• Title/Summary/Keyword: 촉진내구성시험

Search Result 61, Processing Time 0.026 seconds

Corrosion Prediction of a Cement Mortar-Grouted Rockbolt by Measuring Its Chloride Diffusion Coefficient (시멘트 모르타르계 록볼트 충전재의 염화물 확산계수 측정을 통한 록볼트 부식 예측)

  • Bae, Gyu-Jin;Chang, Soo-Ho;Kim, Dong-Gyou;Park, Hae-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.3
    • /
    • pp.259-271
    • /
    • 2006
  • This paper aims to predict the corrosion of a fully cement-grouted rockbolt induced by chloride diffusion in a cement mortar grout. From the viewpoint of the long-term durability, a rockbolt may be deteriorated by chemical components, such as sulphate and chloride, in groundwater. Especially, the steel rod of a rockbolt is corroded mainly by chloride. The rockbolt corrosion results in the volume expansion of a rod and then the cracking of a cement grout. In this study, the chloride diffusion coefficient of a cement mortar grout was used to evaluate the possibility of rockbolt corrosion by chloride, and to predict the long-term durability of a rockbolt. The electric acceleration test method was adopted to measure the chloride diffusion coefficient. In addition, a simple pullout testing system was newly proposed to measure the pullout capacity of a rockbolt more easily in a laboratory condition. From the experiments, it was showed that the chloride could diffuse in the cement grout more easily than in ordinary concrete materials. As a result, it was considered that a rockbolt might be easily corroded in a short term by the diffusion of chemical components with high concentration, although it was fully grouted.

Evaluating the Durability of Concrete Combined with Ground Granulated Blast Furnace Slag using Electrolysis Alkaline Aqueous as Mixing Water (전기분해 알칼리수를 배합수로 사용한 고로슬래그 미분말 혼입 콘크리트의 내구성)

  • Jeong, Su-Mi;Kim, Ju-Sung;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.4
    • /
    • pp.349-358
    • /
    • 2023
  • This research aimed to enhance the initial strength of concrete that is mixed with ground granulated blast furnace slag, as well as to fortify its resistance to carbonation and chloride ion permeation. To achieve this, alkaline aqueous, produced through the electrolysis of potassium carbonate, was employed as the mixing water in the preparation of concrete. To substantiate the increment in initial strength, compressive strength measurements of the concrete were executed. Additionally, an accelerated carbonation test and a chloride ion permeation resistance test were undertaken. The results confirmed that the initial strength of the concrete, which utilized electrolysis alkaline aqueous as mixing water, exhibited an improvement in comparison to concrete mixed with conventional water. It was also verified that both carbonation resistance and chloride ion permeation resistance showed enhancements.

Influence of Carbonation of Concrete on Electrical Resistivity (콘크리트의 탄산화가 전기저항에 미치는 영향)

  • Yoon, In-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.27-33
    • /
    • 2014
  • Electrical resistivity of concrete can be measured in a more rapid and simple way for estimating durability of the concrete, however, carbonation causes a result of misleading for durability testing because carbonation leads to a significant reduction in the permeability and porosity of concrete. The purpose of this study is to estimate and quantify the effect of carbonation of concrete on a surface electrical resistivity measurement. Samples of three mixes with difference w/c were prepared and exposed in a carbonation chamber for 330 days. The results show that carbonation leads high electrical resistivity. The increase is substantial and has been shown to proportional to the extent of the carbonation by some of extent. The relationship between electrical resistivity and carbonation depth is taken in the study. Resistivity ratio of carbonated concrete to air concrete decreased significantly from the specific carbonation depth, however, resistivity ratio of carbonated concrete to air concrete had a linear relation with carbonation depth. From the relationship between electrical resistivity and carbonation depth, it is expected that the result should be subsequently used as a calibration curve for estimating carbonated concrete to overcome the interruption effect of carbonation on regular measurements of the electrical resistivity.

