• Title/Summary/Keyword: 추가질량

Search Result 153, Processing Time 0.035 seconds

A Study on Safe Vessel Traffic Speeds Based On a Ship Collision Energy Analysis at Incheon Bridge (인천대교 선박 충돌에너지 분석을 통한 선박의 통항안전 속력에 관한 연구)

  • Lee, Chang-Hyun;Lee, Hong-Hoon;Kim, Deun-Bong;Kim, Chol-Seong;Park, Seong-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.593-599
    • /
    • 2016
  • Incheon Bridge is 13.38 km long with an 800 m span, connecting Incheon International Airport and Songdo International City, Per hour 73.8 vessels navigate this space. The purpose of this study was to suggest a safe passing speed based on the displacement of a vessel based on the safety criteria of Incheon Bridge's anti-collision fence, which was designed during its initial construction. As AASHTO LRFD suggested, vessel collision energy, vessel collision velocity, and the hydrodynamic mass coefficient were considered to derive a safe vessel traffic speed. Incheon Bridge's anti-collision fence was designed so that 100,000 DWT vessels can navigate at a speed of 10 knot. This research suggests a safe speed for vessel traffic through a comparative analysis of an experimental ship's (300,000 DWT) speed and cargo conditions, regulation speed has been calculated according to the collision energy under each set of conditions. Additionally, safe traffic vessel's safe speed was analyzed with reference to tidal levels. Results from the experimental ship showed that a vessel of maximum 150,000 DWT is able to pass Incheon Bridge at a maximum of 7 knots with an above average water level, and is able to pass the bridge with a maximum of 8 knots under ballast conditions.

A Study on the Heat Release Characteristics of Fire Load for Performance Based Design of Multiplexes: A Focus on the Heat Release Rate and Fire Spread Rate of Cinema Seats (복합영상관의 성능위주설계를 위한 가연물의 연소발열특성 연구: 객석의자의 열발생률 및 연소확산속도를 중심으로)

  • Nam, Dong-Gun;Jang, Hyo-Yeon;Hwang, Cheol-Hong;Lim, Ohk-Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.11-17
    • /
    • 2020
  • As performance-based design (PBD) has a direct impact on evacuation safety assessments, designing fire scenarios based on real fire tests is essential. To improve the reliability of the PBD for fire safety in multiplexes, information on fire behavior, such as heat release rate (HRR) and fire spread rate, are provided in this study by conducting a standard fabric flammability test. To this end, several chairs were arranged in a pattern that resembled a theater-style seating. The peak HRR and heating value per unit mass for each chair ranged from 415 kW to 988 kW and 15.2 MJ/kg to 23.8 MJ/kg, respectively. The heating values per unit mass of the new and old chairs were 23.6 MJ/kg and 16.7 MJ/kg, respectively. As the quantity of plastic and cushioning materials in the new chairs was more than that of the old ones, the new chairs were more vulnerable to fire hazards. Furthermore, when the chairs were arranged in a line, the fire spread rate was observed to be 0.39-0.42 m/min, regardless of the ignition location. Finally, a fire growth curve showing the peak HRR and fire spread rate was also demonstrated.

CFD Analysis on the Internal Reaction in the SNCR System (SNCR 시스템 내부의 물질 반응에 관한 전산해석적 연구)

  • Koo, Seongmo;Yoo, Kyung-Seun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.63-73
    • /
    • 2019
  • Numerical analysis was done to evaluate the chemical reaction and the reduction rate inside of selective non-catalytic reduction to denitrification in combustion process. The $NO_X$ reduction in selective non-catalytic reduction is converted to not only nitrogen but also nitrous oxide. Simultaneous $NO_X$ reduction and nitrous oxide generation suppressing is required in selective non-catalytic reduction because nitrous oxide influences the global warming as a greenhouse gas. The current study was performed compare the computational analysis in the same temperature and amount of NaOH, and in comparison with the previous research experiments and confirmed the reliability of the computational fluid dynamics. Additionally, controlling the addition amount of NaOH to predict the $NO_X$ reduction efficiency and nitrous oxide production. Numerical analysis was done to check the mass fraction of each material in the measurement point at the end of selective non-catalytic reduction. Experimental Value and simulation value by numerical analysis showed an error of up to 18.9% was confirmed that a generally well predicted. and it was confirmed that the widened temperature range of more than 70% $NO_X$ removal rate is increased when the addition amount of NaOH. So, large and frequent changes of the reaction temperature waste incineration facilities are expected to be effective.

Estimation Error and Reliability of Measuring Unit Water Content Test Methods for Fresh Concrete Depending on Mix Design Factors at the Laboratory Level (실험실 수준에서 배합변수별 굳지 않은 콘크리트 단위수량 실험방법의 추정오차 및 신뢰성 검토)

  • Park, Min-Yong;Han, Min-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.101-110
    • /
    • 2022
  • In this study, water content tests were performed on various fresh concretes subjected to different binder compostions to review the estimation errors and reliability of water content test methods. Micro-oven drying method, air-meter method, capacitance method and microwave penetration method were used to estimate water content of fresh concrete. Errors in water content estimation were analyzed by each test method. Regardless of the test method of water content, the estimation error was less than 5 %, and in the case of the test using mortar, the error in the estimation value was relatively large. In addition, based on the test results of water content of various concrete, the probability density function in which the estimation error for each test method becomes the population was analyzed. Water content test methods of fresh concrete which using concrete samples showed high estimate reliability of 97 % within the estimation error range of ± 10 kg/m3. On the other hand, the reliability of water content test method using mortar samples was lower.

Glyceryl Esterification of Fibroin Peptide by Papain (파파인을 이용한 피브로인 펩타이드의 글리세릴 에스터화 반응)

  • Jeong, Jae-Ho;Lee, Shin-Young;Hur, Won
    • KSBB Journal
    • /
    • v.25 no.4
    • /
    • pp.395-400
    • /
    • 2010
  • Papain hydrolysate of fibroin was found to be mainly composed of several even-numbered peptides that can be produced at a large scale and can be used as a precursor for biological fine-chemicals such as peptide detergents. Thus, the hydrolysate was further modified to synthesize a peptide mixture of glyceryl esters using the identical enzyme for the production of such chemicals. Formation of glyceryl ester of each peptide was confirmed by identifying peaks of the nominal mass shift of +74 Da in mass spectrometry. Analysis of the mass spectra indicated that glyceryl esters of di- and tetra-peptides were the major constituents of the mixture and that alanylglycine was most preferentially esterified. It also suggests that papain prefers dipeptide to tetrapeptide and alanine to serine or tyrosine at $P_2$ position as substrate for glyceryl esterification. The glyceryl esters were recovered using ion exchange resin and the yield of glyceryl esterification recorded was 17.8% by weight.

Non-HF Type Etching Solution for Slimming of Flat Panel Display Glass (평판디스플레이용 유리의 박판화공정을 위한 비불산형 식각액)

  • Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.27 no.1
    • /
    • pp.101-109
    • /
    • 2016
  • The purpose of this research was to develop a flat panel display device's glass etchant which can replace hydrofluoric acid. The glass etchant was composed of 18~19% wt% of ammonium hydrogen fluoride, 24~25 wt% of sulfuric acid, 45~46 wt% of water, 4~5 wt% of sulfate and 7~8 wt% of fluoro-silicate. By replenishing the etchant which has the amount of 5% of initial solution's mass, it was possible to reuse the etchant continuously. The developed etchant showed $5{\mu}m/min$ of etching rate at $30^{\circ}C$. The reusable etchant, with replenishing 5% of initial etchant mass showed the stable etching rate, which has the deviation of less than $0.1{\mu}m/min$ etching rate. The glass surface of flat panel display device created from our etching process was in good condition with any defects such as pin hole and dimple.

