• Title/Summary/Keyword: 최소품질표준

Search Result 26, Processing Time 0.023 seconds

The Economic Effects of Minimum Quality Standards and Mutual Recognition Agreements (선진국의 최소품질표준 설정과 국가 간 상호인정협정 체결의 효과 분석)

  • Han-Eol Ryu
    • Korea Trade Review
    • /
    • v.48 no.3
    • /
    • pp.107-130
    • /
    • 2023
  • This study examines the economic effects of a developed country's minimum quality standards (MQS) and mutual recognition agreements (MRAs) between countries. Based on the results of such analysis, it also considers the optimal MRA strategy for South Korea. For this purpose, the paper constructs a simple three-country model in which the representative firms in each country supply differentiated goods to the developed country market. The analysis results are as follows: First, the rise in the MQS of a developed country intensifies the competition level, reduces the profits of all firms, and raises the developed country's consumer surplus. In addition, if one of the firms exits the market due to the MQS, competition is relaxed, and the profits of the remaining firms increase. Second, countries subject to MQS can improve their social welfare through the MRAs; thus, it is essential to utilize them strategically. In the case of South Korea, the optimal situation is to have an MRA with the developed country or for all three countries not to have any MRA.

Feature Extraction Algorithms for Evaluation of the Geometrical Tolerences (기하공차의 평가를 위한 형상추출 알고리즘)

  • 김승우
    • Journal of the KSME
    • /
    • v.34 no.3
    • /
    • pp.177-184
    • /
    • 1994
  • 이 글에서는 기하공차의 기본적인 개념들에 대한 설명과 삼차원측정기 응용소프트웨어에서 기하 공차를 평가하기 위한 수학적인 방법들에 대해 소개하였다. 최소영역법은 ISO규격에 의한 공차 평가법이란 점에서 근래의 연구의 대부분을 차지하고 있으나 표준적인 알고리즘이라 할 수 있는 방법은 아직 발표되지 않고 있으며 실용적인 소프트웨어의 경우 최소자승법을 근간으로 하고 있는 실정이다. 최근에는 이러한 형상추출과 기하공차평가를 포함하는 좌표식 측정기 술(coordinate metrology)이 컴퓨터통합생산(computer integrated manufacturing)시스템 구축에 있어서 아킬레스건이라 할 수 있는 컴퓨터원용검사(computer aided quality control)의 핵심적인 기술로 인식되어 선진국에서는 이미 표준기술을 확립하고자 하는 목적으로 체계적인 지원하에 연구를 수행하고 있다. 그러므로 국내에서도 품질보증에 의한 제조업 분야의 생산성 제고를 위 하여 좌표식 측정기술에 대한 연구와 투자가 시급하며 국내의 표준기술 확립이 절실히 요청되고 있다하겠다.

  • PDF

Estimation of Kinetic Parameters of Nonenzymatic Browning Reaction Using Equivalent Time at Reference Temperarture with Linearly Increasing Temperature Profile (정속가열(定速加熱)조건에서 표준온도상당시간(相當時間)을 이용한 비효소적 갈색화 반응의 동력학 파라미터 추정(推定))

  • Cho, Hyung-Yong;Kwon, Yun-Joong;Kim, In-Kyu;Pyun, Yu-Ruamg
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.178-184
    • /
    • 1993
  • The procedure using equivalent time at reference temperature has been assessed for the estimation of kinetic parameters with experimental data. Kinetic studies of nonenzymatic browning reaction in model and food system were carried out with linearly increasing temperature method. These kinetic parameters, n, $k_{ref}$ and $E_a$ of the systems were evaluated from original data in one step by nonlinear least square regression. The one step procedure yielded efficiently accurate parameter estimation. Computer simulated data with the kinetic models were well consistent with experimental data (average correlation coefficient=0.96).

