• Title/Summary/Keyword: 최소자승

Search Result 1,179, Processing Time 0.034 seconds

A Study on the Efficiency and Determinants of Static and Dynamic in Korean property casualty insurance Company (국내 손해보험회사의 효율성 및 결정요인에 대한 Static and Dynamic 분석)

  • Kim, Tae-Hyuk;Park, Chun-Gwang;Kim, Byeong-Chul
    • The Korean Journal of Financial Management
    • /
    • v.25 no.4
    • /
    • pp.183-212
    • /
    • 2008
  • The purpose of this paper is to analyze the efficiency change and determinants of the korean non-life insurance companies. we use DEA (Data Envelopment Analysis) model to measure company efficiency change and use GLS, Tobit model, FIixed effect model, Random effect model, GMM to measure efficiency determinants. we utilize ten non-life insurance companies in korea and the panel data for five from 2001 to 2005. The empirical results show the following findings. First, technical efficiency shows that approximately 15.5% of inefficiency exists on the non-life insurance companies and it reveals that the cause for technical inefficiency is due to scale inefficiency. Second, Dea Window results show that the stable dissimilarity by standard deviation, LDP of CCR. Third, the results of efficiency determinants show that increase efficiency is depend on the premium income and real estates.

  • PDF

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$

Induction of the High Order Calibration Equation of Metal Oxide Semiconductor Gas Sensors (산화물 반도체식 가스센서의 입출력 고차 캘리브레이션 방정식 도출)

  • Park, Gyoutae;Kim, Kangmin;Lee, Hyeonggi;Yoon, Myeongsub
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.44-49
    • /
    • 2020
  • In this paper, a measuring circuit is designed through analyzing manufacture specification of the sensor based on MOS. And the best input-output polynomial are induced that really gas sensors are used in gas safety management industrial fields. Response characteristics of a MOS gas sensor is analysed by through sensor's output voltages are measured after standard gases with six kinds of concentrations are manufactured and are injected to the sensor. A lookup table is created by relations of sensor's output voltages by injecting gases with other concentrations. Because data of the formed lookup table are equal interval, a polynomial can be induced of method of approximation function. So the 5th polynomial of input-output for a sensor is defined, coefficients are calculated by using least squares method, and the 5th polynomial is completed for representing characteristics of the sensor. If the proposed polynomial is applied to gas leak detectors, an inverse transformation of polynomial and programing of array codes are recreated. In this research, polynomial is implemented with array types that intervals of values of a lookup table are one-fifth sampled and interpolated. The performance of proposed 5th calibration equation is verified that errors are reduced than a linear expression when tests are performed by measurement of concentrations against injection of standard gases.

Simultaneous Spectrophotometric Determination of Copper, Nickel, and Zinc Using 1-(2-Thiazolylazo)-2-Naphthol in the Presence of Triton X-100 Using Chemometric Methods (화학계량학적 방법을 사용한 Triton X-100이 함유된 1-(2-Thiazolylazo)-2-Naphthol을 사용한 구리, 니켈과 아연의 동시 분광광도법적 정량)

  • Low, Kah Hin;Zain, Sharifuddin Md.;Abas, Mhd. Radzi;Misran, Misni;Mohd, Mustafa Ali
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.717-726
    • /
    • 2009
  • Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ in synthetic mixture and tap water.

Crystal Structure of a Bromine Sorption Complex of Dehydrated Calcium and silver Exchanged Zeolite A (칼슘 및 은 이온으로 치환된 제올라이트 A를 탈수한 후 브롬을 흡착한 결정구조)

