• Title/Summary/Keyword: 최고선

Search Result 399, Processing Time 0.031 seconds

Studies on the Effects of the Growth Stages of the Rice Plant on the Biological Performance of the Brown Plant hopper, Nilaparvata lugens Stal (벼멸구 생육에 미치는 벼의 생육단계의 영향)

  • Lee Juhn Ho;Hyun Jai Sun
    • Korean journal of applied entomology
    • /
    • v.23 no.1 s.58
    • /
    • pp.49-55
    • /
    • 1984
  • This study was carried out to investigate the biological performance of the brownplanthopper, Nilaparvata lugens Stal, reared on rice plants at different growth stages; maximum tillering, booting, heading with and without panicles, and milking. The results obtained are as follows: The rice plants at the maximum tillering stage gave the best in the longevity, oviposition period, and the total number of oviposited eggs for the macropterous females, and the worst with the booting stage. For the brachypterous females, however, the best results were obtained from the rice of which their panicles had removed after heading. There was no significant difference in the hachability of eggs and the developmental period of the nymphs in the next generation, but the nymphal mortality was the highest with the milking stage and the lowest with the maximum tillering and heading stage without panicles. The longest life span was shown in males derived on the maximum tillering stage, and the shortest for milking(macropterous type) or booting (brachypterous type) stages. Coefficientes of variances in longevity and number of eggs for the adults emerged from heading stage without panicles were lower than those with panicles intact, and such trend was more obvious in brachypterous adults, especially for the females. The biological performances of the BPH have close relationship with the translocated organic material at the feeding site which showed considerable difference with the growth stages of the rice.

  • PDF

A Study on the Highest Exposure Temperatures of Exposed Reinforced Concrete Structures at Fire (화재에 노출된 철근콘크리트 구조물의 최고노출온도 추정을 위한 연구)

  • Kim, Seong Soo;Lee, Jeong Bae;Kim, Il Kon;Song, Jong Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.94-100
    • /
    • 2013
  • In this paper, Machinery analysis was conducted, in order to predict highest exposure temperatures and the analyze fire damage in the case of fire on reinforced concrete structure. After analyzing differential thermal of reference materials in accordance with temperature of concrete reference core specimen, it turned out that powerful endothermic peak came resulting from evaporation of capillary water and get water untill $200^{\circ}C$, another endothermic peak came resulting from decomposition of calcium hydroxide at $520^{\circ}C$, and then mass of reference materials remarkably decreased due to endothermic reaction. Another powerful endothermic reaction came after decomposition of calcite at $720^{\circ}C$. After analyzing X-ray diffraction of reference materials in accordance with temperature of concrete reference core specimen, it turned out that calcium hydroxide existed until the temperature of $400^{\circ}C$, but CH almost disappeared and CaO appeared from $600^{\circ}C$. The production increased in proportion to the temperature. This is because that calcium hydroxide and calcite are decomposed and CaO is produced when the temperature of concrete increases with fire. It is estimated that calcium hydroxide and calcite are utterly decomposed and peak disappears, and peak of CaO is remarkably formed instead, at the temperature of $700-800^{\circ}C$.

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Design of Wideband Facility Power-line EMI filter (광대역 설비용 전원선 EMI 필터의 설계)

  • Chung, Se-Kyo;Lim, Jeong-Gyu;Kim, Mu-Hyun;Kang, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.440-448
    • /
    • 2009
  • Facility power-line electromagnetic interference (EMI) filters are used to provide radio frequency(RF) isolation between dedicated power distribution services and noise sensitive local power distribution systems. This type of EMI filters generally needs a high current capacity and, in some special applications, a high insertion loss of a minimum 100dB from 14kHz through 10GHz per MIL-STD 220 is required. This paper deals with an analysis and design of a wideband facility power-line EMI filter with the above requirements. The characteristics of the inductor and capacitor at high frequencies are investigated. The characteristics and design method of the facility EMI filter with a high order LC network are also presented. The prototype filter is finally implemented and its performance is verified from the experimental results.

