• Title/Summary/Keyword: 최적용량 산정

Search Result 109, Processing Time 0.034 seconds

Estimation of the Optimal Generation Capacity of Solar-Wind Hybrid Power System for Economic Operations (태양광-풍력 복합발전시스템의 경제적 운용을 위한 최적 용량 산정에 관한 연구)

  • Lee, Seung-Chul;Moon, Un-Chul;Kwon, Byeong-Gook;Kim, Jong-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.156-162
    • /
    • 2004
  • In this paper, a technique that estimate the optimal capacity of the solar-wind hybrid power system for minimizing the total monthly electric power expenses is presented. The hybrid power system is assumed to be operated in connection with the utility power system and electric bill be paid for the power not covered by the hybrid system generation. Monthly generation cost is estimated based on total life-cycle cost analysis. The monthly utility power bill is assumed to be increased quadratically in proportion with the net utility power consumption which is the difference between the total monthly load minus the hybrid system generations. Test results demonstrate applications potential of the proposed technique.

The Program Coding Technology for the heat Load Prediction in Switching Room (통신시스템실 열부하 예측프로그래밍 기술)

  • Noh, H.K.
    • Electronics and Telecommunications Trends
    • /
    • v.14 no.5 s.59
    • /
    • pp.111-114
    • /
    • 1999
  • 전화국사 내 교환기의 신설이나 증설 시에 최적의 열부하 산정이 필요하다. 이를 위해 전화국사의 특성에 알맞은 열부하 계산 프로그램을 윈도우용으로 개발하여 비전문가들도 쉽게 사용할 수 있도록 하고자 한다. 프로그램 구성은 기본자료입력부, 전화국사의 자료입력부, 입력된 데이터를 이용하여 국사의 냉방부하와 냉방시스템의 용량을 계산하는 부분 그리고 출력부분으로 크게 4부분으로 나눌 수 있다. 본 프로그램을 이용하여 한국통신 중앙전화국 5ESS실의 냉방기기용량을 산정해 본 결과, 기존 냉방기기 69USRT의 49%에 해당되는 33.5USRT로 나타나 기존 냉방기기의 용량이 너무 과다하게 선정되었음이 판명되었다. 본 프로그램은 전화국사의 에너지 절약에 기여할 수 있을 것으로 판단된다.

Operation and Capacity Estimation of Stand-alone MCFC Power Generation System Including Rechargeable Battery (2차 전지를 포함한 독립운전형 MCFC 발전시스템의 운전 및 용량 산정)

  • Lee, Hee-Seo;Min, Kyung-Jin;Kim, Dong-Hee;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.252-253
    • /
    • 2010
  • 본 논문에서는 Molten Carbonate Fuel Cell (MCFC)의 느린 동특성을 Load Leveler와 2차 전지로 구성된 back-up 시스템으로 보완하여 독립운전을 가능하게 한 대용량 연료전지 발전시스템을 제안한다. 제안한 독립운전 시스템의 발전 용량 및 battery 용량은 실제 전력사용 통계자료를 근거로 최적으로 산정되며, 컴퓨터 시뮬레이션을 통하여 타당성을 검증한다.

  • PDF

Determination of Optimal Washland combination by Dynamic wave flood routing (동역학적 홍수추적을 통한 대규모 유역에서의 천변저류지 최적조합의 결정)

  • Park, Cheong-Hoon;Kim, Min-Seok;Oh, Byung-Hwa;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.292-296
    • /
    • 2010
  • 본 연구에서는 상대적으로 소규모 홍수저감시설인 천변저류지의 설치를 통하여 대규모 유역 하도 전체에서의 홍수위 저감효과를 평가하고 그 효율을 극대화 하는 방안을 제시하였다. 본 연구에 적용한 다목적 최적화 기법(Multi-objective Optimization)으로는 NSGA-II(Non-dominated Sorting Genetic Algorithm II) 알고리즘을 적용하였으며 천변저류지 설치에 따른 수위 영향구간 분석 및 유역 전체 하도구간에서 전반적으로 발생하는 수리, 수문학적인 변화 평가 및 천변저류지 최적 조합을 선정하기 위하여 천변저류지의 용량을 최소화하면서 하도 전 구간에서의 수위 저감량을 최대화할 수 있도록 최적화 알고리즘의 목적함수를 설정하였다. 천변저류지 설치에 따른 홍수량의 변화를 해석하기 위하여 안성천 유역에 대하여 동역학적 홍수추적을 수행하였으며 저류형 구조물의 설치에 따른 홍수량 저감효과 및 그에 따른 홍수위의 변화를 동시에 해석하기 위하여 UNET 모형을 기반으로 한 HEC-RAS 부정류 해석을 실시하였다. 천변저류지 조합별로 다양한 경우의 수가 존재하므로 HEC-RAS 구동 모듈인 HECRAS Controller를 Visual Basic으로 코딩된 최적화 알고리즘 프로그램과 연동함으로써 각 경우의 수별로 동역학적 홍수추적 및 부정류 해석을 실시함으로써 천변저류지 조합별 각 측점에서의 홍수량 및 홍수위를 산정하여 저류지 용량을 최소화하면서 각 하도 측점별 수위저감량을 최대화 하는 최적해 집단(Pareto Front)을 산정하여 제시하였다.

