• Title/Summary/Keyword: 최소기준

Search Result 1,578, Processing Time 0.028 seconds

Effect of Seleniferous Whole Crop Barley Silage on Growth Performance, Blood and Carcass Characteristics, and Tissue Selenium Deposition in Finishing Hanwoo Steers (셀레늄 강화 청보리 사일리지 급여가 비육기 거세한우의 생산성, 혈액성상 및 도체특성과 조직 내 셀레늄 축적에 미치는 영향)

  • Hwangbo, Soon;Jo, Ik Hwan;Kim, Guk Won;Choi, Chang Weon;Lee, Sung Hoon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.4
    • /
    • pp.281-289
    • /
    • 2013
  • This study was conducted to investigate the effects of feeding seleniferous whole crop barley silage (WCBS) on the growth performance, blood and carcass characteristics, and tissue selenium deposition infinishing Hanwoo steers. A total of 20 growing Hanwoo steers were selected and assigned to one of the following feed groups: control (0.1 ppm Se), T1 (0.3 ppm Se), T2 (0.9 ppm Se), and T3 (0.9 ppm of inorganic Se). Five steers were allocated to each treatment group, and the trial lasted for 90 days. All experimental diets combined seleniferous and/or non-seleniferous WCBS up to a ratio of 30%. For the T3 diet, 0.9 ppm Se in the form of sodium selenite was added to the control diet. Dietary level and type of selenium did not affect feed intake and body weight gain. Blood total lipid and triglyceride concentrations were significantly (p<0.05) lower in the T2 group than in control. Blood immunoglobulin G concentration increased significantly (p<0.05) with increasing levels of dietary selenium; concentrations were significantly (p<0.05) higher in T2 and T3 than in control. Blood selenium concentration was the highest (p<0.05) in T2. No significant difference was observed in dressing rate, ribeye area, marbling score, meat color and fat color. Further, no association was found between levels and chemical form of dietary selenium and quality and quantity of meat. To the contrary, tissue selenium content in kidney, liver, and hind leg increased significantly (p<0.05) with increasing levels of selenium; however, feeding inorganic selenium did not introduce a significant increase in tissue selenium content of finishing Hanwoo steers. The results indicated that the selenium present in seleniferous WCBS was an effectively absorbable selenium source, suitable for increasing tissue selenium content in beef. Approximately 100 g of hind leg muscle from steers fed on the T2 diet met approximately 69% of the recommended daily selenium requirements.

Risk Ranking Analysis for the City-Gas Pipelines in the Underground Laying Facilities (지하매설물 중 도시가스 지하배관에 대한 위험성 서열화 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.54-66
    • /
    • 2004
  • In this article, we are to suggest the hazard-assessing method for the underground pipelines, and find out the pipeline-maintenance schemes of high efficiency in cost. Three kinds of methods are applied in order to refer to the approaching methods of listing the hazards for the underground pipelines: the first is RBI(Risk Based Inspection), which firstly assess the effect of the neighboring population, the dimension, thickness of pipe, and working time. It enables us to estimate quantitatively the risk exposure. The second is the scoring system which is based on the environmental factors of the buried pipelines. Last we quantify the frequency of the releases using the present THOMAS' theory. In this work, as a result of assessing the hazard of it using SPC scheme, the hazard score related to how the gas pipelines erodes indicate the numbers from 30 to 70, which means that the assessing criteria define well the relative hazards of actual pipelines. Therefore. even if one pipeline region is relatively low score, it can have the high frequency of leakage due to its longer length. The acceptable limit of the release frequency of pipeline shows 2.50E-2 to 1.00E-l/yr, from which we must take the appropriate actions to have the consequence to be less than the acceptable region. The prediction of total frequency using regression analysis shows the limit operating time of pipeline is the range of 11 to 13 years, which is well consistent with that of the actual pipeline. Concludingly, the hazard-listing scheme suggested in this research will be very effectively applied to maintaining the underground pipelines.

Time-Lapse Crosswell Seismic Study to Evaluate the Underground Cavity Filling (지하공동 충전효과 평가를 위한 시차 공대공 탄성파 토모그래피 연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • Time-lapse crosswell seismic data, recorded before and after the cavity filling, showed that the filling increased the velocity at a known cavity zone in an old mine site in Inchon area. The seismic response depicted on the tomogram and in conjunction with the geologic data from drillings imply that the size of the cavity may be either small or filled by debris. In this study, I attempted to evaluate the filling effect by analyzing velocity measured from the time-lapse tomograms. The data acquired by a downhole airgun and 24-channel hydrophone system revealed that there exists measurable amounts of source statics. I presented a methodology to estimate the source statics. The procedure for this method is: 1) examine the source firing-time for each source, and remove the effect of irregular firing time, and 2) estimate the residual statics caused by inaccurate source positioning. This proposed multi-step inversion may reduce high frequency numerical noise and enhance the resolution at the zone of interest. The multi-step inversion with different starting models successfully shows the subtle velocity changes at the small cavity zone. The inversion procedure is: 1) conduct an inversion using regular sized cells, and generate an image of gross velocity structure by applying a 2-D median filter on the resulting tomogram, and 2) construct the starting velocity model by modifying the final velocity model from the first phase. The model was modified so that the zone of interest consists of small-sized grids. The final velocity model developed from the baseline survey was as a starting velocity model on the monitor inversion. Since we expected a velocity change only in the cavity zone, in the monitor inversion, we can significantly reduce the number of model parameters by fixing the model out-side the cavity zone equal to the baseline model.