  • PDF

A Weighted Mean Squared Error Approach to Multiple Response Surface Optimization (다중반응표면 최적화를 위한 가중평균제곱오차)

  • Jeong, In-Jun;Cho, Hyun-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.625-633
    • /
    • 2013
  • Multiple response surface optimization (MRSO) aims at finding a setting of input variables which simultaneously optimizes multiple responses. The minimization of mean squared error (MSE), which consists of the squared bias and variance terms, is an effective way to consider the location and dispersion effects of the responses in MRSO. This approach basically assumes that both the terms have an equal weight. However, they need to be weighted differently depending on a problem situation, for example, in case that they are not of the same importance. This paper proposes to use the weighted MSE (WMSE) criterion instead of the MSE criterion in MRSO to consider an unequal weight situation.

Evaluation of the Quality of Records of the Serials Union Catalog Database (연속간행물 종합목록 데이터베이스의 레코드 품질 평가)

  • Yoon, Cheong-Ok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.37 no.1
    • /
    • pp.27-42
    • /
    • 2003
  • The purpose of this study is to evaluate the quality of the Serials Union Catalog(UCAT) of KISTI. In examining both MARC records and bibliographic display records of 172 Japanese serials, AACR2R and KORMARC formats were used as the standard rules. Those records were described in the minimum or incomplete level ; but had repeated errors in various data fields, which included the incorrect choice of main headings, parallel titles and other titles, the improper use of language codes and related data fields, and the provision of incomplete information, etc. To improve the overall quality of bibliographic database, thorough comprehension and application of cataloging rules and MARC formats are strongly required.

Nutrient Balance For The Laying Hen (산란계를 위한 영양소의 균형)

  • ;J. M. Vandepopuliere
    • Korean Journal of Poultry Science
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1981
  • 급격히 증가하는 세계의 인구수는 가축의 사료자원을 질이 좋은 인간 식량으로 효율적으로 전환할 필요성을 절실케 하고 있다. 산란계는 유전적인 선택에 의해 최소량의 사료로써 높은 산란율을 유지할 수 있도록 개선되어 왔다. 배합사료의 생산에 사용될 수 있는 단미사료의 종류와 품질은 어느 특정한 영양소의 요구량에 의하여 좌우된다. 산란계의 영양요구량은 오랜동안 연구되어 왔으며, 미국의 국립연구위원회 (NRC)는 영양소 요구량을 정기적으로 검토, 요약하고 있다. 새로운 정보들은 출판되어 왔으며 본인은 여기서 제7차로 개정된 NRC 사양표준(1977)에 발표된 요구량에 관련해서 몇 가지 분야를 검토하고자 한다. (중략)

  • PDF

Effects of Non-drainage Hydroponic Culture on Growth, Yield, Quality and Root Environments of Muskmelon (Cucumis melo L.) (멜론 수경재배 시 배액제로화가 근권환경 및 수량에 미치는 영향)

  • Chang, Young Ho;Hwang, Yeon Hyeon;An, Chul Geon;Yoon, Hae Suk;An, Jae Uk;Lim, Chae Shin;Shon, Gil Man
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2012
  • This study was conducted to figure out the possibility of non-drainage in muskmelon (Cucumis melo L.) hydroponics culture. Plants were grown under 3 different levels of drainage, standard (20~40%, SD), minimum (5~10%, MD), and non-drainage (ND). Throughout cultivation periods, constant water content and electrolyte conductivity changes in root zone were observed in SD in the range of 60~70% and $1.5{\sim}2.5dS{\cdot}m^{-1}$, respectively. ND treatment caused the fluctuation in water content and electrolyte conductivity of root zone and its change ranges were 30~50% in water content and $2{\sim}6dS{\cdot}m^{-1}$ in electrolyte conductivity, but ND treatment did not decrease fruit quality. Even if fruit fresh weight was slightly lower in ND with 1,863 g, than in SD with 1,990 g, the fruit weight in ND meets standard market size, 1,800~2,000 g. Higher soluble solids content was observed in fruit in ND than in SD and MD. Total amount of drainage per plant was 27,718, 15,769 and 2,346 mL in SD, MD and ND, respectively. SD showed $83.2m^3$ drainage, 34.5% drainage of irrigation amount whereas required total irrigation amount in ND was very low with $7m^3$.