A Study on the Application of FRP Hybrid Bar to Prevent Corrosion of Reinforcing Bar in Concrete Structure (콘크리트구조물 중의 철근 부식 저감을 위한 FRP Hybrid Bar의 적용성 연구)

  • Lee, Seung-Tae;Park, Kwang-Pil;Park, Ki-Tae;You, Young-Jun;Seo, Dong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.559-568
    • /
    • 2019
  • Recently, the infrastructure of the marine environment has been increasing. Therefore, there has been increasing interest in increasing the durability of structures. The FRP Hybrid Bar with improved durability against corrosion was developed in recent years. On the other hand, studies that evaluate the corrosion resistance are insufficient. In this study, the corrosion resistance according to the type of rebar in concrete was assessed and analyzed. The experiment used steel bars and FRP Hybrid Bar. The corrosion test method was a galvanic current and half-cell potential method. The accelerated corrosion test was carried out by four levels (0%, 1.5%, 3%, and 6%) of chloride added to the concrete. The galvanic current measurements revealed no corrosion current in the FRP Hybrid Bar. The half-cell measurement also showed the corrosion resistance of the FRP Hybrid Bar. Therefore. FHB can be used as an alternative steel for structures where a marine environment and steel corrosion are predicted.

Evaluation of Durability Performance in Concrete Incorporating Low Fineness of GGBFS (3000 Grade) (저분말도 고로슬래그 미분말(3000급)을 혼입한 콘크리트의 내구성능평가)

  • Lee, Seung-Heun;Cho, Sung-Jun;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.96-102
    • /
    • 2019
  • When GGBFS(Ground Granulated Blast Furnace Slag) with high blaine is incorporated in concrete, compressive strength in the initial period is improved, but several engineering problems arise such as heat of hydration and quality control. In this paper, compressive strength and durability performance of concrete with 3,000 Grade-low fineness slag are evaluated. Three conditions of concrete mixtures are considered considering workability, and the related durability tests are performed. Although the strength of concrete with 3,000 Grade slag is slightly lower than the OPC(Ordinary Portland Cement) concrete at the age of 28 days, but insignificant difference is observed in long-term compressive strength due to latent hydration activity. The durability performances in concrete with low fineness slag show that the resistances to carbonation and freezing/thawing action are slightly higher than those of concrete with high fineness slag, since reduced unit water content is considered in 3,000 Grade slag mixture. For the long-term age, the chloride diffusion coefficient of the 3000-grade slag mixture is reduced to 20% compared to the OPC mixture, and the excellent chloride resistance are evaluated. Compared with concrete with OPC and high fineness GGBFS, concrete with lower fineness GGBFS can keep reasonable workability and durability performance with reduced water content.

Carbonation Assessment of High-Strength Concrete Using Polypropylene Fiber after Fire Damage (폴리프로필렌 섬유를 혼입한 고강도 콘크리트의 화재피해 후 중성화 평가)

  • Byun, Yong-Hyun;Ryu, Dong-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.235-243
    • /
    • 2020
  • In recent years, the use of high-strength concrete has increased with increasing height and enlarging scale of the buildings However, it has been pointed out that the use of high-strength concrete is the most serious problem compared to ordinary concrete in terms of the spalling of concrete cross sections caused by fires. For this reason, fiber cocktail methods, which are made of polypropylene fibers, nylon fibers, etc., are mainly used to improve the fire resistance performance. However, the majority of research on high-strength concrete to which the fiber cocktail method was applied is mainly focused on the effect of reducing spalling, and few studies have investigated and analyzed the effect of micropores produced by melting PP fibers on the long-term durability of high-strength concrete after a fire. Therefore, in this study, the effect of micropores on the depth of carbonation was examined through carbonation tests and microstructure analysis, assuming high-strength concrete to which fiber-mixed construction method was applied, which caused fire damage.

