• Title/Summary/Keyword: 최저기준

Search Result 400, Processing Time 0.04 seconds

Studies on Adaptability by Rice Heading Ecology Type in the Central Northern Mid-Mountainous Cultivation Zone of Chungbuk Region (충북지역 중북부 중산간지 벼 출수생태형별 적응성 검토)

  • Lee, Chae Young;Choi, Ye Seul;Lee, Joung Kwan;Kim, Ik Jei;Kang, Shin Gu;Woo, Sun Hee;Kim, Young Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.3
    • /
    • pp.210-219
    • /
    • 2021
  • In recent years, air temperature has been increasing rapidly compared to the 1980s because of global warming. This increase in temperature reduces the yield and quality of rice; therefore, measures are needed to prevent such effects and ensure food security. The early maturing type (EMT) of rice is mainly cultivated in the central northern mid-mountainous area (CNMA). This study was conducted to shift the transplanting date of EMT and to examine the adaptability of the mid-maturing type (MMT) or mid-late maturing type (MLMT) in the Jecheon region of the CNMA to address global warming. The air temperature increased by 0.7-0.9℃ in the 2010s, compared to that in the 1980s, and was similar to other decades during the ripening period. Over the past 35 years, considering rice quality, the heading date of the Odae variety has arrived sooner by approximately 10 days, the ripened grain ratio has increased by more than 10%, and the thousand grain weight; however, the mean temperature at 40 days after heading has increased by more than 2℃. The late marginal heading date in the Jecheon region was determined as August 11 based on the accumulated temperature of 880℃ and August 15 based on 840℃ for 40 days after heading. According to different transplanting dates, milled rice yield per 10 a was the highest at 567 kg with June 10 in EMT, 595 kg with June 10 in MMT, and 572 kg with May 30 in MLMT. Considering the late marginal heading date, rice yield, and quality, the optimum transplanting date was June 15 in EMT, June 5 in MMT, and May 30 in MLMT in the Jecheon region of CNMA. Owing to global warming, MMT and MLMT are expected to be reliably cultivated in the CNMA.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

A Study on Physical and Mechanical Properties of Sawdustboards combined with Polypropylene Chip and Oriented Thread (폴리프로필렌사(絲)칩과 배향사(配向絲)를 결체(結締)한 톱밥보드의 물리적(物理的) 및 기계적(機械的) 성질(性質)에 관(關)한 연구(硏究))

