• Title/Summary/Keyword: 최대호흡율

Search Result 59, Processing Time 0.022 seconds

Calibration of Activated Sludge Model No. 1 using Maximum Respiration Rate: Maximum Autotrophs Specific Growth Rate (최대 호흡율을 이용한 활성슬러지 모델 No.1 보정: 자가영양균 최대비성장율 추정)

  • Choi, E.H.;Buys, B.;Temmink, H.;Klapwijk, B.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.409-413
    • /
    • 2005
  • A method to estimate the autotrophic maximum specific growth rate is presented in this paper. First of all, the concentration of nitrifier is simulated based on the amount of N nitrified, the sludge age and the default value for the decay coefficient. Secondly the OUR of the sludge with access of ammonia is measured. The maximum specific growth rate can be calculated as ${\mu}_{max,A}\;=\;OUR_{max,A}/Y_A$. It was demonstrated that the maximum specific growth rate of autotrophic biomass is not a constants but a time variable parameter. It is concluded that using $OUR_{max,A}$ for dynamic estimating maximum specific growth rate is a good approach and that using a constant value for the maximum specific growth rate over a longer period of time could not predict the performance of activated sludge plants.

Effect of Light Intensity and Temperature on the Photosynthesis and Respiration of Panax spp (광도와 온도가 인삼의 광합성 및 호흡에 미치는 영향)

  • 이종화
    • Journal of Ginseng Research
    • /
    • v.12 no.1
    • /
    • pp.11-29
    • /
    • 1988
  • This study was conducted to investigate the effect of light intensity and temperature on the photosynthesis and respiration of ginseng plant. Highly significant, second degree curvilinear regressions were recognized among the photosynthesis of ginseng leaves, light intensity and temperature. And an interaction between the effects of light intensity and temperature on the photosynthesis of ginseng leaves was found to be highly significant. The increasing rate of photosynthesis with the increase of light intensity was markedly decreased with increasing temperature. The light compensation point of ginseng leaves was significantly varied with temperature, and the average point was approximately 600 lux. The light saturation point of Korean ginseng was 11,000 lux at $15^{\circ}C$ and $20^{\circ}C$ and around 9,500 lux at above $25^{\circ}C$. The decreasing rate of photosynthesis with the increase of temperature significantly increased with increasing light intensity. The optimum temperature for the photosynthesis of ginseng leaves was about 15 to $22^{\circ}C$ and markedly decreased with increasing light intensity. The highest photosynthesis occurred in ginseng leaves grown with the shade of 15% transmittance. The respiration of ginseng leaves increased with the shade of 5% and/or 30% transmittance. High temperature stimulated the respiration of ginseng leaves. Percent respiration to photosynthesis of ginseng leaves grown with the shade was increased at high temperature and decreased with increasing light Intensity. It was also increased with increasing transmittance. The maximum $CO_2$ absorption of ginseng leaves grown with the shade of 5Ps and ISVS transmittance accurred at 9 o'clock a.m., whereas that of 20% transmittance occurred at 7-9 o'clock a.m. The duration of $CO_2$ absorption was distinctively long with the shade of high transmittance. The $CO_2$ compensation point in the photosynthesis of ginseng leaves was 130 ppm.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Aerobic Capacity and Ventilatory Response During Incremental Exercise in Elite High School Cyclist (점진부하 운동에서 중고교 엘리트 사이클 선수들의 유산소능력과 폐환기 반응)

  • Lee, Dae-Taek;Bae, Yoon-Jung
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.437-443
    • /
    • 2010
  • This study was designed to examine the aerobic capacity and ventilatory response during an incremental exercise in elite high school cyclists. Twelve boys ($17{\pm}1\;yr$, $175{\pm}5\;cm$, $70{\pm}9\;kg$) participated in anthropometric measurements, incremental exercise testing, and pulmonary function tests. During incremental exercise testing using a cycle ergometer, their maximal oxygen uptake ($VO_2max$), maximal power output, ventilation, ventilatory equivalents for oxygen ($V_E/VO_2$) and carbon dioxide ($V_E/VCO_2$), respiratory rate, and tidal volume were measured. Time variables such as inspiratory time (Ti), expiratory time (Te), breathing time (Tb), and inspiratory duty cycle (Ti/Tb), as well as inspiratory flow rate ($V_T$/Ti) were assessed. Pulmonary function of vital capacity (FVC), forced expiratory volume in one second ($FEV_1$), $FEV_1$/FVC, and peak expiratory flow were evaluated. Their $VO_2max$, maximal heart rate, and Wmax were $57.5{\pm}3.9\;ml{\cdot}kg^{-1}{\cdot}min^{-1}$, $194.1{\pm}8.6\;beat{\cdot}min^{-1}$, and 452 W, respectively. $VO_2max$ was not related to any anthropometric parameters. Most ventilatory variables progressively increased with exercise intensity. As intensity increased, Ti, Tb, Tb decreased while Ti/Tb was maintained. Below an intensity of 250 W, height, weight, body mass index, and body surface were highly correlated with $V_T$/Ti and Ti/Tb (p<0.05). Collectively, $VO_2max$ appeared to be lower than adult cyclists, suggesting a different pattern of ventilatory control as age advances. Morphological characteristics were not related to $VO_2max$ in the population. Time variables of ventilatory response seemed to be related only at an exercise intensity level of less than 250 W. $V_T$/Ti may be related to exercise endurance capacity, but Ti/Tb was similar to adult cyclists.