Degradation evaluation of paint films on surface treated steel by electrochemical impedance spectroscopy (전기화학적 임피던스 분광법에 의한 표면처리한 강재 도장의 부식-도막 열화도 평가)

  • Park, Jun-Mu;Park, Jae-Hyeok;Kim, Sun-Ho;U, Sang-Gyun;Gwon, Yong-Min;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.95-95
    • /
    • 2018
  • 강재의 방식법 중 도장은 부식을 억제하는데 효과적이고 편리한 방법으로 선박 및 해양 강 구조물의 방식법으로 사용되고 있다. 한편, 강 구조물의 효율적인 유지관리를 위해서는 방식 도장의 도막 열화도를 평가하고 잔존 수명을 예측하여 최적 시기에 보수도장 혹은 재도장하는 것이 필요하다. 일반적으로 선박 및 해양구조물에 적용되는 도막의 방식 성능 평가 방법으로 해수 침지 시험, 염수 분무 시험, 옥외 폭로 시험 등이 있다. 그러나 이러한 시험들은 그 시험 방법에 따라서 정량적인 평가에 한계가 있음은 물론 장기간 소요되는 등 곤란한 문제점이 있다. 그러므로 선박 및 해양구조물을 비롯하여 교량, 각종 강 구조물의 도장 방식에 사용되는 방식용 도료의 성능을 단기간에 적절하게 평가할 수 있는 가속시험법이 제시되며 연구-사용되고 있다. 그 중 도막 방식 성능을 보다 효율적, 비파괴적, 정량적으로 평가할 수 있는 임피던스 분광법(EIS)과 같은 전기화학적 방법은 상대적으로 시험 기간을 크게 단축시킬 수 있고, 대상 방식 도장의 미세한 성능 차이도 분별 가능하다는 장점이 있다[1]. 따라서 본 연구에서는 선박 및 해양구조물 등 가혹한 부식환경에서 강력한 내구성을 가질 수 있도록 다양한 종류의 표면처리 도장 시편을 제작하여 자외선 조사-염수분무-침지환경 등의 열악한 환경조건 하에서 부식-열화 촉진 시험을 실시하였다. 그리고 그 촉진 열화 과정에서 도막의 외관 상태를 관찰 분석함은 물론 전기화학적 임피던스 분광법을 병행 측정하며 그 표면막의 부식 및 도막 열화도를 비교-종합 평가하였다.본 연구에 사용된 시편은 Al 및 Zn 도금 강판에 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편으로 Scribe, No Scribe 및 비교재 Al 및 Zn 도금 시편으로 분류하여 각각 실험을 진행하였다. 즉, 도막 열화 시험은 복합 노화 시험법으로 UV 조사 36 시간(ASTM G53), 염수분무 32 시간(ISO 7253), 수분 응축 10 시간을 1 Cycle로 100 Cycle(7800 시간) 동안 실험을 진행하였다. 이때 도막 열화도 평가는 전기화학적 임피던스 분광법을 이용하여 각 실험 조건별로 주파수에 따른 임피던스(Z) 값을 평가하였다. 즉, 상온 $25^{\circ}C$의 3.5% NaCl 100 ml 수용액에 작동 전극(Working Electrode)과 구리 도선을 통해 연결하였고, 노출 면적은 $1cm^2$로 일정하게 유지 하였으며, 상대 전극(Counter Electrode)은 탄소봉, 기준 전극(Reference Electrode)으로 포화카로멜전극(Saturated Calomel Electrode)을 사용하여 측정하였다. No Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편이 우수한 도막 저항성을 나타내었으며, 에폭시-우레탄 도장시편은 23사이클 이후의 저항값이 가장 낮게 나타났다. Zn 기판의 경우는 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편 모두 저항 값이 유사하였으며, Al 및 Zn 도금 시편은 도장 처리된 시편에 비해 훨씬 낮은 저항 값을 보였다. 또한 Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편에서 높은 초기 저항 값을 보였으며, 23 사이클 후의 저항 값은 세 종류의 도막에서 약 1~0.1 Gohm 으로 나타났다. 그리고 Zn 기판 에폭시-실리콘 우레탄 도장 시편에서 가장 낮은 도막 저항 값이 나타났다. 이상의 실험을 통해서 본 연구 내용은 실내촉진시험으로 선박 및 해양 강 구조물에 사용되는 다양한 종류의 도막의 열화도를 평가하는 기초 설계 지침으로 응용될 수 있을 것으로 사료된다. 한편, 도막은 노출 환경에 따라 방식 성능이 다르므로 실제 도막의 사용환경을 고려하여 도장 사양별 적용 부위에 따른 적정 가속 실험 방법을 선정할 필요가 있다고 사료된다.

