• 제목/요약/키워드: 최적용량 산정

검색결과 109건 처리시간 0.036초

직진교통의 좌회전차선 이용률 추정과 교차로용량 및 최적신호등시간 산정 (Estimating Utilization Factor of Left Turn Lane for Through Traffic, Intersection Capacity, and Optimum Signal Timings)

  • 도철웅
    • 대한교통학회지
    • /
    • 제1권1호
    • /
    • pp.56-63
    • /
    • 1983
  • Intersection control has dual-purposes; increasing capacity and reducing delay. The primary concern of efficient intersection control under oversaturated condition as in Korea is to increase capacity. Prevailing intersection operation technique permits thru traffic to utilize left turn lane, because the intersection without left turn pocket has left turn signal interval. In this situation, it seems not to be valid to calculate capacity, delay, and signal timings by conventional methods. By critical lane technique, capacity increases as cycle length increases. However, when thru traffic utilize LT lane, the capacity varies according to LT volume, LT interval as well as cycle length, which implies that specific cycle length and LT interval exist to maximize capacity for given LT volume. The study is designed is designed to calculate utilization factors of LT lane for thru traffic and capacities, and identify signal timings to yield maximum capacity. The experimental design involved has 3 variables; 1)LT volumes at each approach(20-300 vph), 2)cycle lengths (60-220 sec), and 3)LT intervals(2.6-42 sec) for one scenario of isolated intersection crossing two 6-lanes streets. For LT volume of 50-150 vph, capacity calculated by using the utilization factor is about 25% higher than that by critical lane method. The range of optimum cycle length to yield maximum capapcity for LT volume less than 120 vph is 140-180 sec, and increases as LT volume increases. The optimum LT interval to yield maximum capacity is longer than the intrval necessary to accommodate LT volume at saturation flow rate.

  • PDF

배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정 (The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System)

  • 장정태;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

REC 가중치를 고려한 최적 ESS 용량 산정에 관한 연구 (A Study on the Estimation of Optimal ESS Capacity Considering REC Weighting Scheme)

  • 이성우;김형태;신한솔;김태현;김욱
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1009-1018
    • /
    • 2018
  • As the generation of renewable energy increases rapidly, the stability of the grid due to its intermittency becomes a problem. The most appropriate way to solve this problem is to combine and operate the renewable generators with the ESS(Energy Storage System). However, since the revenues of operating the ESS are less than the investment cost, many countries are implementing various incentive policies for encouraging investment of the ESS. In this paper we estimated optimal capacity of the ESS to maximize profits of renewable energy generation businesses under the incentive policy of Korea and analyzed the impact of the incentive policy on the future electric power system of Jeju island. The simulation results show that the incentive policy has significantly improved the profitability of the renewable energy businesses generation business. But the volatility of the net demand has increased as the energy stored in the ESS is discharged intensively at the time of the incentive application.

PV-BESS 시스템의 적정 PCS, 배터리용량 산정에 따른 최적 운영에 관한 연구 (A Study on the Optimal Operation According to Appropriate PCS and Battery Capacity Estimation of PV-BESS System)

  • 최윤석;나승유
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1174-1180
    • /
    • 2018
  • In December 2017, the government announced plans to increase the current proportion of renewable energy from 7% to 20% by 2030 through a plan called the Renewable Energy 3020 Implementation Plan. Therefore, the demand for installation of photovoltaic(PV), wind turbine(WT) and battery energy storage system(BESS) is expected to increase. In particular, the system combined with energy storage system(ESS) is expected to take up a large portion since PV and WT can receive high renewable energy certificates(REC) weights when combined with ESS. In this study, we calculate the optimal capacity of the power conditioning system(PCS) and the BESS by comparing the economical efficiency and maximize the efficiency of the PV-BESS system in which the PV and the BESS are connected. By analyzing the system marginal price(SMP) and REC, it maximize profits through application of REC weight 5.0 and optimal charge-discharge scheduling according to the SMP changes.

울릉도 계통에 대한 플라이휠 최적 용량 산정에 관한 연구 (A Study on Optimal Flywheel Capacity Estimation for Ulleung-do Power System)

  • 최승원;이한상;이정필;한상철;성태현;한영희;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.606-607
    • /
    • 2007
  • This paper is about optimal flywheel capacity estimation for Ullueng-do power system. The power system of Ullueng-do has some differences with other island power system in Korea. It includes wind generator, hydro-generators as well as diesel generators. There are some problems on 600kW wind generator. Because of frequent drop of wind generator, the Ulleung-do power system have been threatened on frequency. The power frequency is 60Hz, and it should be between 59.9 and 60.1Hz. However, since the electrical inertia is small and the weight of wind generation is relatively high, generator drop of wind generation might make the power frequency out of boundary. In this paper, the flywheel energy storage system is assumed to be installed on Ulleung-do power system. Then, the maximum wind generation capacity and the optimal superconducting flywheel energy storage system capacity is estimated by the transient stability simulations.

