• Title/Summary/Keyword: 총 여과

Search Result 249, Processing Time 0.025 seconds

무산소-호기공정을 이용한 순환식 생물여과반응기에서 동시 질산화 및 탈질화의 특성 연구

  • Lee, Su-Cheol;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.343-346
    • /
    • 2000
  • This study was carried out to investigate the effects of influent $NH_4^{\;+}-N$ load, C/N ratio and superficial air velocity on the nitrogen removal efficiencies. Laboratory scale upflow biological aerated filter(BAF) was consisted of an anoxic-aerobic filter packed with porous ceramic media and operated with synthetic wastewater. BAFs requires less energy and space for the system when compared to conventional activated sludge process. The influent C/N ratios were varied from 0 to 1 by adjusting acetate. Various superficial air velocity had been applied to investigate aeration effect on nitrogen removal. The BAF reactor showed more than 90% average $NH_4^{\;+}-N$ removal efficiencies at $NH_4^{\;+}-N$ loading in the range of $0.26{\sim}1.33$ kg $NH_4^{\;+}-N/m^3{\cdot}d$ and 62% average T-N removal efficiencies at the C/N ratio of 1. Moreover, average T-N removal efficiencies increased as the superficial air velocity increased, because of the increase $NH_4^{\;+}-N$ removal efficiencies.

  • PDF

Study on the Assessment of PAHs Content and Risk Exposure of Convergence Herbal Pills (융합 환제의 PAHs 함량 및 위해성 노출 평가에 대한 연구)

  • Kim, Ga-Yeon;Kim, Hyo-Jin;Lee, Sung Deuk;Lee, Young Ki;Yuk, Young Sam
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.75-84
    • /
    • 2018
  • This study investigated the pollution status of polycyclic aromatic hydrocarbons (PAHs) such as benzopyran, which is a harmful substance, in convergence herbal pills distributed in Seoul. During 2010 ~ 2013, 31 items and 93 samples were collected from the herbal medicines vendors in Seoul, and the samples were extracted, filtered, concentrated, and then spun out with SPE (Sep-pak florisil) and concentrated again and analyzed by liquid chromatography. The results of the analysis showed that the average contents of PAHs were below $10{\mu}g/kg$, and the PAHs were lower than those of daily life exposure, and MOEs was evaluated as safe to a negligible level. In the future, comparative fusion studies on the harmful substances of medicinal pills and food pills are needed.

Total Phosphorus Removal Rate of a Subsurface-Flow Wetland System Constructed on Floodplain During Its Initial Operation Stage (고수부지에 조성한 수질정화 여과습지의 초기운영단계 총인 제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.6
    • /
    • pp.49-55
    • /
    • 2003
  • Total phosphorous removal rate was examined of a subsurface-flow treatment wetland system which was constructed on floodplain in the down reach of the Kwangju Stream in Korea from May to June 2001. Its dimensions were 29 meter in length, 9 meter in width and 0.65 meter in depth. A bottom layer of 45 cm in depth was filled with crushed granite with about 15~30 mm in diameter and a middle layer of 10 cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds(Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju Stream flowed from a submerged dam into it via a pipe by gravity flow and treated effluent was funneled back into the Stream. The number of reed stems increased from 80 stems/$m^2$ in July 2001 to 136 stems/$m^2$ in September 2001. The hight of stems was 44.2 cm in July 2001 and 75.3 cm in September 2001. The establishment of reeds at early operating stage of the system was good. Volume and water quality of inflow and outflow were investigated from July 2001 through December 2001. The average inflow was 40 $m^3$/day and hydraulic detention time was about 1.5 days. The concentration of total phosphorous n influent and effluent was 0.83 and 0.33 mg/L, respectively. The removal rate of total phosphorous averaged about 60%. The removal efficiency was slightly higher, compared with that of subsurface-flow wetlands operating in North America, whose retention rate of total phosphorous was reported to be about 56%. The good abatement rate could be attributed to sedimentation of particle phosphorous in pores of the media and adsorption of phosphorous to the biofilm developed on the surface of them. Increase of standing density of reeds within a few years will develop root zones which may lead to increment in the phosphorous retention rate.

