• Title/Summary/Keyword: 최소 침습적

Search Result 178, Processing Time 0.041 seconds

Conceptual framework for Emotions in Usability of Products (제품 사용성과 감성에 관한 개념적 연구)

  • Lee Kun-Pyo;Jeong Sang-Hoon
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2005
  • With the advent of computer technology, the fundamental nature of products has shaped from physical forms towards product interactivity, The focus is now on usability of the product with ease and efficiency rather than conversing with just the looks of the product. However, most definitions of usability and contemporary usability-related researches, have focused on the performance-oriented functional aspects of usability (i.e., how well users perform tasks using a product). Today, user expectations are higher; products that bring not only functional benefits but also emotional satisfaction. So far, there have been many studies on human emotions and the emotional side of products in the field of emotional engineering. Contemporary emotion-related researches have focused mainly on the relationship between product aesthetics and the emotional responses elicited by the products, but little is known about emotions elicited from using the products. The main objective of our research is analyzing user's emotional changes while using a product, to reveal the influence of usability on human emotions. In this research, we suggested conceptual framework for the study on the relationship between usability of products, and human emotions with emphasis on mobile phones. We also extracted emotional words for measuring user's emotions expressed not from looking at the product's appearance, but from using the product. First, we assembled a set of emotions that is sufficiently extensive to represent a general overview of the full repertoire of Korean emotions from the literature study. Secondly, we found emotional words in the after note by the users on the websites. Finally, verbal protocols in which the user says out loud what he/she ks feeling while he/she ks carrying out a task were collected. And then, the appropriateness of extracted emotional words was verified by the members of the consumer panel of a company through web survey. It is expected that emotional words extracted in this research will be used to measure user's emotional changes while using a product. Based on the conceptual framework suggested in this research, basic guidelines on interface design methods that reflect user's emotions will be illustrated.

  • PDF

Study of the enzymatic action of the chymopapain using pluronic based nano-carrier system on the cadaveric nucleus pulposus tissue (플루로닉(pluronic) 기반의 나노운반체(nano-carrier)에 충진된 카이모파파인(chymopapain)의 척추 추간판 조직내 작용성에 관한 연구)

  • Choi, Won Il;Tae, Gi Yoong;Hong, Young Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.585-592
    • /
    • 2015
  • The objective of this study is to determine if when chymopapain is loaded onto a nano-carrier, an injection of it reduces the spreading range of the drug within the discs. The materials for the experiment, which were conducted for three weeks, included fifteen intervertebral discs taken from two cadavers, which were divided according to the types of injected chymopapain solutions as follows: ordinary chymopapain group and nano-carrier system group. The nano-carrier system group was again divided into two subgroups according to the types of pluronics, the basic material for the nano-carriers: Pluronic F 127(DA-PF 127) in the nano-carrier group and Pluronic F 68(DA-PF 68) in the nano-carrier group. The results showed that the action of chymopapain using a pluronic-based nano-carrier system was localized around the center of the injection site instead of broad spreading, compared to that of the ordinary chymopapain group (p<0.01). This characteristic suggests a possible application to effective agents for minimally invasive spinal treatment through which disc lesions were removed selectively.

The Effect of Indwelling Silk Suture Material Following Aspiration in the Treatment of Chronic Prepatellar Bursitis (흡인 후 견 봉합사 거치를 통한 만성 슬개골전 점액낭염의 치료)

  • Lee, Bong-Jin;Lee, Sung-Rak;Kim, Chung-Hyun;Kim, Seong-Tae
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.55-59
    • /
    • 2005
  • Purpose: To evaluate the drainage effect of silk suture material following aspiration of the bursa as an early treatment of chronic prepatellar bursitis. Materials and Methods: Twelve cases, which have over two weeks of history and over one year of follow-up, were investigated. The average duration of follow-up was 18.3 months. The average symptom duration before introduction into this study was 2.2 months. With an aseptic technique, the aspiration of the bursa was done with spinal needle or injection needle and syringe and then the insertion of silk suture material through the aspiration needle was performed. Over one year follow-up, recurrence, infection, pain, and limitation of range of motion were investigated by telephone interview. Results: Redness around the insertion site of silk suture material was found in all cases, but there was no development of active infection in eleven cases. At five days after procedure, a supprative infection was developed in one case. The results were considered satisfactory in 92% of cases and the average duration of treatment is 14.5 days. Conclusion: The drainage with silk suture material following aspiration of the bursa is effective and less invasive method in the early treatment of chronic prepatellar bursitis.

