• Title/Summary/Keyword: 최소검출한계

Search Result 73, Processing Time 0.027 seconds

ELISA Development for the residue of the organophosphorus insecticide acephate (ELISA에 의한 유기인계 살충제 Acephate 잔류물 분석법 개발)

  • Lee, Jae-Koo;Ahn, Ki-Chang;Stoutamire, Donald W.;Gee, Shirley J.;Hammock, Bruce D.
    • The Korean Journal of Pesticide Science
    • /
    • v.5 no.2
    • /
    • pp.1-12
    • /
    • 2001
  • A competitive indirect enzyme-linked immunosorbent assay (ci ELISA) for the organophosphorus insecticide acephate, O,S-dimethyl acetylphosphoramidothioate, was developed using a polyclonal antibody. Three different haptens mimicking the analyze and containing hexanoic acid moiety as a linker were synthesized, and then conjugated with the carrier proteins bovine serum albumin and keyhole limpet hemocyanin by the N-hydroxysuccinimide active ester method. Polyclonal antibodies raised against hapten-KLH conjugates in rabbits and the hapten-BSA conjugates as coating antigens were screened and selected for the assay in the homologous and/or heterologous ELISA system. The effects of various assay conditions, including blocking reagents, detergent content, organic solvents, pH, and preincubation of tile mixture of the polyclonal antibody and the analyze on the sensitivity were evaluated. The $IC_{50}$ value of acephate of 110 ng/mL was obtained in an optimized heterologous system using hapten-3-BSA as a coating antigen and a polyclonal antibody 8377, showing the detection range of 10-1000 ng/mL and the lowest detection limit of 4 ng/mL. The cross-reactivities of the structurally related insecticides, including methamidophos were less than 0.02%. These results indicate that the ELISA could be a convenient and alternative tool for monitoring acephate residues in agricultural products and environmental samples.

  • PDF

Determination of Carbendazim in Commercial Agricultural Products by LC-MS/MS (LC-MS/MS를 이용한 농산물 중 카벤다짐 분석)

  • Hwang, Lae-Hwong;Lee, Sung-Deuk;Kim, Jeong-Gon;Kim, Ji-Young;Park, So-Hyun;Kim, Ji-Hae;Park, Jung-Hyun;Han, Chang-Ho;Kim, Mu-Sang
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.141-146
    • /
    • 2017
  • A rapid and precise method using LC-MS/MS was developed for carbendazim analysis in agricultural products. This compound was extracted with acetonitrile from agricultural products and cleaned up by solid-phase extraction procedure. The limit of detection and quantification were 0.001 mg/kg and 0.004 mg/kg, respectively. The mean recoveries and precision from 4 agricultural products, soybean sprout and mungbean sprout were in the range of 83.3-86.4% and 0.2-3.0% spiked at 1.0 mg/kg and those were in the range of 77.3-90.1% and 1.3-3.8% spiked at 0.02 mg/kg. The present method is faster and more precise compared with the multi-residue method of Korean Food Code. Therefore, we conclude that this method is suitable for carbendazim determination in a wide range of agricultural products.

Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample (저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.123-131
    • /
    • 2018
  • This study compared PENELOPE with measured values from low energy peak to high energy peak to reduce peak to compton ratio and continuum background spectrum using $^{60}Co$, $^{137}Cs$ and mixed volume source. In addition, the change in backscattering and compton edge efficiency was compared with that of PENELOPE through changes in the vicinity of low energy. The results from the mixed volume source are applied to the soil samples to determine how much the minimum detection limits of the soil samples are reduced in the suppression and unsuppressed mode. The compton suppression of the low energy region of $^{60}CO$ (1,173 keV) was considerable, and the Compton edge RF for the $^{137}Cs$ (661 keV) peak was 2.8. In particular, the $^{60}Co$ source emits coincidence gamma rays of 1,173.2 keV and 1,332.5 keV, so compton inhibition was reduced by approximately 21%. RF of compton edges of 1,173 keV and 1,332 keV emitted from a $^{60}Co$ source was 3.2 and 3.4, and the peak to compton edge ratio was improved to 8: 1. And Compared with Penelope, the uncertainty was well within 2%. In compton unsuppressed mode, MDA values of 661 keV, 1,173 keV and 1,332 keV were 0.535, 0.173 and 0.136 Bq/kg, respectively, but decreased in compton suppressed mode to 0.121, 0.00826 and 0.00728 Bq/kg. Thus, Compton suppressed could reduce the background radioactivity and the radioactivity contained in the detector itself.

