• Title/Summary/Keyword: 촬영기법

Search Result 1,205, Processing Time 0.024 seconds

Generation of 3-Dimensional Landscape Map from Aerial Photos (항공사진을 이용한 3차원 경관도 제작)

  • Yeu, Bock-Mo;Jeong, Soo;Kim, Won-Dae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.3 no.1 s.5
    • /
    • pp.105-113
    • /
    • 1995
  • Three-dimensional landscape map is very useful in terrain analysis as it looks like real shape of terrain. When three-dimensional landscape map is needed, landscape photos achieved at a position of high elevation or by airplane are generally used. But, this approach can not fully satisfy the user's need to get pictures from various view points. In addition, because photos have some geometric displacement caused by the principle of central projection of camera, it is hard to get accurate locations from the photo. This paper aims to get three-dimensional landscape map similar to real terrain feature from vertical stereo aerial photos by digital photogrammetric techniques. This approach can provide a very useful data for three-dimensional terrain analysis as a function of Geo-Spatial Information System.

  • PDF

A Study on Design and Implementation of CAI System for Mammography Education in Radiological Technologist (방사선 유방촬영 교육을 위한 CAI 시스템의 설계 및 구현에 관한 연구)

  • Park Byung-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.78-84
    • /
    • 2005
  • The education system that based on objective data is needed for the beginning technologists in the department of radiology, development of the CAI system based on breast images is needed mammography field. So, in this study, we implemented CAI system based on mammography images for medical radiological technologists under Web using multimedia toolbook. This system is implemented under Web, more and more beginning technologists can have a remote-education beyond time and space, can save human power and time that needed due to hold in common of educational information, and cannot team mistaken breast images because of learning execution based on objective data. Also, implemented system brings a higher interest and a learning effect to medical radiological technologies because of hyper-media method that offered from toolbook. In the future, it will be needed a continuous acceptance of changing knowledge and it will be useful system for technologist in case of applying various examinations based mammography method of this study.

  • PDF

Research of Remote Inspection Method for River Bridge using Sonar and visual system (수중초음파와 광학영상의 하이브리드 시스템을 이용한 교각 수중부 원격점검 기법 연구)

  • Jung, Ju-Yeong;Yoon, Hyuk-Jin;Cho, Hyun-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.330-335
    • /
    • 2017
  • This study applied SONAR(Sound Navigation And Ranging) to the inspection and evaluation of underwater structures. Anactual river bridge was chosen for inspection and evaluation. SONAR and an optical camera were operated together to analyze the underwater image of the bridge. SONAR images were obtained by various methods to remove the environmental variables from the field experiment, and it was confirmed that the reliability of detecting damaged areas on piers was decreased when using SONAR alone. The SONAR equipment and the optical camera can be used simultaneously to overcome the limitations of SONAR in inspecting underwater structures.These results can be used as basic data for the development of similar technologies for underwater structure inspection.

Removal of Ring Artifact in Computed Tomography (전산화단층촬영장치에서 링 아티팩트 제거)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.403-408
    • /
    • 2015
  • Hard X-ray has been widely used in medical and industrial fields because it can be applied to observe the inside of a sample. Computed tomography provides sectional images of the sample through the reconstruction of the projection images. The quality of sectional images strongly depends on that of projection images. Ring artifact appeared on the seconal image can be made by the abnormal pixels of the detector used. In this study, we examine the ring artifact ratio in the circle phantom as a function of detection error of the detector used in computed tomography. The ring artifact increased with the increment of detection error under parallel and fan beam geometries and strongly increased near the center of rotation. The corrections, dead pixel and flat field corrections, for the images taken with the detector are required before the image reconstruction process to reduce the ring artifact in the computed tomography.