Aerobic Exercise's Influence on Obese Female College Students'Arterial Pulse Wave Velocity, Cardiorespiratory Systems and Body Composition (유산소 운동이 비만 여자대학생의 동맥맥파속도, 호흡순환계 및 신체조성에 미치는 영향)

  • Kim, Seung-Suk
    • Journal of Digital Convergence
    • /
    • v.15 no.7
    • /
    • pp.407-414
    • /
    • 2017
  • In order to identify an Convergence aerobic exercise's influence on obese female college students' Cardiorespiratory systems and arterial pulse wave Velocity, this study targeted female college students in D University in Y-gu, D-City, and selected total 26 ones having body fat percentage over 30% with no special disease in past and at present and no regular physical activity. After finally confirming their participation in this experiment by completely explaining the purpose of and contents of this experiment and getting the subjects' written contents to participate in the experiment, the investigator randomly arranged the subjects into the exercise group(N=13) and the control group(N=13) and conducted a 12-week aerobic exercise program to the exercise group this study got the following conclusion. First, concerning the body composition's change, the exercise group showed significant reduction in the weight, the body fat percentage, and the abdominal fat percentage. Second, for the respiratory & cardiovascular systems'change, the exercise group showed significant increase in the maximal oxygen uptake, the maximal heart rate, and the maximal breathing capacity. Third, for the arterial pulse wave Velocity's change, the exercise group showed significant reduction in the upper body(right and left hands) and lower body (right and left feet).

The Wireless Monitoring System of Respiration Signal (호흡신호 무선 통신 시스템 개발)

  • Son, Byoung-Hee;Jang, Jong-Chan;Yang, Hyo-Sik;Cha, Eun-Jong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.3
    • /
    • pp.157-162
    • /
    • 2011
  • This study is about implementing wireless transferring system in pre-hospital cardiopulmonary resuscitation(CPR). Also, this study includes monitoring based feedback between patient and hospital to increase the survival rate of emergency patient by developing the performance of cardiopulmonary resuscitation in pre-hospital. It minimizes the loss of flow rate or gastric inflation through the space between the airway and the esophagus, which enables the inspiration-expiration rate to be measured more precisely. Due to these reasons this study applied ET insertion based respiratory sensor to measure flow rate. The main indices of artificial ventilation are justified from minute respiration(V), end-tidal $CO_2(E_TCO_2)$, and tracheal pressure($P_{tr}$). The simulation is performed to verify the bandwidth and delay time of transport network for in-hospital monitoring even as transporting images and voice information simultaneously. The total bandwidth is 815 kbps, and WLAN (IEEE 802.11x) is used as communication protocol. The network load is under 1.5% and the transmit delay time is measured under 0.3 seconds.

Physiological rhythms in the Oxygen Consumption and Filtration Rates of the Manila Clam, Ruditapes philippinarum (바지락의 산소비율 및 여수율의 생리적 리듬)

  • 정의영;신윤경;허성범
    • The Korean Journal of Malacology
    • /
    • v.15 no.2
    • /
    • pp.127-131
    • /
    • 1999
  • Changes in Oxygen consumption and filtration rates were investigated to understand physiological rhythms for 24 hours of the Manila clam, Ruditapes philippinarum. physiological rhythms in the oxygen consumption and filtration rates at 15$^{\circ}C$ and 25$^{\circ}C$ were showed diurnal tidal rhythms, appearing two peaks for 24 hours: maximum at night-high tide and minimum at day-low tide. No rapid variations in oxygen consumption and filtration rates for 24 hours appeared at two different water temperatures.

  • PDF

The Difference of Interpretations of Cardiopulmonary Exercise Testing According to Interpretative Algorithms and Exercise Methods (분석 알고리즘과 운동방법에 따른 Exercise Test 결과의 차이)

