• Title/Summary/Keyword: 최대시간지연

Search Result 537, Processing Time 0.031 seconds

Study on Pretreatment Methods to Prevent Tissue Softening of Heated Onion (가열 양파의 조직 연화 방지를 위한 전처리 방법에 관한 연구)

  • Choi, Jun-Bong;Cho, Won-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.56-62
    • /
    • 2015
  • Various pretreatment methods were evaluated to prevent tissue softening of heated onion. Changes in onion tissue firmness during heating were explained by 3-mechanism model consisting of texture hardening at low temperature ($60-80^{\circ}C$) and substrate softening at high temperature. Preheating of onion in a $Ca^{2+}$-containing solution significantly improved its texture after high-temperature heating. The improvement of firmness by preheating at low temperature was related to the formation of strong cross-linking between carboxyl groups and $Ca^{2+}$ by the action of pectin methylesterase in onion. The highest firmness was obtained by pre-heating at $70^{\circ}C$ for 120 min in 0.5% calcium solution. This result was supported by chemical analysis showing that the amount of bound calcium was the highest at $70^{\circ}C$. Further investigation should be carried out to establish the optimal conditions to prevent the softening of various vegetables.

Effect of microwave radiation on physical special quality of normal, high amylose and waxy corn starches (마이크로웨이브를 조사한 옥수수전분의 물리적 특성변화)

  • Lee Su Jin;Choe Yeong Hui
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.15 no.1
    • /
    • pp.113-125
    • /
    • 2004
  • Effect of microwave radiation on physico-chemical properties of cor'n starches was studied. Waxy com, com and high amylose com starches of varying moisture content(20~35%) were subjected to microwave processing(2450MHz) at $120^{\circ}$ and the experimental starch samples were examined by a X-ray diffractometry, rapid viscosity analyzer(RVA) and. with the samples in temperature was observed and the peaks of high amylose com starches at $2^{\circ}$=5.0, 15.0 and $23.0^{\circ}$, were disappeared indicating the melting of crystallines while those of com and waxy com had not changed. A change in gelatinization pattern was observed in the case of corn starches from type A with nearly no peak-viscosity and breakdown to type C. Except a decreased viscosity, no change was observed in those of waxy com starches.

  • PDF

Toxicity Test of butachlor to Medaka (뷰타클로르의 송사리에 대한 독성시험)

  • Park, Yeon-Ki;Kim, Byung-Seok;Shin, Jin-Sup;Bae, Chul-Han;Park, Kyung-Hun;Lee, Jea-Bong;Hong, Soon-Sung;Cho, Kyung-Won;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.4
    • /
    • pp.254-260
    • /
    • 2007
  • In order to evaluate the toxic effects of butachlor, a herbicide widely used for control of weeds in paddy field, on medaka (Oryzias latipes), acute toxicity tests for five developmental stages and early life stage toxicity test of were conducted. As the results of acute toxicity test, $96h-LC_{50}s$ for 1 day, 1 week, 2 weeks, 2 months and 5 months after hatching of O. latipes were 0.68, 0.52, 0.38, 1.09 and $0.45\;mg\;L^{-1}$, respectively. This indicated that the most sensitive stage was 2 weeks after hatching. The early life stage toxicity test showed that no statistically significant hatching period and hatching success of embryo was observed at all concentrations of butaclor. However, 0.05 and $0.1\;mg\;L^{-1}$ of butachlor showed statistically significant post hatching survival with p<0.1. Abnormalities of larva were 2.1, 2.3 and 10% at 0.025, 0.05 and $0.1\;mg\;L^{-1}$ of concentration, respectively. They showed abnormal vertebral axis, craniofacial alteration and retarded yolk-sac resorption. The total length and weight were decreased depending on butachlor concentration the end of test. Weight of larva was showed more sensitive toxic indicator than total length. The toxicological responses of O. latipes to butachlor expressed as LOEC(lowest observed effect concentration), NOEC(no observed effect concentration) and MATC(maximum acceptable toxicant concentration) values were 0.025, 0.013 and $0.018\;mg\;L^{-1}$, respectively.