Elimination of Fenitrothion Residues during Dietary Fiber and Bioflavonoid Preparations from Mandarin Orange Peels (밀감과피로부터 식이섬유와 Bioflavonoid 정제 중 Fenitrothion 잔류분의 제거)

  • Kim, Yoon-Kyung;Lee, Mi-Gyung;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.223-229
    • /
    • 1997
  • This study was undertaken in order to elucidate the elimination of fenitrothion residues during the dietary fiber and bioflavonoid preparations from mandarin orange peels. Dietary fibers were prepared from contaminated mandarin orange peels through homogenization, enzyme treatment, ethanol precipitation, acetone washing and air drying, at the yields of 17.4% total dietary fiber, 13.1% insoluble dietary fiber and 1.7% soluble dietary fiber. The removal rate of fenitrothion residues at 13 and 0.5 ppm levels in orange peels was 98.4% and 91.9% in total dietary fiber, 99.7% and 97.1% in insoluble dietary fiber, 100% and 99.6% in soluble dietary fiber, respectively. When bioflavonoid was prepared from contaminated mandarin orange peels through homogenization, soaking, ethanol precipitation, hexane and butanol extractions, the removal rate of fenitrothion residues was 92.7% in intermediate extract and 100% in final extract.

  • PDF

Calibration and Validation of SWAP Model to Estimate the Soil Salinity of Reclaimed Wastewater Irrigation on Paddy Fields (농업용수 재이용에 따른 토양염분 추정를 위한 SWAP 모형의 보정과 검정)

  • Jang, Tae-Il;Sung, Chung-Hyun;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.608-612
    • /
    • 2009
  • 본 연구에서는 하수재이용에 따른 토양에서의 염분변화를 추정하기 위하여 SWAP(Soil-Water-Atmosphere-Plant) 모형을 선정하여 경기도 화성시 수원환경사업소 인근에 위치한 병점지구를 대상으로 모형의 적용성을 분석하였다. 실험에 사용한 관개용수는 1) 지하수(TR#1), 2) 하수처리장 방류수+여과+UV (TR#3)로 분류하여 실험에 사용하였다. 영농기간 동안 논으로 유입되는 총 유입수는 $1,724.2^{\sim}1,733.7$ mm 범위였으며, 이 중 약 64%가 강우에 의해 공급되었고, 나머지는 관개에 의하여 유입되었다. 유입관개수의 EC는 지하수 관개수인 TR#1이 다른 처리구에 비해 작았고, TR#3의 경우 $0.442{\sim}0.698$ dS/cm의 범위를 보였다. 모형의 보정과 검정을 위해서 대상지구에 FDR(Frequency Domain Reflection)을 설치하여 토양수분함유량과 염분농도를 토심에 따라 일단위로 모니터링 하였다. 토양함수량의 보정기간 중 토심별(50, 100, 140 cm) RMSE는 TR#1에서 $0.001^{\sim}0.002$ $cm^3cm^{-3}$, TR#3에서 $0.002^{\sim}0.006$ $cm^3cm^{-3}$으로 나타났으며, 검정기간 중 토심별 RMSE는 TR#1에서 $0.003^{\sim}0.064$ $cm^3cm^{-3}$, TR#3에서 0.001$cm^3cm^{-3}$로 나타났다. 토양염분의 보정기간 중 토심별 RMSE는 TR#1에서 $0.001^{\sim}0.023{\times}10^{-3}$ dS $m^{-1}$, TR#3에서 $0.028^{\sim}0.045{\times}10^{-3}$ dS$m^{-1}$로 나타났으며, 검정기간의 토심별 RMSE는 TR#1에서 $0.018^{\sim}0.037{\times}10^{-3}$ dS$m^{-1}$, TR#3에서 $0.004^{\sim}0.014{\times}10^{-3}$ dS$m^{-1}$로 적용성이 있는 것으로 나타났다.

  • PDF

Development of the Sub-soil Storage System for Utilization Urban Instream Flow of Rainfall Runoff (우수유출수의 도시하천 유지유량 활용을 위한 지하저류시스템 개발)

  • Choi, Gye-Woon;Choi, Jong-Young;Kim, Suk-Dong
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.163-172
    • /
    • 2004
  • In this paper, the sub-soil storage system for utilizing urban instream flow of rainfall runoff was developed and examined through experiments. The artificial rainfall facility and sub-soil storage were installed in the experimental area. The effect of the water qualify improvement and the storage effect were analyzed through the several experiments. Through the experiments of rainfall intensity variation, which are the rainfall intensity of 20mm/hr, 30mm/hr, 40mm/hr, 50mm/hr was indicated SS concentration can be reduction until 68%. Also, the ration of the storage volume is varied from 42.8%∼79.9% based on the rainfall intensity. The reduction rate of the BOD, CO $D_{Mn}$, SS, T-N, T-P was 30%, 42%, 68%, 39%, 26%. As the result, water quality of runoff and efficient of runoff reduction by the system are much improved. The rainfall runoff with the installation of sub-soil storage could be used for instream flow.

