• Title/Summary/Keyword: 총열전달계수

검색결과 9건 처리시간 0.032초

연도가스 열회수용 순환유동층 열교환기의 오염저감특성 (Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery)

  • 이금배;전용두
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

낮은 핀을 가진 경사 써모사이폰의 열전달 성능에 관한 실험적 연구 (Experimental study on heat transfer inside inclined thermosyphon with low integral-fins)

  • 조동현;권혁홍
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.165-172
    • /
    • 1998
  • An experimental study on the heat transfer of the inclined thermosyphon with low integral-fins in which boiling and condensation occurred is performed to investigate its heat transfer performance. Water and CFC-30 have been used as the working fluids. The operating temperature and the inclination angle of thermosyphon have been used as the experimental parameters. The heat flux input and the inclination angle $\theta$ towards the vertical position were varied in steps. The heat transfer rate in the thermosyphon was depended upon the inclination angle. In addition, it is to obtain the overall heat transfer coefficients and the characteristics as a operating temperature for the practical applications.

  • PDF

냉각수로 하천수를 이용하는 열교환 시스템내 Fouling 형성에 관한 연구 (A Study on the Formation of Fouling in a Heat Exchanging System for HAN-River Water as Cooling Water)

  • 성순경;서상호;노형운;조영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1473-1478
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanger surface, it is traditionally called fouling. The objective of the present study is to investigate the formation of fouling in a heat exchanging system. A lab-scale heat exchanging system is built-up to observe and measure the formation of fouling experimentally. Water analyses are conducted to obtain the properties of HAN river water. In the present study a microscopic observation is conducted to visualize the process of scale formation. Hardness of HAN-river water is higher than that of tap water in Seoul.

  • PDF

축방향 내부 핀을 가진 열사이폰의 작동유체 체적변화에 대한 열전달 성능에 관한 연구 (A Study on the Performance of the Heat Transfer for the Liquid Filling as the Ratio of Working Fluid Volume to Total Volume of the Thermosyphon with Axial Internal Fins)

  • 이정한;이기백;조동현
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.23-30
    • /
    • 2002
  • 본 연구는 축방향 내부 핀을 가진 열사이폰의 작동유체의 체적변화에 대한 응축 및 비등열전달 성능에 관한 연구이다. 열사이폰 내부의 작동유체는 증류수를 사용하였다. 열사이폰의 총체적에 대한 작동유체의 양을 변화시키면서 실험데이터를 산출하였다. 열사이폰의 응축부에 대한 열유속과 응축열전달계수를 구하였으며, 실험결과를 이론모델과 비교분석하였다. 실험결과로부터 열사이폰의 열전달 성능은 작동유체의 체적변화에 크게 의존하였다. 축방향내부 핀을 가진 열사이폰의 열전달 성능은 평튜브로 제작한 열 사이폰보다 크게 향상되었다. 이와 같은 열사이폰을 태양열 분야의 열교환기에 응용할 경우, 고성능화와 소형화할 수 있다. 그리고 산업현장에서 실제적으로 적용하기 위해 총열전달계수를 산출하였다.

열교환기 모델내 하천수와 시수의 Fouling 특성 비교 (A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model)

  • 성순경;서상호;노형운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

연직 원통윈에서의 혼합대류-전도 복합열전달에 미치는 복사효과 (Radative Effect on the Conjugate Mixed Convection-Conduction Heat Transfer along a Vertical Circular Cylindrical Fin)

  • 최상경;여문수;손병진
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1706-1716
    • /
    • 1991
  • 본 연구에서는 혼합대류하는 연직원통휜 열전달에 미치는 복사효과에 Rossel- and 근사해법을 도입한 층류 경계층방정식과 휜 전도방정식을 동시에 해석하여 복사 -전도매개변수(radiation-conduction parameter) M, 대류-전도 매개변수(convectionc- onduction parameter) N$_{c}$, 부력매개변수(buoyancy force parameter) R$_{i}$ 그 리고 횡곡률 매개변수(transverse curvature parameter) .lambda.를 계산 파라미터로 하여 휜 최적설계의 기본이 되는 총열전단률, 무차원 국소등가열전달계수, 무차원 국소열플 럭스 및 휜온도분포를 계산할 수 있는 일반성있는 algorithm을 개발하고 휜 성능에 관 한 결과들을 제공함으로써, 좀 더 완전한 복사 열플럭스를 도입한, 다음 연구를 위한 범용의 기초자료를 얻는데 본 연구의 목적이 있다.

