• Title/Summary/Keyword: 최소침습

Search Result 217, Processing Time 0.025 seconds

Minimally Invasive Laser-Assisted Biopsy of the Oral Lesions for Oral Graft-Versus-Host Disease after Hematopoietic Stem-Cell Transplantation (조혈줄기세포이식후 발생한 이식편대숙주병의 구강병소에 대한 최소침습적 레이저조직생검 증례)

  • Kim, Yun-Mi;Yun, Hee-Jung;Kim, Hyun-Sil;Kim, Kee-Deog;Jung, Bock-Young;Pang, Nan-Sim;Park, Won-Se
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.3
    • /
    • pp.147-154
    • /
    • 2012
  • Hematopoietic stem-cell transplantation (HSCT) is a treatment for immune deficiency, autoimmune diseases, and hematopoietic malignancies. The main complication of allogenic HSCT is graft-versus-host disease (GVHD). Oral mucosal biopsy is needed for a definitive diagnosis and treatment planning of GVHD, but this procedure causes bleeding and bacteremia in a poor general condition. We evaluated the efficacy of laser-assisted biopsy as a minimally invasive treatment. Three cases were described in this article. All patients' medical records, clinical photographs, and histopathologic findings were reviewed. All patients felt comfortable and no severe complications occurred. The quality of the obtained biopsy material was adequate for a definitive diagnosis of GVHD. Laser-assisted, minimally invasive biopsy of the oral mucosa does not cause bleeding, and it reduces the chances of infection, bacteremia, and postoperative scarring compared to the usual histopathologic biopsy procedure. It would thus be advantageous to use this procedure to biopsy GVHD patients.

A Comparison between Minimally Invasive Percutaneous Plate Osteosynthesis and Plate Fixation in the Treatment of Clavicle Midshaft Fracture (쇄골 간부 골절의 최소 침습적 경피적 금속판 고정술과 관혈적 수술 비교)

  • Yoo, Seong-Ho;Kang, Suk-Woong;Kim, Bu-Hwan;Song, Moo-Ho;Kim, Yeong-Joon;Park, Gyu-Taek;Kwack, Chang-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Purpose: To retrospectively compare minimally invasive percutaneous plate osteosynthesis (MIPPO) with open plate fixation for the treatment of clavicle midshaft fracture. Materials and Methods: Between November 2011 to May 2014, 40 cases that were followed for more than 1 year-among all cases of MIPPO and open plate fixation-were analyzed. The study population was divided into two groups: group A included 20 cases of MIPPO and group B included 20 open plate fixation cases. The comparative analysis between the two groups was based on the operative time, bone union, functional evaluation (American Shoulder and Elbow Society score), incision length, pain relief (visual analogue scale, VAS), and complication. Results: The bone union was successful for all the cases, and the functional evaluation scores of the shoulder joint were satisfactory for both groups (p>0.05). The operative time was 47.5 minutes and 58.7 minutes for group A and B, respectively (p<0.05). The incision length for group A was 6.2 cm and that for group B was 10.7 cm with statistical significance (p<0.05). Pain relief (VAS) after surgery for group A showed a quick recuperation in the early stages. For complications, there were 2 cases of dysesthesia and 1 case of malunion due to metal fixation failure in group A. There were 6 cases of dysesthesia and 2 cases of cosmetic problem due to hypertrophic scar in group B. Conclusion: Surgical results of clavicle shaft fracture were satisfactory for both groups, but group A had advantages of shorter operative time, minimal incision length, and better pain relief in the early stages compared with group B. However, we need further evaluations with long-term follow-up results and complications, such as malunion and exposure on radiation.

Anatomic Concerns about Hip Arthroscopy (고관절 관절경을 위한 해부학적 관점)

  • Kim, S.J.;Oh, Kwang-Jun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.79-87
    • /
    • 2010
  • 고관절경을 시행하는 집도의사는 관절경을 통해 관찰되는 정상 고관절의 해부학적 구조물에 대한 정확한 지식과 삽입구 위치에 대한 숙지를 통해 환자의 증상과 비정상 관절경 소견을 임상적으로 연관 시키는 것이 중요하며, 적절한 환자의 선택과 고관절경의 술기에 대한 항상성을 유지할 수 있어야 최소 침습적인 술기의 장점을 가지고 있는 고관절경의 만족할 만한 치료 결과를 기대할 수 있다.

