• Title/Summary/Keyword: 총휘발성유기화합물 농도

Search Result 25, Processing Time 0.027 seconds

An Experimental Study on the VOCs Concentration Variation using a Petroleum Spill Imitation Trial Test Chamber (원유유출 모의시험 챔버를 이용한 휘발성유기화합물(VOCs)의 농도변화에 관한 연구)

  • Chung, Jin-Do;Lee, Dong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.393-398
    • /
    • 2010
  • This study prepared and utilized an imitation trial test chamber for a petroleum spill to predict the concentration of discharged Volatile Organic Compounds in the air at the time of Tae-An peninsula's petroleum spill, which happened in December, 2007. The petroleum spill imitation trial test chamber measured and analyzed the concentration variation of total VOCs. As the ambient air velocity increased, so the concentration of VOCs decreased; and as the water temperature rose, the concentration of VOCs increased. Furthermore, it appears that total concentration of VOCs decrease by more than 90% 6 days after the initial petroleum spill compared to the initial concentration of VOCs.

중.소규모 조선소 인근 주거지역의 유해대기오염물질 농도 특성

  • Jeong, Jae-U;Park, Eun-Ok;Lee, Myeong-Eun;Mun, Ji-Hun
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.60-62
    • /
    • 2008
  • 중 소규모 조선소의 조업이 주변 지역의 유해대기오염물질 농도에 미치는 영향을 평가하고자 주변 지역에 미치는 환경영향을 클 것으로 예측되는 조사지점을 선정하여 휘발성유기화합물 및 알데히드류의 분석을 수행하였다. 총휘발성유기화합물(TVOCs) 농도는 조선소와 거리가 가까울수록 높은 것으로 나타났으며 주요 VOC 성분은 조선소 도장작업장에서 분석되는 성분과 일치하는 것으로 나타나 조선소에서 이루어지는 도장작업으로 인해 주변지역이 영향을 받음을 알 수 있었다. 알데히드류의 경우, 발생원으로부터 직접 배출되기보다는 배출된 VOC의 화학반응에 의해 생성되므로 조선소에 가까이 위치한 지점들보다 조선소로부터 일정한 거리가 떨어져 있는 지점의 농도가 높게 나타나는 것으로 나타났다.

  • PDF

Reduction Effect of VOCs and Formaldehyde Using Auto Bake-Out System (자동 베이크 아웃 시스템을 이용한 휘발성유기화합물 및 포름알데히드 저감효과)

  • Kim, Hyung-Jin;Lee, Kap-Soo;Cho, Jin-Kyu;Lee, Jun-Bum;Roh, Heoung-Rae;Yun, Hong-Su
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.291-295
    • /
    • 2011
  • A bake-out process using auto switchgear for five days was performed to evaluate the reduction effect of the concentration of volatile organic compounds (VOCs) and formaldehyde in a newly-built elementary school gymnasium. Reduction rates of VOCs were observed as followings: 38.2, 64.2, 86.3, 80.2, and 71.5% for benzene, toluene, ethylbenzene, xylene, and styrene, respectively, which satisfies the indoor air quality standards of newly-built apartment houses in Korea. The reduction rate of total VOCs and formaldehyde were 67.0 and 24.7%, respectively. Those results proved that the bake-out process using auto switchgear was effective for reducing indoor air pollutants.

Indoor Air Quality in daycare facilities (보육시설의 실내공기질 유지관리 실태)