Gimbal System Control for Drone for 3D Image (입체영상 촬영을 위한 드론용 짐벌시스템 제어)

  • Kim, Min;Byun, Gi-Sig;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2107-2112
    • /
    • 2016
  • This paper is designed to develop a Gimbal control stabilizer for drones Gimbal system control for drone for 3D image to make sure clean image in the shaking and wavering environments of drone system. The stabilizer is made of tools which support camera modules and IMU(Inertial Measurement Unit) sensor modules follow exact angles, which can brock vibrations outside of the camera modules. It is difficult for the camera modules to get clean image, because of irregular movements and various vibrations produced by flying drones. Moreover, a general PID controller used for the movements of rolling, pitching and yawing in order to control the various vibrations of various frequencies needs often to readjust PID control parameters. Therefore, this paper aims to conduct the Intelligent-PID controller as well as design the Gimbal control stabilizer to get clean images and to improve irregular movements and various vibrations problems referenced above.

Generation and Validation of Finite Element Models of Computed Tomography for Unidirectional Composites Using Supervised Learning-based Segmentation Techniques (지도학습 기반 분할기법을 이용한 단층 촬영된 단방향 복합재료의 유한요소모델 생성 및 검증)

  • Taeyi Kim;Seong-Won Jin;Yeong-Bae Kim;Jae Hyuk Lim;YunHo Kim
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.395-401
    • /
    • 2023
  • In this study, finite element modeling of unidirectional composite materials of the computed tomography (CT) was conducted using a supervised learning-based segmentation technique. Firstly, Micro-CT scan was performed to obtain the raw volume of unidirectional composite materials, providing microstructure information. From the CT volume images, actual microstructure of the cross-section of unidirectional composite materials was extracted by the labeling process. Then, a U-net deep learning model was trained with a small number of raw images as inputs and their labeled images as outputs to generate a segmentation model. Subsequently, most of remaining images were input to the trained U-net deep learning model to segment all raw volume for identifying complex microstructure, which was used for the generation of finite element model. Finally, the fiber volume fraction of the finite element model was compared with that of experimentally measured volume to validate the appropriateness of the proposed method.

전류주입 자기공명영상기법을 이용한 내부 전류밀도 영상에 관한 연구

  • 오석훈;이병일;강현수;우웅제;이수열;조민형
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.115-115
    • /
    • 2001
  • 목적: 인체에 전류를 주입할 때, 내부의 전류밀도 분포는 인체 및 전극의 구조, 주입전류, 그리고 생체조직의 임피던스 분포에 의해 결정된다. 내부의 전류밀도 분포는 전류주입 자기공명영상기법에 의해 영상화할 수 있으며, 자기공명 전기임피던스 단층촬영법과 전자기 치료의 최적화 등에 응용할 수 있다. 본 논문은 3차원 팬텀 내부의 전류밀도 분포를 영상화하는 전류주입 자기공명영상기법의 실험결과를 기술한다.

  • PDF

A Study on The Identification of Blur Parameters from a Motion Blurred Image (모션 블러된 이미지로부터 블러 파라미터를 추출하는 기법에 대한 연구)

  • Yang, Hong-Taek;Hwang, Joo-Yeon;Paik, Doo-Won
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.693-696
    • /
    • 2008
  • Motion blurs are caused by relative motion between the camera and the scene. The blurred image needs to be restored because undesired blur effect degrades the quality of the image. In this paper, we propose a new method for the identification of blur parameters. Experiment shows that the proposed method identifies blur extent regardless of the size of the blur and the object in the original image.

  • PDF

A Study on the Identification of Blur Extent from a Motion Blurred Image (모션 블러된 이미지로부터 블러의 크기를 추출하는 기법에 대한 연구)

  • Hwang, Joo-Yeon;Yang, Hong-Taek;Paik, Doo-Won
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.10
    • /
    • pp.1251-1259
    • /
    • 2007
  • Motion blurs are caused by relative motion between the camera and the scene. The blurred image needs to be restored because undesired blur effect degrades the quality of the image. In this paper, we propose a new method for the identification of blur extent. Experiment shows that the proposed method identifies blur extent regardless of the size of the blur and the object in the original image.

  • PDF