• Title/Summary/Keyword: 촬영 각도

Search Result 1,394, Processing Time 0.029 seconds

Establishment of Optimum Photo Condition for the Accurate Monitoring of Cultural Assets and Ground Facilities using Terrestrial Photographs (문화재와 지상시설물의 정밀점검을 위한 지상사진의 최적촬영조건 설정)

  • 손덕재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.1
    • /
    • pp.1-13
    • /
    • 1994
  • The terrestrial phetogrammetry has the relative convenience of selecting the site of photo station in contrast with the aerial photogrammetry, and the flexibility in accuracy prediction of object point positioning. So it has the advantage in designing optimum photo taking system which can fulfill the required accuracy. For the convergent photos which are frequently used for the monitoring of cultural assets and ground facilities, almost all of the traditional studies for the optimum photo condition, both in theoretical or experimental, are basically depend on the symmetrical configuration at the normal direction to the center of the object. However, in many cases the surroundings of the object do not allow the normal photo direction or sufficient convergent angle, even more the object features are not always be seen as one panel like planar. In this paper, the accuracy variation of convergent photos for the multi-planar objects, which are composed by some orthogonal planes, are investigated to establish the optimum photo condition. The results of the accuracy analysis for the photo direction, convergent angle, as well as the object feature are expected to be utilized in system design of geometric configuration of convergent photos, which are adequate for the accurate monitoring of the objects, such as culural assets, facilities, precision instruments, deformation surveying, etc.

  • PDF

A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection) (Haas 촬영법에서 선예한 영상 획득을 위한 연구)

  • Ahn, Jun-Ho;Han, Jae-Bok;Song, Jong-Nam;Kim, In-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2022
  • The Study In order to obtain a sharpness Image from Skull PA axial projection (Haas) in a head axial X-ray Examination, this study changed the posture angle using Skull Phantom and evaluated the image subjectively to 5 radiologists who worked in the Department of Imaging at University Hospital. In the prone position, the head was lowered 4 cm from the back of the head, entered 25° toward the head, and the image evaluation score was high with 20 points, such as the back bone, dorsum sellae projected in the large hole, and posterior clinoid process. In addition, the score significance was verified, and the Cronbach Alpha value was evaluated to have good reliability of 0.789. As a result of calculating the signal-to-noise ratio (SNR) by setting the region of interest (ROI) of the image, it was the highest at 5.957 for 25° incident at the back of the head and 6.430 for 30° incident at the back of the head. As a result of the study, in order to obtain a sharp image of the back of the head bone, dorsum sellae, and posterior clinoid process when shooting in the axial direction after the head, it is filmed by tilting 25° toward the head from 4 cm below the back of the head. In order to obtain a sharp image of rock pyramid symmetry, petrous ridge, sagittal suture, and lambdoid suture, it is thought that it will be helpful for clinical use if you shoot it 8cm down from the back of the head and tilt it 30° toward the head.

Extraction of 3D Building Information from Monoscopic High Resolution Images (단안식 고해상도 위성영상으로부터 3차원 건물정보 추출연구)

  • Lee, Tae-Yoon;Kim, Tae-Jung
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.23-28
    • /
    • 2005
  • 고해상도 위성영상으로부터 건물, 도로 등의 인공지물의 정보를 추출하기 위한 연구들이 현재 활발히 진행되고 있다. 대부분의 기존 연구들의 경우, 위성영상에서 3차원 건물정보를 추출하기 위해서는 영상과 별도의 기준점을 필요로 하며, 영상에서의 측정값을 3차원 정보로 변환하기 위해서는 센서모델링의 과정을 거쳐야 했다. 이 연구에서는 단안식 (Monoscopic)영상으로부터 이러한 복잡한 과정을 거치지 않고 직접 건물의 3차원 정보를 추출하는 기술개발에 대하여 소개한다. 제안하는 방식은 단안식 영상에서 영상의 방위각 및 촬영지역에서의 태양과 카메라의 방위각 및 고도각을 이용하여 건물의 높이가 주어졌을 때 이에 따르는 건물 수직선과 건물 그림자를 영상에 투영시키는 과정을 반복함으로써 투영된 건물 그림자가 실제 영상에서 관측되는 건물의 그림자와 일치될 대의 건물의 높이 값을 구하고 건물 지붕 외각선을 구해진 건물의 높이 값에 따르는 건물 수식선 만큼 수평 이동하여 건물의 위치를 구하게 된다. 실제 대전지역을 촬영한 IKONS 영상을 이용하여 실험한 결과 이와 같은 방법으로 취득 된 건물 높이값이 약 1m 내외의 정확도를 가지는 것을 나타났다.