  • PDF

Physiological Measurement based on Optics (광학기술을 이용한 생리상태 측정)

  • 윤길원;이종연;박건국;전계진;김홍식;이정환
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.250-251
    • /
    • 2003
  • 광학기술의 의학적 응용은 1900년 루비레이저가 개발되고 이어서 다양한 레이저가 개발되면서부터다. 레이저를 이용하면서 최소침습적 수술이 가능해졌고, 내시경을 사용하여 체내 부분에 대한 시술도 가능해졌다. 최근에는 레이저, 발광다이오드, 램프 같은 광원을 소스로 하고 광검출기를 센서로 하는 광학 기술을 이용한 생리상태 측정에 대한 연구가 진행되고 있다.

  • PDF

Minimal Invasive cardiac Surgery ; Small Submammary Incision (유방하 횡절개를 이용한 최소침습 심장수술)

  • 정승혁;신용철;임용택;김병일;이정호
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.96-98
    • /
    • 2000
  • A cosmetic incision for minimal invasive cardiac surgery is described. Through a small submammary skin incision combined with partial low sternotomy some kinds of cardiac operations are possible without extra-difficulty but with excellent cosmetic effect, No special instruments nor techniques are required. By this method routine cannulations for cardiopulmonary bypass as well as aortic cross clamping bicaval snaring and venting of cardiac chambers are possible, We performed 5 cases of open heart surgeries using this approach which includes two cases of atrial septal defect closure one case of ventricular septal defect closure one case of pulmonic valvotomy and one case of mitral valve replacement.

  • PDF

Real-time Bleeding Animation for Virtual Surgery Medical Simulation (가상 수술 의료 시뮬레이션을 위한 실시간 출혈 애니메이션 기법)

  • Lee, Jeong-Jin;Seo, Che-Hwan;Lee, Ho;Kye, Hee-Won;Lee, Min-Sun
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.5
    • /
    • pp.664-671
    • /
    • 2012
  • Recently, practice education using virtual medical simulation has been applied to real clinical environment by enhancing the learning efficiency. Specially, in minimally invasive surgery, the necessity of virtual surgery medical simulation has been increased. Realistic bleeding animation, which represents bleeding special effects frequently occurred in virtual medical simulation environment, has not been proposed yet. In this paper, we propose realistic real-time bleeding animation. For bleeding simulation, proposed method calculates main and effective bleeding regions along the main bleeding direction vector to represent naturalistic bleeding effect. In addition, for bleeding rendering, proposed method uses sigmoid function to impose weights of vertex opacities for the smooth opacity change so that the results of bleeding animation is realistic. Proposed method improves the sense of the real and absorption in virtual surgery medical simulation so that the education efficiency of doctors and students using medical simulation can be enhanced.

Cauterizing Effect Animation for Virtual Surgery Medical Simulation (가상 수술 의료 시뮬레이션을 위한 소작 효과 애니메이션 기법)

  • Lee, Jeong-Jin;Lee, Ho;Kye, Hee-Won
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.9
    • /
    • pp.1175-1181
    • /
    • 2011
  • Practice education using virtual medical simulation has been recently introduced to maximize the learning efficiency in clinical environment. Specially, in minimally invasive surgery, the necessity of virtual surgery medical simulation has been substantially increased. Since cauterizing effect occurred frequently in minimally invasive surgery has been represented by simple bleeding, realistic cauterizing effect animation has not been proposed yet. In this paper, we propose realistic real-time cauterizing effect animation. Proposed method changes the individual element of each vertex color of the mesh and uses sigmoid function to impose weights for the smooth color change inside the valid mesh region so that the results of cauterizing effect animation was realistic. In addition, by proposing cauterizing color buffer, overlapped cauterizing effects can be realistically represented. Proposed method greatly improves the sense of the real and absorption in virtual surgery medical simulation so that the education efficiency of doctors and students using medical simulation can be maximized.

Thoracoscopic Aortic Valve Replacement assisted with AESOP (Automated Endoscope System for Optimal Positioning) 3000 (AESOP 3000을 이용한 흉강경적 대동맥 판막 치환술)

  • Shin Hong Ju;Kim Hee Jung;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.507-509
    • /
    • 2005
  • Open heart surgery via right thoracotomy can be accomplished in atrial septal defects, and mitral valve diseases. Recently, thoracoscopic atrial septal defect closure, mitral valve repair, Maze operation, and minimal invasive direct coronary artery bypass (MIDCAB) are accomplished with AESOP 3000. However, there is no report of thoracoscopic aortic valve replacement in Korea. We report a successful thoracospic aortic valve replacement assisted with AESOP 3000 in a 31-year-old female patient.