• Title/Summary/Keyword: 최소검출한계

Search Result 73, Processing Time 0.026 seconds

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Optimal HPLC Condition for Simultaneous Determination of Anthocyanins in Black Soybean Seed Coats (검정콩 함유 안토시아닌의 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.4
    • /
    • pp.359-368
    • /
    • 2008
  • Black soybean has been widely utilized as foods and oriental medicinal materials. The pigmentation in the seed coat of black soybean is due to accumulate anthocyanins in the epidermis palisade layer. The anthocyanins of black soybean seed coat are considered as a parameter of quality evaluation of black soybean. Therefore, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of anthocyanins in black soybean seed coats extracts. The efficient HPLC analytical condition of D3G, C3G, and Pt3G contained extracts of black soybean seed coats was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 5% aqueous formic acid, and mobile phase B, comprising 5% formic acid - acetonitrile, and delivered at a flow rate of 0.7 mL/min as follows: $0{\sim}35\;min$, $90%\;A{\sim}60%\;A$; 36 min, 90% A; 46 min, 90% A. The UV-VIS. detection wavelength was set at 520 nm. The limit of detection (LOD) for D3G, C3G, and Pt3G were under 10 ng/mL.

Characteristics of $CaSO_4$:Dy TL Dosimeters by Determining LLDs, Fadings and Sensitivity Changes in Repeat Uses (최소검출한계, 잠상퇴행 및 반복사용으로 인한 감도면화 결정에 의한 $CaSO_4$:Dy 열형광선량계 특성)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Hyung-Sub;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.161-170
    • /
    • 1997
  • Theoretical and experimental determination of the lower limits of detection (LLD) of C-300-A $CaSO_4$:Dy TL dosimeters which are currently used for the personnel monitoring in Korea Atomic Energy Research Institute(KAERI) are described with a critical level which is defined as the signal level above which a result has a probability of being due to a fluctuation of the background. The personnel monitoring processors can derived easily the LLD of their system using this method with the background readings of their service interval and the irradiation readings of the known doses. Experimental studies were also conducted for the fading rates of the dosimeters with the temperatures and humidities for 3 months. Finally sensitivity changes in repeat uses were measured for 40 times consecutive uses of the dosimeters. The applications of the experimental results of fading rates and sensitivity changes in real personnel monitoring services are discussed briefly.

  • PDF

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.

Development of Prototype Liquid Scintillator System for Monitoring Liquid Radioactive Waste (배수 모니터링 액체섬광검출시스템의 프로토 타입 개발)

  • Nam, Uk-Won;Seon, Kwang-Il;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.173-182
    • /
    • 2003
  • A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples $(^3H,\;^{14}C,\;^{36}Cl\;and\;^{90}Sr)$. Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values.

Development of Analytical Method for Rutin in Buckwheat Plant using High Performance Liquid Chromatography (메밀 식물체 함유 Rutin의 HPLC 분석방법 개발)

  • Choung Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.181-186
    • /
    • 2005
  • This experiment was conducted to know the appropriate methods for extraction and determination of rutin contained buckwheat plants. The efficient HPLC analytical condition of rutin contained buckwheat plants was developed. The gradient elution employed a $250mm\times4.6mm$ i.d. Tosoh ODS 120T column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of $2\%$ Acetic $acid-45\%$ Acetonitrile, and mobile phase B, comprising $2\%$ aqueous acetic acid, and delivered at a flow rate of 1mL/min as follows: 0-18 min, $50-100\%$ A; 18-20 min, $100-50\%$ A; 20-22 min, $50\%$ A. The UV detection wavelength was set at 355 nm. The limit of detection (LOD) for rutin standard compound was 20 ng/mL. And, the higher content of rutin in the extracts was obtained by $80^{\circ}C$ reflex extraction for 120 min. from plants of buckwheat using ethanol.

Enzyme-linked immunosorbent assay (ELISA) for the detection of RVS (Retrovirus of Salmonid) (ELISA법을 이용한 연어과 어류의 RVS 검출(Retrovirus of Salmonid) 검출)

  • Oh, Myung-Joo;Yoshimizu, Mamoru
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.169-176
    • /
    • 1996
  • An indirect double antibody enzyme-linked immunosorbent assay (ELISA) was developed for rapid detection of a new virus isolated from abnormally swimming salmonid fish, RVS (Retrovirus of salmonid). Results using brain tissue homogenates, and infected cell cultures are described. The sensitivity of the methods is $10^{2.6}$ $TCID_{50}/100{\mu}l$ of the examined cell culture fluid. The specificity was confirmed by the ELISA inhibition test and virological examinations. Viral antigen could be detected in artificially infected fish tissue homogenates. The assay will allow the diagnosis of RVS-infected fish within a day.