  • PDF

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

An Improved Tracking Parameter File Generation Method using Azimuth Fixing Method (방위각 고정 기법을 이용한 개선된 Tracking Parameter File 생성 방법)

  • Jeon, Moon-Jin;Kim, Eunghyun;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.1-6
    • /
    • 2013
  • A LEO satellite transmits recorded images to a ground station using an X-band antenna during contact. The X-band antenna points to the ground station according to a TPF (tracking parameter file) during communication time. A TPF generation software generates azimuth and elevation profile which make the antenna point to the ground station using satellite orbit and attitude information and mission information including recording and downlink operation. When the satellite passes above the ground station, azimuth velocity increases rapidly so that jitter may occur if the azimuth velocity is in specific range. In case of realtime mission in which the satellite perform recording and downlink simultaneously, azimuth velocity must be lower than specific value to prevent image blur due to jitter effect. The method to point one virtual ground station has limitation of azimuth velocity reduction. In this paper, we propose the azimuth fixing method to reduce azimuth velocity of X-band antenna. The experimental results show that azimuth velocity of the X-band antenna is remarkably reduced using proposed method.

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

Object Movie Construction using Images from Multi-Camera (다중 카메라 촬영 영상을 이용한 Object Movie 생성)

  • Choi, Yoo-Joo;You, Hyo-Sun;Song, Chang-Yong;Nam, Yun-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10c
    • /
    • pp.239-242
    • /
    • 2007
  • 본 논문에서는 다수의 저가형 웹캠(Web Cam)으로 촬영된 다각도의 다중 영상을 입력으로 받아 이들을 자연스럽게 연결하여 임의의 각도에서 물체의 모습을 관찰할 수 있도록 하는 ${\ulcorner}$다중 카메라 촬영 영상을 이용한 Object Movie 생성 기반 기술${\lrcorner}$을 제안한다. 기존 Object Movie 생성도구들이 다중의 이미지들을 스티칭(stiching)하기 위해 정확한 카메라의 위치와 방향을 요구하는 데 비해, 제안된 방법은 고가의 트랙장비를 사용하기 어려운 경우에 다수의 저가형 웹캠으로 촬영된 카메라의 위치와 방향을 보정하는 단계를 추가하여 트랙장비를 사용한 것과 같은 매끄러운 영상을 생성할 수 있도록 하였다.

  • PDF

The patient dose calculation model on the Exell program (촬영조건에 의한 환자 피폭선량의 자동계산 프로그램)

  • Kim, Jung-Min;Seok, Jin-Yong
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.35-38
    • /
    • 2002
  • Recently, They are usually recording the patient information on the Hospital Information System. In the department of Radiology, For the purpose of assuming patient exposed dose, Authors contrived the mathematical calculation model by use of x-ray out put data on the Excel program, if they in put the exposure factors (kVp, mAs, thickness), the program could automatically calculate the patient Skin dose. The assuming data by three dimensional equation has average errors within ${\pm}5%$, there for We could make good use of clinical field in department of radiology.

  • PDF

A Suggestion of image capturing position analysis system using Beacon positioning data and camera sensor data (Beacon 측위 데이터와 카메라 센서데이터를 이용한 실내 영상의 촬영 위치 분석 시스템 제안)

  • Jung, SeoKyung;Yoo, Sung-geun;Song, Minjeong;Park, Sang-il
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.11a
    • /
    • pp.145-147
    • /
    • 2018
  • 다수의 일반 카메라로 촬영한 영상들로 360도 영상을 제작하는 경우 다수의 영상 간 동일한 영역을 찾고 기하학 보정을 위한 영상 스티칭 기술이 필요하다. 영상 스티칭 기술은 여러 영상에서 추출한 특징점들의 유사도를 비교하여 영상들을 이어 붙여 큰 하나의 영상으로 만드는 것이다. 본 논문에서는 비콘이 부착된 공연장을 가정하여, 비콘을 통해서 촬영자의 위치를 대략적으로 파악하고, 사용자가 어플리케이션을 통하여 전송한 영상과 영상의 방위각, FOV(Field Of View)들을 이용하여 실내에서 촬영된 영상들을 스티칭 대상 영상들로 필터링하는 방법을 제안한다.

  • PDF

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF