• Title/Summary/Keyword: 최적 온도 계측 위치

Search Result 8, Processing Time 0.045 seconds

CFD Analysis Based Optimal Temperature Measurement (CFD 해석 기반 실내 최적 온도 계측)

  • Lee, Min-Goo;Park, Yong-Kuk;Jung, Kyung-Kwon;Yoo, Jun-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.735-738
    • /
    • 2011
  • This paper proposed the method to find out the optimal sensing point of temperature in test-bed with the sensor of temperature, such as real residence. We selected optimal locations by checking temperature change which was simulated by the means of CFD (Computational Fluid Dynamics) and the variation of air flow. We installed 30 temperature sensors in real place. After that, we compared the real one with the result of simulation.

  • PDF

TOF spectrometer를 사용하는 중이온 후방산란장치 (HIRBS)

  • Kim, Jun-Gon;Kim, Young-Seok;Kim, Gi-Dong;Hong, Wan;Woo, Hyung-Joo;Choi, Han-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.76-76
    • /
    • 1999
  • 한국자원연구소 제작된 TOF spectrometer는 입자의 비행시간과 에너지를 동시에 측정 기록하여 질량분별된 에너지 스펙트럼을 얻고자 하는 목적으로 제작되었다. 그러나 질량분별이 필요치 않은 후방 산란실험에서는 비행시간의 측정만으로 훌륭한 에너지 계측기가 된다. 중이온 산란분석법(heavy ion RBS)은 He을 사용하는 산란분석법에 비하여 원리적으로 분해능이 우수하나 사용하는 반도체 검출기의 에너지 분해능의 불량이 이러한 장점을 상쇄하는 실정이다. 그러나 TOF spectrometer를 중이온 산란실험의 에너지 계측기로 사용하면 H, He에 대한 반도체 검출기 정도의 낮은 에너지분해능 수준을 유지할 수 있으므로 중이온 산란실험의 원리적인 장점을 살릴 수 있다. 한국자원연구소에서는 He RBS의 취약점으로 지적되어온 medium elements에 대한 질량분해능과 깊이 분해능을 향상시키고자 140$^{\circ}$ 산란각에 TOF spectrometer가 위치하는 Heavy Ion Rutherford Backscattering Spectrometry (HIRBS) 시스템을 설계하였다. 설계된 TOF spectrometer를 채용하였을 때 기대되는 질량분해능 향상효과와 분석의 최적조건에 관하여 논한다.

  • PDF

램제트 엔진의 지상시험용 Vitiated Air Heater를 이용한 Dump형 연소기의 연소성능에 관한 실험적 연구

  • 노우용;윤현진;손창현;이충원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.11-11
    • /
    • 2000
  • 액체렘제트 엔진에서는 고온·고속의 공기가 공기흡입구로 유입되기 때문에 고성능 램제트 연소기의 설계를 위하여 실제 비행조건을 모사할 수 있는 고온 고속의 공기 발샐장치가 필요하다. 본 연구에서는 수소연소에 의해 Vitiated Air를 발생시키도록 설계된 Vitiated Air Heater(VAH)를 제작하였으며, VAH의 성능평가를 통하여 80∼120m/s 와 400∼800K 범위에서 손쉽게 속도와 온도의 조절이 가능하고 균일한 속도 및 온도분포로 대기공기와 같은 Vitiated Air를 얻을 수 있었다. 그리고 VAH을 연결하여 Dump형 연소기의 특성을 실험하였다. 액체 램제트 엔진에 있어서 공기흡입구가 하나인 Dump형 연소기에 주요변수로서 흡입공기의 온도와 공연비를 변화시키면서 연소기내의 화염형상을 관찰하고, 온도분포를 계측하였으며 Injection 위치에 따른 화염현상을 관찰하였다. 각 경우의 연소효율을 계산하여 실험범위에서의 최적 연소조건을 제시하였다.

