• Title/Summary/Keyword: 최적 환기시스템

Search Result 76, Processing Time 0.024 seconds

Development of Exhaust Fan with an Embedded Controller for Windowless Swine Housing (무창돈사를 위한 컨트롤러 일체형 환기팬 개발)

  • Kim, Woong
    • Journal of agriculture & life science
    • /
    • v.50 no.2
    • /
    • pp.187-194
    • /
    • 2016
  • The purpose of this study was to analyze temperature distribution characteristics using a model swine housing for temperature sensor adjustable positioning and developed a sensor and controller embedded exhaust fans utilizing ICT fusion technology for windowless swine housing. Temperature measured by the sensor attached on the exhaust fan was also determined that there is no problem, the temperature is located in the upper fan given the measured errors shown in the 1℃ temperature difference between the lower temperature than the other positions in the model swine housing. The performance of the exhaust fan at maximum output was found to be 1920rpm, air flow rate 125㎥/min. When the open area ratio of 70% one proper air volume of the exhaust fan was found to be 75㎥/min, 60pa. Maximum efficiency in all of the output of the exhaust fan is exhibited at about 70% open area ratio of the damper. The number of revolution of the exhaust fan was 1920rpm when the output was a maximum of 100%. AC output phase of the pulse duty ratio change of the controller was shown to change without delay. It was determined that the instant fan speed control is possible.

An Analytical Methodology for Evaluating Radiological Protection Alternatives Using Analytical Hierarchy Process (계층화 의사결정법을 이용한 방사선방호선택 대안결정에 관한 해석적 방법론)

  • Sa, Sang-Duk;Narita, Masakuni
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.99-107
    • /
    • 1994
  • This study aims to introduce a prescriptive methodology to comprehensively support the analysis of decision process by the use of Saaty's Analytical Hierarchy Process for the optimization of radiation protection. The analytical Hierarchy Process for the optimization of radiation protection. The analytical process for the problem of selecting options among given protection alternatives is illustrated with the data of the uranium mine example in ICRP Publ. 55. This technique, unlike other conventional selection method, is considered to provide a useful tool for the protection manager with respect to its ease of use and simplification in the choice of optimal alternative associated with radiological protection.

  • PDF

Experimental Study on the Determination of Critical Velocity for the Case of Fire in Long Traffic Tunnels (장대 교통터널 화재시 임계속도 결정에 관한 실험적 연구)

  • Yoon Chanhoon;Yoon Sungwook;Yoo Yongho;Kim Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.1 s.60
    • /
    • pp.85-94
    • /
    • 2006
  • In this study, scaled model tests were carried out to decide the optimal critical velocity, to prevent back layering in the case of fire in a long traffic tunnel. Realistic estimates were made for the time required for people to escape ken the tunnel and far the time required by the ventilation operator to increase the system speed to full capacity. The analysis, predicts that the emergency ventilation will start about 240 seconds after the tunnel fire. It was also found that prevention of back layering would occur within 4 minutes after fan operation. To find out optimal critical velocity, a 1/50 scaled model tunnel(diameter : 0.2 m and length : 20 m) based on the Froude similarity technique was constructed. Changing $\beta$ values in the Tetzner's equation, smoke propagation was observed. From the experiment, it was concluded that using a $\beta$ value of 0.5 to prevent back layering successfully allowed time for safe evacuation.

Development of Optimum In-process Electrolytic Dressing System in the UItraprecision Grinding (초정밀 연삭용 최적 연속 전해드레싱 시스템의 개발에 관한 연구)

  • 이은상
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.82-103
    • /
    • 1995
  • In recent years grinding techniques for precision machining of brittle materials used in electric optical and magnetic parts have been improved by using superabrasive wheel and precision grinding machine. The completion of optimum dressing of superabrasibve wheel makes possible the effective precision grinding of brittle materials. But the present dressing system cannot have control of optimum dressing of the superabrasive wheel. This study has proposed a new optimum in-process dressing of superabrasive wheel and give very effective control according to gap increase.

  • PDF

Development of Simulation for Vuilleumier Cycle Heat Pump (VM 사이클 히트펌프 설계프로그램의 개발)

  • 박병덕;이기우
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.105-113
    • /
    • 2001
  • 지구환경문제와 에너지문제를 해소하는 한 방법으로서 Vuilleumier 사이클 기관(VM)을 이용한 공조기형 열구동형 히트펌프시스템(VMHP)이 각광을 받고 있다. VMHP의 제작에 있어서는 VM의 각 부분의 이론적 검토 및 최적설계를 위한 해석프로그램의 개발이 필수적이고 최적설계를 위한 설계 기본서의 도출 및 설계자료의 확보가 필요하다. VMHP의 상세한 성능해석이나 설계에 활용 가능한 성능해석프로그램을 개발하였다. 해석은 VM의 시스템의 각 부분을 11개 부분으로 나누어 단열모델해석으로 수행하였다. 열교환기에서의 열전달 성능과 재생기손실, 열전도손실, 셔틀손실, 유동에 의한 압력손실과 열압축측과 열펌프측 사이의 마찰손실, 피스턴실 및 로드실의 마찰손실을 고려한 해석을 수행하였다. 해석에 의한 계산치의 정확성을 본 해석결과를 이용하여 제작한 시험기에 의해 비교하였다. 계산치와 시험기에 의한 전체성능을 비교하였고 또한 각각의 손실에서 고유한 파라미터를 추출하여 그 파라미터의 변화에 따른 열손실 전체의 변화 정도를 파악하여 실험치와 계산치의 정상적인 비교로부터 성능해석의 정도를 비교하였다. 비교결과에 의해 난방능력은 8%, 냉방능력은 19%의 최대오차로서 본 해석결과가 VMHP의 설계를 위해 유용한 수단으로 사용될 수 있음을 확인하였다.

