• Title/Summary/Keyword: 최대 사거리

Search Result 50, Processing Time 0.028 seconds

Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography (컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구)

  • Lee, Seung-Young;Hong, Joo-Wan;Kang, Su-Mi;Kim, Su-Bin;Joon, Sang-Hoon;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.713-720
    • /
    • 2019
  • The purpose of this study was to propose a new measurement method for accurate measurement of vessel diameter in computed tomography angiography(CTA). CTA test was performed after non-ionic iodine contrast agent was flowed at a constant rate to self-maded perfusion phantom. After obtaining raw data, images were reconstructed with multi-planar reconstruction(MPR) and maximal intensity projection(MIP). Diameters of vascular models were measured for each technique. Relative and conventional measurements were then compared. The mean diameter of the vascular model was closer to the actual measurement when relative measurement was used compared to that when conventional measurement was used both in MPR and MIP. Relative measurements of MPR and MIP were closer to actual measurement than those of conventional measurement (34% VS, 24%, p<0.05). The relative measurement method proposed in this study was closer to the actual measurement than the conventional measurement method. However, both test methods were still larger than actual results. Therefore, further study of relative measurement method is needed using this study as basic data.

A Study on The Performance and Fuel Economy of Diesel Vehicles According to Change in Fuel Properties (연료물성에 따른 경유 차량의 성능 및 에너지소비효율 연구)

  • Noh, Kyeong-Ha;Lee, Min-Ho;Kim, Ki-Ho;Lee, Jung-Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.667-675
    • /
    • 2018
  • Increasing emissions regulations and demand of high-efficiency cars that travels a lot of distance with less fuel, there is growing interest in Energy Consumption Efficiency. Korean energy consumption efficiency compute combined Fuel Economy by driven city & highway driving mode and present final Energy Consumption Efficiency as using 5-cycle correction formula. Energy consumption efficiency is computed Carbon-balance-method, when used burning fuel play a key role in vehicle performance & Energy Consumption Efficiency. In Korea, vehicle fuel is circulate by Petroleum and Petroleum Alternative Business Act, there is property difference in quality standard because petroleum sector's refine method or type of crude oil. It does not appear a big difference according to fuel, because it sets steady quality standard, it may affect the performance of automobile. Thus, in research We purchase a few diesel fuel which circulated in the market in summer season though directly-managed-gas station by petroleum sector, resolve property each of fuel, we compute Fuel Economy each of them. We analyze into change depend on applying for property as nowadays utilizing Energy Consumption Efficiency calculating formula of gasoline and diesel fuel. As result, Density each of sample fuel has a maximum difference roughly 0.9%, net heat value each of sample fuel has difference 1.6%, result of current Energy Consumption Efficiency each of sample fuel has a difference roughly 1% at city drive mode, 1.4% at highway drive mode. Result of use gasoline calculator formula shows less 6% result than nowadays utilizing Energy Consumption Efficiency calculating formula, each of sample's Energy Consumption Efficiency shows maximum roughly 1.4% result in city & highway drive mode.

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.

Analysis of Building Vulnerabilities to Typhoon Disaster Based on Damage Loss Data (태풍 재해에 대한 건물 취약성의 피해손실 데이터 기반 분석)

  • Ahn, Sung-Jin;Kim, Tae-Hui;Son, Ki-Young;Kim, Ji-Myong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.529-538
    • /
    • 2019
  • Typhoons can cause significant financial damage worldwide. For this reason, states, local governments and insurance companies attempt to quantify and mitigate the financial risks related to these natural disasters by developing a typhoon risk assessment model. As such, the importance of typhoon risk assessment models is increasing, and it is also important to reflect local vulnerabilities to enable sophisticated assessments. Although a practical study of economic losses associated with natural disasters has identified essential risk indicators, comprehensive studies covering the correlation between vulnerability and economic loss are still needed. The purpose of this study is to identify typhoon damage indicators and to develop evaluation indicators for typhoon damage prediction functions, utilizing the loses from Typhoon Maemi as data. This study analyzes actual loss records of Typhoon Maemi provided by local insurance companies to prepare for a scenario of maximum losses. To create a vulnerability function, the authors used the wind speed and distance from the coast and the total value of property, construction type, floors, and underground floor indicators. The results and metrics of this study provide practical guidelines for government agencies and insurance companies in developing vulnerability functions that reflect the actual financial losses and regional vulnerabilities of buildings.