  • Suh, Jin-Suk;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.1-41
    • /
    • 1988
  • For the purpose of utilizing the sawdust having poor combining properties as board raw material and resulting in dimensional instability of board, polypropylene chip (abbreviated below as PP chip) or oriented PP thread was combined with sawdust particle from white meranti(Shorea sp.). The PP chip was prepared from PP thread in length of 0.25, 0.5, 1.0 and 1.5 cm for conventional blending application. Thereafter, the PP chip cut as above was combined with the sawdust particle by 3, 6, 9, 12 and 15% on the weight basis of board. Oriented PP threads were aligned with spacing of 0.5, 1.0 and 1.5cm along transverse direction of board. The physical and mechanical properties on one, two and three layer boards manufactured with the above combining conditions were investigated. The conclusions obtained at this study were summarized as follows: 1. In thickness swelling, all one layer boards combined with PP chips showed lower values than control sawdustboard, and gradually clear decreasing tendendy with the increase of PP chip composition. Two layer board showed higher swelling value than one layer board, but the majority of boards lower values than control sawdustboard. All three layer boards showed lower swelling values than control sawdustboard. 2. In the PP chip and oriented thread combining board, the swelling values of boards combining 0.5cm spacing oriented thread with 1.0 or 1.5cm long PP chip in 12 and 15% by board weight were much lower than the lowest of one or three layer. 3. In specific gravity of 0.51, modulus of rupture of one layer board combined with 3% PP chip showed higher value than control sawdustboard. However, moduli of rupture of the boards with every PP chip composition did not exceed 80kgf/cm2, the low limit value of type 100 board, Korean Industrial Standard KS F 3104 Particleboards. Moduli of rupture of 6%, 1.5cm-long and 3% PP chip combined boards in specific gravity of 0.63 as well as PP chip combined board in specific gravity of 0.72 exceeded 80kgf/$cm^2$ on KS F 3104. Two layer boards combined with every PI' chip composition showed lower values than control sawdustboard and one layer board. Three layer boards combined with.1.5cm long PP chip in 3, 6 and 9% combination level showed higher values than control sawdustboard, and exceeded 80kgf/$cm^2$ on KS F 3104. 4. In modulus of rupture of PP thread oriented sawdustboard, 0.5cm spacing oriented board showed the highest value, and 1.0 and 1.5cm spacing oriented boards lower values than the 0.5cm. However, all PP thread oriented sawdustboards showed higher values than control saw-dustboard. 5. Moduli of rupture in the majority of PP chip and oriented thread combining boards were higher than 80kgf/$cm^2$ on KS F 3104. Moduli of rupture in the boards combining longer PP chip with narrower 0.5cm spacing oriented thread showed high values. In accordance with the spacing increase of oriented thread, moduli of rupture in the PP chip and oriented thread combining boards showed increasing tendency compared with oriented sawdustboard. 6. Moduli of elasticity in one, two and three layer boards were lower than those of control sawdustboard, however, moduli of elasticity of oriented sawdustboards with 0.5, 1.0 and 1.5cm spacing increased 20, 18 and 10% compared with control sawdustboard, respectively. 7. Moduli of elasticity in the majority of PP chip and oriented thread combining boards in 0.5, 1.0 and 1.5cm oriented spacing showed much higher values than control sawdustboard. On the whole, moduli of elasticity in the oriented boards combined with 9% or less combination level and 0.5cm or more length of PP chip showed higher values than oriented sawdustboard. The increasing effect on modulus of elasticity was shown by the PP chip composition in oriented board with narrow spacing. 8. Internal bond strengths of all one layer PP chip combined boards showed lower values than control sawdust board, however, the PP chip combined boards in specific gravity of 0.63 and 0.72 exceeded 1.5kgf/$cm^2$, the low limit value of type 100 board and 3kgf/$cm^2$, type 200 board on KS F 3104, respectively. And also most of all two, three layer-and oriented boards exceeded 3kgf/$cm^2$ on KS F. 9. In general, screw holding strength of one layer board combined with PP chip showed lower value than control sawdustboard, however, that of two or three layer board combined with PP chip did no decreased tendency, and even screw holding strength with the increase of PP chip composition. In the PP chip and oriented PP thread combining boards, most of the boards showed higher values than control sawdustboard in 9% or less PP chip composition.

  • PDF

Water Quality Level Model Using the Discriminant Analysis for the Small Streams of Rural Area in the Han River Watersheds (판별분석을 이용한 한강권역 농업용 하천수의 수질등급모형)

  • Choi, Chul-Mann;Lee, Jong-Sik;Cho, Nam-Jun;Ryu, Hui-Yong;Park, Seong-Jin;Kim, Jin-Ho;Yun, Sun-Gang;Lee, Jeong-Taek
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.2
    • /
    • pp.105-110
    • /
    • 2008
  • The main purpose of this work is the development of water quality level model using the data such as DO, EC, BOD, $COD_{Cr},\;NH_3-N,\;NO_3-N,\;PO_4-P$, T-N, T-P, and SS in 88 agricultural streams of the Han river watersheds. To grant water quality level for each parameters, it divided into 20% respectively in the order of water quality level. On the basis of the lowest water quality level, water quality of streams was assigned. As the result, number of stream corresponding to Level Ⅰ was 0, Level II was 1 stream, Level III was 3 streams, Level IV was 22 streams, and Level V was 62 streams. By standardized canonical discriminant function coefficient, $NO_3-N$ was the highest in 0.427 at the discriminant power. According to discriminant function for water quality level, it was equal to $-4.648+3.246{\times}[NO_3-N],\;-5.084+3.456{\times}[NO_3-N],\;-4.298+3.067{\times}[NO_3-N],\;and\;-7.369+4.396{\times}[NO_3-N]$ from Level II to Level V, respectively. As a result of test at real data of the Han river watersheds in 2007, the suitability of water quality level model was high to 88.4%.