A Study on the Quality Characteristics of Kimchi with Mulberry Leaf Powder (뽕잎 분말을 첨가한 김치의 품질 특성에 관한 연구)

  • La, Sun-Hwa;Choi, Mi-Kyeong;Shin, Seung-Mee
    • The Korean Journal of Food And Nutrition
    • /
    • v.20 no.1
    • /
    • pp.53-62
    • /
    • 2007
  • In this study, physicochemical, microbiological and organoleptic analyses were carried out on cabbage kimchi, a representative fermented food, that was made with 0.5%, 1.0%, and 1.5% mulberry leaf powder during fermentation. This kimchi was then compared to, kimchi without added mulberry leaf powder. The pH values showed minimal differences between the two types of kimchi at the beginning of fermentation. The total acidities were low in every plot of kimchi and increased according to the fermentation. The total microbial cell and Lactobacilus counts increased rapidly in the exponential phase according to the fermentation, and showed little increase in the stational phase. Among the analyzed plots, the lowest population was found in the kimchi containing 1.0% of mulberry leaf powder. This kimchi, in particular, also had the best quality scores, overall acceptance and organoleptic test results during fermentation. Fermentation was slowed in the kimchi with mulberry leaf powder, according to the amount of added as compared to the kimchi without it also showed less acidity. The color appearance, however, of the kimchi with added mulberry leaf powder, was inferior to that of the kimchi without mulberry leaf powder.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

Current Research Trend of Postharvest Technology for Chrysanthemum (국화 수확 후 관리기술의 최근 연구 동향)

  • Kim, Su-Jeong;Lee, Seung-Koo;Kim, Ki-Sun
    • Korean Journal of Plant Resources
    • /
    • v.25 no.1
    • /
    • pp.156-168
    • /
    • 2012
  • Chrysanthemum is a cut flower species that normally lasts for 1 to 2 weeks, in some cases 3-4 weeks. This has been attributed to low ethylene production during senescence. Reduction in cut flower quality has been attributed to the formation of air embolisms that partially or completely blocks the water transport from the vase solution to the rest of the cut flower stem, increasing hydraulic resistance which may cause severe water stress, yellowing, wilting of leaf, and chlorophyll degradation. Standard type chrysanthemum can be harvested when buds were still tightly closed and then fully opened with the simple bud-opening solution. Standard type chrysanthemum can also be harvested when the minimum size of the inflorescence is about 5-6 cm bud which opened into the first flower full-sized flower. While spray varieties can be harvested when 2-4 most mature flowers have opened (40% opening). Cut flowers are sorted by stem length, weight, condition, and so on. Standard chrysanthemum is 80 cm length for standard type and 70cm for spray type. Pre-treatment with a STS, plant regulator such as GA, BA, 1-MCP, chrysal, germicide, and sucrose, significantly improved the vase life and quality of cut flowers. It is well established that vase solutions containing sugar can improve the vase life of cut chrysanthemum. Chrysanthemum is normally packed in standard horizontal fiberboard boxes. Chrysanthemum should normally be stored at $5{\sim}7^{\circ}C$. Precooling resulted in reduction in respiration, decomposition, and transpiration activities as well as decoloration retardation. There was significant difference between "wet" storage in 3 weeks and "dry" storage in 2 weeks. In separate pulsing solution trials, various germicides were tested, as well as PGRs to maintain the green color of leaves and turgidity. Prolonging vase life was attained with the application of optimal solution such as HQS, $AgNO_3$, GA, BA and sucrose. This also retarded senescence in leaves of cut flower stems. Fresh cut chrysanthemum can be transported using a refrigerated van with $5{\sim}7^{\circ}C$. Increasing consumption and usage of cut chrysanthemum of various cultivars would require efficient transport system, and effective information exchange among producer, wholesaler, and consumer.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.