• Title/Summary/Keyword: 최적유지관리

Search Result 624, Processing Time 0.028 seconds

A Study on the Relation between Dynamic Deflection Modulus and In-Situ CBR Using a Portable FWD (소형FWD를 이용한 노상토의 동적변형계수와 현장 CBR의 상관 연구)

  • Kang, Hee Bog;Kim, Kyo Jun;Park, Sung Kyoon;Kim, Jong Ryeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.149-155
    • /
    • 2008
  • The road construction, as part of effort to ease the worsening traffic, has been underway throughout the nation, while the existing road has been increasingly losing its load carrying capacity due to such factors as heavy traffic and weathering. In the case of site, the soil type, plasticity index, and specific gravity were SC, 12.2%, and 2.66, respectively. The maximum dry density, optimum moisture content and modified CBR were $1.895g/cm^3$ (Modified Compaction D), 13.6%, and 16.2%, respectively. A correlation of coefficient expressed good interrelationship by 0.90 between the CBR estimated from a dynamic penetration index of dynamic cone penetrometer test and a deformation modulus converted from a dynamic deflection modulus obtained from a portable FWD test.

The Structural Reinforcing of PCC-Deck with Cantilever (캔틸레버를 갖는 PCC-Deck의 구조보강)

  • Lho, Byeong-Cheol;Kim, Chang-Kyo;Park, Jong-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.21-30
    • /
    • 2013
  • LB-Deck is one of the widely used member in interior part of girders as a permanent formwork in structures, but it is not easy to apply to the exterior part of girder due to the overturning and excessive deflection. Considering allowable deflection and safety of the exterior part, Precast Concrete Cantilever Deck (PCC-Deck) is proposed with normal LB-Deck in inner part and extended bars of LB-Deck in outer part. Both numerical analyses and experimental tests were compared to check the safety and allowable deflection for 6 types of PCC-Deck, and D-type (with 16 mm top bar, 6 mm lattice bar, 12 mm bottom bar) is suggested as an optimal structural reinforcement to the 28 kN of maximum load and 27.49 mm of final deflection. The load resisting ratio of D-type under working load of 10 kN was about 2.8 times and 77.5% of improvement was observed.

Strain-Hardening Cementitious Composites with Low Viscosity Suitable for Grouting Application (그라우팅에 적합한 점성을 갖는 변형률 경화 시멘트 복합재료)

  • Lee, Bang Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.55-63
    • /
    • 2012
  • This paper presents materials and processing technique to manufacture low viscous strain-hardening cementitious composite which is suitable for structures requiring low viscosity of materials. The micromechanics and fracture mechanics tools coupled with processing techniques were adopted to achieve low viscosity of composites as well as high tensile strain capacity. Optimal volume and length of fibers and interfacial properties between fibers and matrix for composites with tensile strength of 2~3MPa were determined on the basis of the micromechanical analysis and the steady-state cracking theory. Then six mixtures were determined and the experiment was carried out to evaluate the viscosity and uniaxial tensile performance of those. From the test results, it is verified that the strain-hardening cementitious composite with low viscosity suitable for grouting applications in fresh state as well as high ductility over 1.5% in hardened state can be feasible.

Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor (광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석)

  • Kim, Ho Sun;Jang, Hwa Sup;Yang, Dong Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • In general, load carrying capacity, one of the load & resistance capacities in bridges, has more margins than the load carrying capacity evaluated with theoretical methods, unless there are severe damages, defects or material deterioration phenomena that can have a great impact on the behavior of bridges. However, errors have been already included in the current processes of loading tests and structural analysis for measuring load carrying capacity, thus devaluing the reliability of response adjustment factor. Therefore, this study found out the problems of existing electric resistance strain and displacement sensors in sensor suite to solve the problems with sensors and the errors in the appropriateness of structural analysis model, thereby leading to the changes into an optical fiber smart sensor with excellent performance. Besides, the study attempted to ensure the accuracy of response adjustment factor by selecting the optimal models through the interpretation of various structural analysis models.

