• Title/Summary/Keyword: 최대유출량

Search Result 432, Processing Time 0.029 seconds

A Case Study of Calculating Flood Inundation Area by HEC-GeoRAS (HEC-GeoRAS 모형에 의한 침수면적산정 사례연구)

  • Kim, Chang-Soo;Lee, Young-Dai;Lee, Hwan-Woo
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.43-48
    • /
    • 2009
  • During the past few years, Korea has experienced extraordinary floods, which have caused many damages of lives and properties. Flooding caused by typhoon is the most common disastrous phenomenon of nature among all catastrophes. As the average temperature of the earth has been increasing by global warming, the possibility of typhoon is also increased by abnormal climate changes. Along with the river improvement as a part of flood control, the time of concentration has been decreased, so the pick discharge has been increased. Moreover, with the land development activities, the area of storage has been diminishing, and the damages from inundation have been continuously increasing. There were a lot of damages to farmland in 1960's, industrial and public facilities in 1970's, and a lot of sufferings from the windstorm in 1980's. In 1990's, however, the amount of damages was increased substantially. So, there is need to decrease the number of the victims and loss of properties by applying preventive measures against natural calamities. This study has employed a simulation system to calculate the depth and amounts of inundation areas to forecast and prevent from flood damage by using rainfall-runoff model. In this study, a case study method is adopted to show inundation by using rainfall-runoff model, HEC-GeoRAS and Arcview. It is hoped that, this study would be conducive to professionals and organizations working in the field of disaster management.

  • PDF

Treatment of highly concentrated organic wastewater by high efficiency $UV/TiO_{2}$ photocatalytic system (고효율 자외선/광촉매 시스템을 이용만 고농도 유기성 폐수처리)

  • Kim, Jung-Kon;Jung, Hyo-Ki;Son, Joo-Young;Kim, Si-Wouk
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.83-89
    • /
    • 2008
  • Food wastewater derived from the three-stage methane fermentation system developed in this lab contained high concentration organic substances. The organic wastewater should be treated through advanced wastewater treatment system to satisfy the "Permissible Pollutant Discharge Standard of Korea". In order to treat the organic wastewater efficiently, several optimum operation conditions of a modified $UV/TiO_{2}$ photocatalytic system have been investigated. In the first process, wastewater was pre-treated with $FeCl_{3}$. The optimum pH and coagulant concentration were 4.0 and 2000mg/L, respectively. Through this process, 52.6% of CODcr was removed. The second process was $UV-TiO_{2}$ photocatalytic reaction. The optimum operation conditions for the system were as follows: UV lamp wavelength, 254 nm; wastewater temperature, $40^{\circ}C$; pH 8.0; and air flow rate, 40L/min, respectively. Through the above two combined processes, 69.7% of T-N and 70.9% of CODcr contained in the wastewater were removed.

Detection of Perchlorate in Nakdong River and Removal Characteristics of Perchlorate by Granular Activated Carbon Process (낙동강 수계에서의 Perchlorate 검출 및 활성탄 공정에 의한 제거특성)

  • Son, Hee-Jong;Jung, Chul-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.438-443
    • /
    • 2007
  • This study was done to investigate perchlorate contamination in Nakdong river. The perchlorate was detected in Nakdong river and ranged from ND to $82.1{\mu}g/L$. The highest concentration was observed in Wheguan. The perchlorate concentration was decreased with the down stream of Nakdong river. Three different virgin activated carbons made of each coal(Calgon), coconut(Samchully) and wood(Picabiol) based activated carbon(AC) were tested for an adsorption performance of perchlorate in a continuous adsorption column. Breakthrough behavior was investigated that the breakthrough points of coal, coconut and wood based AC as 2,300 bed volumn(BV), 719 BV and 288 BV respectively. Adsorption capacity(X/M) of real, coconut and wood based AC was observed. The experimental results of adsorption capacity showed that coal based AC was highest$(768.2{\mu}g/g)$, coconut based AC was intermediate$(299{\mu}g/g)$ and wood based AC was lowest$(99.2{\mu}g/g)$. Moreover, carbon usage rates(CURs) for coal, coconut and wood based AC had been shown as 0.71 g/day, 2.16 g/day and 3.45 g/day respectively. The constant characteristic of the system, k of coal, coconut and wood based ACs were found to be 307.2, 102.5 and 94.2, respectively.