  • Park, Jae-Min;Kim, Sung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.42-51
    • /
    • 2001
  • Background : Recently, cardiopulmonary exercise testing (CPX) has become a popular diagnostic method for differentiating the main cause of exertional dyspnea or exercise limitation. We evaluated the difference in the CPX results according to interpretative algorithms and the methals of exercise in Korea. Method : Sixty-six patients with chronic lung disease and 48 adults with dyspneic symptoms, but with no abnormalities in a spirometry performed symptom limited CPX, were included in this study. The results were interpreted using both Wasserman's(WA) and Eschenbacher's algorithm (EA), and a comparison between both algorithms was made. Thirty-three healthy medical students performed the CPX with a cycle ergometer and treadmill. The results were interpreted with EA and the concurrence in interpretations was evaluated accord ing to the methods of exercise. Results : 1. In patients with chronic lung disease, the overall concordance rate between the two algorithms was 63.6%. The concordance rates waw 69.8% in patients with obstructive, 25.0% in those with restrictive, and 66.7% in those with mixed pulmonary insufficiency. In patients with dyspneic symptoms but normal findings in resting spirometry, the concordance rate was 60.4%. 2. In healthy medical students, in results inter preted with EA, the concordance rate between the cycle ergometer and treadmill exercise was 25.0%. Conclusion : Both interpretative algorithms and methods of exercise may affect the CPX results. In using CPX as a diagnostic test for the causes of dyspnea in the Korean population. the interpretative algorithms and method of exercise need to be standardized, and a predictive $VO_2$max equation needs to be established.

  • PDF

Effect of $CO_2$ Concentration in CA Conditions on the Quality of Shiitake Mushroom (Lentinus edodes) during Storage (표고버섯(Lentinus edodes)의 CA 저장 중 탄산가스농도의 효과)

  • Kim, Dong-Man;Baek, Hyung-Hee;Yoon, Hye-Hyun;Kim, Kil-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.461-467
    • /
    • 1989
  • The effect of $CO_2$ concentration on the post-harvest physiology and quality of Shiitake mushroom (Lentinus edodes) were investigated during CA storage. The respiratory rates of the mushroom stored in CA conditions were abruptly increased in proportion to $CO_2$ concentration after 40 days, and then declined, while that of the mushroom in air was continuously decreased throughout storage period. Large amounts of ethanol and acetaldehyde were produced from the 20 days CA stored mushrooms. The least changes in 5'-GMP content and electrophoresis pattern of protein in the mushroom were observed at $CO_2$ concentration of 2% during storage. Based on the changes in quality factors of the mushroom during storage, it could be concluded that $CO_2$ concentration of 2% with fixed $O_2$ concentration of 2% was more effective in extension of the freshness than any other $CO_2$ level in this experiment.

  • PDF

The Effect of Sports Elastic Compression Stockings on Lower Extremity Edema by High Intensity Exercise (스포츠용 탄력압박스타킹이 최대 운동 시 하지의 부종에 미치는 영향)

  • Jung, hye-won
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.383-384
    • /
    • 2013
  • 본 연구는 스포츠용 탄력 압박 스타킹(Essential compression calf sleeve, SKINS, Australia)을 착용하고 최대 운동을 하였을 때, 하지 부종에 어떠한 효과가 있는지를 알아보고자 한다. 실험 대상자는 젊은 성인 남녀 30명으로(남자 15명, 여자15명) 근 골격계 및 심혈관계에 특이 병력이나 사고에 의한 외상 등이 없었으며, 규칙적으로 운동을 하는 자는 제외하였다. 대상자들의 신체적 특성을 파악하기 위해서 자동 신장계(BSM330, Biospace, Korea)를 사용하였다. 부종정도를 알기위해서 줄자로 운동 전후의 장딴지 근(종아리)의 둘레와 체성분 분석기(InBody 720, Biospace, Korea)를 사용하여 하지의 부종 수치를 측정하였다. 최대의 운동은 호흡가스 분석기와 연결된 트레이드밀(CPEX-1, IRS, Japan)을 사용하여 변형된 BRUCE Protocol TR-3에 따라 호흡 교환율(R) 값이 1.15이상 되거나 all-out 될 때까지 하였다. 실험 대상자들은 동일 집단으로 전이효과를 방지하기 위하여 일주일의 간격을 두고 스포츠 탄력 압박 스타킹 착용 유무에 따른 동일한 실험을 두 번 하였다. 측정은 최대 운동 전후의 장딴지 근(종아리)의 둘레와 부종 수치를 하였다. 스포츠용 탄력 압박 스타킹 착용 유무와 운동 전후를 비교하기 위하여 MANOVA(다변량 분산분석)를 사용하였고 유의수준은 .05로 설정하였다. 탄력 압박 스타킹을 착용한 상태에서 최대 운동 전후의 부종 정도를 측정한 결과 스타킹을 착용하지 않았을 때 운동 전후의 둘레가 유의하게 증가하였고(p<0.05), 스타킹을 착용 하였을 때 운동 전후의 둘레가 유의하게 증가하지 않았다(p>0.05). 부종 수치(세포외액/전체체액)는 탄력 압박 스타킹을 착용하였을 때 오른쪽 다리는 유의하지 않게 감소하였고(p>0.05), 왼쪽 다리는 유의하게 감소하였다(p>0.05). 탄력 압박 스타킹을 착용하고 운동할 경우 하지의 부종 경감에 어느 정도 효과가 있다고 사료된다.

  • PDF