  • Bae, Myung-Nam;Kim, Un-Sik;Kim, Yang
    • Korean Journal of Crystallography
    • /
    • v.8 no.2
    • /
    • pp.127-131
    • /
    • 1997
  • The crystal structure of a bromine sorption complex of vacuum-dehydrated Ag+ and Ca2+ exchanged zeolite A(a=12,234(1) Å) has been determined by single-crystal X-ray diffraction methods in the cubic space group Pm3m. The crystal was prepared by flow method using exchange solution in which mole ratio of AgNo3 and Ca(NO3)2 was 1:150 with a total concentration of 0.05M. The crystal was dehydrated at 360℃ and 2 ×10-6 Torr for 2days, followed by exposure to 180 Torr of Br2 vapor for 20min. full-matrix least-squares refinements converged to the final error indices of R1=0.111 and R2=0.101 using 90 reflections for which I>3o(I). About 3.1 Ag+ ions and 4.45 Ca2+ ions lie on the two crystallographically nonequivalent three-fold axes associated with 6-ring oxygens. A total of six bromine molecules are sorbed per unit cell. Each bromine molecule approaches a framework oxide ions axially (Br-Br-O=171(2)', O-Br=3.25(6) Å; and Br-Br=2,61(8) Å by a charge-transfer interaction.

  • PDF

A Method for Evaluation of Mechanical Accuracy of a Teletherapy Machine Using Beam Directions (방사선 진행방향을 이용한 원격치료장치의 기계적 정확성 평가방법)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.53-64
    • /
    • 1996
  • Purpose: The purposes of this paper are to develop a theoretical basis that the beam directions should be considered when the mechanical accuracy of teletherapy machine is evaluated by the star pattern test, to develop methods using asymmetric field in length to simulate beam direction for the case that beam direction does not appear on film. Method: In evaluating mechanical rotational accuracy of the gantry of teletherapy unit by the star pattern test, the direction of radiation beams was considered. A star pattern using some narrow beams was made. Density profiles at 10cm far from estimated gantry axis on the star pattern were measured using an optical densitometer. On each profile, one coordimate of a beam axis was determined. A pair of coordinates on a beam axis form an equation of the axis. Assume that a unit vector equation omitted is with same direction as radiation beam and a vector equation omitted is a vector directing to the beam axis from the estimated gantry axis. Then, a vector product equation omitted ${\times}$ equation omitted is an area vector of which the absolute value is equal to the distance from the estimated gantry axis to the beam axis. The coordinate of gantry axis was obtained by using least-square method for the area vectors relative to the average of whole area vectors. For the axis, the maximum of absolute value of area vectors would be an accuracy of the gantry rotation axis. For the evaluation of mechanical accuracies of collimator and couch axes for which beam direction could not be depicted on a star pattern test film, narrow beams asymmetric in field length was used to simulate beam direction. Result: For a star test pattern to evaluate the mechanical accuracy of rotational axes of a telectherapy machine, the result considering beam direction was different from that ignoring beam direction. For the evaluation of mechanical accuracies of collimator and couch axes by means of a star pattern test, narrow asymmetric beams could simulate beam direction. Conclusion: When a star pattern test is used to evaluate the mechanical accuracy of a teletherapy unit, beam direction must be considered or simulated, and quantitatively evaluated.

  • PDF

Estimation of Fatigue Crack Initiation Life Distribution by Multi-notched Specimen (다응력집중부(多應力集中部)를 가진 판(判)에 의(依)한 피로균열(疲勞龜裂) 발생수명(發生壽命) 분포(分布) 추정(推定))

  • S.W. Kang;D.S. Uom;J.H. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.4
    • /
    • pp.234-243
    • /
    • 1992
  • Fatigue crack initiation life has a wide scatter and this makes the fatigue design of structural members difficult. In order to make the fatigue life distribution clear, it is required to prepare a large number of specimens and repeat the fatigue tests under the same loading condition. Such fatigue tests usually take much time and cost. In this study, a fatigue testing method using a multi-notched test specimen for the purpose of estimating the distribution function of fatigue crack initiation life by small number of fatigue tests is used. The purpose of this study is to verify the above fatigue testing method of a multi-notched specimen by using Bayesian reliability analysis, Least square method and Skewness method for the determination of unknown Weibull parameters. The multi-notched specimen is a specimen in which several tens of statistically identical notches are prepared.