  • PDF

단수피해 최소화를 위한 상수관망 내 최적 밸브위치 선정 (Determination of Optimal Valve Location in Water Distribution Networks)

  • 임갑율;강두선
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.108-108
    • /
    • 2018
  • 상수관의 노후화 혹은 공사 중 작업자의 실수, 또는 자연재해 등에 의해 상수관망 내 파손 관이 발생할 경우 파손된 관의 보수 및 교체 작업을 위해서는 파손 관과 인접한 밸브를 차폐하게 된다. 이로 인하여 관망의 일부 지역에 물 공급이 차단되는 단수구역이 발생하게 되며, 단수구역은 밸브를 닫음으로 인해 파손 관과 함께 격리되는 직접고립지역(segment)과 직접고립지역을 차폐함으로써 의도치 않게 수원으로부터 물 공급이 차단되는 간접고립지역(unintended isolation)으로 구분할 수 있다. 간접고립지역은 차폐된 직접고립지역으로 인해 수원으로부터의 유일한 용수공급 노선이 차단되어 발생한다. 관 파손에 의한 단수 피해를 현실적으로 모의하기 위해서는 밸브위치에 따른 단수구역을 정확히 산정할 필요가 있다. 단수구역은 파손관의 위치뿐만 아니라 차단 밸브의 개수 및 위치에 따라 달라진다. 따라서, 관 파손에 의한 단수피해를 최소화하기 위해서는 각 관로의 파손확률과 절점의 중요도를 고려하여, 적절한 밸브의 위치를 선정해야 한다. 본 연구에서는 관 파손에 따른 단수상황을 모의하여 파손 관에 의한 직, 간접 단수구역을 탐색한 후, 단수용량을 파악하고 이를 최소화하기 위한 밸브의 적정 위치를 최적화 알고리즘을 이용하여 결정하는 방안을 제시하였다.

  • PDF

지표면의 시공간적 변화를 고려한 비점오염원 저감 저류지 최적용량산정 (Optimal Volume Estimation for Non-point Source Control Retention Considering Spatio-Temporal Variation of Land Surface)

  • 최대규;김진관;이재관;김상단
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.9-18
    • /
    • 2011
  • In this study the optimal volume for non-point source control retention is estimated considering spatio-temporal variation of land surface. The 3-parameter mixed exponential probability density function is used to represent the statistical properties of rainfall events, and NRCS-CN method is applied as rainfall-runoff transformation. The catchment drainage area is divided into individual $30m{\times}30m$ cells, and runoff curve number is estimated at each cell. Using the derived probability density function theory, the stormwater probability density function at each cell is derived from the rainfall probability density function and NRCS-CN rainfall-runoff transformation. Considering the antecedent soil moisture condition at each cell and the spatial variation of CN value at the whole catchment drainage area, the ensemble stormwater capture curve is established to estimate the optimal volume for an non-point source control retention. The comparison between spatio-temporally varied land surface and constant land surface is presented as a case study for a urban drainage area.

유역변경방식에 의한 병렬저수지 시스템의 홍수조절효과 (Flood Control Effects by Water Transfer in Parallel Reservoirs)

  • 장광진;여운기;지홍기;이순탁
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.319-323
    • /
    • 2008
  • 본 연구는 인접한 저수지 간의 연계운영을 통해 홍수조절능력을 제고시키기 위한 저수용량 공유기법 개발의 일환으로서 안동댐과 임하댐의 병렬저수지 시스템을 연구대상유역으로 선정하였다. 홍수조절에 의한 병렬저수지의 연계운영기법으로서 홍수시 임하댐의 저수량을 안동댐으로 전환시켜 임하댐의 홍수조절능력을 제고시키고 안동댐의 저수량을 확보하여 용수공급능력을 제고시킬 수 있는 방법을 연구하였다. 임하댐의 유입량 중 안동댐으로 전환되는 유량비를 최적화계수 a로 두고 재현기간별로 유량전환비를 산정한 결과 최적화계수로 제안한 유량전환비 a는 재현기간 T=50년일 때 $a_{50}=0.310$, T=80년일 때 $a_{80}=0.185$, T=100년일 때 $a_{100}=0.130$, T=150년일 때 $a_{150}=0.035$로 산정되었으며, T=200년일때는 유량전환에 의한 홍수조절 효과가 없음을 알 수 있었다. 이러한 계산결과는 홍수규모가 클 경우에 안동댐 저수량(위) 증가로 인하여 임하댐의 유량전환비가 감소하기 때문임을 알 수 있었으며, 그 유량전환비가 거의 0이 될 경우는 홍수규모가 재현기간 T=200년 빈도 이상에서 나타나고 있음을 알 수 있었다. 이로 인한 홍수조절효과는 임하댐의 경우 재현기간 T=50년 일 때 4.1%, T=80년일 때 2.8%, T=100년일 때 2.1% 및 T=150년일 때 0.7%로 증가한 것으로 나타났으며, 안동댐의 경우 재현기간 T=50년일 때 14.4%, T=80년일 때 8.6%, T=100년일 때 6.0% 및 T=150년일 때 1.6%로 증가한 것으로 분석되었다.