Frequency Distribution Characteristics of Formation Density Derived from Log and Core Data throughout the Southern Korean Peninsula (남한지역 검층밀도 자료의 특성 분석)

  • Kim, Yeonghwa;Kim, Ki Hwan;Kim, Jongman;Hwang, Se Ho
    • The Journal of Engineering Geology
    • /
    • v.25 no.2
    • /
    • pp.281-290
    • /
    • 2015
  • Log density data were collected and compared with the core density data throughout the southern Korean Peninsula. The comparison reveals that the log densities obtained from gamma-gamma log are much lower than the core densities obtained from laboratory density measurement of core samples. The anomalously low log densities can be attributed to the small-source density log data. Correlation analysis reveals differences between densities derived from the two methods, indicating that a data quality problem arises when using small-source log data. The problem is probably due to the fact that small-source data have not been obtained under ideal conditions for maintaining the appropriate relationship between gamma response and formation density. The frequency distribution characteristics of formation density in the southern Korean Peninsula could be determined using the core and the standard-source log data which are well-correlated.

Trend of 3GPP UTRA-UTRAN LTE and SAE Standardization (3GPP UTRA-UTRAN LTE 및 SAE 표준화 동향)

  • Lee, B.J.;Shin, Y.S.
    • Electronics and Telecommunications Trends
    • /
    • v.21 no.3 s.99
    • /
    • pp.23-35
    • /
    • 2006
  • 3GPP는 HSPA와 같은 라디오 액세스 기술의 개선을 바탕으로 다가오는 수 년 동안 높은 경쟁력을 가질 것으로 예측된다. 그러나 3GPP에서는 급속히 발전되는 정보통신서비스를 효율적으로 제공하기 위해, 3GPP R6 기술과 비교하여 사용자와 사업자의 비용을 줄이면서도 고품질의 다양한 서비스를 제공하는 새로운 이동통신기술의 필요성을 인식하고, 낮은 전송 지연(low latency), 높은 전송률(high data rate), 시스템 용량과 커버리지를 개선하는 3G long term evolution 표준기술 작성을 시작하였다. 이에 따라 지난 2004년 말부터 3GPP에 참여한 사업자, 벤더, 연구소 등은 2007년 6월 표준규격작성완료를 목표로 LTE와 SAE에 대한 연구를 진행해 오고 있다. 이들 연구는 상호 운용성을 제공하기 위한 기술적 솔루션을 최소로 하면서 불필요하게 중복되는 필수 특성들을 줄이고 다양한 액세스 네트워크 사이에서 모빌리티를 제공하는 것을 목적으로 하고 있다. 본 문서에서는 2006년 3월까지 진행된 3GPP의 표준화 및 기술 동향에 대해살펴본다.

Quality Control of Radiation Counting Systems and Measurement of Minimum Delectable Activity (방사선 계측기의 품질관리 및 최소검출방사능 측정)

  • 송병철;한성심;김영복;지광용;손세철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.419-424
    • /
    • 2004
  • Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the $\gamma$-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 Ops within $2{\sigma}$ confidence levels. The average alpha background level for the low background ${\alpha}{\beta}$ counting system was 0.31 cpm and the efficiency for alpha counting was 34.38%. The average beta background level for the ${\alpha}{\beta}$ counting system was 1,30 cpm and the efficiency for beta counting was 46.5%, The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the$\gamma$-spectrometer was found to be 3.2 Bq/$m\ell$ and 3.8 Bq/$m\ell$ for the liquid scintillation counter, and 20.5 and 23.0 Bq/$m\ell$, respectively for the $\alpha$ and $\beta$ counting system.

  • PDF