열펌프 성능향상을 위한 공기 열교환기 특성 (Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP)

  • 노정근;송현갑;박용규
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2002년도 동계 학술대회 논문집
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

Rock-pile식(式) 집열기(集熱器)를 이용(利用)한 농산물건조(農産物乾燥)에 관(關)한 연구(硏究) (Drying of Agricultural Products by the Flat-plate Solar Collector with Rock-piled Heat Storage Medium)

  • 장규섭;김만수
    • Applied Biological Chemistry
    • /
    • 제26권2호
    • /
    • pp.75-81
    • /
    • 1983
  • 태양열(太陽熱) 축열장치(蓄熱裝置)의 개발(開發)을 위(爲)한 기초자료(基礎資料)를 얻기 위(爲)하여 태양열(太陽熱)의 축열매체(蓄熱媒體)로 돌을 이용(利用)한 평판집열기(平板集熱器)을 제작(製作)하여 집열기(集熱器)의 효율(效率), 총열전달계수(總熱傳達係數), 집열기(集熱器)에 의(依)한 상승온도등(上昇溫度等)을 분석(分析)하고 이를 열원(熱源)으로 벼와 고추에 대(對)한 건조실험(乾燥實驗)을 하였다. 초기함수율(初期含水率) 24.5%인 벼를 14.5%까지 건조(乾燥)시키는데 상온통풍건조(常溫通風乾燥)에서는 약(約) 18일(18日), 튜브형집열기(型集熱器)에서 약(約) 12일(12日), 평판집열기(平板集熱器)에서 약(約) 10일(10日)이 소요(所要)되었으며 통고추 건조(乾燥)의 경우 일광건조(日光乾燥)에서 약(約) 68시간(68時間), 튜브형집열기(型集熱器)에서 약(約) 38시간(38時間), 평판집열기(平板集熱器)에서 약(約) 36시간(36時間)이 소요(所要)되었다. 고추를 절단(切斷)하여 건조(乾燥)할 경우 수평(水平)으로 절단(切斷)하는 것이 효과적(效果的)이었으며 건조(乾燥) 과정중(過程中) capsanthine과 capsaicine성분(成分)의 변화(變化)는 건조방법(乾燥方法)이나 절단방법(切斷方法)에 따라 고추의 품질(品質)에 영향(影響)을 미치는 정도(程度)는 아니라고 사료(思料)되었다.

  • PDF

농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究) (Development of Solar Warehouse for Drying and Storing the Agricultural Products)

  • 김만수;장규섭;김성래;전병선
    • 농업과학연구
    • /
    • 제9권1호
    • /
    • pp.357-370
    • /
    • 1982
  • 태양열(太陽熱)을 이용(利用)한 곡물(穀物)의 건조(乾燥)와 저장(貯藏)을 겸할 수 있는 농가용(農家用) 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 필요(必要)한 기초자료(基礎資料)를 얻기 위(爲)하여 구조(構造)가 간단(簡單)하고 가격(價格)이 저렴한 콘크리트 벽체의 저장고(貯藏庫)와 그 지붕을 대신(代身)한 태양열집열기(太陽熱集熱器)를 설계(設計) 제작(製作)하여 집열기(集熱器)의 성능(性能)을 실험(實驗)에 의(依)하여 구(求)하였으며 집열기(集熱器)에서 가열(加熱)된 공기(空氣)와 상온통풍(常溫通風)에 의(依)한 벼의 건조특성(乾操特性)을 비교(比較) 분석(分析)하였다. 건조(乾操)된 곡물(穀物)의 저장시(貯藏時)에 그 온도(溫度)를 예측(豫測)할 수 있는 simulation model을 개발(開發)하여 그 적합성(適合性)을 검정(檢定)하고 저장곡물(貯藏殺物)의 각(各) 부위(部位)에 대(對)한 온도(溫度)의 변화(變化)를 분석(分析)한 결과(結果)들을 요약(要約)하면 다음과 같다. 1. 본(本) 실험(實驗)에 설계(設計) 제작(製作)된 태양열집열기(太陽熱集熱器)의 효율(效率)은 평균(平均) 26%였으며 총열전달계수(總熱傳達係數)는 약(約) $25kJ/hr.m^2\;^{\circ}K$였다. 2. 태양열(太陽熱)을 이용(利用)한 건조(乾燥)에서는 공시(供試)벼의 함수율(含水率) 23.5%에서 15.0%까지 건조(乾燥)시키는데 7일(日)이 소요(所要)되었으며 상온통풍건조(常溫通風乾燥)에서는 함수율(含水率) 20.0%에서 15.5%까지 건조(乾燥)시키는데 12일(日)이 소요(所要)되었다. 3. 건조소요시간(乾燥所要時間)은 태양열(太陽熱)을 이용(利用)한 건조(乾燥)가 배(倍) 정도(程度) 빠르나 하층부(下層部)의 곡물(穀物)의 과건현상(過乾現象)의 방지책(防止策)이 철저히 구명(究明)되어야 할 것이다. 4. 저장곡물(貯藏殺物)의 온도(溫度)를 예측(豫測)할 수 있는 simulation model을 finite difference method에 의(依)해 개발(開發)하였으며 검정(檢定) 결과(結果) 실측치(實測値)와 잘 일치(一致)되었다. 5. 저장곡물(貯藏殺物)의 온도(溫度) 변화(變化)는 벽체와 접촉(接觸)하고 있는 부위(部位)에서 컸으며 곡물(穀物)의 손상(損傷)도 이곳에서 심(甚)할 것으로 사료(思料)된다.

  • PDF