  • PDF

Evaluation for Properties of Domestic Pond Ash Aggregate and Durability Performance in Pond Ash Concrete (국산 매립회의 골재특성 평가 및 매립회 콘크리트의 내구 성능 평가)

  • Lee, Bong-Chun;Jung, Sang-Hwa;Kim, Joo-Hyung;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.311-320
    • /
    • 2011
  • Fly ash (FA), byproduct from power plant has been actively used as mineral admixture for concrete. However, since bottom ash (BA) is usually used for land reclaim or subbase material, more active reuse plan is needed. Pond ash (PA) obtained from reclaimed land is mixed with both FA and BA. In this study, 6 PA from different domestic power plant are prepared and 5 different replacement ratios (10%, 20%, 30%, 50%, and 70%) for fine aggregate substitutes are considered to evaluate engineering properties of PA as fine aggregate and durability performance of PA concrete. Tests for fine aggregate of PA for fineness modulus, density and absorption, soundness, chloride and toxicity content, and alkali aggregate reaction are performed. For PA concrete, durability tests for compressive strength, drying shrinkage, chloride penetration/diffusion, accelerated carbonation, and freezing/thawing are performed. Also, basic tests for fresh concrete like slump and air content are performed. Although PA has lower density and higher absorption, its potential as a replacement material for fine aggregate is promising. PA concrete shows a reasonable durability performance with higher strength with higher replacement ratio. Finally, best PA among 6 samples is selected through quantitative classification, and limitation of PA concrete application is understood based on the test results. Various tests for engineering properties of PA and PA concrete are discussed in this paper to evaluate its application to concrete structure.

Study on Corrosion and Structural Performance in Hot-Dip Galvanizing Steel (용융아연도금 철근의 부식 특성 및 구조적 특성에 대한 연구)

  • Kwon, Seung-Jun;Lee, Sang-Min;Lee, Myung-Hoon;Park, Sang-Soon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.613-621
    • /
    • 2012
  • Steel corrosion is one of the most critical deteriorations in concrete structures due to the problems associated with both durability and structural safety issues. For protection of steel against corrosion problems, researches to improve concrete durability and steel corrosion protection such as rebar coating by hot-dip galvanizing steel have been carried out. This study was performed to quantitatively evaluate anti-corrosion and structural performance of concrete structures reinforced with hot-dip galvanizing steel rebar. Preliminary tests for several metal coatings such as zinc, aluminum, and their alloy (Zn 45% + AL 55%) were performed. After evaluation of corrosive characteristics, Zn was selected for the coating material and the corrosion behaviors in Zn-coated steel were evaluated in various conditions. Furthermore, tensile and adhesive strengths were evaluated for the normal and the hot-dip galvanized steel. The crack patterns and structural behaviors of RC specimens with the normal and coated steel were investigated. Also, corrosion characteristics including corrosion in various coating metal and potential change in metal with notch were evaluated. Structural performances of tensile and adhesive strengths as well as RC beam behavior under flexural/shear loading were evaluated. The test and evaluation results showed that the applicability of hot-dip galvanized steel rebar can be used as corrosion resistant reinforcements for RC structures.

Applicability as a Dancheong Pigment Raw Materials of Korean Low Grade Kaolin (국내산 저품위 고령토자원의 단청안료 원료로써의 활용 가능성)

  • Moon, Dong Hyeok;Han, Min Su;Cho, Hyen Goo;Kim, Myoung Nam;Kim, Jae Hwan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.179-190
    • /
    • 2016
  • X-ray diffraction analysis, chromaticity measurement, execution and evaluation by Dancheong artisan, accelerated weathering test, and fire resistance test were conducted to test the applicability as a Dancheong pigment raw materials of Korean low grade kaolin in cultural properties. The ores that feldspar rich and composed of fine particles (< $38.1{\mu}m$) showing advantageous for the inherent purpose of the white pigment than that of high grade kaolin. And the test of whiteness, concealment force, outdoor exposure durability and fire resistance shows similar or better result than existing products (Hobun and Sanhwa jidang). In conclusion, it is expected that the use of fine feldspar rich white soil and low-grade kaolin can be used as a white pigment raw materials which have similar to better material properties and economic efficiency than existing products.