  • PDF

Estimation of Hardware Sizing in Korean EMS System (한국형 EMS 하드웨어 Sizing 산정에 관한 연구)

  • Lee, Won-Sang;Lee, Hyo-Sang;Yi, Myoung-Hee;Kim, In-Hyun;Lee, Bong-Gil;Choi, Jin-Woo;Yeo, Hyun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.412-413
    • /
    • 2007
  • 정보시스템의 개발 및 유지보수에 대한 기준은 과기처 등에서 제정한 'S/W 개발비 산정기준'을 준용하고 있다. 그러나 본 기준이 Business Computing 환경을 기준으로 작성되었고, 전력계통 제어를 비롯한 각종 공정제어시스템 구축 환경에 부적합할 뿐 아니라 시스템의 뼈대(Frame)를 구성하는 H/W의 규모 산정이 누락되어 있는 상태이다. 전력거래소는 우리나라의 전력계통 환경에 적합한 한국형 에너지관리시스템(이하 K-EMS)의 국산화 개발을 각종 첨단 S/W의 탑재 기준에 따라 단계별(Baseline, Prototype, Fullscale)로 추진하면서, 각 단계에 가장 적합한 하드웨어의 용량 산정 기준을 선정하는 작업을 진행하고 있다. 이는 정보시스템 개발에서 자원의 낭비를 최소화하고 전체 개발비용을 절감 할 수 있다는 점에서 매우 중요하다. 본 연구에서는 K-EMS 시스템 국산화 개발을 위해 K-EMS가 수용할 각종 응용프로그램별 특성을 감안한 하드웨어의 적정 용량 산정 기준과 적용방안을 제시하고, CPU, Memory 등 세부 항목에 대한 고려항목을 언급함으로써 최적의 K-EMS 하드웨어 Sizing 산정방안을 소개하고자 한다.

  • PDF

Efficient Information System Sizing Selection Using Cloud Computing Platform (클라우드 컴퓨팅 플랫폼을 이용한 효율적인 정보시스템 용량 산정 방법에 관한 연구)

  • Seong, Baek-min;Lee, Min-gyu;Sohn, Hyo-jung;Kim, Jong-bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.79-81
    • /
    • 2014
  • Recently, It is built various information systems evolve IT skills. But When you build the information system, Difficult to determine whether the appropriate scale and problems that rely heavily on SI companies and professionals. To solve this problem, Korea Information Security Agency, etc., based on the primary objective was to develop H/W Capacity Equation formally to each system type. But the problems are to present H/W capacity equation by discussion of the expert group of suppliers and relatively long that it is difficult to formally apply in the situation now so it is no longer the limit. In this study, we proposes proper capacity planning techniques, which can guarantee the best performance compared to the budget invested. For this purpose, we derived the proper H/W capacity equation by regression analysis to gather performance metrics and cost of various cases by simulation of a virtual environment in the cloud. Through this study, when capacity planning, It is possible to reduce costs that It is possible to build an information system based on the digitized data and build information system in an environment that does not rely on the SI business or professional.