Determination of geosmin and 2-MIB in Nakdong River using headspace solid phase microextraction and GC-MS (HS-SPME-GC/MS를 이용한 낙동강 수계 하천수 중 조류기원성 냄새물질 분석)

  • Lee, Injung;Lee, Kyoung-Lak;Lim, Tae-Hyo;Park, Jeong-Ja;Cheon, Seuk
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.326-332
    • /
    • 2013
  • Geosmin and 2-methylisoborneol (2-MIB) are volatile organic compounds responsible for the majority of unpleasant taste and odor events in drinking water. Geosmin and 2-MIB are byproducts of blue-green algae (cyanobacteria) with musty and earthy odors. These compounds have odor threshold concentration at ng/L levels. It is needed to develop a sensitive method for determination of geosmin and 2-MIB to control the quality of drinking water. In this study, geosmin and 2-MIB in water samples were determined by gas chromatography-mass spectrometry (GC-MS) with headspace-solid phase microextraction (HS-SMPE). The detection limits of this method were 1.072 ng/L and 1.021 ng/L for geosmin and 2-MIB, respectively. Good accuracy and precision was also obtained by this method. Concentrations of the two compounds were measured in raw waters from Nakdong River in the cyanobacterial blooming season. Water bloom formed by cyanobacteria has been occurred currently in Nakdong River. It is needed to investigate the concentrations of geosmin and 2-MIB to control the quality of drinking water from Nakdong River. Both geosmin and 2-MIB were detected in raw waters from Nakdong River at concentrations ranging from 4 to 24 ng/L and 6 to 16 ng/L, respectively.

Residue analysis of insecticide thiodicarb in sweet persimmon and its safety evaluation (살충제 thiodicarb의 단감 중 잔류분석 및 안전성 평가)

  • Lo, Seog-Cho;Hwang, Cheol-Hwan;Kim, Min-Soo;Ma, Sang-Yong;Han, Seong-Soo
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.3
    • /
    • pp.184-188
    • /
    • 2004
  • The residue analysis of the insecticide thiodicarb in sweet persimmon was analyzed with a gas chromatograph equipped with nitrogen phosphorus detector(NPD) to evaluate efficacy of analysis method and safety of thiodicarb in persimmon. Minimum detectable amount of methomyl oxime, hydrolysate of thiodicarb, was 0.2 ng and detection limit of thiodicarb was 0.05 ppm. The mean recoveries evaluated from untreated samples spiked at 0.5 ppm and 2.5 ppm were $93.9{\pm}3.9$ and $92.8{\pm}2.0%$, respectively. When thiodicarb was sprayed onto the sweet persimmon two times until 40 and 30 days before harvest, three times until 40, 30 and 21 days before harvest, and four times until 40, 30, 21 and 14 days before harvesting, the mean residual amount in sweet persimmon were $1.50{\pm}0.04$, $1.86{\pm}0.04$ and $2.11{\pm}0.12$ ppm, respectively. It would be safe when thiodicarb 40% WP is treated four times 14 days before harvesting to control fruit moth in sweet persimmon.

Quantitative Analysis of Residual 24 Organochlorine POPs in Sundried Salts (천일염 중 유기염소계 잔류성 유기오염물질(POPs) 잔류분석)

  • Choi, Geun-Hyoung;Park, Mi-Ran;Park, Jong-Min;Hong, Su-Myeong;Kwon, Oh-Kyoung;Park, Yun-Ki;Kim, Jin-Hyo
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.502-506
    • /
    • 2011
  • Most countries have the legislation and regulation for POPs control in food. In here, we studied the quantitative analysis of 24 organochlorine POPs (${\alpha}$-HCH 1, ${\beta}$-HCH 2, ${\gamma}$-HCH 3, ${\delta}$-HCH 4, trans-chlrodane 5, 2,4'-DDE 6, ${\alpha}$-endosulfan 7, cis-chlordane 8, 2,4'-DDD 9, endrin 10, ${\beta}$-endosulfan 11, 2,4'-DDT 12, endosulfan sulfate 13, HCB 14, aldrin 15, trans-nonachlor 16, 4,4'-DDE 17, dieldrin 18, 4,4'-DDD 19, cis-nonachlor 20, 4,4'-DDT 21, heptachlor 22, heptachlor epoxide 23 and mirex 24) with GC-ECD. The retention time of analytes were ranged between 19.18 min and 34.69 min, and their peak intervals were over 0.05 min at least. LOQs were ranged 0.003 ~ 0.033 ng/g, and their recovery rates were showed 60.9 ~ 120.8% on the 0.1 ng/g concentration of 24 organochlorine POPs. All tested 30 sundried salts were collected on Korean retailed market, and any analyte was not found in all the samples on LOQ levels.

Simultaneous Spectrophotometric Determination of Copper, Nickel, and Zinc Using 1-(2-Thiazolylazo)-2-Naphthol in the Presence of Triton X-100 Using Chemometric Methods (화학계량학적 방법을 사용한 Triton X-100이 함유된 1-(2-Thiazolylazo)-2-Naphthol을 사용한 구리, 니켈과 아연의 동시 분광광도법적 정량)

  • Low, Kah Hin;Zain, Sharifuddin Md.;Abas, Mhd. Radzi;Misran, Misni;Mohd, Mustafa Ali
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.717-726
    • /
    • 2009
  • Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ in synthetic mixture and tap water.