Removal of Fluoride Ions from Electronic Industrial Wastewater Using Lime Stone Slurry (초미분말 석회석 현탁액을 이용한 전자산업 폐수 불소이온 제거연구)

  • Park, Hyeon Soo;Park, Yeon Soo;Jung, Goo Ill;Kim, Jae Woo;Jo, Young Min
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.258-263
    • /
    • 2018
  • This study attempted to utilize ultrafine precipitated calcium carbonate for fluoride removal from the wastewater of electronics industries. An average particle size of the calcium carbonate was $0.96{\mu}m$, and pH of the aqueous slurry was 10 with 70% in mass. The suspension solution showed approximately 2 mL/hr of the sedimentation rate. The present calcium carbonate solution could be comparable to the conventional aqueous calcium source, $Ca(OH)_2$, for the neutralization and removal of fluoride ions. Depending on the amount of an additional alkali source, less amounts of test Ca-source slurries were required to reach the solution pH of 7.0 than that of using the aqueous calcium hydroxide. It was also found from XRD analysis that more calcium fluoride precipitates were formed by the addition of calcium carbonate solution rather than that of calcium hydroxide. In addition, Minteq equilibrium modelling estimated various ion complexes of fluoride and calcium in this process.

Evaluation of Exposure to Pyrethroid Pesticides according to Sprayer Type using Biological Monitoring (생물학적 모니터링을 이용한 분무기 형태에 따른 피레스로이드 농약 노출량 평가)

  • Song, Jae Seok;Choi, Hong Soon;Yu, Ho Young;Park, Byung Gon;Kwon, Daeho
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.4
    • /
    • pp.300-304
    • /
    • 2016
  • The aim of this study were to evaluate the exposure level of pyrethroid pesticide according to spraying machine type. The urinary metabolites of pyrethroid pesticide in apple farmers were analyzed to determine the exposure level of pyrethroid pesticide. The result shows that, the spraying volume was greater in SS sprayer group than in power sprayer group. But multi variate analysis which adjust spraying volume and field area, there were no difference of urinary metabolites between two sprayer machine. To make more accurate model of pesticide exposure, the factors influencing pesticide exposure should be determined and further study should be done.

Elastic Behavior of Contact Lense(I) : Effect of Vibration (콘택트 렌즈의 탄성에 관한 연구(I) : 진동에 의한 영향)

  • Kim, Dase-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.1-16
    • /
    • 1999
  • Differential equations and its numerical solution program using Turbo-C were formulated to describe the radical distribution and average displacement amplitude of vibrating dehydrated contact lens(HEMA) driven by sinusoidal or rectangular pressure. The natural resonant frequency of the lens diaphram(thickness 0.08mm, diameter 14mm, curvature radius 8mm) was measured to be 5730 Hz from the extrapolation of frequency vs addedmass to the diaphram curve. The Young's modulus of the lens was measured to be $4{\times}10^9$ Pa with altering the original shape. The effect of parameters such as thickness, effective radius, damping coeff., amplitude of driving pressure on the vibration characteristics was illustrated by the computer simulation of the derived program. When the frequency of driving pressure coincides with the integral multiple of fundamental resonance frequency of the lens the wave pattern changes from arc to bell-shape along the radial position of the diaphram. If this happens to the contact lens on the cornea in vivo, it might create the feel of pull of the lens due to the increased rise of central part of the lens.

  • PDF

Critical Speed Analysis of a 75 Ton Class Liquid Rocket Engine Turbopump due to Load Characteristics (75톤급 액체로켓엔진 터보펌프의 하중 특성에 따른 임계속도 해석)

  • Jeon, Seong-Min;Kwak, Hyun-D.;Hong, Soon-Sam;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.22-29
    • /
    • 2011
  • Critical speed of high thrust liquid rocket engine turbopump is obtained through a rotordynamic analysis and a unloaded turbopump test is peformed for validation of the numerical model. The first critical speed predicted by the numerical analysis is correlated well with the test result for the bearing unloaded rotor condition only considering mass unbalance load. Using the previous rotordynamic model, critical speed variation is estimated as a function of varied bearing stiffness due to pump and turbine radial loads with relative angle difference. From the numerical analysis, it is found that the relative angle difference of pump and turbine radial loads greatly affects the critical speed. However, additional axial load reduces the effect derived from the relative angle difference of radial loads.

  • PDF