Evaluation of Curving Performance and Running Safety of New High-Power Electric Locomotive (신형 고출력 전기기관차의 곡선추종성 및 주행안전성 평가)

  • Ham, Young Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.827-832
    • /
    • 2013
  • In this study, curve responsiveness was assessed based on the lateral force and running safety was evaluated based on the wheel unloading ratio and derailment coefficient, which is the ratio of the wheel load and the lateral force. The evaluation of the curving performance and running safety of the new high-power electric locomotive showed that the derailment coefficient appeared higher when the wheel-set was set to the front of the train instead of being placed backward, and the maximum value of the derailment coefficient was recorded as 0.572 on the Gyeongbu line. Furthermore, the lateral force increased in curved sections, and it appeared to be proportional to the curve radius. Meanwhile, a maximum axis lateral force of 77.6 kN was recorded on the Taebaek line, and the wheel unloading ratio was 47.6% on the Yeongdong line. Finally, the running safety at the maximum speed as well as the through-curve performance of the curve radius satisfied the required standards.

Quantum Dot Sensitized Solar Cell Using PbS/ZnO Nanowires (황화납/산화아연 나노선을 이용한 양자점 감응형 태양전지)

  • Kim, Woo-Seok;Yong, Ki-Jung
    • Clean Technology
    • /
    • v.16 no.4
    • /
    • pp.292-296
    • /
    • 2010
  • We fabricated quantum dot sensitized solar cells(QDSSC) using PbS as a sensitizer and measured the solar energy conversion efficiency. After growing ZnO nanowires on the substrate by low temperature ammonia solution reaction, PbS QDs were deposited on ZnO nanowires by SILAR(Successive ionic layer adsorption and reaction) method. The morphology and crystallinity of PbS/ZnO nanowires were studied by SEM and XRD. In this study, the maximum conversion efficiency of QDSSC using PbS was 0.075% at one sun, which was lower than that of QDSSC using other sensitizers. The reasons it showed relatively low efficiency are i) the probability of type-I band gap arrangement between ZnO and PbS, ii) disturbance of electron migration by the various-sized PbS band gap, iii) stability dip by the chemical reaction of PbS QDs with electrolyte. To solve these problems, researches about controlling the size distribution of PbS and new type electrolyte would be needed.

Processing of Low Salted and Fermented Shrimp Using Gamma Irradiation Before Optimum Fermentation (새우젓 저염화를 위한 최적 숙성직전의 감마선 조사)

  • Ahn, Hyun-Joo;Lee, Cherl-Ho;Lee, Kyong-Haeng;Kim, Jae-Hyun;Cha, Bo-Sook;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1107-1113
    • /
    • 2000
  • Gamma irradiation technology was applied to develop salted and fermented shrimp with lower salt concentration, high sensory quality and storage stability. Shrimp was prepared with 15 and 20% of salt and fermented at $15^{\circ}C$ for 10 weeks. The sample was irradiated at 0, 5.0 and 10.0 kGy right before optimum stage of fermentation. Fermented shrimp with 30% of salt concentration was also prepared as a control. The proximate composition, salinity and Aw were not affected by gamma irradiation. However, pH of irradiated samples was lower than that of non-irradiated samples, probably because irradiation effectively suppressed excessive fermentation by controlling microorganisms. From the results of sensory analysis, it was concluded that fermented shrimp with 15% of salt and irradiated at 10 kGy before optimum fermentation, or 20% of salt and 5 kGy or above were the most effective in terms of sensory quality and storage stability.

  • PDF

Postmortem Degradation of Fish Muscle Proteins 1. Nature of proteolysis and bacterial contribution (어육단백질의 사후분해 1. 단백질분해의 본질과 세균기여)

  • CHUNG Jong Rak;KIM In Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.2
    • /
    • pp.120-128
    • /
    • 1976
  • Two experiments were conducted to study the nature of protein degradation in fish muscle postmortem, first one with English sole (Paraphyrus vetulus) followed by another with rockfish (Sebastodes spp.). In the first one, proteolysis was measured by the increase of amino-N in gutted fish during storage in ice and in the homogenates prepared from fish of different ice storage during $20^{\circ}C-incubation$. In order to test the possible involvement of fish muscle a cathepsin, a portion of each homogenate sample was exposed to 0.5 Mrad of gamma radiation to destroy viable microorganisms prior to the incubation. Proteolysis was not detected until viable count reached a level above $10^7$ cells per gm fish flesh, corresponding to 31 days of ice storage. Even if fish flesh were mechanically disrupted by means of homogenization and subsequently incubated at $20^{\circ}C$, proteloysis attributable to muscle cathepsin was not detected. In the second with rockfish muscle aseptically prepared from freshly killed fish, the samples were inoculated with a proteolytic strain of fish spoilage Pseudomonad or irradiated at 0, 0.5 and 3.0 Mrad. The four samle groups were stored at $0-2^{\circ}C$ to compare the spoilage pattern of sterile and non-sterile muscle. In sterile muscle both total-N (extracted in 0.5M KCl) and amino-N $(soluble\;in\;70\%\;ethanol)$ declined slightly while the inoculated muscle showing increase in parallel with the increase of number of inoculated bacterium. The results indicate that proteolysis is a part of normal fish spoilage and the onset of proteolysis is delayed until viable count reaches its maximum level. Contribution of fish muscle cathepsin to protein degradation in white flesh fish muscle post-mortem is nil.