  • PDF

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

Long-term Tilt Prediction Model for the L-type Retaining Wall Adjacent to Urban Apartments (도심지 아파트 L형 옹벽의 장기 경사거동 예측모델)

  • Koo, Ki Young;Seong, Joo Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.134-142
    • /
    • 2012
  • This paper presents a study of system identification on the tilt response of the L-type retaining wall located at Tanhyun 11th ACE Apartment, Ilsan in order to understand mechanism how the structure behaves in operational conditions and to provide a reference tilt values for assessing structural abnormality. The retaining wall was extraordinarily tall (14m) in urban area so the long-term monitoring system had been installed with 3 tilts-meters and 9 temperature sensors operational from Oct 2004 upto Nov 2007. By using 5-months continuous data in which all the 12 channels were up and running, the two prediction models, 1) the linear model, and 2) the state-space equation (SSE) model, have been identified by finding the best fitness model among all possible 511 combinations of input temperatures out of the 9 temperatures. The linear model which was simple in the model structure achieved the validation fittness of 68% due to the fact that the static model wasn't able to represent thermal dynamics. The SSE model achieved the validation fitness of 90% which was quite accurate considering various unexpected noises happening in field measurements.

A Study on the Fabrication of Heater based on Silicone Rubber (실리콘러버 기반의 히터제작에 관한 연구)

  • Jeong-Oh Hong;Jae Tack Hong;Shin-Hyeong Choi
    • Advanced Industrial SCIence
    • /
    • v.2 no.2
    • /
    • pp.9-15
    • /
    • 2023
  • Since silicone rubber heaters are flexible, they can be directly attached or installed in objects to be heated even in flat, curved or three-dimensional shapes. Since the current heating method heats the entire object to be heated and raises it to a required temperature, ignoring areas or positions where heat is not required, partial intensive heating cannot be performed. When using multi-heating zones, rather than heating the entire object to be heated, only the parts that need heat are intensively heated according to the process, so it is possible to heat quickly by local location by applying different amounts of heat with a small amount of electric capacity to each place that needs heat, and heat energy can reduce. In this study, the temperature and heating time of the partially concentrated region in the multi-heating region structure are measured so that a uniform temperature or temperature difference occurs in the region requiring thermal fusion. In order to determine the optimal power density range and reduce capacitance, the safety of a silicon rubber heater manufactured with a multi-heating zone structure is investigated. If the silicon rubber heater is manufactured in a multi-heating method, the multi-intensive heating technology can be ideally applied to all heating processes.

Reduced-Scale Experiments of the Partial Smoke Extraction System in Tunnel Fires (풀화재를 이용한 터널화재 부분배연 모델실험)

  • Lee, Eui-Ju;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.58-64
    • /
    • 2006
  • Smoke extraction in tunnel fire is investigated experimently with thermal model. The object is a immersed tunnel, of which the partial extraction system exists between the tubes. The model tunnel is measured 12 m long, 0.5 m wide and 0.35 m high. The fire is simulated to pool fire and the size corresponds to full scale fire of 5 MW based on Froude modeling. The performance of partial extraction system is determined under two ventilations, natural and longitudinal ones. The results show that compared with longitudinal ventilation, the smoke extraction efficiency of natural ventilation is increased about 30% because of smoke stratification in tunnel. Also the efficiency is identical to the iso-thermal model. The results will be help for activation of the ventilation system in emergency such as in the event of tunnel fires.

Optimum Monitoring Parameters for the Safety of Mechanical Seals (미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자)

  • Soon-Jae Lim;Man-Yong Choi
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.214-219
    • /
    • 1997
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are generally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage, crack, breakage, fast and severe wear, excessive torque, and squeaking results in big problems. To identify abnormal phenomena on mechanical seals and to propose the proper monitoring parameter for the failure of mechanical seals, sliding wear experiments were conducted. Acoustic emission, torque, and temperature were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. Except for the initial part of every experiment, the variation of acoustic emission was well coincided with torque variation during the experiments. This study concludes that acoustic emission and torque are proper monitoring parameters for the failure of mechanical seals. The intensity of acoustic emission signals is measured in root mean square voltage. Temperature of sealing face will be used as a parallel parameter for increasing the reliability of monitoring system.

  • PDF