• Title/Summary/Keyword: 최대환기량

Search Result 83, Processing Time 0.029 seconds

The Effects of the Multiple Pulmonary Function in the 20s People of Mild Intellectual Disabilities to Balloons Blowing Exercise (풍선불기운동이 20대 경도 지적장애인의 복합적인 폐기능에 미치는 영향)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Kim, Dae-Rong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.121-126
    • /
    • 2021
  • The purpose of this study is to investigate the effect of balloon blowing exercise on multiple pulmonary function and maximum voluntary ventilation in patients with mild intellectual disabilities in their 20s. 10 people in the experimental group and 10 people in the control group participated in the experiment. The experimental group performed the balloon blowing exercise for 30 minutes a day, and the control group performed the diaphragm breathing exercise for 30 minutes each. The subjects measured voluntary capacity and maximal voluntary ventilation using Fitmate before and after the experiment. Subjects were assessed with Vital capacity(VC) and Maximal voluntary ventilation(MVV) before and after the test and the results were compared with the paired t test. Data analysis was performed with SPSS win 18.0. After the experiment, the experimental group showed higher lung capacity and maximum ventilation than the control group. Through this study, the experimental group increased voluntary capacity and maximum voluntary ventilation more than the control group. It is thought that the quality of life can be improved if we continuously manage the health of intellectuals by developing various breathing exercise programs.

The Effects on the Convergence Vital Capacity and Maximal Voluntary Volume of 20's Normals Proprioceptive Neuromuscular Facilitation Respiration Exercise by Sitting Position (45도 기대어 앉은 자세에서 PNF호흡운동이 20대 정상인의 복합적 폐활량과 최대환기량에 미치는 영향)

  • Kim, Ok-Ki;Park, Seung-Hwan;Seo, Kyo-Chul
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.43-49
    • /
    • 2020
  • The purpose of this study was to determine whether PNF respiratory exercise increases the vital capacity and maximal voluntary volume of 20s normal adults by 45° leaning sitting position. Twenty normal adults in their 20s were randomly assigned to an experimental group and control group. Over the course of four weeks, the experimental group participated in PNF respiration exercises by 45° leaning position for 30 minutes three per week. And the control group participated in diaphragm respiration exercises by 45° leaning position for 30 minutes three times per week. Subjects were assessed post-test by measurement of vital capacity, maximal voluntary volume. Our findings show that the experimental group had significant improvements in vital capacity, maximal voluntary volume(p<.05). In this study, the experimental group showed more improvement in pulmonary function, which indicates that the PNF respiratory exercise by 45° leaning sitting position is effective at increasing the pulmonary function of normal adults.

Development of Exhaust Fan with an Embedded Controller for Windowless Swine Housing (무창돈사를 위한 컨트롤러 일체형 환기팬 개발)

  • Kim, Woong
    • Journal of agriculture & life science
    • /
    • v.50 no.2
    • /
    • pp.187-194
    • /
    • 2016
  • The purpose of this study was to analyze temperature distribution characteristics using a model swine housing for temperature sensor adjustable positioning and developed a sensor and controller embedded exhaust fans utilizing ICT fusion technology for windowless swine housing. Temperature measured by the sensor attached on the exhaust fan was also determined that there is no problem, the temperature is located in the upper fan given the measured errors shown in the 1℃ temperature difference between the lower temperature than the other positions in the model swine housing. The performance of the exhaust fan at maximum output was found to be 1920rpm, air flow rate 125㎥/min. When the open area ratio of 70% one proper air volume of the exhaust fan was found to be 75㎥/min, 60pa. Maximum efficiency in all of the output of the exhaust fan is exhibited at about 70% open area ratio of the damper. The number of revolution of the exhaust fan was 1920rpm when the output was a maximum of 100%. AC output phase of the pulse duty ratio change of the controller was shown to change without delay. It was determined that the instant fan speed control is possible.

An experimental study on the performance of the separate type heat pipe in accordance with the refrigerant charge (냉매 충진량에 따른 분리형 히트파이프 성능에 관한 실험적 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1600-1604
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this research, we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. Heat-pipe used in this study was designated separately to be applied to a ventilation system. The working fluid was R22, which was filled from 40 to 55 (%vol.) by 5(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

The Estimation and Application of Optimum Design Variables for Road Tunnel Ventilation System Based on Statistical Analysis (통계적 분석을 이용한 터널 환기시스템 적정설계변수의 산정 및 적용에 관한 연구)

  • 이보영;유용호;김진
    • Tunnel and Underground Space
    • /
    • v.14 no.5
    • /
    • pp.373-380
    • /
    • 2004
  • In this study, the emission rate of pollutant was modified according to the published standards, and the distribution of pollutant concentration was analyzed for each vehicle velocity. This modified emission rate was applied to a model tunnel and it was proved that the required air quantity was reduced to 49%, compared to the PIARC method. From the simulation result, it was proved by using statistics that the most sensitive factor among them is the friction coefficient and it was modified to the value in the range of 0.018 to 0.021. It is also expected that the required air quantity can be decreased form 14.4% to 19.2% according as the coefficient is applied to the domestic model tunnels. In conclusion, it is proposed that the number of jet fans can be reduced and the annual operating cost can be curtailed as well.

Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season (자연환기식 육계사내의 환기효율성 조사연구-( I )하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Most of broiler houses in Korea have the trouble of environmental control such as suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens. Accordingly, it is very urgent to develop optimum designs of naturally and mechanically ventilated broiler houses for Korean climate. In this study, the internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were measured at a naturally ventilated broiler house. The data were collected during summer season including local weather data. It was found that the difference between measured and optimum air temperatures was $14.0^{\circ}C$ in maximum during the summer time. The daily maximum range of internal averaged air temperature was found $10.5^{\circ}C$ while the uniformity was $5.2^{\circ}C$ in maximum. The maximum, average, and minimum internal averaged relative humidity were 89.3%, 73.7%, and 49.2%, respectively while locally measured were 95.1% and 47.2%, respectively in maximum and minimum. Considering Temperature-humidity index, during summer season, over 97% of totally rearing period was shown that counter plan is needed for thermal stress while it was very dangerous situation for 22% of the rearing period. The ammonia gas and dust concentrations were seriously affected by the broilers activity, growth level, and relative humidity.

  • PDF

The Effects on the Aerobic Function of Major in Dance and Common Students after Treadmill Gait Exercise (트레드밀 보행운동이 무용전공학생과 일반학생의 유산소 운동능력에 대한 비교)

  • Seo, Kyo-Chul;Park, Seung-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.5
    • /
    • pp.79-84
    • /
    • 2019
  • The purpose of this study was to examine the effects of treadmill exercise on the aerobic function of dance majors in their 20s. The subjects consisted of 10 female Korean dance majors in their 20s as an experimental group and 10 normal female college students as a control group, and both groups conducted treadmill gait training. Their heart rate recovery (HRR), maximal oxygen uptake (MOU), maximal voluntary ventilation (MVV), and lactate recovery rate (LRR) were measured before and after the experiment. The comparison of changes in the subjects' aerobic function before and after the experiment showed that the experimental group gained more significant effects on HRR and LRR than the control group. Therefore, treadmill gait training may help Korean dance majors to improve their basic physical strength by enhancing their aerobic function, and the findings of this study are likely to provide basic data to support scientific exercise prescriptions.

Effect of Side Openings and Greenhouse Width on the Natural Ventilation Performance (측창 및 온실 폭이 자연환기 성능에 미치는 영향)

  • Hyun Woo Lee;Young Hoe Woo;Jong Won Lee
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2023
  • In summer, the natural ventilation performance for varying greenhouse width is very important in the glasshouses for year round cultivation. The effect of the side openings and greenhouse width on natural ventilation performance was analyzed by simulation. The necessary ventilation rate with different solar radiation transmittance increased significantly when the outside temperature grows higher. The necessary ventilation rate of 40% transmittance was about half of that of 90% transmittance. In consequence, shading effect on temperature control in greenhouse is significant in summer. When the total area of the openings for ventilation is constant, the maximum ventilation rate happens when the area of roof openings is equal to the area of side openings. This maximum ventilation rate is about 3 times of that of the greenhouse with roof openings and without side openings. Therefore, the side openings are advantageous to improve the natural ventilation in greenhouses. As the greenhouse width increases, the influence of side openings on the ventilation rate is becoming smaller. If the natural ventilation rate of the greenhouse with roof and side openings is to become double of that of the roof openings only, the width should be narrower than 38.4m for the Venlo type and 64m for Wide span type.

Evaluation of the Amount of Gas Generated through Combustion of Wood Charcoal and Agglomerated Charcoal Depending on Air Ventilation (숯과 성형숯의 연소를 통해 배출되는 가스 발생량 및 실내공간 환기량 평가)

  • JU, Young Min;JEONG, Hanseob;CHEA, Kwang-Seok;AHN, Byung-Jun;LEE, Soo Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.847-860
    • /
    • 2020
  • This study was conducted into combustion characteristics and gases generated by the combustion of charcoal and agglomerated charcoal distributed in the domestic using a combustion chamber based on the average space per crater of a charcoal-grilled restaurant in South Korea. Each of the three types of charcoals and agglomerated wood charcoals was analyzed for fuel and combustion characteristics. In addition, the concentration changes of CO, CO2, NOx, and O2 were measured for 20 minutes depending on ventilation. As a result, CO yield without ventilation was measured in the range of 1390 to 4703 ppm, and CO yield with ventilation decreases about 29.8% to 57.4%. CO2 yield without ventilation was measured in the range of 1.34% to 2.42%, and CO2 yield was about 44.1% to 53.6% when the emission was more than about 1.5% at 10 minutes. The NOx yield was divided into two cases where the NOx yield was continuously increased because of incomplete combustion, emitted ranging from 29 ppm to 47 ppm, and where emission was constant after 1 minute in the range of 9 ppm to 18 ppm. The NOx yield with ventilation tends to be similar to the without ventilation, and NOx yield decreases up to 62.5%. Therefore, it could be used for health risk assessment with the simulation of the usage environment of charcoal and agglomerated wood charcoal.