An Experimental Study on Characteristics of Flexural Behavior in RC Member with Mineral Admixture under Calcium Leaching Degradation (칼슘용출 열화 조건에서 광물질 혼화재를 사용한 RC부재의 휨 거동에 관한 실험적 연구)

  • Lee, Gyung-Jong;Choi, So-Yeong;Choi, Yoon-Suk;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.16-25
    • /
    • 2018
  • Concrete is a suitable construction material for long-term structure, however, it is needed to understand the calcium leaching damage caused by exposure to underground pure water for a long time. In this paper, it is experimentally investigated that the characteristics of flexural behavior in RC member damaged by calcium leaching degradation. From the test results, when calcium leaching is happened, yielding load and flexural rigidity is reduced, neutral axis depth and displacement is increased. That is, calcium leaching degradation adversely affects RC member performance. And, when the mineral admixture is used in the calcium leaching environment, it is considered that the optimal replacement ratio should be prepared according to the type of mineral admixture.

Smart Monitoring System to Improve Solar Power System Efficiency (태양광 발전시스템 효율향상을 위한 스마트 모니터링 시스템)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.219-224
    • /
    • 2019
  • The number of solar power installation companies including domestic small scale (50kW or less) is increasing rapidly, but the efficient operation system and management are insufficient. Therefore, a new type of operating system is needed as a maintenance management aspect to maximize the generation amount in the current state rather than the additional function which causes the increase of the generation cost. In this paper, we utilize Big Data and sensor network to maximize the operating efficiency of solar power plant and analyze the expert system to develop power generation prediction technology, module unit fault detection technology, life prediction of inverter components and report technology, maintenance optimization And to develop a smart monitoring system that enables optimal operation of photovoltaic power plants such as development of algorithms and economic analysis.

An Experimental Study on the Self-Healing Performance of Solid Capsules According to the Composition Ratio of Crystal Growth Type Inorganic Materials (결정성장형 무기재료 조성비에 따른 고상 캡슐의 자기치유 성능에 관한 실험적 연구)

  • Nam, Eun-Joon;Oh, Sung-Rok;Kim, Cheol-Gyu;Choi, Yun-Wang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.16-22
    • /
    • 2021
  • In this paper, a solid capsule was prepared using a crystal growth type inorganic material capable of hydration reaction. The solid capsules were mixed at 3, 5, and 10% according to the composition ratio of 8:2, 7:3, 6:4 based on the cement mass, and the self-healing mortar was mixed, Durable healing properties were evaluated through the water permeability test. As a result of the water level permeability test, the effect of optimally improving the natural healing performance was shown by mixing the solid capsules prepared in a composition ratio of 7:3 of the solid capsules. In the case of a crack width of 0.3mm or less, it is estimated that more than 90% of the self-healing performance can be secured. As a result, it was judged that the self-healing performance of the solid capsule had an effect on the durable healing properties through the water permeability test, It is judged that there is a tendency to improve self-healing performance according to the mixing of solid capsules.

Analysis of Applicability of Active Noise Control (ANC) technique for Reducing Inter-Floor Noise in Apartment Buildings (공동주택 층간소음 저감을 위한 능동소음제어(ANC) 기술 적용가능성 분석)

  • Nam, Jin-Won;Kim, Ho-Jin;Kim, Jun-Hwan;Wee, Hyuk;Kim, Joong-Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.49-56
    • /
    • 2022
  • In this study, numerical simulations for reducing noise between floors in an apartment building was carried out using Active Noise Control (ANC) technology. In order to examine the feasibility of using ANC to reduce noise between floors, accelerometers and microphones for noise collection were installed in the inter-floor noise test facility to measure noise and vibration caused by the impact ball drop test. By using the measured data, Filtered-x Least Mean Square (Fx-LMS) algorithm-based ANC simulations were carried out. In the simulations, after deriving optimal simulation conditions including the adaptive control convergence coefficient, the noise reduction effect was analyzed through numerical simulations using the number of installed accelerometers and speakers as variables. Finally, it was confirmed that the noise between floors could be reduced using ANC technology under limited conditions.