  • PDF

An Optimization Study on a Low-temperature De-NOx Catalyst Coated on Metallic Monolith for Steel Plant Applications (제철소 적용을 위한 저온형 금속지지체 탈질 코팅촉매 최적화 연구)

  • Lee, Chul-Ho;Choi, Jae Hyung;Kim, Myeong Soo;Seo, Byeong Han;Kang, Cheul Hui;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.332-340
    • /
    • 2021
  • With the recent reinforcement of emission standards, it is necessary to make efforts to reduce NOx from air pollutant-emitting workplaces. The NOx reduction method mainly used in industrial facilities is selective catalytic reduction (SCR), and the most commercial SCR catalyst is the ceramic honeycomb catalyst. This study was carried out to reduce the NOx emitted from steel plants by applying De-NOx catalyst coated on metallic monolith. The De-NOx catalyst was synthesized through the optimized coating technique, and the coated catalyst was uniformly and strongly adhered onto the surface of the metallic monolith according to the air jet erosion and bending test. Due to the good thermal conductivity of metallic monolith, the De-NOx catalyst coated on metallic monolith showed good De-NOx efficiency at low temperatures (200 ~ 250 ℃). In addition, the optimal amount of catalyst coating on the metallic monolith surface was confirmed for the design of an economical catalyst. Based on these results, the De-NOx catalyst of commercial grade size was tested in a semi-pilot De-NOx performance facility under a simulated gas similar to the exhaust gas emitted from a steel plant. Even at a low temperature (200 ℃), it showed excellent performance satisfying the emission standard (less than 60 ppm). Therefore, the De-NOx catalyst coated metallic monolith has good physical and chemical properties and showed a good De-NOx efficiency even with the minimum amount of catalyst. Additionally, it was possible to compact and downsize the SCR reactor through the application of a high-density cell. Therefore, we suggest that the proposed De-NOx catalyst coated metallic monolith may be a good alternative De-NOx catalyst for industrial uses such as steel plants, thermal power plants, incineration plants ships, and construction machinery.

A Study on the Faculty Evaluation Model with Considering the Characteristics of Education-Based Colleges (전문대학의 특성을 고려한 교수업적평가 모델 연구)

  • Hwang, Il-Kyu;Kim, Kyeong-Sook;Kwon, O-Young;Ahn, Tae-Won;Park, Young-Tae
    • Journal of vocational education research
    • /
    • v.30 no.4
    • /
    • pp.23-49
    • /
    • 2011
  • Faculty performance evaluation system has been settled down as an uncomfortable but unavoidable system, and it is one of the most important factors to grow the college competitiveness up. In this study, we selected and surveyed faculty evaluation models of several universities and colleges in Korea, and analyzed by comparing each evaluation areas of educational achievement, college-industry collaboration, research, and service. We also identified the properties of the current faculty evaluation models of the junior colleges, and derived several problems from these models such as an imitation of four-year university model, a disorders of job evaluation with respect to the attributes of classified jobs, a large variation of individual item weights, and an insufficient reflection of major characteristics. Based on these surveys and analysis, an improved faculty evaluation model for the junior college is proposed in this study. This model proposed four basic areas-educational achievement, college-industry collaboration, research, and service by considering the importance of the college-industry collaboration in the junior college-as well as the team evaluation area. Weights of the SCI-class paper was selected as a criterion for the arrangement of objective comparison of each evaluation items. We showed the integration method of several different evaluation model with respect to the attributes of classified jobs of each faculties, and evaluation plan of variational characteristics according to the majors of individuals in this model. Finally, we introduced an area fail and rating system to operate efficiently the proposed faculty evaluation model.