Marine Algal Flora and Community Structure of Gogunsan Islands outside the Saemangeum Dike (새만금 방조제 외측 고군산군도 지역의 해조상 및 군집구조)

  • Kim, Ju-Hee;Ko, Yong-Deok;Kim, Young-Sik;Nam, Ki-Wan
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.2
    • /
    • pp.156-165
    • /
    • 2011
  • It is selected seven sites for marine algal flora and community structure and investigated seasonally from December 2008 to November 2009 in Gogunsan Islands, the west coast of Korea. A total of 58 species including 10 green, 16 brown and 32 red algae were collected and identified. Among these species, 11 species were found throughout the year. Annual mean biomass in dry weight were 213.8 g $m^{-2}$ at Sinsido 1, 143.1 g $m^{-2}$ at Sinsido 2, 133.3 g $m^{-2}$ at Sinsido 3, 164.0 g $m^{-2}$ at Munyeodo, 116.9 g $m^{-2}$ at Seonyudo, and 145.1 g $m^{-2}$ at Jangjado. Maximum biomass was recorded in Sinsido 1, and minimum mean biomass was Sinsido 4. The dominant species based on biomass were Sargassum thunbergii, Ulva pertusa, Sargassum fusiforme and Corallina pilulifera. S. thunbergii was the representative alga occurred at all seasons. The flora investigated could be classified into six functional groups such as coarsely branched form (46.6%), filamentous form (27.6%), sheet form (17.2%), thick leathery form (3.4%), jointed calcareous form (3.4%) and crustose form (1.7%). The R/P, C/P and (R+C)/P value reflecting flora characteristics were 0.33~0.75, 1.11~2.50, 1.47~3.25, respectively. Diversity index (H') and dominance index (DI) indicated that stability of seaweed community of Gogunsan Islands was unstable and environmental conditions were bad. According to multidimensional scaling (MDS) and cluster analysis, Gogunsan Islands were divided into three distinct groups. The first group was Sinsido 2, Sinsido 3, Seonyudo and Muyeodo and the second group comprised Sinsido 1 and Jangjado and the other was Sinsido 4 due to meaningful difference in similarity.

Cadmium Concentrations in Environmental Tobacco Smoke of Indoor Environments (실내환경의 환경성담배연기(ETS) 중 카드뮴에 관한 연구)

  • Ha, Kwon Chul;Park, Dong-Uk;Yoon, Chung Sik
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.299-308
    • /
    • 2003
  • The purpose of this study is to investigate cadmium concentrations among metals in ETS (Environmental Tobacco Smoke) of indoor environments and to evaluate the cadmium as a marker of ETS. The correlations of cadmium concentrations and nicotine, 3-EP, RSP, SD (Smoking Density), and SI (Smoking Index). Air samples of metals, nicotine, 3-EP, and RSP were taken in smoking room, smoking allowed office, corridor outside smoking room, and non-smoking office respectively. The SD, ACH, and SI were investigated during sampling. Airborne concentration of cadmium known as human carcinogen were qualified and quantified. The SD was 0.2 to $2.6cig/m^2{\cdot}hr$, and the mean value of SD in smoking rooms was $1.2cig/m^2{\cdot}hr$ that is higher than other researches. The mean of ACH in smoking rooms was 11.1. The concentrations of cadmium showed log-normal distributions and the geometric mean concentrations of cadmium in smoking rooms, corridor outside smoking rooms, smoking allowed offices, and non-smoking offices were $0.045{\mu}g/m^3$, $0.018{\mu}g/m^3$, $0.021{\mu}g/m^3$, and $0.017{\mu}g/m^3$ respectively. The concentrations of cadmium in smoking room showed significant difference according to category of indoor office environments (p<0.05) and showed compliance with occupational exposure limits. The correlation coefficients between cadmium and nicotine, 3-EP, and RSP were 0.53, 0.41, 0.43 respectively. The cadmium among metals showed the highest correlations (r=0.63) with SI. It was recommended cadmium among metals is a good indicator for ETS.