  • PDF

Comparative Evaluation of Loop-Mediated Isothermal Amplification (LAMP) and Conventional PCR for Detection of Shiga-Toxin-Producing Escherichia coli (STEC) in Various Food Products

  • Hyejin Jang;Yong Sun Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.347-355
    • /
    • 2023
  • In this study, polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) were compared in terms of their ability to detect shiga-toxin-producing Escherichia coli (STEC). Various foods were artificially inoculated with STEC to evaluate the limit of detection (LOD), limit of quantification (LOQ), sensitivity, specificity, and efficiency of PCR and LAMP. The LODs were ≤104 and ≤103 CFU/mL for PCR and LAMP, respectively. The LOQs did not differ between PCR and LAMP. However, of the four considered food types, the sensitivities differed by a maximum of 11.1% for seasoned meat and by a minimum of 8.1% for ground beef. LAMP had higher sensitivity than that of PCR and 100% specificity for all four food types. Therefore, LAMP is a reliable molecular method for detecting STEC as comparable to PCR assay, and its specificity and sensitivity are superior to those of PCR, depending on the food type.

Determination of Cyhalofop-butyl and its Metabolite in Water and Soil by Liquid Chromatography (LC를 이용한 물과 토양 중 Cyhalofop-butyl과 대사물질의 분석)

  • Hem, Lina;Choi, Jeong-Heui;Liu, Xue;Khay, Sathya;Shim, Jae-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.4
    • /
    • pp.315-322
    • /
    • 2008
  • In this study, a simple, effective, and sensitive method has been developed for the quantitative residue analysis of cyhalofop-butyl and its metabolite cyhalofop acid in water and soil when kept under laboratory conditions. The content of cyholofop-butyl and cyhalofop acid in water and soil was analyzed by first purifying the compounds through liquid-liquid extraction and partitioning followed by Silica gel (adsorption) chromatography. Upon the completion of the purification step the residual levels were monitored through high-performance liquid chromatography (HPLC) using a UV absorbance detector. The recoveries of cyhalofop-butyl from three replicates spiked at two different concentrations ranged from 82.5 to 100.0% and from 66.7 to 97.9% in water and soil, respectively. The limit of detection and minimum detection level of cyhalofop-butyl in water and soil was 0.02 ppm and 10 ng, respectively. The recoveries of cyhalofop acid ranged from 80.7 to 104.8% in water and from 76.9 to 98.1 % in soil. The limit of detection of cyhalofop acid was 0.005 ppm in water and 0.01 ppm in soil, while the minimum detection level was 2 ng both in water and soil. The half-live of cyhalofop-butyl was 4.14 and 6.6 days in water and soil, respectively. The method was successfully applied to evaluate cyhalofop-butyl residues in water and soil applied aj. 30% emulsion, oil in water (EW) product.

A Study on Minimum Detection Limit of Environmental Radioactivity in HPGe Detector (HPGe 검출기에서 환경방사능측정의 검출하한치에 관한 연구)

  • Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.5-10
    • /
    • 2011
  • Based on basic concept of detection limit, sample measurement time & background measurement time was considered, and MDA values according to background measurement time and sample measurement time in land samples(river soil, surface soil, drinking water, underground water, surface water, pine leaf, mugwort) analysis among environmental samples were compared. Seeing the water sample analysis result, it was shown that most of the samples were not detected, and most of the samples in land specimen analysis showed to be below the detection limit of "Ministry of Education, Science and Technology Announcement Je-2008-28-ho", but $^{137}Cs$ which is one of artificial radioactive nuclide was detected in some samples. It can be traced back to 1950s and 1960s when nuclear tests were carried out in atmosphere and catastrophic Chernobyl atomic power station accident that caused fallouts in the sky, and this is common level of detection that can be observed worldwide. Seeing the result that the $^{134}Cs$(which is a isotope of $^{137}Cs$, and it has relatively short half life) was not detected in all samples, it can be considered it doesn't affect to the operation of atomic power station.