• Title/Summary/Keyword: 촬영지

Search Result 2,117, Processing Time 0.027 seconds

Convergence study related to the development of new clinical training simulator for dental radiography based on augmented reality (증강현실 기반 치과방사선 임상시뮬레이터 개발과 관련된 융합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.161-167
    • /
    • 2018
  • A clinician's skills in a dental clinic are an important factor in removing the risk factors of patients. Although many universities have conducted educational programs, there has been a limitation on repeated practice because of the limited space and equipment. In dental radiography, there are various intraoral radiographic techniques. Since proficiency in radiography is an important factor in obtaining accurate radiographs, repeated practice and skill learning are important at the pre-clinical stage. However, the recent amendment of diagnostic radiation has caused difficulties in repeated practice on the human body. This study aims to develop a clinical simulator for intraoral radiography that enables repeated practice and self-directed learning without any restriction by utilizing the augmented reality technology to foster clinical skills for dental hygienist.

VR Image Shooting Considering Post-Production based Raw Format (원규격 기반 후반작업을 고려한 실사 VR 영상 촬영)

  • Kim, Chulhyun
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.866-875
    • /
    • 2018
  • With the popularity of VR content, actual image based VR 360-degree video production using various shooting devices has attracted attention in recent years. Requiring a lot of work, the existing VR content production was possible only at the level of the research institute, but the recent miniaturization of cameras has made the VR actual image shooting more common to the content creators. In this paper, we compare and study various VR contents distribute in today's context and analyze the strengths and weaknesses of robust actual image-based 360 video production in terms of cost. We are to point out the disadvantages that make it difficult for existing video shooting experts to use and suggest a solution for this. The experiment shooting proved that it can be operated more manually than action cam or integrated camera and 360-degree shooting on a raw format support camera is more suitable for film type post-production.

Combination of Infrared Light Source and Barrier Filter for Suction Bruise Photography (음압에 의해 생성된 멍 촬영을 위한 적외선 광원과 필터 조합에 관한 연구)

  • Kim, Ju-Eun;Kim, Ji-Yeon;Jeon, So-Young;Kim, Eun-A;Yu, Je-Seol
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.693-698
    • /
    • 2016
  • Bruise caused by damages through physical compression and suction is one of evidences that can prove abuse or assault. It is essential for taking photography to prove a crime. Some studies about the Infrared (IR) light source have limitations that only one IR light source and one barrier filter were used. To find the best combination of filters and IR light sources, we produced suction bruise artificially and used three IR light sources and five barrier filters. Consequently, we found that the best combination is using a tungsten lamp and Kodak Wratten #18A barrier filter.

The Effects of Roll Misalignment Errors, Shooting Distance, and Vergence Condition of 3D Camera on 3D Visual Fatigue (시각피로 모형: 카메라의 회전오차, 촬영 거리, 수렴 조건이 입체 시각피로에 미치는 영향)

  • Li, Hyung-Chul O.;Park, JongJin;Kim, ShinWoo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.589-598
    • /
    • 2013
  • In order to understand 3D visual fatigue, it is necessary to examine the visual fatigue induced by camera parameters as well as that induced by a pre-existing 3D content. In the present study, we examined the effects of camera parameters, such as roll misalignment error, shooting distance and vergence condition on 3D visual fatigue and we modelled it. The results indicate that roll misalignment error, shooting distance and vergence condition affect 3D visual fatigue and the effect of roll misalignment error on 3D visual fatigue is evident specifically when screen disparity is relatively small.

Development of Retina Photographing System and 16 Channels Image Acquisition System (망막 촬영 장치 및 16 채널 영상 획득 장치 개발)

  • 양근호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.96-101
    • /
    • 2004
  • In order to measure the retina thickness, there are to need the 3-D retina photographing and the high speed signal processing system. In this paper, we introduced the retina photographing system and the 16-channel high speed image data acquisition system. There are able to measure the retina thickness with sensing image the returned laser signal to APD sensor after there were projected the HeNe laser on retina. We developed the laser projection system to sense a reflected image of the retina using APD sensor, the 16-channel high speed A/D converter and PCI master interface card for image transmission into computer.

A Study on the Performance Evaluation of Broadcasting Shooting Halogen Lights and LED Lights (방송 촬영용 할로겐 조명과 LED 조명의 성능 평가에 관한 연구)

  • Lee, Jang-Weon;Han, Seok-Woo;Im, Ji-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.223-229
    • /
    • 2011
  • In this study, two types of LED spot light with the development of the current broadcast studio-light is installed in the space being used in many products, companies in the UK Arri-650W, 1000W Fresnel spot light and illumination, color temperature and color rendering comparison of data measured compared with the target of the shooting and the color rendition on images was measured by comparing the color. In the future, broadcast - shooting LED spot light replacing whether the available studies on the performance evaluation were analyzed. Experimental evaluation of a replacement for halogen lights in LED Spot light is potential was confirmed.