  • PDF

Implant placement simultaneously sinus augmentation using crestal approach in severely atrophic maxilla; minimally invasive approach (골 흡수가 심한 상악 구치부에서 치조정 접근법을 이용하여 상악동 골이식술 동시 임플란트 식립)

  • Kim, Hyun-Joo;Kwon, Eun-Young;Choi, Jeomil;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.1
    • /
    • pp.47-54
    • /
    • 2017
  • The atrophy of edentulous ridge and pneumatization of the maxillary sinus often limit the volume of bone available for implant placement on maxillary posterior teeth. Most clinicians suffer difficulties from poor bone quality and quantity on maxillary posterior site. Thus, the success of maxillary posterior implant surgery depends on the increase of the available bone and obtaining a good initial stability of the implant after maxillary sinus reconstruction. The maxillary sinus augmentation methods include a crestal approach and a lateral approach. Less morbidity and complications after operation is major advantage to sinus augmentation using crestal approach than lateral approach. However, when the residual ridge height is ${\geq}6mm$, it is known that crestal approach is appropriate. Also delayed implantation after sinus augmentation is recommended in severely atrophic ridge. We present the three cases of implant placement simultaneously sinus augmentation using crestal approach in posterior maxilla site with ${\leq}3mm$ of residual alveolar bone.

Intramedullary Nailing versus Minimally Invasive Plate Osteosynthesis for Distal Tibia Shaft Fractures: Retrospective Comparison of Functional and Cosmetic Outcomes (경골 원위간부 골절 치료의 골수강내 금속정 고정술과 최소침습 금속판 고정술의 비교: 기능적, 미용적 결과의 후향적 비교)

  • Kahyun Kim;In Hee Kim;Geon Jung Kim;SungJoon Lim;Ji Young Yoon;Jong Won Kim;Yong Min Kim
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.3
    • /
    • pp.93-98
    • /
    • 2023
  • Purpose: This study compared the functional and cosmetic treatment outcomes of intramedullary nailing (IM nail) and minimally invasive plate osteosynthesis (MIPO) for distal tibia shaft fractures. Materials and Methods: Forty-eight patients with distal tibia shaft fractures (distal 1/3 of the diaphysis, AO/OTA [AO Foundation/Orthopaedic Trauma Association]) 43 managed by an IM nail (n=30) or MIPO (n=18) who had minimum one-year follow-up were enrolled in this study. The radiological, functional, and cosmetic outcomes in the two groups were compared retrospectively. Results: All patients achieved bone union. The mean bone union time of the IM nail and MIPO groups was 18.5 and 22.6 weeks, respectively (p=0.078). One patient in the MIPO group showed posterior angulation and valgus deformity of more than five degrees. The mean American Orthopaedic Foot and Ankle Society (AOFAS) functional scores were similar: 83.3 in the IM nail group and 84.6 in the MIPO group (p=0.289). The most salient difference was the cosmetic result of the surgical scar. The length of the scars around the ankle in the IM nail group was significantly smaller than the MIPO group (2.6 cm vs. 10.6 cm; p=0.035). The patient satisfaction survey of surgical scars revealed a significantly higher satisfaction rate in the IM nail group than in the MIPO group (93% vs. 44%; p<0.001). Conclusion: This study showed that both treatment methods for distal tibia shaft fractures have similar therapeutic efficacy regarding the radiological and functional outcomes. On the other hand, the IM nail technique showed superior cosmetic outcomes than the MIPO technique. IM nails may be more recommended in patients with high demand for cosmetic results.