  • Park, Jun-Seok
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.28-32
    • /
    • 2014
  • 본 투고에서는 2008년 환경부의 용역으로 실시된 "보육시설의 실내공기질 진단 및 개선 시범사업"의 결과를 바탕으로 우리나라 보육시설의 실내공기 오염 실태와 함께 개선방안, 그리고 개선효과에 대하여 소개하였다. 서울, 경기, 인천 지역의 61개 시설을 대상으로 실내공기질 측정과 설문조사를 실시한 결과 폼알데하이드와 총 휘발성유기화합물은 일부시설에서 "다중이용시설 등의 실내공기질 관리법" 기준치를 초과하는 것으로 나타났다. 반면 이산화탄소와 미세먼지는 조사 대상 시설 중 50 % 이상이 기준치를 초과하는 것으로 나타났다. 따라서 보육시설의 실내공기질 개선을 위해서는 각 오염물질의 발생원별로 유지관리 대책이 필요한 것으로 조사되었다. 또한 오염원인별 분석결과, 대부분 시설의 실외오염물질 농도가 실내보다 낮게 나타나 외기의 오염이 실내에 미치는 영향은 미비한 것으로 나타났으며, 계절에 따른 실내공기오염은 동절기에 낮은 외기온도로 인하여 실내를 하기 때문에 하절기에 비해 더 높게 나타났다. 공간에 따른 오염물질의 농도는 이산화탄소와 미세먼지의 경우 아동이 늘 상주하는 교실의 오염이 가장 심한 것으로 나타났으며 폼알데하이드와 총휘발성유기화합물의 경우 놀이실의 오염도가 교실에 비해 더 높게 나타났다. 개선방안별 개선효과에 있어서는 환기계획 몇 환기설비 설치, 지하공간 습기 문제 개선에서 가장 높은 효과가 나타났다. 향후 보육시설의 쾌적하고 건겅한 실내환경의 유지관리를 위해서는 보육종사자들이 활용할 수 있는 유지관리 지침 또는 매누얼에 대한 보급이 필요할 것으로 판단된다.

The Concentration Ascension of Volatile Organic Compounds after Remodeling in Apartment Houses (아파트 리모델링 전.후의 휘발성유기화합물 농도 변화)

  • Choi, Yoon-Jung;Shin, Hae-Chul;Shim, Hyun-Suk
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.287-290
    • /
    • 2006
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after remodeling in apartment houses and to analyze the relation of concentrated ascension and remodeling elements. The field measurements of TVOC and HCHO concentration were carried out in 4 subject apartment houses according to the Korea Test Method Standard for Indoor Air Quality. The results are as follows; the TVOC concentration after remodeling ranged from mean 0.35ppm to mean 5.08ppm and increased of 0.35$^{\sim}$5.08ppm. The concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.7ppm). The HCHO concentration after remodeling ranged from mean 0.13ppm to mean 0.43ppm and increased of 0.06$^{\sim}$0.26ppm. The concentration of 2 subjects exceeded the Standard (0.16ppm). As results of analysis on the relation of concentrated ascension and remodeling elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

  • PDF

The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory (대학교 신축기숙사의 휘발성유기화합물 농도 및 새집증후군 반응)

  • Choi, Yoon-Jung;Kim, Jung-Jae;Jang, Yoon-Jeong;Oh, Ye-Seul
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.255-260
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor air quality by TVOC concentration and residents' responses and to analyze the influencing factors of IAQ in newly built university dormitory. The field measurements on the levels of TVOC and HCHO were carried out three times at an interval of 4 weeks in 3 rooms of a dormitory. The questionnaire survey on the residents that inquired into the lifestyle, the consciousness related to IAQ, and the responses of SHS was fulfilled. According to the results, the level of TVOC was approximately $0.14{\sim}18.5ppm$ and HCHO was $0.23{\sim}6.89ppm$ during 3 month since construction completion, which are seriously in excess of standard level, and seemed to be on the decrease as time goes by. The factors influencing the differences of the levels of TVOC or HCHO were the amount of ventilation including infiltration, heating temperature, relative humidity, or the use of living things including chemical. However, the residents rarely felt the responses of SHS and did not be conscious of the importance of ventilation.