An Evaluation of Flexural Strength of Hollow Concrete Filled FRP Tube Piles (중공형 콘크리트 충전 FRP Tube 말뚝의 휨강도 산정)

  • Kim, Hyung-Joon;Chung, Heung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.204-211
    • /
    • 2022
  • In this study, Hollow Concrete Filled FRP Tube Pile(HCFFT Pile) was proposed as a model to utilize the advantages of composite piles and solve the problem of corrosion, which is a disadvantage of CFT piles, and a numerical analysis model was developed to analyze their behavior. The strain compatibility method was applied considering the damage plastic behavior of concrete, the yield plastic behavior of steel, and the elastic behavior of FRP. The flexural strength calculation equation of HCFFT piles was proposed considering the change of the FRP tube section according to the distance from the neutral axis. The flexural strength calculation equation, numerical analysis results, and experimental results were compared and analyzed to verify their adequacy. The results of this study can be used as basic data for the optimal design of various HCFFT piles using FRP.

The Sensitivity Analysis of Urban Runoff Models to Variations of Pipe Roughness Coefficient (조도계수 변화에 따른 도시유출모형의 민감도 분석)

  • Won, Changyeon;Park, Jongpyo;Ko, Taekjo;Keum, Hojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.249-249
    • /
    • 2021
  • 도시지역의 우수유출해석 모형인 SWMM 모형의 매개변수는 유역유출관련 매개변수와 우수관로 매개변수로 구분이 된다. 이중 우수관로내 수리거동에 영향을 대표적인 매개변수는 조도계수가 있다. 우수관로 조도계수는 우수관로의 규격 및 재료에 따라 적용범위가 제시되어 있지만 현상태 관로내 퇴적 및 협잡물 등에 의한 조도변화가 발생하게 된다. 따라서 본 연구에서는 우수관로 조도계수의 변화에 따른 유량의 민감도를 검토하고 모니터링 유량과 비교를 통한 연구 대상지역의 최적 조도계수를 선정하였다. 연구 대상지역은 울산광역시 삼호동 일대이며 대상지역 내 발생한 우수유출은 최종적으로 태화강으로 방류되는 구조를 갖고 있는 배수분구이다. 조도계수 민감도 분석에 적용한 조도계수의 범위는 일반적인 원형 우수관로의 조도계수 0.013을 기준으로 하고 0.002씩 증감을 시켜 총 6개 CASE에 대한 민감도 분석을 수행하였다. 모의 유량의 비교군이 되는 관측 유량의 경우는 초음파 유량계로 관측한 총 3개 지점의 유량자료를 이용하여 민감도 분석에 활용하였다. 조도계수 민감도 분석결과 조도계수 증가에 따라 첨두유량은 감소하게 된다. 각 지점별 첨두유량 변화 폭은 지점 4, 5, 6에 각각 7.0% (-3.4~3.6%), 14.3% (-7.5~6.8%), 15.6% (-7.7~7.9%) 증감 폭을 갖는 것으로 분석되었으며, 유역의 하류부로 갈수록 변동 폭이 커지는 것으로 분석되었다. 시계열 수문곡선 비교결과 지점 4에서는 조도계수 0.011, 지점 5는 0.013, 지점 7은 0.015를 적용하는 것이 실측치와의 상관계수가 가장 높게 나타나는 것으로 분석되었다. 이상의 분석 결과를 토대로 유역의 관 흐름 상태의 변화는 관로의 퇴적, 부유물, 폐유부착 등의 유지관리 상태에 따라 달라지며 특히 유역의 하류부로 갈수록 퇴적, 부유물 등의 축척이 누적되어 조도계수를 상류부 보다 기준 값보다 크게 적용해야 관측치 유량과 유사하게 모의되는 것을 확인하였다. 따라서 도시유출해석 모형에서의 조도계수 적용은 우수관로의 유지관리 상태 등을 고려하여 우수관로별 적용 값 다르게 입력하는 것이 타당한 것으로 판단된다.

  • PDF