A Study on Long-term Variations of BOD and COD as Indicators of Organic Matter Pollution in the Han River (한강 본류에서 유기물 오염도 지표인 BOD와 COD에 대한 장기변동 특성)

  • Cho, Hyun-Seok;Kim, Kwang-Rae;Lim, Gyu-Chul;Bae, Kyung-Seok;Lee, Min-Hwan
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.4
    • /
    • pp.474-481
    • /
    • 2012
  • This study was performed to investigate the degree of long-term pollution at the mainstream of the Han River by comparing the concentration of BOD and COD from 1975 to 2011. The long-term annual average BOD and COD concentration at the mainstream of the Han River showed an increasing trend as it flowed downstream from Paldang Dam to Gayang. The concentration of BOD ($r^2$=0.646) and COD ($r^2$=0.260) showed a consistent decreasing trend for 37 years. In the case of Paldang Dam, BOD has maintained a decreasing trend, whereas the COD value showed an increasing trend after the 1990s. Therefore, a control of non-biodegradable materials in areas around Paldang Dam is required. The result of the seasonal variations of BOD and COD is as follows: spring>winter>summer and fall (p<0.001). The time series analysis revealed a strong correlation for every 12-month period. Also, the amount of water discharge at Paldang Dam has to be systematically controlled because the amount of water discharge from the dam influences the water quality at the mainstream of the Han River.

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.

Comparison of Growth Characteristics, Forage Productivity and Quality between Italian Ryegrass and Synthetics Derived from Interspecific and Intergeneric Hybrids and Ecotypes (이탈리안 라이그라스와 종.속간 잡종 및 생태형 유래 합성종간의 생육특성, 수량성 및 사료가치 비교)

  • Choi, G.J.;Lim, Y.W.;Lim, Y.C.;Sung, B.R.;Kim, M.J.;Kim, K.Y.;Park, G.J.;Kim, S.R.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.22 no.4
    • /
    • pp.265-272
    • /
    • 2002
  • Forage breeding laboratory of National Livestock Research Institute, R.D.A. has made interspecific hybrids of Lolium multiflorum $\times$ L. pratensis and intergeneric hybrids of Lolium $\times$ Festuca since 1984, and has collected ecotypes of Italian ryegrass since 1991. Growth characteristics of these hybrids and ecotypes were researched, and then these clone lines were named. Among these clone lines, the several clones that have polen fertility, high cold-tolerance, and similar heading time were used for making synthetics, Naehan 6, 7, 8, 9, with polycrossing method in 1997. Field experiments were carried out to compare the mophological and agronomical characteristics and forage productivity and quality of the synthetics with those of Italian ryegrass varieties, Barmultra and Hwasan 101. in Suwon and Yonchun from 1999 to 2000. Heading time of the synthetics were 22th to 24th May that belong to late-mature types to be similar to that of Barmultra and Hwasan 101 in Suwon. The synthetics were 101 to 106 c3n in plant length, medium or thick in thickness of stem, dark peen in leaf color, broad and long in flag leaf, strong in lodging resistance, and excellent in regrowth. Winter survivals of the synthetics were no different from that of Barmultra or Hwasan 101 in Suwon, but better than that of Barmultra or Hwasan 101 in Yonchun where was -10 to -12$^{\circ}C$ of minimum average air temperature in January or February. Dry matter(DM) yields of the synthetics were similar to DM 8,238kg per ha of Barmultra in Suwon, but in Yonchun, were more 7 to 13% than DM 7,291kg per ha of Barmultra. Forage qualities, IVDMD, ADF, NDF and TDN of the synthetics were lower than those of Hwasan 101, but higher than those of Barmultra.

A Study on Developing Web based Logistic Information System(KT-Logis) (웹 기반 통합물류정보시스템(KT-Logis) 개발에 관한 연구)

  • 오상호;김태준
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2001.11b
    • /
    • pp.125-141
    • /
    • 2001
  • In this paper, the current problems of logistics industry in Korea and their possible solutions were discussed. With Korea Telecoms KT-Logis, the supplier and demander of logistics service would not have to invest large sum of money into their computer system. All they need is just a computer with internet connected. What KT-Logis influence on the logistics industry are the following; 1. Many logistics service supplier and demander can do the business on the web with one computer system. 2. This web based computer system does not only work on the office but also apply on the field worker such as delivery personnel or even the forwarder with mobile phone. 3. KT-Logis is an integrated system which cover the broad arrange of logistics management from truck management to customer relations management. 4. Finally, KT-Logis is web based systems which suits for current e-business and mobile environment. In future, more studies should be done to develop more progressive integrated logistics information systems with enterprise resource planning(ERP) and supply chain management(SCM).

  • PDF