• Title/Summary/Keyword: 추천 성과

Search Result 1,717, Processing Time 0.028 seconds

Effective Management Interval Focused on Professional Mechanical Tooth Cleaning (전문가 치면세균막관리 중심의 예방관리프로그램의 효과적인 관리주기)

  • Cho, Min Jeong
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.508-515
    • /
    • 2017
  • This study was conducted to investigate the optimal management interval in 33 healthy adults by observing changes in oral health on the basis of the plaque control index and gingival index. When plaque control score was compared according to the period, it was found that oral hygiene management was the best in the fourth visit (p<0.05). Improved oral hygiene status was observed during the 3- and 6-month follow-up (p<0.05). Regarding gingival index, the fourth visit showed the healthiest gingival status (p<0.05). At the 3-month follow-up, the gingival index worsened, but a healthy gingival status was attained by 6-month follow-up (p<0.05). The plaque control score according to interest in dental health showed that the 'interested' group had good oral hygiene management (p<0.05). As a motivation for oral hygiene status and gingival health, examination with a 'phase contrast microscope' in the first visit and calculation of the 'evaluation index' in the follow-up visit tended to improve the patients' ability for oral hygiene management (p>0.05). The questionnaire survey showed, that the optimal management interval was 1, 3, and 6 months. As a result, with the effective management interval for the preventive management program focused on professional mechanical tooth cleaning, which was administered weekly, the maximum ability for oral hygiene management was attained at the fourth visit. The effective management period was 1 month. The use of a phase contrast microscope and the calculation of the evaluation index for oral hygiene management could influence the motivation to improve oral hygiene management.

Morphological Characteristics of Growth of Rice and Barnyardgrass under Various Cropping Patterns - V. Difference in Morphological and Anatomical Response to Thiobencarb (재배양식(栽培樣式)에 따른 벼와 피의 생장(生長) 및 해부형태학적(解剖形態學的) 차이(差異) - V. 재배양식(栽培樣式)에 따른 제초제(除草劑) Thiobencarb에 대(對)한 벼와 피간(間)의 해부형태학적(解剖形態學的) 반응(反應) 차이(差異))

  • Chon, S.U.;Guh, J.O.;Kwon, S.L.
    • Korean Journal of Weed Science
    • /
    • v.14 no.3
    • /
    • pp.212-222
    • /
    • 1994
  • Thiobencarb retarded the growth of new leaves in only barnyardgrass under dry condition while under water condition the shoot growth of broadcast rice, and both shoot and root growth of barnyardgrass was considerably inhibited. Root elongation of rice and barnyardgrass was severely inhibited only under water condition, while that of transplanted rice was slightly inhibited. Inhibition of shoot and root growth in broadcast, drilled rice and barnyardgrass under water condition was much higher than that under dry condition, whereas the inhibition was less in transplanted rice than direct seeded rice. Microscopically, thiobencarb severely inhibited shoot growth and development of barnyardgrass by inducing tubular-like leaves. The cells of the shoot apices of treated barnyardgrass seedling under dry condition was vacuolated and irregularly arranged. Under water condition, leaf primordia of broadcast rice was constricted, barnyardgrass showed tubular-like leaves, inhibited apices elongation and vacuolated cells(visually lack cytoplasm).

  • PDF

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.

Survey of Sedation Practices by Pediatric Dentists (소아치과의사의 진정법 사용에 대한 실태조사)