Tactile Sensibility Factors of Traditional Silk Fabrics (전통 견직물의 촉각적 감성요인)

  • Yi, Eun-Jou
    • Science of Emotion and Sensibility
    • /
    • v.10 no.1
    • /
    • pp.99-111
    • /
    • 2007
  • In order to identify tactile sensibility factors of traditional silk fabrics and to provide prediction models for the sensibility factors by mechanical properties, seventeen different traditional silk fabrics were evaluated in terms of both tactile sensation and sensibility by using a modified magnitude estimation line scale Gongdan and Newttong with lower values for surface roughness(SMD), bending rigidity(B), and compression resilience(RC) were rated as softer, smoother, fluffier, and more pliable in tactile sensation than any other traditional silk fabrics whereas Nobangju haying higher B, SMD, and tensile resilience(RT) was touched as crisper, more rustling, and springier. Three different tactile sensibility factors including 'Feminine', 'Natural', and 'Casual' were obtained significantly by grouping fifteen different tactile sensibility descriptors. In the prediction models sensibility 'Feminine' was explained positively by SMD, which was supported by the fact that both Gongdan and Newtton were perceived as more feminine. Sensibility 'Natural' that was felt stronger as for Myoungju and Sa was predicted negatively by both fabric thickness(T) and RT. Finally, RC, elongation at maximum load (EM), and T predicted sensibility 'Casual' negatively, which results in its higher factor scores for Myoungju and Shantung, respectively.

  • PDF

Characteristics of Fuel Mixing and Evaporation Based on Impingement Plate Shape in a Denitrification NOx System with a Secondary Injection Unit (2차 분사시스템을 갖는 De-NOx 시스템의 충돌판 형상에 따른 연료의 혼합 및 증발 특성 향상을 위한 연구)

  • Park, Sangki;Oh, Jungmo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.884-891
    • /
    • 2016
  • A secondary injection system in a diesel engine has benefits: it can be controlled independently without interrupting engine control, it can be adapted to various layouts for exhaust systems, and it pose no reductant dilution problems compared to post injection systems in the combustion chamber or other supplemental reductant injections. In a secondary injection system, the efficiency of the catalyst depends on the method of reducing the supply. The reductant needs to be maintained and optimized with constant pressure, the positions and angles of injector is a very important factor. The concentration and amount of reductant can be changed by adjusting secondary injection conditions. However, secondary injection is highly dependent upon the type of injector, injection pressure, atomization, spray technology, etc. Therefore, it is necessary to establish injection conditions the spray characteristics must be well-understood, such as spray penetration, sauter mean diameter, spray angle, injection quantity, etc. Uniform distribution of the reductant corresponding to the maximum NOx reduction in the DeNOx catalyst system must also assured. With this goal in mind, the spray characteristics and impingement plate types of a secondary injector were analyzed using visualization and digital image processing techniques.