AI-based Masking Service For Personal Information Protection On Drone-shooting Videos (드론 촬영물에서의 개인정보 보호를 위한 AI 기반 마스킹 서비스)

  • Shin, Dayeon;Kim, Hyoin;Ryu, Hyewon;Lee, Siyoung;Kim, Myungjoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.401-404
    • /
    • 2020
  • 최근 드론 산업은 미래를 이끌어갈 신산업으로 부상하고 있다. 이러한 기대에도 불구하고 드론으로 인해 생기는 여러 문제들 중에서 개인정보침해 관련 문제는 기술적으로 쉽게 풀리지 않아서 드론 사용에 대한 법적인 규제만 더 강화하고 있는 실정이다. 본 논문은 드론 촬영물이 묵시적으로 가지고 있는 개인정보 침해문제를 클라우드 환경 가운데 기술적으로 풀어내었다. 사용자는 자신의 개인정보 침해 요소가 제거된 안전한 영상을 이용할 수 있도록 실시간 촬영 시 특정 사람 객체에 대한 마스킹을 진행할 수 있다. 라즈베리파이 카메라와 드론을 이용해 동영상을 촬영한 뒤 소켓 통신을 통해 이를 클라우드 환경에서의 서버로 전송하면 서버는 실시간으로 마스킹 처리를 진행하며 마스킹이 완료된 영상은 최종적으로 서버에 저장된다. 사용자는 모든 사람 객체 마스킹과 특정인을 제외한 모든 사람 객체 마스킹이라는 두 가지 옵션 중에서 원하는 옵션을 선택하여 개인정보 마스킹 처리를 진행할 수 있다.

Analysis of Chinese Game Cosplay Photography - Focused on 'Qiwei Zoe' - (중국 게임 코스프레(cosplay) 사진 연구 - '칠미조(七味zoe)'를 중심으로-)

  • Jin, Tao;Lee, Sang Eun;Yang, Jong Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.470-478
    • /
    • 2017
  • Costume play is an act of imitating the appearance or behavior of characters in digital games, cartoons or animations. In recent years, cosplay culture has become popular in China as the digital game is made into a movie. The number of cosers has also increased. Especially, Qiwei Zoe has been very popular among cosers because her cosplay photography reflects the understanding of the cosplay culture. A number of cosers admit that her work shows a commercial and artistic potential of cosplay photography. This paper analyzed how she maintains the contents of the original but creatively reimplementing them. She shoots the fantastic image of the character like it really exists in reality so that she can avoid excessive editing work. She emphasizes the character's action that symbolizes its personality and utilizes a variety of outdoor shooting locations similar to the original scenes. We also discussed how cosplay photographers can create cosplay photography by maintaining its artistic features.

Evaluation of Radiation Dose and Image Quality according to CT Table Height (CT 테이블 높이에 따른 방사선 선량 및 화질 평가)

  • Lee, Jongwoong;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.453-458
    • /
    • 2017
  • Computed Tomography (CT) provides information on the Diagnostic Reference Level Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP) for accurate diagnosis of patients. However, it does not provide a dose change according to the table height for the diagnostic reference level provided by the CT equipment. The purpose of this study was to evaluate the image and dose according to the table height change using phantom (PMMA: Polymethyl Methacrylate) in order to find the optimal image and the minimum dose during computed tomography examination. When examining using a 32 cm PMMA phantom with the same thickness as the abdomen of an adult, there was little change in dose with table height. However, the noise evaluation of the image caused a high fluctuation of noise depending on the table height. and in the case of the 16 cm PMMA phantom, the change of the noise was small, but the dose change was about 30%. In conclusion, the location of the patient and the center of the detector are important during computed tomography (CT) examinations. In addition, table height setting is considered to be important for examinations with optimized image and minimum dose.

The Measurement of Helper's Exposure Dose of nearby Radiographic Table in X-ray Examination (X선 촬영시 테이블 주변 촬영도움자의 피폭선량 측정)

  • Eun, Sung-Jong;Kim, Sung-Gil;Min, Byung-Woon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.415-420
    • /
    • 2011
  • The purpose of this study is to know the exposure dose nearby table on the general radiography(skull AP, chest PA, abdomen AP, lumbar lateral, hip joint, knee joint) and to find the reducing it. We measured beside the 45cm and 75cm table center, and 70cm, 80cm, 130cm, 150cm height from the bottom. That were measured highly from the radiography of lumbar lateral, abdomen AP and hip joint as followed $66.21{\mu}Sv$, $34.22{\mu}Sv$, and $32.35{\mu}Sv$ at the 80cm height beside 45cm from the center of table. Measured doses were reduced in order of chest PA, abdomen, hipjoint, skull, knee joint projection. It appears exposure dose of nearby radiographic table was extremely low amount compared with limit of dose(1mSv). If it protected by Pb apron, exposure dose of assisting person will not be exceed a limit of dose. Conclusively, Wearing apron is very important to avoid radiation from the general radiography.