  • PDF

장기유출모의를 통한 농업용저수지 저수율 예측 (Storage Rate Estimation of Irrigation Reservoir by Long term Rainfall-Runoff Modeling)

  • 박종표;정순찬;유창환;원창연
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.321-326
    • /
    • 2012
  • 장기유출모형을 이용하여 농업용저수지 유입량을 예측하고 농업용수 필요수량 및 홍수기 저수지 홍수조절을 통한 방류량 데이터를 이용하여 장기간에 대한 농업용저수지 저수율을 계산하였다. 계산결과와 실측 저수율 데이터의 비교 검증을 통하여 모형의 적용성을 평가하였다. 대상유역은 담양댐 지점이며 유역면적은 $47.2km^2$ 이며 주 하천 연장은 12.0km 이다. 담양댐은 저수용량에 비하여 유역면적이 작기 때문에 댐 계획 당시 순창군 구림면에 유역면적 $18.4km^2$ 인 2개의 보를 축조하여 유역변경방식으로 간접유역 유출량을 비관개기 및 홍수시에 도수하며 최대 도수량은 $10m^3/s$이다. 장기유출모의는 한국수자원공사(2001)에서 수행한 전역최적화기법인 콤플렉스 혼합진화기법을 통하여 추정된 나주지점의 모형보정 성과를 활용하였으며 모의기간은 1981-2010년(30년)이다. 장기유출모의 결과 담양댐 유역의 평균 유출율은 67% 인 것으로 분석되었다. 농업용수 필요수량은 한국농촌공사에서 산정한 연도별 필요수량 산정결과를 이용하여 실측 농업용수 월별 방류량 자료를 기준으로 관개개간인 4월 21일-9월 20일(163일)동안 월별로 분배하여 적용하였다. 홍수조절은 기존 댐 상시만수위, 홍수기제한수위 데이터를 근거로 운영하였다. 일별저수지 운영모형은 미공병단의 HEC-5 모형을 이용하였으며 한국농어촌공사 농촌용수종합 정보시스템(RAMIS)의 댐 일별 저수율 현황과 기존저수지 일별 저수지 모의운영결과를 비교 검증하였다. 모형수행결과 실측저수율과 모형수행결과의 상관계수는 0.93 인 것으로 분석되었다. 연구결과, 장기유출모의 결과와 연계하여 농업용수, 하천유지용수, 홍수조절을 고려한 저수지 운영을 통하여 비교적 정확하게 농업용저수지 저수율을 예측할 수 있을 것으로 판단된다. 본 연구성과를 바탕으로 농업용저수지의 장기적인 용수수급현황을 예측하여 효율적인 용수공급계획을 수립할 수 있을 것으로 기대된다.

  • PDF

기후변화 시나리오를 고려한 청미천 유역의 유지유량 공급량 결정 (Determination of water supply quantity for instreamflow requirement of the Cheongmicheon watershed considering climate change scenarios)

  • 송영훈;정은성;김수현
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.416-416
    • /
    • 2018
  • 본 연구는 과거자료와 기후변화 시나리오의 강수자료를 고려하여 유역 간 도수 사업의 용수공급량을 효과적으로 결정하는 방안을 제안하였다. 1985년 1월 ~ 2017년 6월까지 과거자료와 2011년부터 2100년까지의 RCP(Representative Concentration Pathway) 4.5 및 8.5 시나리오에 대해 각각 적용하였다. 청미천의 유량은 SWAT 모형을 이용하였는데 SUFI-2 알고리즘을 이용하여 최적 매개변수를 산정하였다. 본 연구는 도시 농촌 복합유역인 청미천 유역을 대상으로 하였으며 국토교통부가 고시한 원부교 지점의 하천 유지유량($0.96m^3/s$)의 연간 불만족일수를 분석하였다. 청미천 유역을 대상으로 현재 설치하고 있는 약 $30,000m^3$/일 규모의 용수 공급시설의 적용에 따른 불만족일수에 대하여 과거 강우자료를 이용하여 분석한 결과, 시설 적용 전 불만족 일수는 평균 54.94일/년이었고 적용 후에는 불만족일수가 평균 45.33일/년으로 10.61일/년이 감소하였다. 미래 기후변화 시나리오에 대해 분석하면 적용 전의 RCP 4.5의 평균 불만족일수는 65.99일/년이며 적용 후에는 11.82일/년이 감소한 54.17일/년으로 나타났다. RCP 8.5에서는 평균 불만족일수는 49.16일/년에서 39.16/년일 으로 10.0일/년이 감소하였다. 즉 현재 사업규모로는 하천유지유량 만족일수가 여전히 큰 것으로 나타났다. 따라서 본 연구에서는 기후변화 시나리오를 고려하여 최소최대후회도 접근법을 토대로 효과적인 유지 용수공급량을 결정하는 방법을 적용하였다. 단위 용수공급량이 증가할 때마다 늘어나는 불만족일수 감소량에 대해 연도별로 다른 값 중에 최댓값과의 차이를 후회도로 정의하고 용수공급량 별로 최대 후회도를 산정하였다. 이 중 최솟값을 나타내는 용량을 선택한 결과 RCP4.5는 $110,000m^3$/일, RCP8.5는 $90,000m^3$/일로 도출되었다.

  • PDF