Ventilator-Associated Pneumonia in Neonatal Intensive Care Unit : Clinical Manifestations, Ddiagnostic Availability of Endotracheal Tip Culture (신생아 집중치료실에서 인공 환기요법 관련 폐렴의 임상양상과 기관내 삽관의 유용성에 관한 연구)

  • Kim, Nam Young;Sung, Tae Jung;Shin, Seon Hee;Kim, Sung Koo;Lee, Kon Hee;Yoon, Hae Sun
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • Purpose : The incidence of mortality associated with respiratory difficulties is decreasing nowadays contributed to the development of neonatology. However, complications associated with mechanical ventilator are increasing. This study is to determine clinical manifestations, diagnositc availability of the endotracheal tip culture in patients with Ventilator-Associated Pneumonia(VAP) in neonatal intensive care unit(NICU). Methods : A retrospective analysis of 50 neonates who were admitted to the NICU of Kangnam Sacred Heart Hospital and had given mechanical ventilator from 1 January 2000 to 30 June 2003. VAP group defined as neonates who had pneumonia with mechanical ventilation longer than 48 hours. They were classified into VAP group(n=13) and control group (n=37) and the prevalence, microorganisms cultured from the endotracheal tube tip and risk factors were investigated. Results : The prevalence of VAP was 26.0%(n=13) and the most dominant microorganism cultured in our NICU was methicillin-resistant coagulase negative staphylococcus(MR-CNS) in 4 cases. Other microorganisms were Pseudomonas, Enterobacter, methicillin-resistant Staphylococcus aureus(MRSA) and Klebsiella. Gestational age, birth weight, Apgar score, respiratory distress syndrome, retinopathy of prematurity, bronchopulmonary dysplasia, sepsis, renal failure, pulmonary hemorrhage, pneumothorax were not different significantly between two groups except intraventricular hemorrhage(P<0.001) and patent ductus arteriosus(P<0.05). Duration of hospital stay and mortality rate were also not different significantly. Conclusion : VAP occurred at a significant rate among mechanically ventilated NICU patients. Despite of limitation of encotracheal tip culture, the most common microorganism was MR-CNS. We should be aware of occurrence of VAP in NICU neonate who were with mechanical ventilator and should treat with great care.

  • PDF

Usefulness of the quantitative analysis by using the functional parameter index from dynamic salivary glands scintigraphy (동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성)

  • Shin, Chae Ho;Kim, Bong Su;Cho, Yong Gyi;Jo, Jin Woo;JIn, Sung Eun;Pyo, Sung Jai
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose This study was to evaluate the usefulness through the comparison of patients group and healthy control group by acquiring a variety of functional parameters index from time-activity curves of salivary gland scintigraphy using $^{99m}Tc$. Materials and Methods From December 2014 to February 2015 with the targets of 30 patients in the patient group who presented themselves with xerostomia and underwent the salivary gland scan and 10 people in healthy control group, approximately 30 minutes of dynamic Scan was carried out after the intravenous bolus injection of 370 MBq of $^{99m}TcO_4{^-}$ and per os stimulation with Vitamin C powder 20 minutes after the injection. The method of quantitative analysis was as follows, the time-activity curve was drawn after the parotid gland and submandible gland were prescribed as a region of interest, a variety of functional parameters index was obtained in each position of the curve, and the patients group and the control group were compared. Results As for the methods applied in comparison and measurement, uptake ratio (UR), time at maximum counts (Tmax), time at minimum counts (Tmin), maximum accumulation (MA), accumulation velocity, maximum secretion (MS), maximum stimulation secretion (MSS), and secretion velocity (SV) were used. In the comparison of functional parameters index of patient group and normal group, the healthy normal group showed significant difference compared to the patient group in all indices except for the minimum radioactivity time (Tmin), and also in terms of variation over time the normal group showed significant difference compared to the patient group (p<0.05). Conclusion Consequently, it was considered that the quantitative analysis that used a variety of functional parameters index would be useful for evaluating the function of the salivary glands of the patients with xerostomia as an objective and standardized information.