Development of Immunochromatography for Detection of Escherichia coli O157:H7 Contaminated in Meats and Sprouts (육류 및 새싹채소에 오염된 Escherichia coli O157:H7의 신속검출을 위한 면역크로마토그래피법의 개발)

  • Lee, Won-Gyeong;Ryu, Hee-Jeong;Song, Jeong-Un;Kim, Kyeong-Yeol;Chung, Do-Yeong;Kim, Jeong-Sook;Shim, Won-Bo;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.618-623
    • /
    • 2011
  • Escherichia coli O157:H7 has been considered as a significant food-borne pathogen since its role in causing hemorrhagic colitis and hemolytic uremic syndrome in humans was recognized. In this study, we developed an immunochromatography (ICG) assay for the detection of E. coli O157:H7. E. coli O157:H7 monoclonal antibody (EC MAb) and colloidal gold were conjugated and its specificity was determined by the ICG treated with EC MAb and antimouse IgG at test and control lines, respectively. The detection limit of the ICG was $1{\times}10^5$ CFU/mL, and no crossreactivity was observed to other E. coli strains and major food-borne pathogens. To determine the minimum enrichment time for the ICG, meats and sprouts were inoculated with $1{\times}10$ CFU/100 ${\mu}L$ of E. coli O157:H7. After enrichment time of 10 and 2 h for meats and sprouts, respectively, up to $1{\times}10$ CFU/100 ${\mu}L$ of E. coli O157:H7 could be detected by ICG.

Fragment Analysis for Detection of the FLT3-Internal Tandem Duplication: Comparison with Conventional PCR and Sanger Sequencing (FLT3-ITD 검출을 위한 절편분석법: 일반 중합효소연쇄반응 및 직접염기서열분석법과의 비교)

  • Lee, GunDong;Kim, Jeongeun;Lee, SangYoon;Jang, Woori;Park, Joonhong;Chae, Hyojin;Kim, Myungshin;Kim, Yonggoo
    • Laboratory Medicine Online
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Background: We evaluated a sensitive and quantitative method utilizing fragment analysis of the fms-like tyrosine kinase 3-internal tandem duplication (FLT3-ITD), simultaneously measuring mutant allele burden and length, and verified the analytical performance. Methods: The number and allelic burden of FLT3-ITD mutations was determined by fragment analysis. Serial mixtures of mutant and wild-type plasmid DNA were used to calculate the limit of detection of fragment analysis, conventional PCR, and Sanger sequencing. Specificity was evaluated using DNA samples derived from 50 normal donors. Results of fragment analysis were compared to those of conventional PCR, using 481 AML specimens. Results: Defined mixtures were consistently and accurately identified by fragment analysis at a 5% relative concentration of mutant to wild-type, and at 10% and 20% ratios by conventional PCR and direct sequencing, respectively. No false positivity was identified. Among 481 AML specimens, 40.1% (193/481) had FLT3-ITD mutations. The mutant allele burden (1.7-94.1%; median, 28.2%) and repeated length of the mutation (14-153 bp; median, 49 bp) were variable. The concordance rate between fragment analysis and conventional PCR was 97.7% (470/481). Fragment analysis was more sensitive than conventional PCR and detected 11 additional cases: seven had mutations below 10%, three cases represented conventional PCR failure, and one case showed false negativity because of short ITD length (14 bp). Conclusions: The new fragment analysis method proved to be sensitive and reliable for the detection and monitoring of FLT3-ITD in patients with AML. This could be used to simultaneously assess ITD mutant allele burden and length.

Detection of Megalocytivirus in shellfish using PCR with various DNA extraction methods (다양한 PCR용 DNA 추출법에 의한 패류 내 Megalocytivirus의 검출)

  • Kim, Jin-Woo;Cho, Mi-Young;Jin, Ji-Woong;Kim, Ki-Hong;Jeong, Hyun-Do;Kim, Kwang-Il
    • Journal of fish pathology
    • /
    • v.24 no.2
    • /
    • pp.65-73
    • /
    • 2011
  • In analysis of DNA viruses from the contaminated shellfish using PCR, preparation method of template DNA is an important factor to get enough copy number of viruses. In this study, we evaluated the efficiency of PCR template of Megalocytivirus (sT50mg-D) DNA obtained from 50 mg digestive gland homogenate of oyster using commercial method, and compared with that obtained from 5 g of the same tissues (T5g-D) after PEG precipitation procedures of virus. Both templates DNA suspended in the same volume of distilled water showed positive results by primary PCR with 35 cycles, and the presence of Megalocytivirus was confirmed in oysters collected from cultured farms in Korea. Moreover, PCR with sT50mg-D allowed us to discriminate the contaminated oyster individually, that can not be done in PCR with T5g-D prepared from the mixture of three different individual oyster to get 5 g digestive gland homogenate. In quantitative analysis with real time PCR, Megalocytivirus concentrations in 50 ${\mu}l$ templates prepared using 0.5~50 mg of one positive sample were appeared in the range 6.14E+00~1.2E+02/${\mu}l$. We were not able to get positive result using template DNA contained less than 6.14E+00 copies. Consequently, 2-step PCR performed with DNA extracts from oyster homogenate of small amount (sT50mg-D) i) was enough to detect the contaminated Megalocytivirus in shellfish, ii) allowed us to do the analysis for individual shellfish rather than mixture of several shellfish and iii) showed the presence of Megalocytivirus in oyster from Korea.