  • PDF

Capacity Analysis of University Cloud Computer for Integrating Academic Affairs Business (대학 학사정보시스템의 클라우드 컴퓨팅을 위한 최적용량 분석)

  • Lee, Goo Yeon;Choi, Hwang Kyu;Choi, Chang Yeol;Jang, Min;Yoon, Jae Ku
    • Journal of Digital Contents Society
    • /
    • v.15 no.3
    • /
    • pp.413-423
    • /
    • 2014
  • Recently, cloud computing has been affecting academic information system buildup. When university academic affairs information system is designed with cloud computing, it is very important to estimate the adequate processing capacity for the cloud computer taking into account a waste of resources and the quality of service. Cloud computer's processing capacity to meet the quality of service expected by users should be predicted based on users' transaction patterns and resource requirements characteristics. In this paper, we analyze actual traffic patterns occurring in university academic affairs business and propose a method to calculate the optimal processing capacity for cloud computer to satisfy the given average response time. To justify our research, we apply the research results to a real university academic affairs business case and obtain the optimal processing capacity for the integrated academic affairs business.

도로터널의 환기시스템

  • Jo, Hyeong-Je;Baek, Jong-Hun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.40 no.4
    • /
    • pp.11-17
    • /
    • 2011
  • 적정한 환기용량의 산정과 최적의 환기방식선정으로 공사비를 절감하고, 운영 중의 안전성도 확보하는 방안을 소개하고자 한다.

  • PDF

통영 북만의 굴양식장 적정관리에 관한 연구 IV. 환경용량

  • 정우건;조창환;조상만;최우정
    • Proceedings of the Malacological Society of Korea Conference
    • /
    • 2001.11a
    • /
    • pp.37-38
    • /
    • 2001
  • 굴과 같은 이매패 양식장에서의 어장 환경 용량은 생물 서식환경의 질적, 양적 저하 없이 지속적으로 생산할 수 있는 생물의 양이라고 할 수 있다. 즉, 환경용량이란 환경의 악영향을 미치지 않으면서 지속적으로 최대 생산을 얻을수 있는 최대 생산을 오염부하 즉 자정 능력적 의미를 포함한다고 볼 수 있다. 연안 양식장은 대상해역에 따라 해수유동과 같은 물리적 특성, 해역이용 실태, 오염부하량 등 환경특성이 다양함으로 환경용량은 서로 다르다고 볼 수 있다. 이 연구에서는 통영시에 인접하여 도시하수의 영향으로 인하여 부영양화 되어 있다. 굴 양식이 행하여지는 북만을 대상으로 하여 양식 생물을 수용할 수 있는 환경용량을 생태유체역학 모델(藏本·中田,1991)을 이용하여 산정하고, 최적환경을 유지하기 위한 방안들을 검토하였다.

  • PDF

Optimal Var sizing and Allocation Considering Voltage Stability Margin (전압안정도 제약을 고려한 조상설비 최적투입계획)

  • Sung, Ung;Kim, Tae-Gyun;Lee, Byung-Jun;Song, Hwa-Chang;Kim, Tae-Gyun;Shin, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.95-96
    • /
    • 2008
  • 사회가 발전함에 따라 전력 수요는 기하급수적으로 증가한다. 늘어나는 전력 수요는 전압안정도 마진을 감소시키고 이는 대정전의 원인이 될 수도 있기 때문에 전력계통에서 전압유지 및 전압안정도 여유확보는 중요한 이슈가 된다. 무효전력은 전압과 큰 관련이 있기 때문에 전압유지 및 전압안정도 여유확보 방안으로써 가장 최우선적으로 고려되는 사항이 조상설비를 추가하는 것이다. 하지만 조상설비를 추가하기 위한 용지확보, 비용, 환경문제 등의 영향으로 인한 전원의 원격화, 편재화 그리고 부하의 수요집중화에 의한 송전설비의 장거리화와 대용량화가 진행되고 있으며 이와 같은 장거리 송전에 따라 계통손실의 증가와 수요지의 저전압문제가 발생하고 있다. 그러므로 전압안정도 마진을 고려하면서 조상설비를 적절하게 투입하는 것은 중요한 고려사항이다. 본 논문은 2007년 8월 EMS Peak 데이터를 시뮬레이션 해 조상설비를 투입함에 있어 최적의 위치와 용량을 산정하는 위한 방안을 제시한다. 이러한 조상설비 추가를 최소로 하는 경제적인 측면 뿐 아니라 전압 안정성 측면도 고려하기 위한 부하 scaling 기법을 적용해 전압안정도 여유를 확보하기 위한 방안을 추가한다. 또한 여러 가지 상정사고를 가정한 후 heuristic method를 적용해 조상설비 최적화를 수행하고 한전데이터를 근거로 추가할 조상설비의 가장 적절한 투입위치 및 용량을 산정해 제시한다.

  • PDF