  • Yang, Yeonmi;Shin, Teojeon;Yoo, Seunghoon;Choi, Seongchul;Kim, Jiyeon;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.3
    • /
    • pp.257-265
    • /
    • 2014
  • The aim of this study was to establish the appropriate guidelines in the sedation techniques and to organize the continuing education programs for the sedation in future under the direction of Committee on Sedation, Education and Research under the Korean Academy of Pediatric Dentistry(KAPD). The surveys on the sedation technique were performed on 111 organizations which practices the sedation and responded to the survey via online and e-mail by February 2014. The collected survey were analyzed. The purpose of sedation was mainly to manage the children's behavior and its uses were primarily on 3~4 years old children. The most frequent duration of treatment was 1~2 hours to treat both maxillary and mandible. The preferred dosages of sedative drugs were chloral hydrate(CH) 50~70 mg/kg, hydorxyzine(Hx) 1~2 mg/kg, and intramuscular midazolam(Mida IM) 0.1~0.2 mg/kg. The preferred combination of the sedative drugs were CH + Hx + $N_2O/O_2$(67.6%), CH + Hx + Mida submucosal administration (SM) + $N_2O/O_2$(29.7%), and Mida IM + $N_2O/O_2$(23.4%). The administration of additional sedatives was carried out at 48%, mainly using Midazolam. 87.5% of the respondents experienced the adverse effects of the sedation such as vomiting/retching, agitation during recovery, subclinical respiratory depression, staggering, and etc. Among them, only 20% periodically retrain the emergency management protocol. About the discharge criteria for patients after the sedation, the respondents either showed a lack of clear criteria or did not follow the recommended discharge criteria. 86% of the respondents expressed the interests in taking a course on the sedation and they wanted to learn mostly about the sedation-related emergency management, the safe dosage of the sedative drugs, and etc. The use of sedation in pediatric dentistry must be consider a patient's safety as top priority and each dentist must show the evidence of sound practices for the prevention of any possible medical errors. Therefore, KAPD must establish the proper sedation guidelines and it needs to provide the systematic technical training program of sedation-related emergency management for pediatric dentists.

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF

Efficacy of the Antibiotics Chosen by ATS Guideline in the Treatment of Korean Patients with Community-acquired Pneumonia Admitted to a Tertiary Hospital (3차 병원에 입원한 한국 지역사회획득 폐렴 환자에서 미국흉부학회 추천 항생제의 유용성)

  • Oh, Sung-Yong;Park, Sang-Joon;Kang, Kyeong-Woo;Koh, Young-Min;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Choi, Dong-Chull;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.460-470
    • /
    • 1999
  • Background : In 1993, American Thoracic Society (ATS) recommended a guideline for the initial management of adults with community-acquired pneumonia(CAP). However, etiologic organisms and medical system in Korea seem to be different from those in Western countries. Retrospective analysis was done to evaluate the efficacy of antibiotics chosen by ATS guideline in the treatment of Korean patients with CAP admitted to a tertiary university medical center. Methods : Hospitalized patients with CAP at Samsung Medical Center from April 1997 through March 1998 were retrospectively reviewed. Patients who fulfilled all of the following criteria were included in this study : (1) fever ${\geq}38^{\circ}C$ (2) purulent sputum (3) pulmonary infiltrates on chest X-ray. Patients were classified as : 1) ATS group ; patients whose initial antibiotics were chosen by ATS guideline 2) Non-ATS overuse group ; additional antibiotics administered more than those of ATS guideline, and 3) Non-ATS underuse group ; initial antibiotics were insufficient to ATS guideline. Response of empirical antibiotics and etiologic organisms of 3 groups were identified. Results : Sixty-four patients were enrolled. Thirty-six patients were classified into ATS group, 10 patients Non-ATS overuse group, and 18 patients Non-ATS underuse group. Thirty-three patients of 36 ATS group, 9 patients of 10 Non-ATS overuse group, and 14 patients of 18 Non-ATS underuse group showed improvement by initial empirical antibiotics. There was no statistical difference in antibiotic response between 3 groups (p>0.05). S. pneumoniae (12.5%), K. pneumoniae (9.4%), and P. aeruginosa (4.7%), Mycoplasma (3.1%) were the most commonly isolated organisms. In 18 patients with severe CAP, P. aeruginosa was isolated only in 1 patient and Legionella organism not isolated. Conclusion : Initial empirical antibiotics chosen by ATS guideline were effective in the management of Korean patients with CAP admitted to a tertiary hospital. However, well-designed large-scale prospective study is needed to identify etiologic organisms and choose an adequate initial empirical antibiotics in Korean adults patient with severe CAP.