Effect of substrate composition on the growth of roses and hydrangeas in artificial ground (인공지반에서 식재지반의 구성이 장미와 수국의 생장에 미치는 영향)

  • You, Soojin;Han, Seung Won;Kim, Kwang Jin;Jeong, Na Ra;Yun, Ji Hye
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.4
    • /
    • pp.658-666
    • /
    • 2020
  • The purpose of this study was to select a suitable planting substrate for multilayered plantings in an apartment landscape space. The experiment was conducted between May to October 2019, at the National Institute of Horticultural and Herbal Science. Planting substrate was prepared in six repetitions of eight treatment zones using mulching material, horticultural soil, bottom ash, and subgrade soil. Rosa hybrid 'Barkarole' and Hydrangea macrophylla 'Nikko Blue' were selected as the experimental plants. We investigated the monthly variation and effect of the substrate type on the growth (plant height, number of branches, leaf length, leaf width, and plant area of the substrates) of the plants. In R. hybrid 'Barkarole' grown in 20 cm of horticultural soil and 10 cm of bottom ash, the plants were taller(102.2±5.8 cm), had more branches (5.5±0.6 each), longer leaves (10.9±1.0 cm), and greater leaf width (6.2±0.5 cm) and plant area (4077.1±416.6 cm2)(p<0.05). H. macrophylla 'Nikko Blue' showed the best growth from 3cm of mulching, 20cm of horticultural topsoil, and 10cm of bottom ash, which resulted in taller plants (43.6±2.1 cm), more branches (4.9±0.8 each), longer leaves (7.2±0.5 cm), and greater leaf width(4.3±0.3 cm) and plant area (344.5±43.2 cm2). Through this study, it was possible to propose an optimal planting substrate for shrubs for multi-layered landscaping.

Validation of Suitable Zooplankton Enumeration Method for Species Diversity Study Using Rarefaction Curve and Extrapolation (종 다양성 평가를 위한 호소 생태계 동물플랑크톤 조사 방법 연구: 희박화 분석(rarefaction analysis)을 이용한 적정 시료 농축 정도 및 부차 시료 추출량의 검증)

  • Hye-Ji Oh;Yerim Choi;Hyunjoon Kim;Geun-Hyeok Hong;Young-Seuk Park;Yong-Jae Kim;Kwang-Hyeon Chang
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.4
    • /
    • pp.274-284
    • /
    • 2022
  • Through sample-size-based rarefaction analyses, we tried to suggest the appropriate degree of sample concentration and sub-sample extraction, as a way to estimate more accurate zooplankton species diversity when assessing biodiversity. When we collected zooplankton from three reservoirs with different environmental characteristics, the estimated species richness (S) and Shannon's H' values showed different changing patterns according to the amount of sub-sample extracted from the whole sample by reservoir. However, consequently, their zooplankton diversity indices were estimated the highest values when analyzed by extracting the largest amount of sub-sample. As a result of rarefaction analysis about sample coverage, in the case of deep eutrophic reservoir (Juam) with high zooplankton species and individual numbers, it was analyzed that 99.8% of the whole samples were represented by only 1 mL of sub-sample based on 100 mL of concentrated samples. On the other hand, in Soyang reservoir, which showed very small species and individual numbers, a relatively low representation at 97% when 10 mL of sub-sample was extracted from the same amount of concentrated sample. As such, the representation of sub-sample for the whole zooplankton sample varies depending on the individual density in the sample collected from the field. If the degree of concentration of samples and the amount of sub-sample extraction are adjusted according to the collected individual density, it is believed that errors that occur when comparing the number of species and diversity indices among different water bodies can be minimized.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

Comparison of Acute Clinical Features and Coronary Involvement in Patients with Kawasaki Disease between Those Younger and Older than One Year of Age (1세 미만과 1세 이상의 가와사끼병 환아에서 급성기 임상양상 및 관상동맥 변화에 대한 비교)

  • Kim, So Young;Lim, Seong Joon;Yun, Sin Weon;Lee, Dong Keun;Choi, Eung Sang
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.6
    • /
    • pp.773-782
    • /
    • 2002
  • Purpose : To identify the necessity of more reasonable diagnostic criteria and the possibility of early prediction of coronary involvement in the higher risk group, we investigated and compared clinical and laboratory findings in the acute phase and coronary involvements in those younger (n=17) and older(n=53) than one year of age in Kawasaki disease(KD). Methods : Retrospective chart reviews were performed on 70 patients with KD who were admitted to the Chung-Ang University Hospital from April 1997 to May 2001. Results : Male were significantly higher in the younger age group(M : F ratio 3.3 : 1 vs. 1.0 : 1, P=0.004). Fever durations before intravenous immunoglobulin(IVIG) and echocardiography were significantly shorter in the younger group($4.6{\pm}1.3$ vs. $6.2{\pm}2.5$, P=0.004 vs. 0.01, respectively). Cases meeting typical diagnostic criteria were significantly less in the younger group(P=0.006). In the laboratory findings, serum albumin, BUN and $K^+$ levels in the acute febrile phase were significantly higher in the younger group(P=0.002, 0.006, <0.001, respectively) and incidences of coronary artery dilatation in the acute phase were significantly higher in the younger group(P=0.01). Conclusion : Although less met the typical diagnostic criteria of KD, infants younger than one year of age are more susceptible to coronary artery change in the acute febrile phase. Therefore, KD should be entertained as a diagnostic possibility in young infants with prolonged fever without distinct fever focus, and echocardiography should be considered as part of the evaluation of these patients, and then early diagnosis and prompt IVIG should be conducted.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF