• Title/Summary/Keyword: 최적설치 각도

Search Result 261, Processing Time 0.029 seconds

Verification of Optimum Degaussing Technique through the Mock-up Test of a Ship (축소 함정을 이용한 최적 소자기법 검증)

  • Kim, Dong-Wook;Choi, Nak-Sun;Kim, Dong-Hun;Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.107-113
    • /
    • 2014
  • In this paper, a optimum degaussing technique, which can minimize an underwater magnetic field anomaly generated by the ferromagnetic hull, was verified through the mock-up test of a ship. To predict degaussing field signals due to the degaussing coils installed in a ship, individual coil effects were measured. Exploiting the linearity of coil effects and analytical sensitivity formula, optimum degaussing current values fed to individual coils were decided. To identify degaussing performance of the proposed method, the obtained degaussing currents were applied to the coils. Then the field anomaly signals were measured and analyzed before and after degaussing. Experimental results show the magnitude of the field signal after degaussing is reduced up to 95% of that before degaussing.

Experimental Study of Wave-Absorbing Performance by Horizontal Punching Plates (수평형 타공판에 의한 소파성능의 실험적 연구)

  • Jung H. J.;Cho I. H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Wave absorbing system is needed at various kinds of wave basins (wave flume, towing tank, square tank) for the model test related to the ocean engineering. In this paper, the performance of wave absorbing system with new concept is estimated throughout the experiments. Herein, the wave absorbing system is designed by punching plate with a given porosity which is installed horizontally and submerged near the water surface. As the incident wave generated by a wave maker advances above a punching plate, the strong jet flow is formed near a hole of punching plate. As a result, wave energy is dissipated into heat energy, Systematic model tests were conducted at KRISO to verify the performance of the wave absorber using a punching plate. It was found that the reflection coefficient of wave absorber is deeply dependent on both the porosity and the submerged depth of a punching plate. Inclined installation of a punching plate shows better performance than a horizontal one within a certain inclined angle.

  • PDF

Developed of Smart Phone Charge System and Data Analysis for Efficient Solar Module Arrangement (효율적인 태양광 모듈 배치를 위한 데이터 분석 및 스마트폰 충전 시스템 개발)

  • Jang, Won-chang;Jeon, Min-ho;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2016
  • Recently, solar module is installed in crowded areas to offers services so that people can charge their smartphones or tablets. However, the burden in terms of cost is high to install in areas where utilization ratio is low and installation is difficult in limited spaces. In this paper, a system for collecting and providing the optical power is proposed from the analysis about the person that receives service in each area using the real-time data provided by the state and collected from the actual environment as well as considering the waiting time and the solar charging time in different environments. As a result, This study shows that charge was not delayed since collecting power exceeds charging power. Smartphone was fully charged in ninety-five minutes. we confirmed that with one smartphone, it can be charged a approximately fifty percent of the battery in between ten to twenty minutes, with multiple units they can be charged a approximately twenty percent of the battery in between ten to twenty minutes.

CFD Based Shape Design of Guide Vane for Fan Filter Unit (전산유체해석을 이용한 Fan Filter Unit(FFU)의 가이드 베인 형상설계)

  • Jang, Jun Hwan;Ahn, Joon;Myong, Hyon Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.709-716
    • /
    • 2013
  • A fan filter unit (FFU) is a device which supplies clean air from the ceiling in a clean room. With an increase in its size, velocity variation occurs within the exhaust plane and this damage the product quality or productivity. Hence, a guide vane is installed inside the device to enhance the velocity uniformity. Because the vane reduces the flow rate for a given pumping power, an optimum design is required to achieve velocity uniformity while minimizing the flow rate reduction at the same time. To find a geometry that satisfies these requirements, a series of numerical simulations has been conducted while changing the angle and length of the guide vanes. By changing the geometry of the side guide vane, the velocity uniformity increased by 3.7% and the flow rate decreased by 1.5%. For the center guide vane, the velocity uniformity increased by 2.9% and the flow rate decreased by 0.7%.

A Study of Coverage Extension and Minimum Deployment Cost in NBTC and WBTC Structures based WiBro System Using Multi-hop Relay (NBTC와 WBTC 구조를 갖는 WiBro 시스템에서 멀티홉 중계기를 이용한 커버리지 확장과 최소 설치비용 연구)

  • Kim, Se-Jin;Kim, Seung-Yeon;Lee, Byung-Bog;Ryu, Seung-Wan;Lee, Hyong-Woo;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10B
    • /
    • pp.911-918
    • /
    • 2008
  • In this paper, we propose new cell structures using multi-hop Relay Station(RS) based on IEEE802.16j in Narrow-Beam Trisector Cell (NBTC) and Wide-Beam Trisector Cell (WBTC), which are two methods for cell sectorization using 3-sector directional antennas. Then, we analyze our proposed structures compared with the existing system which does not use any RS about the numbers of optimized Base Station (BS) and multi-hop relay, the extended BS coverage, and the deployment cost according to the traffic density using optimization model. According to the results, we know the reduction of total deployment cost of the proposed systems and that WBTC is suitable when the traffic density is high and NBTC is suitable when the traffic density is low in our proposed multi-hop based NBTC and WBTC structures.

Study on Optimal Location of Water Quality Measurement Sensor Based on Travel Time (도달시간 기반 상수관망 수질계측기 최적위치 선정에 관한 연구)

  • Eun Hwan Lee;Jeong A Wang;Song I Lee;Hwan Don Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.497-497
    • /
    • 2023
  • 정수장에서 소독 및 여과 처리가 완료된 깨끗한 물은 배급수시설로 전달되나, 실제로 관의 노후화, 갑작스러운 유향 변동, 특정 구역의 관 내 정체 시간에 따른 Water Age 상승 등 여러 요인으로 인해 실제 수용가에는 안전하지 않은 용수가 공급될 가능성이 있으며, 이에 따라 적절한 위치에서 지속적인 감시를 통한 조기 발견 및 조치가 필요하다. 상수도 시설기준(2010)에 배수시설의 주요 지점 혹은 관 말단 등 필요에 따라 적절한 위치에 수질 계측기를 설치할 수 있도록 제시되어 있으나, 계측기 설치 위치나 개수에 대한 기준이 모호한 실정이다. 모든 구역에 수질계측기를 설치하여 감시하는 것이 이상적이지만, 현실적으로는 지자체 환경 및 경제적인 한계가 있어 주요 위치에 설치하는 것이 바람직하다. 본 연구에서는 대표적인 수리해석 모형인 EPANET을 사용하여 대상 관망의 노후도, 유속, 유향변동 등의 영향인자를 바탕으로 수질사고가 발생할 확률이 높은 관을 위험관으로 선정하고, 선정된 위험관을 대상으로 최단 경로와 Cost를 산출할 수 있는 Floyd Warshall Algorithm을 이용하여 각 Node(수용가)간 물이 이동할 때의 최소 도달시간과 경로를 파악하였다. 또한, 시간 서비스 수준(Level of T hour Serivice)의 개념을 도입하여 위험관으로부터 특정시간 이내에 흐름이 도달하는 Node를 파악한 뒤, 그 중 가장 많은 피해를 발생시킬 수 있는 위험관을 수질계측위치 지점으로 선정하였다. 제시된 수질사고 발생위험이 높은 위험관을 대상으로 수질계측 위치를 선정하는 방법이 전체 관망 네트워크를 대상으로 수질계측 위치를 판단하는 방법보다 결과 신뢰도 측면에서 더욱 효과적이고 효율적인 방법으로 사료된다.

  • PDF

Optimal Design of Datention System using Incremental Dynamic Programming (동적계획법을 이용한 유수체계의 최적설계)

  • 이길성;이범희
    • Water for future
    • /
    • v.28 no.1
    • /
    • pp.153-168
    • /
    • 1995
  • The purpose of this study is to develop an efficient model for the least cost design of multisite detention systems. The IDP (Incremental Dynamic Programming) model for optimal design is composed of two sub-models: hydrologic - hydraulic model and optimization model. The objective function of IDP is the sum of costs; acquisition cost of the land, construction cost of detention basin and pumping system. Model inputs include channel characteristics, hydrologic paramenters, design storm, and cost function. The model is applied to the Jung- Rang Cheon basin in Seoul, a watershed with detention basins in multiple branching channels. The application results show that the detention system can be designed reasonably for various conditions and the model can be applied to multi-site detention system design.

  • PDF

A Study on the Stabilizing Method against Landslide using Slide Suppressor Wall (산사태 억지벽체공법에 관한 연구)

  • Kim, Hong-Taek;Gang, In-Gyu;Yeom, Gyeong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.06c
    • /
    • pp.94-110
    • /
    • 1994
  • This paper Voposes a stabilizing method against landslide using slide suppressor wall reinforced with soil nails. Included are a Evuedlwe to predict earth Uessures acing on nailed-slide suppressor wall and a method of analysis of the laterally loaded concrete pile. Based rut the Voposed Vocedure, the emcignt installation type and inclusion angle of nails are analyzed. Also, optimum location of the slide suppressor wall composed of concrete panel and stabilizing pile is examined using the UC Vogram. Finally, an example is given to illustrate the analysis and desisa procedure of the proposed slope reinforcing method.

  • PDF

Numerical Simulation of Flows inside the Various Rooms for Performance Assessment of Air Cleaning System (공기청정 시스템 성능예측을 위한 실내 유동현상에 관한 수치모사)

  • 손덕영;이두환;길재흥;최윤호;김동현
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.306-316
    • /
    • 2002
  • ln this paper, flowfields inside the various rooms have been investigated. A storage room, a liv-ingroom with a kitchen in an apartment, and a hospital room are considered in the present calculations. In all cases, it was found that the average of air change rate is. similar to that of perfect mixing assumption and the location of air purifier has little effects on the average air change rate. Detailed local air concentrations show that there are regions where air is not quite purified because of non-uniform circulation of air flow. The location of air purifier has great effects on this behavior.

Excitation and System Identification of a Full-Scale Five-Story Structure for the Application of Viscoelastic Dampers (점탄성 감쇠기 적용을 위한 실물크기 5층 건물의 가진 및 시스템 식별)

  • 민경원;이상현;김진구;이영철;이승준;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • Excitation and system identification are carried out for a full-scale five-story structure to obtain fundamental data which will be used for the design of viscoelastic dampers, The hybrid mass driver(HMD) installed on the fifth floor was employed as external exciter to provide excitation for the building, Each floor response was measured and processed to find out where and how the viscoelastic dampers are located and designed. The sine-sweep and white noise loadings were applied to the structure by the HMD to obtain dynamic characteristics such as natural frequencies, damping ratios, and modes, The identified building was experimentally investigated again with the designed viscoelastic dampers installed at inter-stories to obtain the response behavior in the companion paper.