alcohol concentration was the highest (p<0.001), more negative spherical power was needed (p<0.05) for correction, pupillary diameter was decreased (p<0.05), intraocular pressure was decreased (p<0.001), and the length of the ocular axis was increased compared with each one of non-alcoholic state. At 4 h after alcohol ingestion, all anatomical changes were the same tendency as at 1 h after alcohol ingestion. But at 24 h after alcohol ingestion, both refractive changes and anatomical changes were not significant compared with them of non-alcoholic state. Conclusions: Temporary changes of refractive error after alcohol ingestion may be related with decrease of intraocular pressure and increase of the length of ocular axis.

A Study on the Accommodative Astigmatism of Near Vision (근거리 주시 시 조절성 난시에 대한 연구)

  • Lee, Hark-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.327-331
    • /
    • 2011
  • Purpose: The purpose of this study was an accurate grasp of the astigmatic change due to eyes accommodation on near vision and suggested problems occurring accommodative astigmatism using near glasses. Methods: 154 subjects(308eyes) from 20 to 40 years selected for this study who had many opportunity of near vision. First, far vision corrective refraction measured using the phoropter, and then both eyes opened simultaneously for maintaining the function of binocular put away dot chart 40 cm. One eye was fogging and the other eye measured near vision astigmatism axis and degrees astigmatism using cross cylinder, and then compared with far astigmatism. Results: Increased degree of astigmatism persons on near vision more than decreased or did not changed degree of astigmatism persons, which could affect visual acuity more than 0.75 diopters in 30 eyes with an increase of 9.7% of total subjects. Direct astigmatism and oblique astigmatism were increased on near vision. Astigmatic axes were rotated base in direction on both eyes and 66.9% of subjects were more than ${\pm}$5$^{\circ}$ rotation. Due to the rotation axis of astigmatism, residual astigmatism is expected to occur and expect to adversely affect the eyes. Conclusions: Long-term using the glasses without correction of increased astigmatic and rotated axis on near vision should occur new residual astigmatism and increase the asthenopia also. Considered to be taken astigmatic change on near vision during near refraction examination.