  • PDF

A LQR Controller Design for Performance Optimization of Medium Scale Commercial Aircraft Turbofan Engine (II) (중형항공기용 터보팬 엔진의 성능최적화를 위한 LQR 제어기 설계 (II))

  • 공창덕;기자영
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.3
    • /
    • pp.99-106
    • /
    • 1998
  • The performance of the turbofan engine, a medium scale civil aircraft which has been developing in Rep. of Korea, was analyzed and the control scheme for optimization the performance was studied. The dynamic and real-time linear simulation was performed in the previous study The result was that the fuel scedule of the step increase overshoot the limit temperature(3105 $^{\cire}R$) of the high pressure turbine and got small surge margine of the high pressure compressor. Therefore a control scheme such as the LQR(Linear Quadratic Regulator) was applied to optimizing the performance in this studies. The linear model was expected for designing controller and the real time linear model was developed to be closed to nonlinear simulation results. The system matrices were derived from sampling operating points in the scheduled range and then the least square method was applied to the interpolation between these sampling points, where each element of matrices was a function of the rotor speed. The control variables were the fuel flow and the low pressure compressor bleed air. The controlled linear model eliminated the inlet temperature overshoot of the high pressure turbine and obtained maximum surge margins within 0.55. The SFC was stabilized in the range of 0.355 to 0.43.

  • PDF

Measurement of Glucose and Protein in Urine Using Absorption Spectroscopy Under the Influence of Other Substances (타 성분 영향을 고려한 요당과 요단백의 흡수분광학 진단)

  • Yoon, Gil-Won;Kim, Hye-Jeong
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.346-353
    • /
    • 2009
  • Glucose and protein in urine are among the important substances for urine analysis and have generally been measured based on a reagent strip test. In this study, these two substances were measured using mid-infrared absorption spectroscopy. Samples were prepared from a commercial synthetic urine product. Glucose and albumin were added as well as red blood cells, which are expected to create the most spectroscopic interference of any substance. Concentrations of these substances were varied independently. Optimal wavelength regions were determined from a partial least squares regression analysis (glucose 980 - 1150/cm, albumin 1400 - 1570/cm). Interference by other substances increased the differences between measured and predicted values. Albumin measurement in particular weres heavily influenced by the presence of glucose and red blood cells. Depending on the inference by other substances, measurement errors were 29.85${\sim}$45.19 mg/dl for a glucose level between 0 and 1000 mg/dl and 14.0${\sim}$93.11 mg/dl for an albumin level of 0 ${\sim}$ 500 mg/dl. Our study proposes an alternative to the chemical test-strip analysis, which shows only discrete concentration levels.

Localization Using Extended Kalman Filter based on Chirp Spread Spectrum Ranging (확장 Kalman 필터를 적용한 첩 신호 대역확산 거리 측정 기반의 위치추정시스템)

  • Bae, Byoung-Chul;Nam, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.45-54
    • /
    • 2012
  • Location-based services with GPS positioning technology as a key technology, but recognizing the current location through satellite communication is not possible in an indoor location-aware technology, low-power short-range communication is primarily made of the study. Especially, as Chirp Spread Spectrum(CSS) based location-aware approach for low-power physical layer IEEE802.15.4a is selected as a standard, Ranging distance estimation techniques and data transfer speed enhancements have been more developed. It is known that the distance measured by CSS ranging has quite a lot of noise as well as its bias. However, the noise problem can be adjusted by modeling the non-zero mean noise value by a scaling factor which corresponds to the change of magnitude of a measured distance vector. In this paper, we propose a localization system using the CSS signal to measure distance for a mobile node taken a measurement of the exact coordinates. By applying the extended kalman filter and least mean squares method, the localization system is faster, more stable. Finally, we evaluate the reliability and accuracy of the proposed algorithm's performance by the experiment for the realization of localization system.