  • PDF

Actual State of TVOC and HCHO Concentration in Newly Built or Remodeled Kindergarten (신축 및 리모델링 유치원의 휘발성유기화합물 농도 실태)

  • Choi, Yoon-Jung;Park, Eun-Bi;An, Ji-Sun
    • Korean Journal of Human Ecology
    • /
    • v.18 no.6
    • /
    • pp.1363-1374
    • /
    • 2009
  • The purpose of this study was to determine the actual state of the indoor air quality in newly built or remodeled kindergartens by TVOC and HCHO concentration and teachers' responses. The field measurements on the levels of TVOC and HCHO were carried out in six classrooms of newly built or remodeled kindergartens before their opening. The interviews with teachers of subject kindergartens were carried out at the end of the first semester. The contents of the interviews were teachers' subjective responses and symptoms of the kindergarten pupils on the Sick New-School Syndrome. The results are as follows; the mean value of TVOC concentration in the classrooms of kindergartens ranged from 0.10ppm to 0.42ppm, which can theoretically exert a harmful influence on residents. The mean value of HCHO concentration ranged from 0.00ppm to 0.03ppm, which does not exceed the standard. The TVOC concentrations of the more ventilated kindergartens were lower than the others. Also, the classrooms with high concentrations of TVOC showed negative responses or symptoms in teachers and kindergarten pupils.

The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory (대학교 신축 기숙사의 휘발성유기화합물 농도 및 새집증후군 반응)

  • Choi, Yoon-Jung;Oh, Ye-Seul;Jang, Yoon-Jeong;Kim, Jung-Jae
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.135-143
    • /
    • 2009
  • The purposes of this study were to determine the actual state of the indoor air quality by measuring TVOC Concentration and surveying residents' responses in a newly built university dormitory and to analyze the influencing factors of IAQ. Field measurements on the concentrations of TVOC and HCHO were carried out three times at 4 week intervals in 3 rooms of a dormitory. A questionnaire survey was conducted on residents which inquired into the resident's lifestyle, their consciousness of IAQ, and the responses to SHS. According to the results, TVOC concentrations were 0.14~18.5 ppm and HCHO concentrations were 0.23~6.89 ppm during the 3 months following the completion of construction, showing a serious state in which standard levels are exceeded, though these levels seemed to decrease over time. The factors influencing the differences in the levels of TVOC and HCHO were the ventilation volume including infiltration, the heating temperature, relative humidity, or the use of living matter that include chemical ingredients. However, the residents rarely felt the symptoms of SHS and were not conscious of the importance of ventilation.

The Detection of VOCs in Effluents from Several Wastewater Treatment Plants and Industry Drains in Nakdong River Basin (낙동강 유역 일부 폐수처리장 방류수 및 공단배수로의 휘발성유기화합물(VOCs)의 분포현황)

  • Bae, Hun-Kyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.254-259
    • /
    • 2012
  • The discharge characteristics of Volatile Organic Compounds (VOCs) from seven wastewater treatment plants and two industry drains at Nakdong River basin were investigated. Four Sampling campaigns were conducted between May 2008 and November 2008, and tested for 17 VOCs. As results, eight VOCs were detected at some sampling sites, but their concentration levels were low; 0.19~3.41 ${\mu}g/L$, dependent on each sampling location and substance. However, proper management plans such as supervising and monitoring systems for VOCs are needed to control those pollutants since VOCs might affect human health as well as aquatic ecosystems with extremely low concentration levels.

The Concentration Variation of Volatile Organic Compounds before and after Renovation in Apartment Houses (아파트 개조 전후의 휘발성유기화합물 농도변화 실태)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Shin, Hae-Chul
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.59-67
    • /
    • 2007
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after renovation in apartment houses. The field measurements of TVOC and HCHO concentration according to the Korea Test Method Standard for Indoor Air Quality were carried out in 4 subject apartment houses. The results are as follows; the TVOC concentration after renovation in apartment houses ranged from mean 0.35ppm to mean 5.08ppm and increased of $0.35{\sim}5.08ppm$. The TVOC concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.58ppm). The HCHO concentration after renovation ranged from mean 0.13ppm to mean 0.43ppm and increased of $0.06{\sim}0.26ppm$. The HCHO concentration of 2 subjects exceeded the Standard (0.17ppm). As results of analysis on the relation of concentrated ascension and renovation elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.