A study of Spatial Multi-Criteria Decision Making for optimal flood defense measures considering regional characteristic (지역특성을 고려한 홍수방어대안 제시를 위한 공간 다기준의사결정 기법 적용 방안 연구)

  • Lee, Eunkyung;Ji, Jungwon;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.301-311
    • /
    • 2018
  • Recently, the flood inundation caused by heavy rainfall in urban area is increasing due to global warming. The variability of climate change is described in the IPCC 5th report (2014). The precipitation pattern and hydrological system is varied by climate change. Since the heavy rainfall surpassed the design capacity of the pipeline, it caused great damage in metropolitan cities such as Seoul and Busan. Inundation in urban area is primarily caused by insufficient sewer capacity and surplus overflow of river. Inundation in urban area with concentrated population is more dangerous than rural and mountains areas, because it is accompanied by human casualties as well as socio-economic damage to recover destruction of roads, brides and underground spaces. In addition, various factors such as an increase in impervious area, a short time of concentration to outlet, and a shortage of sewer capacity's lack increase flooding damage. In this study, flood inundation analysis was conducted for vulnerable areas using XP-SWMM. Also, three structural flood prevention measures such as drainage pipeline construction, detention reservoir construction, and flood pumping station construction are applied as flood damage prevention alternatives. The flood data for each alternative were extracted by dividing the basin by grid. The Spatial Compromise Programming are applied using flood assessment criteria, such as maximum inundation depth, inundation time, and construction cost. The purpose of this study is to reflect the preference of alternatives according to geographical condition even in the same watershed and to select flood defense alternative considering regional characteristics.

Characteristics of Temperature and Salinity observed at the Ieodo Ocean Research Station (이어도 종합해양과학기지에서 관측된 수온과 염분 자료의 특징)

  • Oh, Kyung-Hee;Park, Young-Gyu;Lim, Dong-Il;Jung, Hoi-Soo;Shim, Jae-Seol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.225-234
    • /
    • 2006
  • Using the data from the sea water monitoring system installed at the Ieodo Ocean Research Station, we have analyzed the water properties around the station as well as the characteristics of the fresh water from the Changjiang River and the influence of typhoons on the sea water. In general, the accuracy and stability of the temperature data are high, but those of the salinity data are worse than the specification of the instruments. The daily variation of temperature and salinity is mainly controlled by the vertical motion of a water column due to semi-diurnal tide and diurnal change in the solar insolation. Seasonal change is prominent in temperature data. The freshwater from the Changjiang River is the main cause of large salinity variation. In August 2003 and August 2004, about 10 days before fresh water was observed near the Jeju Island, low salinity water was observed at the Ieodo Station. On the other hand, in July 2005 fresh water was observed at the station but not at around the Jeju Island. In other words, the fresh water observed at the Ieodo Station does not always expand to the Jeju Island. Two strong typhoons passed by the station in September 2003 and August 2004. The effects of the typhoons were lasted for 3 to 4 days.

  • PDF

Odorous Gas Removal in Biofilter with Powdered Activated Carbon and Zeolite Coated Polyurethane Foam (분말활성탄 및 제올라이트 담지 폴리우레탄 담체를 이용한 바이오필터에서의 악취가스 제거)