  • PDF

동해지역의 선상중력자료 처리 및 해면고도계자료와의 비교

  • 최광선;원지훈
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.19-19
    • /
    • 2003
  • 본 연구에서는 국립해양조사원의 '해양2000호'를 통해 1996년과 1997년에 측정한 동해 지역의 중력자료에 대한 자료 처리를 하였다. 효과적인 자료처리를 위해 선상중력자료 처리에 필요한 각종 보정 절차와 문제점 등을 알아보았으며, 선상자료와 해면고도계자료의 비교 및 이를 통한 선상자료의 검증을 실시하였다. 선상중력자료는 측정과 처리 과정에 있어 여러 사항을 고려하여야 한다. 즉, 육상중력기점을 이용한 절대중력으로의 환산 문제, 선박 항해 위치의 부정확성에 기인하는 문제 및 중력계의 기계적 특성과 중력 측정이 이루어질 때의 해상 조건에 의한 영향 등으로 선상중력자료에 나타나는 여러 오차를 최소화하여야 한다. 선상중력자료로부터 각종 지구중력장 연구에 필요한 중력이상을 계산하기 위해 선상중력 측정시 기인되는 각종 요인의 오차를 고려한 효과적인 보정이 이루어져야 한다. 즉, 선상중력계의 기계변이 보정, 탐사선에 대한 위치 자료의 획득 및 필터링, 그리고 탐사선의 이동으로 인한 Eotvos 효과의 정확한 계산 및 보정이 필요하고, 선상중력계의 기계적 특성에 의해 나타나는 시간지연에 대한 보정도 필요하다. 또한 이러한 보정을 통해 계산한 중력 이상에서 각 교점의 오차를 보정하는 교정오차 보정도 실시하여야 한다. 특히, 탐사선의 이동으로 인한 지구자전 각속도의 상대적인 증감의 효과로 나타나는 Eotvos 효과의 영향은 선상중력자료의 정확도에 가장 큰 영향을 미친다. 이의 정확한 계산 및 보정을 위해서는 정확한 위치정보가 필요하며 본 연구에서는 이를 위해 GPS 항해정보에 대한 Kalman 필터를 실시하였고, Eotvos 효과에 대해 Savitzky-Golay 필터를 적용하여 최적의 Eotvos 보정을 시도하였다. 본 연구에서 계산된 동해지역의 중력이상에 대한 대력적인 범위는 경도 129° - 133°이고 위도 35° - 38.3° 부근이다. 이 지역에 대한 고도이상은 최소 -42.46 mGal에서 최고 161.13 mGal사이에 분포하며, 고도이상의 평균은 14.450 mGal이다. 또한 Bouguer 이상은 최소 -l5.09 mGal에서 최고 218.61 mGal이고 이의 평균은 82.681 mGal이다. 그리고 동해지역의 선상중력 측정지역에서 선상자료에 의한 중력이상과 Altimeter 자료에 의한 고도이상의 전반적인 윤곽은 비슷하면서도 일부 작은 이상의 차이가 나타났으며, 지형자료와 비교하여 보면 Altimeter에 의한 결과보다 선상측정에 의한 결과가 더욱 잘 일치하고 있어 본 연구에서 계산한 선상자료의 타당성을 알 수 있다. 고도이상의 차이는 최소 -25.94 mGal에서 최대 85.33 mGal의 차이를 보이며 차이의 평균은 3.517 mGal, RMS는 6.774 meal이다. 이는 비교적 큰 차이로 선상측정자료의 중요성과 필요성을 단적으로 나타내고 있다.

  • PDF