  • PDF

A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation (Oversized Exhaust System) (도로터널 화재시 반횡류식 환기방식에서의 최적배연 연구(대배기구 방식))

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.79-84
    • /
    • 2009
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75m/s and 2.5m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

On-site Application of a Vehicle Tunnel Ventilation Simulator (도로터널 환기시뮬레이션 모델 현장적용 연구)

  • 이창우;김효규
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.319-327
    • /
    • 2001
  • Introduction of new design tools has been required to optimally design and operate the ventilation system of long vehicle tunnels.. The demand has led to wide spread use of the simulation technique throughout the would to analysis the dynamic relationship among the variables associated with vehicle tunnel ventilation. This paper aims at performing on-site study at local tunnels to test the applicability of NETVEN, a simulation model vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels model of vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels employing different ventilation systems as well as traffic methods. There were some discrepancies sound between the simulation output and measurements and the following four factors are considered to mainly cause those disagreement. (1) The real situation shows distinctive transient and retarding characteristics with respect to air flow and contaminant dispersion, while ventilation forces are not steady-state and in particular those traffic and climatic variables show significant instantaneous variation. (3) Near the exit portal, the CO levels show bigger differences. The general trend is that data with higher CO concentrations carry bigger discrepancies. Turbulent diffusion is though to be the main reason for it and also contribute to the fact hat the highest CO concentrations are found at the locations somewhat inward, not at the exit portals. (4) Higher traffic rate results in higher discrepancies of ventilation velocity. Along with the exhaust characteristics, the vehicle aerodynamic characteristics need to be studied continuously in order to reduce the velocity disagreement.

  • PDF

A study on applications of the natural ventilation pressure(NVP) in local tunnels (터널내 자연환기력(NVP) 적용방안 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.269-285
    • /
    • 2014
  • In spite of the importance of the natural ventilation pressure(NVP) in tunnels for the optimal design of the ventilation system, there have been only few studies on the NVP because its measurement and quantitative analysis are not straightforward. This study aims at quantifying the amount of the NVP with the terrain and meteorological data for the local major tunnels. And ultimately this will lead to developing the guidelines for quantifying and applying NVP for the optimal design of tunnel ventilation system. 22 local tunnels in the major routes are studied for the NVP quantification. NVP derived from the meteorological data is in the range of 20~140 Pa, while NVP estimated from the terrain data ranges from 20 to 200 Pa. Since the jet fan pressure is about 10~15 Pa per unit, the minimum level of NVP expected in the local tunnels is larger than the pressure rise by one unit of the ordinary jet fan. This implies that NVP in local tunnels should be quantified and be taken into consideration for the economic and safe ventilation design. The barometric pressure difference between tunnel portals is found to be the most influential factor, accounting for 61% of the NVP, while the wind pressure acting on the portals and the chimney effects occupy 22% and 17%, respectively.

Simultaneous Removal of Gaseous and Particulate Pollutants in a Room With Optimal Ventilation System (최적 환기 시스템에 의한 실내에서의 가스 및 입자상 오염물의 동시 제거에 관한 연구)

  • 조용수;여석준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.433-434
    • /
    • 2003
  • 급속한 산업 발전과 더불어 산업전반에 걸쳐 환경문제가 심각해지면서 생활의 질적 향상에 따른 쾌적 환경을 추구하기 위해 실내와 작업장 내에 떠 있는 먼지나 유해가스 등의 오염물질로 인한 직업성 질병에 대한 관심이 높아지고 있다 실내ㆍ외를 불문하고 환경오염이 인체 건강 및 위생에 미치는 영향은 오염물에 대한 노출시간에 관계하기 때문에 하루의 대부분의 시간을 실내에서 생활하는 현대인에게 실내 환경의 질은 아주 중요하다. 질의 물리적 특성에 따른 가스상, 입자상의 거동 및 농도분포에 대한 수치 해석적 연구는 매우 미흡한 실정이다. (중략)

  • PDF

A Study on Jet Fan Start Time in Medium-Length Tunnel Fires (중규모터널 방재용 제트팬 초기 가동시간에 관한 연구)

  • Kim, Doo-Young;Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.465-474
    • /
    • 2010
  • Although the number of medium-length road tunnels, less than 1 km in length, has increased recently more than 30 percent each year, their ventilation and fire safety system design guidelines have not been established yet. The guidelines for long tunnel design are adopted even for the medium-length road tunnels. Therefore the necessity is brought up to optimize the ventilation and fire safety systems based on their own design guidelines. This study aims at determining the optimal start time of jet fan in case of 20 MW fires by analyzing smoke backlayering range, temperature distribution, range of poor visibility, evacuation time and critical velocity. The CFD study results are expected to contribute to propose the optimal fan operation mode.