  • Lee, Soo-Chul;Kim, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.209-215
    • /
    • 2012
  • The performance and removal efficiencies of a pilot scale biofilter were estimated by using ammonia and hydrogen sulfide as the odorous gases. Expanded polyurethane foam coated with powdered activated carbon and zeolite was used as a biofilm supporting medium in the biofilter. Odorous gases from the sludge thickener of a municipal wastewater treatment plant were treated in the biofilter for 10 months and the inlet ammonia and hydrogen sulfide concentrations were 0.1-1.5 and 2-20 ppmv, respectively. The removal efficiencies reached about 100% at the empty bed retention time (EBRT) of 3.6-5 seconds except for the adaptation periods. The pressure drop of the biofilter caused by the gas flow was also low that the maximum attained was 31 mm $H_2O$ during the operation. Its stability was confirmed in the long term due to the fact that the biofilter and the polyurethane medium had a minimum plugging and compression. The microbial community on the medium is critical for the performance of the biofilter especially the distribution of ammonia oxidizing bacteria (AOB) and sulfur oxidizing bacteria (SOB). The distribution of Nitrosomonas sp. (AOB) and Thiobacillus ferroxidans (SOB) was confirmed by FISH (fluorescence in situ hybridization) analysis. The longer the operation time, the more microbial population observed. Also, the medium close to the gas inlet had more microbial population than the medium at the gas outlet of the biofilter.

Analysis of Water Cycle Effect according to Application of LID Techniques (LID 기법 적용에 따른 물순환 효과분석)

  • Lee, Jungmin;Lee, Yun;Choi, Jongsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.411-421
    • /
    • 2014
  • At present, the development in rainwater management approach is still insufficient due to the numerous adverse effects of urbanization. Storm water management is being developed to restore the natural state of water cycle undergoing several processes which were hindered such as infiltration and evapotranspiration. Low Impact Development (LID) was established in order to reduce the negative effects of urbanization to our environment. These developments can be used to respond to the effects of climate change such as heat island phenomenon. The effects of the development of new town in the district plan with application of LID facilities were studied and reported. Typically, LID facilities were applied in small scale development and were rarely used in large-scale development. Most of studies, however, did not assessment the effects of large-scale development projects with LID application to the natural water cycle. This study was conducted to simulate the urban hydrologic cycle simulation on Asan-Tangjeong in Korea. This study may be used in urban hydrologic cycle simulation and establishment of an urban water management plan in the future. Lastly, this study generated a model using the recently updated SWMM5 which determined the hydrologic cycle simulation after installation of LID facilities.

A Study on the Public Evacuation Time Estimates for Radiological Emergency Plan and Preparedness of Wolsong Nuclear Power Plant Site (방사선 비상계획을 위한 월성원전 주변 주민 소개시간 예측 연구)

  • Lee, Gab-Bock;Bang, Sun-Young;Chung, Yang-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.79-88
    • /
    • 2007
  • When an accident occurs at nuclear power plant and radionuclide material is released to the area around the plant, public evacuation is considered as a measure to protect the safety of the residents nearby. This study draws factors required to estimate evacuation time and make estimation of the time to evacuate all residents from the EPZ of Wolsong site in consideration of traffic condition in the neighborhood and on the basis of field data around the site for each factor. The traffic capacity and the traffic volume by season were investigated for the traffic analysis and simulation within EPZ of Wolsong site. As a result, the background traffic volume by season were established. To estimate TGT(Trip Generation Time), the questionnaire surveys were carried out for resident and transient. The TSIS code was applied to traffic analysis in the events of daytime/night and normal/adverse weather under normal day/summer peak traffic condition. The results showed that the evacuation time required for total vehicles to move out from EPZ took generally from 118 to 150 minutes. The evacuation time took longer maximum 17 minutes at night than daytime during summer peak traffic.