Unit Water Production Cost Development for Alternative Water Resource Projects - Centered on the Economics of Aquifer Storage and Recovery (ASR) - (대안수자원시설의 음용수 단위생산비용 산출 - 청정지하저수지 경제성에 대한 고찰 -)

  • Choi, Jae-Ho;Shim, Young-Gyoo;Park, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.611-619
    • /
    • 2017
  • This paper intends to develop unit water production cost (UWPC) between alternative water resources including desalination, freshwater reservoirs, single-purpose dams, underground dams, and two indirect water in-take technologies - riverbank filtration and aquifer storage and recovery (ASR). The UWPCs of water supply schemes including each alternative are determined based on project cost, and operation and maintenance estimation models, which were developed based on real project cost data. The sensitivity analysis of UWPCs reveals that ASR is the lowest cost option in producing drinkable water among the alternatives, followed by riverbank filtration and underground dam. It is expected that economics related to the finding plays a critical role in supporting water resources planning and budget allocation for central and local water authority in Korea.

A Cost-Benefit Analysis of Groundwater: Pumping Wells in Korea (지하수의 경제성 평가 연구: 지하수 관정을 중심으로)

  • Kim, Sun Geun
    • Economic and Environmental Geology
    • /
    • v.47 no.3
    • /
    • pp.219-225
    • /
    • 2014
  • In Korea, there are 1,474 thousand pumping wells nationwide which account for about 12% of total water use in 2012. As much as 39 hundred million tons of groundwater were used while 333 hundred million tons of total water were supplied in 2012. Because the water management authority projects that water demand will exceed supply by 2021, the authority is planning to extensively expand groundwater use in accordance with economic feasibility. Using the basic frameworks of cost-benefit analyses of the World Bank and the US Environmental Protection Agency (US EPA), the objective of this study is to examine the costs and benefits of the expansion of Korea's groundwater extraction through pumping wells. We conclude that the BC ratio of the groundwater pumping wells is 2.98. This signifies that the benefits are 2.98 times higher than the costs. The benefits include use and non-use values of pumping wells while the costs include the installation and maintenance of new wells, in addition to the restoration and pollution costs of abandoned wells, as well as fees for water quality tests, etc.

A Cost-Benefit Analysis of Groundwater Supply through Pumping Well Technology

  • Kim, Sun G.
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2015.11a
    • /
    • pp.479-487
    • /
    • 2015
  • In Korea, there are 1,474 thousand pumping wells nationwide which account for about 12% of total water use in 2012. As much as 39 hundred million tons of groundwater were used while 333 hundred million tons of total water were supplied in 2012. Because the water management authority projects that water demand will exceed supply by 2021, the authority is planning to extensively expand groundwater use in accordance with economic feasibility. Using the basic frameworks of cost-benefit analyses of the World Bank and the US Environmental Protection Agency (US EPA), the objective of this study is to examine the costs and benefits of the expansion of Korea's groundwater extraction through pumping wells. We conclude that the BC ratio of the groundwater pumping wells is 2.98. This signifies that the benefits are 2.98 times higher than the costs. The benefits include use and non-use values of pumping wells while the costs include the installation and maintenance of new wells, in addition to the restoration and pollution costs of abandoned wells, as well as fees for water quality tests, etc.

  • PDF

Studies on The Microbial Utilization of Agricultural Wastes (Part 5) Isolation and Selection of Cellulase Producing Fungi (농산폐자원의 미생물학적 이용에 관한 연구 (제오보) 섬유소분해효소 생산 곰팡이의 분리 및 선별)

  • Bae, Moo;Kim, Byung-Hong;Lee, Gye-Jun
    • Microbiology and Biotechnology Letters
    • /
    • v.4 no.3
    • /
    • pp.105-110
    • /
    • 1976
  • In the studies of microbiological utilization of cellulosic wastes, cellulolytic fungi were isolated and screened out. At the first stage, 221 cellulolytic fungi were isolated from different sources such as soils, humus, composts and rotten wood debris by enrichment culture techniques. In the second stage, 36 strains of fungi out of those previously isolated were selected for their cellulase activities estimated by means of filter paper degradation, carboxy methyl cellulose liquefaction and cup method. Activities of C$_1$-cellulase, C$\sub$x/-cellulase and filter paper activity were adopted on the final screening stage and five different strains which are tentatively identified as Aspergillus sp.(strain No. AS-9), Penicillium sp. (strain No. KNI-1-2), Trichoderma, sp. (strain No. KI-7-2, KI-7-5, KI-4-1-1B) were selected for their high potency of C$_1$ and C$\sub$x/-cellulase activities. When rice straw milled and treated with NH$_4$OH was hydrolyzed with the crude enzyme Prepared from the culture broth of Trichoderma sp. (strain No. KI-4-1-1B), saccharification rate was obtained up to 26%.

  • PDF