  • PDF

The Key Success Factors of University Entrepreneurship Education: Implication from USA University Cases (대학 창업교육 핵심 성공요인: 미국 대학 사례의 시사점)

  • Choi, Jong-In;Park, Chygwan
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.8 no.3
    • /
    • pp.85-96
    • /
    • 2013
  • Entrepreneurship courses and programs in Korean universities tend to increase steadily but seem to have some limitations. They are usually recognized as another domain of Business Administration. Entrepreneurship program is practical like Business Administration but should be much more interdisciplinary than that. Because Korean Entrepreneurship programs are in the early stage, they must be reinforced with factors such as education culture, faculties, curriculum and relationships with communities. This study aims to get some implications from Entrepreneurship programs have been run by universities in America in order to facilitate Entrepreneurship program in Korean universities. Based on 11 success factors found by our case universities' Entrepreneurship programs and Kauffman Campus, this study has drawn implications of critical success factors of Entrepreneurship programs as follow. First of all, because Entrepreneurship programs should focus on Entrepreneurship mind sets such as innovative idea generation and courage to overcome risk, it is more desirable that Entrepreneurship programs are introduced in all departments of universities such as Arts, Science and Engineering. These programs also need to take interdisciplinary approach and required to be opened from liberal arts course. In order to be sustained during all their academic careers, vision, mission and strategy for Entrepreneurship programs should be based on strong leadership and support of top leaders. Entrepreneurship culture of each university is also one of the most important success factors. Entrepreneurship programs not only as major programs but also as specific Entrepreneurship minors designed for departments such as Arts, Science and Engineering could be considered according to each university's situation. This study also suggest to make a motivation system for Entrepreneurship faculties, Ph d. programs for Entrepreneurship, communication network for Entrepreneurship programs and mentor system in community. To begin Entrepreneurship programs, it also needs to develop good education contents as many as possible. When it concerned with teaching method, project based 4 year program can be suggested to be effective and efficient. To introduce project based program that should be consistent till participants' graduation, university must prepare regulations to support team teaching, mentor and interdisciplinary cooperation. To dissipate the concept that Entrepreneurship is another version of management, this study support the idea that Entrepreneurship programs should be designed and run by independent and central-focused governance system, Entrepreneurship education center.

  • PDF

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Computerized Multiple 15-hue tests for Quantifying Color Vision Acuity (색각 능력의 정량적 평가를 위한 전산화된 다중 15-색상 배열 검사법)

  • Ko S.T.;Hong S.C.;Choi M.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.321-331
    • /
    • 2000
  • Multiple 15-hue tests were designed and implemented on a PC in the study so as to quickly and quantitatively evaluate color vision acuity. Difficulty of the test was control)ed by the value of CDBACC (color difference between adjacent color chips) calculated using a CIELAB formula. The multiple 15-hue tests consist of eight of the hue tests (test 3-10) and three of the basic color (red, green, blue) tests (test 11-13). The 15 colors used for the hue tests were specified by the 15 color coordinates that were located at a constant distance (d = 2. 3. 5. 7, 10, 20, 30. 40) from white reference in the CIE chromaticity coordinate system and were separated by a constant color difference (CDBACC = 0.75, 1.1, 1.8. 2.5. 3.5. 7.5. 11, 14) from the adjacent chips. The color coordinates for the 15 chips for the basic color tests were the same as those of the 15 points spaced equally by a constant color difference (6.87 for the green color test. 7.27 for the red color test, 7.86 for the blue color test) from the white reference along the axis of red, green and blue. Thirty normal subjects who were not color blind were taken to undergo the multiple 15-hue tests. It was observed that most of the subjects correctly arranged color chips for the tests with CDBACC greater than 5, whereas no one correctly answered for those with CDBACC less than 2. Rapid changes in the number of the subjects correctly arranged took place when CDBACC of the tests was between 2 and 4.5. In the basic color tests, unlike the hue tests having similar values of CDBACC, it was seen that the subjects arranged color chips even less correctly. It was found that JNCD (just noticeable color difference) - a measure of color vision acuity was about 3 in average for the subjects. The JNCD was chosen as the value of the CDBACC of the test for which about $50\%$ of the subjects failed to successfully arrange color chips. ERCCA (error rate of color chips arrangement) for the test with CDBACC the same as the JNCD was shown to be about $20\%$. It is expected that the multi 15-hue tests implemented on a PC in the study will be an economical tool to quickly and quantitatively evaluate color vision acuity and, accordingly, the tests can be used for early diagnosis to massive potential patients suffering from diseases (ex. diabetes, glaucoma) which may induce changes in color vision acuity.

  • PDF