반도체 세정액 내 용존 수소 가스가 웨이퍼 세정에 미치는 영향

  • Kim, Hyeok-Min;Gang, Bong-Gyun;Lee, Seung-Ho;Park, Jin-Gu;Choe, Eun-Seok;Kim, In-Jeong;Kim, Bong-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.26.1-26.1
    • /
    • 2009
  • 최근 반도체 세정에 있어서 지난 40년 동안 지속적으로 사용되고 있는 알칼라인 기반의 RCA 세정법은 많은 초순수 및 화학액 소모량과 세정시 불필요한 박막의 손실, 환경적인 문제로 인하여 이를 대체하고자 하는 새로운 새정액 및 세정 방법에 대한 연구가 활발하게 이루어지고 있다. 특히 초순수에 가스를 혼합하여 메가소닉을 이용한 기능수 세정은 기존 RCA 세정액의 문제점들을 해결하기 위한 세정액으로 최근 반도체 제조 공정 뿐만 아니라 Photo mask, FPD 세정 공정에서 널리 이용되고 있다. 하지만 기능수에 대한 기초적인 특성 연구와 메가소닉에 의한 세정력 변화에 대한 연구는 부족한 상태이다. 본 연구에서는 고순도의 수소가스(99.999%)를 가스 접촉기, pHasorII (Entigris, USA) 와 순환 속도의 조절이 가능한 펌프, BPS-3 (Levitronix, USA) 를 이용하여 지속적으로 초순수와 수소가스를 혼합하는 방법으로 수소수를 제조하였으며, 용존 수소 농도계, DHDI-1 (TOA-DKK, Japan)으로 수소수의 농도를 확인하였다. 0.1 MPa 압력과, 3 LPM의 수소가스 유출속도에서 최대 2.0 ppm의 수소수를 얻을 수 있었으며, 수소수의 기초 특성을 평가하기 위하여 수소 농도 변화에 따른 pH, 표면 에너지를 측정하였다. 또한 압력 변화에 따른 반감기를 측정하여 bath형태의 세정기에서 적용 가능성을 평가하였다. 수소수의 세정력은 $Si_3N_4$ 입자가 임의로 오염된 실리콘 웨이퍼를 이용하여 bath 및 매엽식 세정기에서 수소수 농도와 메가소닉 형태 및 첨가제 변화에 따른 세정효율을 기존의 SC-1 세정액과 각각 비교 평가하였다. 기능수 발생장치에서 압력이 제거된 상태에서는 평균 20분의 반감기를 갖는 것이 관찰되었고, 압력이 유지된 상태에서는 수소수의 농도가 유지되는 것을 확인하였으며, pH의 경우 수소수의 농도가 점차 증가함에 따라 감소하여 2.0 ppm의 농도에서 pH 5.3정도의 값을 나타내었다. 표면 장력은 초순수와 비교했을 때 큰 변화가 없음을 확인할 수 있었다. Bath 형태의 세정기에서 메가소닉을 인가하여 수소수의 세정효율을 측정한 결과, 같은 조건에서 실험한 초순수와는 비슷하며, SC-1보다는 낮은 세정효율이 측정되었다. 반면 매엽식 세정기에서 동등한 조건의 실험을 실시한 결과, 수소수 세정에서 첨가제에 의한 영향으로 SC-1을 대체할 수 있는 높은 입자 제거효율을 가짐을 확인할 수 있었다.

  • PDF

Material Properties of Ultra Rapid Hardening Mortar for Repairing Sewage Treatment Concrete Pipes (콘크리트 하수관거 보수용 초속경 수중불분리 모르타르의 재료적 특성)

  • Lee, Byungjae;Lee, Sunmok;Bang, Jin-wook;Kim, Yun-yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • Among the sewage pipes installed in Korea, the length of concrete pipes exceeding 20 years is 66,334 km (42.5%). Deteriorated concrete sewer pipes need to be repaired due to the leakage of internal sewage, which causes problems such as sink holes by expanding the cavity around the pipeline. In this study, we tried to apply anti-washout underwater mortar with ultra rapid hardening cement and segregation reducing agent to sewage pipe repair. As a result of the setting time test, the final set time was delayed by up to 172% by incorporating segregation reducing agent. In the test for measuring the degree of mortar segregation in water, it was measured at pH 12 or less under all mixing conditions. In addition, the suspension amount was measured to be 50 mg / l or less to satisfy the KCI-AD102 standard by incorporating a segregation reducing agent. In terms of the average value of mortar compressive strength, by incorporating segregation reducing agent, the strength of the specimens produced in air was more than 80% of that of the specimens produced in water. Conversely, the bond strengths of the specimens produced in water were measured to be higher than those of the specimens produced in air. Water resistance was evaluated by measuring water absorption and water permeability. Water absorption and water permeability were reduced by 42.6% and 36.6%, respectively, by mixing segregation reducing agent.