  • PDF

Influence of Heat Treatment Conditions on Temperature Control Parameter ((t1) for Shape Memory Alloy (SMA) Actuator in Nucleoplasty (수핵성형술용 형상기억합금(SMA) 액추에이터 와이어의 열처리 조건 변화가 온도제어 파라미터(t1)에 미치는 영향)

  • Oh, Dong-Joon;Kim, Cheol-Woong;Yang, Young-Gyu;Kim, Tae-Young;Kim, Jay-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.619-628
    • /
    • 2010
  • Shape Memory Alloy (SMA) has recently received attention in developing implantable surgical equipments and it is expected to lead the future medical device market by adequately imitating surgeons' flexible and delicate hand movement. However, SMA actuators have not been used widely because of their nonlinear behavior called hysteresis, which makes their control difficult. Hence, we propose a parameter, $t_1$, which is necessary for temperature control, by analyzing the open-loop step response between current and temperature and by comparing it with the values of linear differential equations. $t_1$ is a pole of the transfer function in the invariant linear model in which the input and output are current and temperature, respectively; hence, $t_1$ is found to be related to the state variable used for temperature control. When considering the parameter under heat treatment conditions, $T_{max}$ was found to assume the lowest value, and $t_1$ was irrelevant to the heat treatment.

Clinical Results of Surgical Treatment with Minimally Invasive Percutaneous Plate Osteosynthesis for Displaced Intra-articular Fractures of Calcaneus (최소침습적 금속판 내고정술을 이용한 전위된 관절 내 종골 골절의 임상적 치료결과)

  • Suh, Jae Wan;Yang, Jong Heon;Park, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.87-93
    • /
    • 2020
  • Purpose: This study evaluated the clinical results of surgical treatment with minimally invasive plate osteosynthesis for treating displaced intra-articular fractures of the calcaneus in comparison with conventional lateral extensile approach plate osteosynthesis. Materials and Methods: Of 79 cases of Sanders type II or III calcaneus fractures, 15 cases treated with the minimally invasive calcaneal plate (group M) and 64 cases treated with lateral extensile approach calcaneal plate (group E) were identified. After successful propensity score matching considering age, sex, diabetes mellitus history, and Sanders type (1:3 ratio), 15 cases (group M) and 45 cases (group E) were matched and the demographic, radiologic, and clinical outcomes were compared between the two groups. Results: The median time of surgery from injury was 2.0 days in group M and 6.0 days in group E (p=0.014). At the six months follow-up, group M showed results comparable with those of group E in radiographic outcomes. In the clinical outcomes, group M showed better postoperative American Orthopaedic Foot and Ankle Society (AOFAS) and visual analogue scale (VAS) scores than did group E (p=0.001, p=0.008). A greater range of subtalar motion was achieved at the six months follow-up in group M (inversion 20.0° vs. 10.0°, p=0.002; eversion 10.0° vs. 5.0°, p=0.025). Although there were no significant differences in complications between the two groups (1 [6.7%] vs. 7 [15.6%], group M vs. group E; p=0.661), there was only one sural nerve injury and no wound dehiscence and deep infection in group M. Conclusion: Minimally invasive plate osteosynthesis showed superior clinical outcomes compared with that of the conventional lateral extensile approach plate osteosynthesis in Sanders type II or III calcaneus fractures. We suggest applying minimally invasive plate osteosynthesis in Sanders type II or III calcaneus fractures.

Practical Considerations of Arterial Spin Labeling MRI for Measuring the Multi-slice Perfusion in the Human Brain (스핀 라벨링 자기공명영상을 이용한 사람 뇌에서의 뇌 관류영상의 현실적 문제점을 향상 시키는 방법 연구)

  • Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • In this work practical considerations of a pulsed arterial spin labeling MRI are presented to reliable multi-slice perfusion measurements In the human brain. Three parameters were considered in this study. First, In order to improve slice profile and Inversion efficiency of a labeling pulse a high power Inversion pulse of adiabatic hyperbolic secant was designed. A $900^{\circ}$ rotation of the flip angle was provided to make a good slice profile and excellent Inversion efficiency. Second, to minimize contributions of a residual magnetization be4ween Interleaved scans of control and labeling we tested three different conditions which were applied 1) only saturation pulses, 2) only spotter gradients, and 3) combinations of saturation pulses and spotter gradients Applications of bo4h saturation pulses and spoiler gradients minimized the residual magnetization. Finally, to find a minimum gap between a tagged plane and an imaging plane we tested signal changes of the subtracted image between control and labeled Images with varying the gap. The optimum gap was about 20mm. In conclusion, In order to obtain high quality of perfusion Images In human brain It Is Important to use optimum parameters. Before routinely using In clinical studios, we recommend to make optimizations of sequence parameters.

  • PDF