Effects of Changes in Collimation Size and the sub ROI on Exposure Index of Hand Radiography (손 방사선검사에서 조사야 크기와 보조관심영역 변화가 노출지수 값에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.851-857
    • /
    • 2023
  • The purpose of this study is to investigate the effect of changes in collimation size and sub ROI on exposure index(EI) in hand radiography, present collimation size and EI suitable for average hand size of Koreans, and present the effect of changes in sub ROI on EI. The subjects of this study were hand-wrist phantom, and the exposure conditions were set to 55 kVp, 125, mA, and 6.25 mAs, and source to image receptor distance was applied to 110 cm. Based on the vendor recommended sub-ROI (18.7" × 18.7", 8" × 10", 8" × 7.4", 6" × 7.4")and the textbook's recommended sub-ROI 8" × 10", each obtaining 30 images, and comparing the EI shown in the equipment. The EI according to the change in the size of the collimation were 1663.7±4.52, 8"×10" is 1489.1±4.49, 8"×7.4" is 1716.9±3.00, 6"×7.4" is 168.7±3.66 for each EI, and the average value of each value was statistically significant. The average EI according to the sub ROI change was 1489.1±4.49 for SS, LS was 1694.8±5.19 for AEC, 2052.9±5.96, VR was 1548.3±3.20, and HR was 1663.2±4.33. The appropriate field size considering the hand size of Koreans was found to be 8"×7.4". In addition, when the field size increases based on the generally known field size (8"×10") during hand radiography, the EI value changes from a maximum of 15% to a minimum of 11%, and the sub ROI shape based on sub ROI 'SS' Depending on the change, the EI value increased from a maximum of 37% to a minimum of 3%.

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Locational and Constructional Characteristics of Imrijeong & Palgwae-jeong in Nonsan - Focused on the Relation with Jukrim-Seowon - (논산 임리정(臨履亭)과 팔괘정(八卦亭)의 입지 및 조영 특성 - 죽림서원(竹林書院)과의 관계를 중심으로 -)

  • Lee, Hyun-Woo;Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.70-81
    • /
    • 2013
  • In this study, the locational and constructional characteristics of Jukrimseowon, pavilion Imrijeong, and Palgwaejeong located in Nonsan, Ganggyung-eup were reviewed and the interrelation of these three places were studied through references including records of those days; Sagyeyonbo(沙溪年譜), Jukrimseowon dorok(竹林書院都錄), Imrijeonggi(臨履亭記), Jukrimseowon Myojeongbi(竹林書院廟庭碑), Namyurok(南遊錄). The result is as follows. Jukrimseowon enshrining Yukhyeon(六賢) is arranged as 'Hongsalmoon-Woisalmoon-Dongjae(憲章堂; Heonjangdang)' and 'LIbrary-Naesammoon(神門; shin moon)-Sau(竹林祠: Jukimsa)', excluding a lecture hall. In case of Sagye Jangsang Kim's Imrijeong(沙溪金長生) and Uam Shiyoel Song(尤庵宋時烈)'s Palgwaejeong respectively constructed 50 meters and 10 meters each away from Jurimseowon, detail designs such as scale, roofs, surface, windows, doors, and tablets as well as its prospect are nearly identified. Especially Taking Imrijeong and Palgwaejeong's locational conditions composed of rocks centered on Jukrimseowon, those are maintain the bilateral symmetry as much as possible and surround the shrine. It appeared that the Jukrimseowon's shrine enshrining Yulgok(栗谷) and Ugye(牛溪) was rebuilt during the reconstruction of auditoriums because of political conditions after the renovation of Kiing Injo and it was called as 'Hwangsanseowon(黃山書院)' with Imrijeong which was a lecture hall. It was an inevitable consequence to keep the bilateral symmetry which is a basic order of auditorium structure by maintaining and using Imrijeong and Palgwaejeong as a lecture hall of the auditorium after the reconstruction at least. Consequently, the desperate attempt to adjust the arrangement and visual imbalance of Imrijeong built with periodical differences and Hwangsanseowon resulted from the construction of shrine was Palgwaejeong built under Monggoibyuk of Hwansan Taken these circumstances together, Jukrimseowon is a 'shrine-centered auditorium' with characteristics of auditorium, constructed by integrating Imrijeong which was used as a lecture hall after the construction of shrine and Palgwaejeong repaired through the reconstruction. The construction of Palgwaejeong and the formative conformity with Imrijeong are assumed as an consequence intended for the compensation of Jukrimseowon's function and role as an auditorium. This study will provide an opportunity to focus on the auditorium and pavilion's complementary function as well as the Confucian and constructional functions by revealing the fact that pavilions were established as a complementary facility for the lecture hall of auditorium.

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF